Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Modifying Network Guided Vehicle for Repeatable EcoCAR ACC Energy Testing

The newest iteration of the Department of Energy (DOE) Advanced Vehicle Technology Competitions is the EcoCAR Mobility Challenge. In this paper, ANL and HORIBA MIRA collaborate to propose and pilot a test method that enables controlled, repeatable track-based energy consumption testing of semi-autonomous features. The testing was performed at MIRA’s proving ground facility in Nuneaton, UK, using their Network Guided Vehicle (NGV) connectivity and automation test platform. The NGV served as a repeatable lead vehicle following prescribed drive traces around two different track circuits while the host vehicle under test, a Honda Civic with full speed range Adaptive Cruise Control, followed behind. Over the course of a two day test, multiple iterations of certification and custom EPA drive traces were performed on track, demonstrating the viability of a two vehicle energy test. Results were analyzed to assess NGV lead vehicle performance in following the prescribed cycle using SAE J2951 standard calculations in an effort to quantify how repeatably and accurately the lead vehicle followed the trace. Host vehicle energy consumption was assessed using both vehicle CAN bus monitoring and an on-board fuel flow meter.

ACC↗

Effect of Chemical Composition on the Microstructure and Tribological Properties of Sn-Based Alloys

This article presents the test results of two bearing alloys on a tin matrix, differing in the content of alloy additions. Microscopic tests were performed using scanning electron microscopy, along with Brinell hardness tests and tests of tribological properties in the conditions of technical dry friction and wet friction using a TU-32 oil. Additionally, wear mechanisms were analyzed depending on the process conditions. The results indicate better tribological properties of the B82 alloy, with a higher content of antimony compared to the B89 alloy. This alloy contains more precipitates of hard phase β—SnSb, which both influence the level of the mechanical properties and determine the tribological properties. Additionally, it was proven that using the TU-32 oil as a lubricant practically eliminates adhesive wear, and the post-friction surfaces for both alloys are of a similar nature.

36 MATERIALS SCIENCE↗

Sequential limiting in continuous and discontinuous Galerkin methods for the Euler equations

We present a new predictor-corrector approach to enforcing local maximum principles in piecewise-linear finite element schemes for the compressible Euler equations. The new element-based limiting strategy is suitable for continuous and discontinuous Galerkin methods alike. In contrast to synchronized limiting techniques for systems of conservation laws, we constrain the density, momentum, and total energy in a sequential manner which guarantees positivity preservation for the pressure and internal energy. After the density limiting step, the total energy and momentum gradients are adjusted to incorporate the irreversible effect of density changes. Antidiffusive corrections to bounds-compatible low-order approximations are limited to satisfy inequality constraints for the specific total and kinetic energy. An accuracy-preserving smoothness indicator is introduced to gradually adjust lower bounds for the element-based correction factors. The employed smoothness criterion is based on a Hessian determinant test for the density. Finally, a numerical study is performed for test problems with smooth and discontinuous solutions.

97 MATHEMATICS AND COMPUTING↗

Laboratory pull-out tests on fully grouted rock bolts and cable bolts: Results and lessons learned

Laboratory pull-out tests were conducted on the following rock bolts and cable bolts: steel rebars, smooth steel bars, fiberglass reinforced polymer threaded bolts, flexible cable bolts, IR5/IN special cable bolts and Mini-cage cable bolts. The diameter of the tested bolts was between 16 mm and 26 mm. The bolts were grouted in a sandstone sample using resin or cement grouts. The tests were conducted under either constant radial stiffness or constant confining pressure boundary conditions applied on the outer surface of the rock sample. In most tests, the rate of displacement was about 0.02 mm/s. The tests were performed using a pull-out bench that allows testing a wide range of parameters. This paper provides an extensive database of laboratory pull-out test results and confirms the influence of the confining pressure and the embedment length on the pull-out response (rock bolts and cable bolts). Furthermore, it also highlights the sensitivity of the results to the operating conditions and to the behavior of the sample as a whole, which cannot be neglected when the test results are used to assess the bolt-grout or the grout–rock interface.

42 ENGINEERING↗

Microstructure control to improve creep strength of alumina-forming austenitic heat-resistant steel by pre-strain

Highlights: • The effect of pre-strain on creep strength of AFA steel was studied. • The creep test was performed at 700°C and 200Mpa, and the aging test was carried out using box furnace at 700°C to simulate the microstructural evolution during creep. • Microstuctural evolution was observed by using SEM, EBSD, and TEM to investigate the relationship between creep strength and microstructure. - Abstract: At 700 °C and 200 MPa, the creep rupture time of W-containing alumina-forming austenitic heat-resistant (WAFA) steel increases from 1044 to 3119 h by pre-strain. Pre-strain introduces a lot of dislocation into the matrix and most of the dislocations remain stable to the end of creep without recovery and recrystallization. In addition, the dislocations have enabled secondary NbC and Laves phase to be uniformly distributed and refined. However, the dislocations lower grain boundary strength due to the coarsening of precipitates along grain boundaries Therefore, the increase in the creep rupture time in spite of deterioration of grain boundary strength is attributed to the dislocation strengthening and enhanced precipitation hardening within grains.

36 MATERIALS SCIENCE↗

Electron beam test of key elements of the laser-based calibration system for the muon g - 2 experiment

We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-52: A New Device for Quality Assurance of a Single Isocenter Technique for the Simultaneous Treatment of Multiple Brain Metastases

Purpose: Comprehensive quality assurance (QA) of a single isocenter technique for the simultaneous treatment of multiple brain metastases is presently impractical due to the time consuming nature of measuring each lesion’s dose on film or with a micro-chamber. Three dimensional diode array and full field film measurements are sometimes used to evaluate these plans, but gamma analysis may not reveal local errors that have significant effects on one or a few of several targets. This work aimed to design, build and test a phantom to simplify comprehensive measurement and evaluation. Methods: A phantom was designed with 28 stackable slabs. The top and bottom slabs are 1.5 centimeters (cm) in thickness, and central 26 slabs are 0.5 cm thick. When assembled with radiochromic film in all 27 gaps, the phantom measures 16.5 x 15 x 19 cm. Etchings were designed to aide in identification of specific film planes on computed tomography (CT) images and correlation of individual PTVs with closest bisecting planes. Patient verification plans with a total of 16 PTVs were calculated on the phantom CT, and test deliveries both with and without couch kicks were performed to test the ability to identify correct film placements and subsequent PTV specific dose distributions on the films. Results: Bisecting planes corresponding to PTV locations were easily identified, and PTV specific dose distributions were clear for all 16 targets. For deliveries with couch kicks, the phantom PTV dose distributions closely approximated those calculated on the patient’s CT. For deliveries without couch kicks, PTV specific dosimetry was also possible, although the distributions had ‘ghosts’ equaling the number of couch kicks, with distance between ghosts increasing with distance from the isocenter. Conclusion: A new phantom facilitates fast comprehensive commissioning validation and PTV specific dosimetry for a single isocenter technique for treating multiple brain metastases. This work was partially funded by CIRS, Inc.

60 APPLIED LIFE SCIENCES↗

SU-F-T-180: Evaluation of a Scintillating Screen Detector for Proton Beam QA and Acceptance Testing

Purpose: To test the performance of a commercial scintillating screen detector for acceptance testing and Quality Assurance of a proton pencil beam scanning system. Method: The detector (Lexitek DRD 400) has 40cm × 40cm field, uses a thin scintillator imaged onto a 16-bit scientific CCD with ∼0.5mm resolution. A grid target and LED illuminators are provided for spatial calibration and relative gain correction. The detector mounts to the nozzle with micron precision. Tools are provided for image processing and analysis of single or multiple Gaussian spots. Results: The bias and gain of the detector were studied to measure repeatability and accuracy. Gain measurements were taken with the LED illuminators to measure repeatability and variation of the lens-CCD pair as a function with f-stop. Overall system gain was measured with a passive scattering (broad) beam whose shape is calibrated with EDR film placed in front of the scintillator. To create a large uniform field, overlapping small fields were recorded with the detector translated laterally and stitched together to cover the full field. Due to the long exposures required to obtain multiple spills of the synchrotron and very high detector sensitivity, borated polyethylene shielding was added to reduce direct radiation events hitting the CCD. Measurements with a micro ion chamber were compared to the detector’s spot profile. Software was developed to process arrays of Gaussian spots and to correct for radiation events. Conclusion: The detector background has a fixed bias, a small component linear in time, and is easily corrected. The gain correction method was validated with 2% accuracy. The detector spot profile matches the micro ion chamber data over 4 orders of magnitude. The multiple spot analyses can be easily used with plan data for measuring pencil beam uniformity and for regular QA comparison.

60 APPLIED LIFE SCIENCES↗

TEAMER: Pitching Foil Crossflow Turbine Efficiency Data

This dataset documents the efficiency testing of a pitching foil crossflow turbine, conducted at the University of New Hampshire's (UNH) Chase Ocean Engineering Laboratory tow tank facility. The tests explored various pitch phases and amplitudes, ranging from 0 to 18 degrees, across different flow speeds and turbine RPMs. Specifically, testing was performed at pitch amplitudes of 0,3,6,9,12,15 and 18 degrees. The results indicate that turbine efficiency improves with increased pitch amplitude, reaching optimal performance at 12 degrees. Modifications were made to the test frame by UNH to enhance the stiffness of the support structure. The testing specifically mapped the efficiency of a single quadrant of the Ocean Renewable Power Company (ORPC) Autonomous Turbine Generator Unit (ATGU), covering the full range of allowable pitching amplitudes and phases. The dataset provides both raw and processed data, including drag and torque measurements, and contains Python scripts used for data processing and visualization. This research was supported by funding from TEAMER RFTS 1 (Request for Technical Support).

16 TIDAL AND WAVE POWER↗

Production Facility Prototype Blower 1000 Hour Test Results III

Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Eight long duration 500 and 1000 hour tests have been completed since the first test was performed in January of 2016. All eight long duration tests have proven successful in exposing preventable issues related to oil and helium leaks.

47 OTHER INSTRUMENTATION↗

Evaluation of short-term initial performance of a “Molekule Air” portable air cleaner

The aim of this project was to evaluate and characterize the performance of a MOLEKULE AIR air cleaner unit. The testing protocol comprised the evaluation of an unused Molekule Air unit operating at maximum (“boost” setting) fan speed setting. The device was tested over initial short-term periods of 70-80 h of continuous operation. The tested air cleaner was challenged in separate experiments with a well-characterized mixture of volatile organic compounds (VOCs), and with ozone. All tests were performed at realistic pollutant levels in a 20-m 3 environmental stainless-steel chamber. Variables controlled and measured in this study included the chamber temperature, relative humidity, the composition and concentration of the challenge VOCs, and the concentrations of ozone. Potential formation of byproducts was also investigated to assess the overall performance.

47 OTHER INSTRUMENTATION↗

Extraction, Scrub, and Strip Test Results for the IBC BOBCalix Solvent Samples

A second vendor for solvent extraction components has been chosen for use at the Salt Waste Processing Facility (SWPF). IBC Advanced Technologies (IBC) has provided samples of their BOBCalix, as well as complete solvent. These samples were tested for quality assurance purposes to ensure their use at SWPF is acceptable. Two Extraction, Scrub, and Strip (ESS) tests were performed on solvent samples from IBC. The purpose of testing these samples was to determine if the solvents are displaying the correct extraction and stripping behavior with cesium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Test Beam and Irradiation Facilities

Progress in particle physics depends on a multitude of unique facilities and capabilities that enable to advance detector technologies. Among others, key facilities involve test beams and irradiation facilities, which allow users to test the performance and lifetime of their detectors under realistic conditions. Test beam facilities are particularly important for collider and neutrino detector applications, while irradiation facilities are crucial for collider as well as some space-based astro particle detectors. This contributed Snowmass paper aims to summarize existing test beam and irradiation facilities as well as develop the need and proposals for future facilities.

43 PARTICLE ACCELERATORS↗

Main results of Phenix final core physics tests

The French sodium cooled fast reactor Phenix was shut down in 2009 after 35 years of operation. Before decommissioning a final set of tests was performed. This paper focuses on the following core physics tests: - measurement of control rod reactivity worth by several methods (sub-critical, critical, rod-drop methods), - control rod shifting during a full power operation state, - measurement of individual subassembly reactivity worth (fresh and burned fuel and fertile, sodium hole), - simulation of a gas bubble crossing the core. The control rod measurement test has shown some discrepancies between the different measurement methods, mainly for the rod bank worth. Considering a macroscopic parameter (the reactivity loss estimation), NSMM method seems to produce the better results. The control rod shifting test has highlighted the impact of the spatial effects generated by control rods movements over the power map. These spatial effects, known as shadowing effects, can modify up to 15% the individual control rod worth. The tests concerning individual subassembly worth and gas bubble have permit to evaluate the impact of local perturbations on the reactivity. All these tests can be considered as successful and the ability of the European neutronic code for fast reactors, ERANOS 2.2, to reproduce complex and atypical configuration has been demonstrated by good agreement between measured and computed values. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Perspective on the Successes of the NNSS Underground Test Area (UGTA) Activity - 20221

Between 1951 and 1992, 828 underground nuclear tests were performed at the Nevada National Security Site (NNSS). Underground testing was done in five major testing areas, which included (1) Frenchman Flat, (2) Rainier Mesa/Shoshone Mountain, (3) Yucca Flat/Climax Mine (4) Central Pahute Mesa, and (5) Western Pahute Mesa. About one third of the underground tests were detonated near, at or below the water table, and thus radioactive contamination was introduced to the groundwater system. The U.S. Department of Energy's Underground Test Area (UGTA) Activity was established in the late 1990's to address the fate and movement of residual radioactivity in groundwater, and characterize the risk that it may pose to NNSS workers and the offsite public. It has accomplished this goal through a process of iterative groundwater sampling and numerical groundwater flow and transport modeling, and long-term monitoring. The UGTA Activity draws on the expertise of scientists in the fields of geology, hydrology, radiochemistry, and risk assessment from the U.S. DOE staff, the lead contractor (currently Navarro) and many other organizations, in cooperation with the governing regulatory body, the State of Nevada's Division of Environmental Protection (NDEP). Los Alamos National Laboratory (LANL) is one of the participating research organizations involved with the UGTA Activity. Under the direction of DOE and the lead contractor, LANL's role in UGTA has evolved over time from an initial focus on geologic characterization, to conducting field and laboratory experiments, and finally to its current role of providing modeling and geochemistry expertise to characterize the rates and directions of groundwater and radionuclide movement. In its current role, LANL has either developed or provided the numerical tools for developing flow and transport models in each of the four major testing areas. In addition, LANL has provided an independent assessment of future groundwater flow and transport behavior through the analysis of naturally-occurring geochemical and isotopic tracers in groundwater. The five major testing areas are now in different stages of investigation or closure: (1) Frenchman Flat is in its fifth year of post closure modeling; (2) The Rainier Mesa/Shoshone Mountain Closure Report has been submitted to NDEP and is awaiting approval; (3) The Yucca Flat/Climax Mine Closure Report is under development; and (4) Central and (5) Western Pahute Mesa is still undergoing investigation and flow and transport model development. The success of the UGTA Activity in reaching or approaching closure in three of the five major testing areas is primarily due to the DoE's focus on regulatory closure requirements, but also is in part attributable to a rigorous internal review process and the involvement of NDEP and Nye County water professionals as participants and observers in the reviews. County and state involvement in the internal review process has promoted trust that the U.S. DOE is deeply committed to ensuring the present and future safely of NNSS workers and the surrounding communities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reversible Bending Fatigue Test System for Investigating Vibration Integrity of Spent Nuclear Fuel during Transportation

Transportation packages for spent nuclear fuel (SNF) must meet safety requirements under normal and accident conditions as specified by federal regulations. During transportation, SNF experiences unique conditions and challenges to cladding integrity due to the vibrational and impact loading during road or rail shipment. Oak Ridge National Laboratory (ORNL) has been developing testing capabilities that can be used to improve the understanding of the impacts on SNF integrity due to vibration loading, especially for high burn-up SNF in normal transportation operation conditions. This information can be used to meet the nuclear industry and U.S. Nuclear Regulatory Commission needs in the area of safety and security of spent nuclear fuel storage and transport operations. The ORNL developed test system can perform reversible-bending fatigue testing to evaluate both the static and dynamic mechanical response of SNF rods under simulated loads. The testing apparatus is also designed to meet the challenges of hot-cell operation, including remote installation and detachment of the SNF test specimen, in-situ test specimen deformation measurement, and implementation of a driving system suitable for use in a hot cell. The system contains a U-frame set-up equipped with uniquely designed grip rigs, to protect SNF rod and to ensure valid test results, and use of 3 specially designed LVDTs to obtain the in-situ curvature measurement. A variety of surrogate test rods have been used to develop and calibrate the test system as well as in performing a series of systematic cyclic fatigue tests. The surrogate rods include stainless steel (SS) cladding, SS cladding with cast epoxy, and SS cladding with alumina pellets inserts simulating fuel pellets. Testing to date has shown that the interface bonding between the SS cladding and the alumina pellets has a significant impact on the bending response of the test rods as well as their fatigue strength. The failure behaviors observed from tested surrogate rods provides a fundamental understanding of the underlying failure mechanisms of the SNF surrogate rod under vibration which has not been achieved previously. The newly developed device is scheduled to be installed in the hot-cell in summer 2013 to test high burnup SNF.

high burn-up spent fuel↗

Experimental and modeling results of creep fatigue life of Inconel 617 and Haynes 230 at 850 C

Creep fatigue testing of Ni-based superalloy Inconel 617 and Haynes 230 were conducted in the air at 850 C. Tests were performed with fully reversed axial strain control at a total strain range of 0.5%, 1.0% or 1.5% and hold time at maximum tensile strain for 3, 10 or 30 min. In addition, two creep fatigue life prediction methods, i.e. linear damage summation and frequency-modified tensile hysteresis energy modeling, were evaluated and compared with experimental results. Under all creep fatigue tests, Haynes 230 performed better than Inconel 617. Compared to the low cycle fatigue life, the cycles to failure for both materials decreased under creep fatigue test conditions. Longer hold time at maximum tensile strain would cause a further reduction in both material creep fatigue life. The linear damage summation could predict the creep fatigue life of Inconel 617 for limited test conditions, but considerably underestimated the creep fatigue life of Haynes 230. In contrast, frequency-modified tensile hysteresis energy modeling showed promising creep fatigue life prediction results for both materials.

Chen, Xiang↗