Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Weight function procedure for reduced order fracture analysis of arbitrary flaws in cylindrical pressure vessels

Fracture mechanics calculations using the finite element method can be computationally expensive, which makes them challenging to use in engineering evaluations of flaws in pressure vessels. The weight function (WF) technique is a reduced order fracture modeling method that is widely used to greatly reduce these computational costs. Its computational efficiency is essential for use in probabilistic fracture mechanics evaluations of embrittled nuclear reactor pressure vessels (RPVs), due to the large number of sampled flaws that must be evaluated. Although the WF technique is general, it is typically used only for axis-aligned flaws. Recent discoveries of off-axis flaws in operating nuclear reactors have necessitated detailed simulations of such flaws and the interactions between neighboring flaws. This paper presents a generalized WF approach applicable for analyzing arbitrary flaw geometries in thick-walled cylindrical vessels, including surface-breaking and subsurface flaws, which can either axis-aligned or off-axis, and can account for interactions with other flaws. Herein, this approach is demonstrated on representative simulations of multiple flaw geometries in a RPV subjected to transient loading conditions. In all cases, the WF technique gives good comparison with benchmark results from direct simulation with greatly reduced computational effort.

42 ENGINEERING↗

A Comprehensive Quality Assurance Program for Personnel and Procedures in Radiation Oncology: Value of Voluntary Error Reporting and Checklists

Purpose: This report describes the value of a voluntary error reporting system and the impact of a series of quality assurance (QA) measures including checklists and timeouts on reported error rates in patients receiving radiation therapy. Methods and Materials: A voluntary error reporting system was instituted with the goal of recording errors, analyzing their clinical impact, and guiding the implementation of targeted QA measures. In response to errors committed in relation to treatment of the wrong patient, wrong treatment site, and wrong dose, a novel initiative involving the use of checklists and timeouts for all staff was implemented. The impact of these and other QA initiatives was analyzed. Results: From 2001 to 2011, a total of 256 errors in 139 patients after 284,810 external radiation treatments (0.09% per treatment) were recorded in our voluntary error database. The incidence of errors related to patient/tumor site, treatment planning/data transfer, and patient setup/treatment delivery was 9%, 40.2%, and 50.8%, respectively. The compliance rate for the checklists and timeouts initiative was 97% (P<.001). These and other QA measures resulted in a significant reduction in many categories of errors. The introduction of checklists and timeouts has been successful in eliminating errors related to wrong patient, wrong site, and wrong dose. Conclusions: A comprehensive QA program that regularly monitors staff compliance together with a robust voluntary error reporting system can reduce or eliminate errors that could result in serious patient injury. We recommend the adoption of these relatively simple QA initiatives including the use of checklists and timeouts for all staff to improve the safety of patients undergoing radiation therapy in the modern era.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Free Thyroid Transfer: A Novel Procedure to Prevent Radiation-induced Hypothyroidism

Purpose: The incidence of hypothyroidism after radiation therapy for head and neck cancer (HNC) has been found to be ≤53%. Medical treatment of hypothyroidism can be costly and difficult to titrate. The aim of the present study was to assess the feasibility of free thyroid transfer as a strategy for the prevention of radiation-induced damage to the thyroid gland during radiation therapy for HNC. Methods and Materials: A prospective feasibility study was performed involving 10 patients with a new diagnosis of advanced HNC undergoing ablative surgery, radial forearm free-tissue transfer reconstruction, and postoperative adjuvant radiation therapy. During the neck dissection, hemithyroid dissection was completed with preservation of the thyroid arterial and venous supply for implantation into the donor forearm site. All patients underwent a diagnostic thyroid technetium scan 6 weeks and 12 months postoperatively to examine the functional integrity of the transferred thyroid tissue. Results: Free thyroid transfer was executed in 9 of the 10 recruited patients with advanced HNC. The postoperative technetium scans demonstrated strong uptake of technetium at the forearm donor site at 6 weeks and 12 months for all 9 of the transplanted patients. Conclusions: The thyroid gland can be transferred as a microvascular free transfer with maintenance of function. This technique could represent a novel strategy for maintenance of thyroid function after head and neck irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved lipid analysis using a 2D-LC-MS system with a novel injection procedure

The aim of this study was to improve analysis of nonpolar lipidomics sample extracts using reversed phase (RP) chromatography. A 4/3/3 (v/v/v) mixture of methanol/methyl tert-butyl ether/chloroform (MeOH/MTBE/CHCl 3 , MMC) was chosen for sample extraction solvent based on its proven extraction capability for several lipid classes. To avoid carry over, loss of analytes and peak distortion the loops and all capillaries of the presented LC system were flushed and filled up with methanol until the analytical column. Here, the choice of methanol was due to its weak elution strength and being infinitely miscible with MMC and several other nonpolar solvents. This allowed injection of a 100 μl sample that was 20 μl nonpolar extraction solvent diluted fivefold with methanol. All lipids of 25 lipid classes were transferred quantitatively to the column head where the online dilution of methanol was carried out with aqueous eluent for focusing the lipid analytes. The weak elution strength of methanol prevented peak distortions. The consecutive reversed phase elution resulted in remarkably narrow peaks (full width at half maximum was 0.07–0.08 min typically) and enhanced sensitivity (limit of detection usually in sub nM region) because of increased sample injection volume and narrow peaks. Calibration and quality control samples made by diluting commercial lipid standards 200–50000 times confirmed the applicability of this approach both for targeted lipid quantification and for untargeted quantitative comparison of lipids from different sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Facile preparation of zinc oxide nanorods surrounded by graphene quantum dots both synthesized via separate pyrolysis procedures for photocatalyst application

Highlights: • ZnO NRs and GQDs were made separately via a simple and one-stage pyrolysis method. • Because of the employed compositing method, GQDs compactly surrounded the ZnO NRs. • Bandgap of ZnO NRs decreased from 3.2 to 2.8 eV after they were surrounded by GQDs. • Despite being inefficient alone, GQDs largely enhanced ZnO photocatalytic activity. • The mechanism was mainly attributed to the decrease in recombination rate of ZnO. - Abstract: A facile pyrolysis method was employed for separate synthesis of zinc oxide nanorods (ZnO NRs) and graphene quantum dots (GQDs) and the structures were composited. The structures were characterized by field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), X-ray diffractometry (XRD), and Fourier transform infrared (FTIR) spectroscopy. The structures were optically characterized by UV–vis and photoluminescence (PL) spectrometry techniques, showing that the absorption of ZnO NRs increases in the visible region after being surrounded by GQDs. Optical bandgaps of ZnO NRs and ZnO NRs/GQDs composite were estimated as 3.2 and 2.8 eV, respectively. Based on PL analysis, it was deduced that the generated electron-hole recombination rate of ZnO NRs decreases after being surrounded by GQDs. Finally, it was shown that our GQDs, despite being relatively inefficient separately, significantly enhance the photocatalytic activity of ZnO on methylene blue mainly through decreasing the e-h recombination rate of ZnO NRs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The separatrix electron density in JET, ASDEX upgrade and alcator C-Mod H-mode plasmas: A common evaluation procedure and correlation with engineering parameters

The separatrix electron density is an important parameter for core-edge scenario integration in tokamak devices, as it influences plasma confinement, divertor detachment and disruption avoidance. This quantity has been measured in H-mode discharges on JET, ASDEX Upgrade and Alcator C-Mod by applying the same fitting function to Thomson scattering measurements, and by employing the same analysis technique based on scrape-off layer power balance. To estimate the power crossing the separatrix, the inter-ELM time derivative of the plasma energy d W /d t has been experimentally evaluated and found to be approximately a constant fraction of the absorbed heating power. Correlations between n e,sep and engineering parameters have been investigated, revealing that n e,sep scales with the divertor neutral pressure p 0,div in a similar manner across all devices. Additionally, when n e,sep is normalized to the obtained n e,sep dependency, no clear correlation with the plasma current is found. These observations are in agreement with the 2-point model, which suggests that the upstream separatrix density is mainly set by the recycling at the divertor target.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗