Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

JPL activities on development of acousto-optic tunable filter imaging spectrometer

Recent activities of JPL in the development of a new type of imaging spectrometers for earth observation and planetary exploration are reported. This instrument uses the acousto-optic tunable filter (AOTF) as high resolution and fast programmable bandpass filter. AOTF operates in the principle of acousto-optic interaction in an anisotropic medium. This filter can be tuned in sequential, random, and multiwavelength access modes, providing observational flexibility. The diffraction process in the filter generates two diffracted monochromatic beams with polarization orthogonal to each other, creating a unique capability to measure both polarimetric and spectral properties of the incoming light simultaneously with a single instrument. The device gives wide wavelength operations with reasonably large throughput. In addition, it is in a compact solid-state structure without moving parts, providing system reliability. These attractive features give promising opportunities to develop a new generation of airborne/spaceborne and ground, real-time, imaging spectrometer systems for remote sensing applications.

Cheng, Li-Jen↗

Fitting local, low-dimensional parameterizations of optical turbulence modeled from optimal transport velocity vectors

This work exploits a connection between optimal transport theory and the physics of image propagation to yield a locally low-dimensional model of turbulence-corrupted imagery. Optimal transport produces an invertible, pixel-wise linear trajectories to approximate the globally nonlinear turbulence between a clean and turbulence corrupted image pair. We use the low-dimensional model to fit subsets of the optimal transport vector fields and stitch the local models into a surrogate for the global map to be used for image cleaning. Experiments are performed on laboratory generated data of beam propagation using different values of the Fried parameter (a scale measuring turbulence coherence) as well as a toy data set. The results suggest this is a fruitful direction, and first step, towards using multiple realizations of turbulence corrupted images to learn a blind surrogate for the optimal transport vector field for image cleaning.

47 OTHER INSTRUMENTATION↗

Calibration of photo sensors for the space-based cosmic ray telescope JEM-EUSO

In order to unveil the mystery of ultra-high energy cosmic rays (UHECRs), the planned fluorescence telescope JEM-EUSO (Extreme Universe Space Observatory on-board Japanese Experiment Module) will observe extensive air showers induced by UHECRs from the International Space Station (ISS) orbit with a huge acceptance. The JEM-EUSO instrument consists of Fresnel optics and a focal surface detector with 5000 multi-anode photomultiplier tubes (MAPMTs), 300000 channels in total. For fluorescence detection of cosmic rays it is essential to calibrate the detector pre-flight with utmost precision and to monitor the performance of the detector throughout the whole mission time. For that purpose a calibration stand on-ground was built to measure precisely the performance of Hamamatsu 64 pixel MAPMTs that are planned to be used for JEM-EUSO. To investigate the suitability of alternative detector devices, further research is done with state-of-the-art silicon photomultipliers (SiPMs), namely Hamamatsu multi-pixel photon counters (MPPCs). These will also be tested in the calibration stand and their performance can be compared to conventional photomultiplier tubes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helium line ratio spectroscopy for high spatiotemporal resolution plasma edge profile measurements at ASDEX Upgrade (invited)

The thermal helium beam edge diagnostic has recently been upgraded at the ASDEX Upgrade (AUG) tokamak experiment. Line ratio spectroscopy on neutral helium is a valuable tool for simultaneous determination of the electron temperature and density of plasmas. The diagnostic now offers a temporal resolution of 900 kHz with a spatial resolution of up to 3 mm at 32 lines of sight (LOS) simultaneously. The LOS covers a radial region of 8.5 cm, starting at the limiter radius and reaching into the confined region beyond the separatrix. Two components are of particular importance for the aforementioned hardware improvements. The first is the optical head, which collects the light from the experiment. Equipped with an innovative clamping system for optical fiber ends, an arbitrary distribution pattern of LOS can be achieved to gain radial and poloidal profiles. The second major development is a new polychromator system that measures the intensity of the 587 nm, 667 nm, 706 nm, and 728 nm helium lines simultaneously for 32 channels with filter-photomultiplier tube arrays. Thus, the thermal helium beam diagnostic supplements the AUG edge diagnostics, offering fast and spatially highly resolved electron temperature and density profile measurements that cover the plasma edge and scrape-off layer region. Plasma fluctuations, edge localized modes, filaments, and other turbulent structures are resolved, allowing analysis of their frequency and localization or their propagation velocity.

47 OTHER INSTRUMENTATION↗

The optics and calibration of the Venus solar flux radiometer

The described instrument is to measure the net solar radiation as a function of altitude as the probe descends through the Venus atmosphere. The data are to provide a basis for the study of the mechanisms which are responsible for the high surface temperature of the planet Venus. The instrument consists of two separate sections, including an optical head and an electronics package. The radiance is measured with silicon and indium arsenide detectors. Details of radiometer design are discussed along with the characteristics of the optical system and the detectors. Angular and radiometric calibration procedures are also considered.

Palmer, J. M.↗

Active Cancellation of Servo-Induced Noise on Stabilized Lasers via Feedforward

Many precision laser applications require active frequency stabilization. However, such stabilization loops operate by pushing noise to frequencies outside their bandwidth, leading to large “servo bumps” that can have deleterious effects for certain applications. The prevailing approach to filtering this noise is to pass the laser through a high-finesse optical cavity, which places constraints on the system design. Here, we propose and demonstrate a different approach where a frequency error signal is derived from a beat note between the laser and the light that passes through the reference cavity. The phase noise derived from this beat note is fed forward to an electro-optic modulator after the laser, carefully accounting for relative delay, for real-time frequency correction. With a hertz-line-width laser, we show ≳20 dB noise suppression at the peak of the servo bump (approximately 250 kHz) and a noise-suppression bandwidth of approximately 5 MHz—well beyond the servo bump. By simulating the Rabi dynamics of a two-level atom with our measured data, we demonstrate substantial improvements to the pulse fidelity over a wide range of Rabi frequencies. Here, our approach offers a simple and versatile method for obtaining a clean spectrum of a narrow-line-width laser, as required in many emerging applications of cold atoms, and is readily compatible with commercial systems that may even include wavelength conversion.

47 OTHER INSTRUMENTATION↗

Thickness dependence of piezo-bimorph adaptive mirror bending

A new generation of adaptive x-ray optics (AXO) is being installed on high-coherent-flux x-ray beamlines worldwide to correct and control the optical wavefront with sub-nm precision. These ultra-smooth mirrors achieve high reflectivities at glancing angles of incidence and can be hundreds of mm long. One type of adaptive x-ray mirror relies on piezoelectric ceramic strips which are segmented into channels and actuated to induce local, longitudinal bending, generating one-dimensional shape changes in the mirror substrate. A recently described mirror model uses a three-layer geometry with parallel actuators on the front and back surfaces of a thicker mirror substrate. By analogy to a solved problem in the thermal actuation of a tri-metal strip, we show that the achievable bending radius varies approximately as the square of the substrate thickness. We provide an analytic solution and simulate bending using a finite-element model.

47 OTHER INSTRUMENTATION↗

POLARIMETRY WITH THE GEMINI PLANET IMAGER: METHODS, PERFORMANCE AT FIRST LIGHT, AND THE CIRCUMSTELLAR RING AROUND HR 4796A

We present the first results from the polarimetry mode of the Gemini Planet Imager (GPI), which uses a new integral field polarimetry architecture to provide high contrast linear polarimetry with minimal systematic biases between the orthogonal polarizations. We describe the design, data reduction methods, and performance of polarimetry with GPI. Point-spread function (PSF) subtraction via differential polarimetry suppresses unpolarized starlight by a factor of over 100, and provides sensitivity to circumstellar dust reaching the photon noise limit for these observations. In the case of the circumstellar disk around HR 4796A, GPI's advanced adaptive optics system reveals the disk clearly even prior to PSF subtraction. In polarized light, the disk is seen all the way in to its semi-minor axis for the first time. The disk exhibits surprisingly strong asymmetry in polarized intensity, with the west side ≳ 9 times brighter than the east side despite the fact that the east side is slightly brighter in total intensity. Based on a synthesis of the total and polarized intensities, we now believe that the west side is closer to us, contrary to most prior interpretations. Forward scattering by relatively large silicate dust particles leads to the strong polarized intensity on the west side, and the ring must be slightly optically thick in order to explain the lower brightness in total intensity there. These findings suggest that the ring is geometrically narrow and dynamically cold, perhaps shepherded by larger bodies in the same manner as Saturn's F ring.

79 ASTRONOMY AND ASTROPHYSICS↗

Near-field terahertz nonlinear optics with blue light

Abstract The coupling of terahertz optical techniques to scattering-type scanning near-field microscopy (s-SNOM) has recently emerged as a valuable new paradigm for probing the properties of semiconductors and other materials on the nanoscale. Researchers have demonstrated a family of related techniques, including terahertz nanoscopy (elastic scattering, based on linear optics), time-resolved methods, and nanoscale terahertz emission spectroscopy. However, as with nearly all examples of s-SNOM since the technique’s inception in the mid-1990s, the wavelength of the optical source coupled to the near-field tip is long, usually at energies of 2.5 eV or less. Challenges in coupling of shorter wavelengths (i.e., blue light) to the nanotip has greatly inhibited the study of nanoscale phenomena in wide bandgap materials such as Si and GaN. Here, we describe the first experimental demonstration of s-SNOM using blue light. With femtosecond pulses at 410 nm, we generate terahertz pulses directly from bulk silicon, spatially resolved with nanoscale resolution, and show that these signals provide spectroscopic information that cannot be obtained using near-infrared excitation. We develop a new theoretical framework to account for this nonlinear interaction, which enables accurate extraction of material parameters. This work establishes a new realm of possibilities for the study of technologically relevant wide-bandgap materials using s-SNOM methods.

47 OTHER INSTRUMENTATION↗

End-to-end Modeling of Lyot Coronagraph for LUVOIR: Sensitivity to Segment-Level Aberrations

Direct imaging and spectroscopic characterization of atmospheres of Earth-like exoplanets require starlight suppression to detect a faint planetary signal at small angular separations. Future space telescopes will require segmentation to survey a statistically significant population of nearby stars systems by increasing aperture size beyond the limits set by traditional monolithic apertures; however, segmentation also represents an additional challenge due to the introduction of temporal pupil discontinuities in terms of both phase and amplitude. For this study, a baseline Lyot coronagraph is used with the Large UV / Optical /Infrared (LUVOIR) mission’s 15-m on-axis, segmented optical telescope assembly (OTA). We present a high-fidelity, end-to-end modeling approach developed as part of the Segmented Coronagraph Design and Analysis (SCDA) group that includes diffractive optical propagations at the 1e-10 contrast level across the entire optical train including the OTA and intermediate re-imaging optics inside the coronagraph instrument. We perform a tolerancing analysis to assess the contrast sensitivity to wavefront perturbations for a set of key telescope terms including segment-level low-order and mid-spatial frequency aberrations. As an input to the end-to-end telescope model, we use two industry-provided segment-level wavefront aberration datasets pertaining: (1) thermal gradients and accelerations (courtesy of Ball-Aerospace and L3-Harris), and (2) telescope dynamics including line-of-sight and segment jitter (courtesy of Lockheed-Martin). Contrast performance outputs of the coronagraph are fed into a mission design reference simulator to assess the scientific yield sensitivity. End-to-end modeling will incorporate performance improvements due to active wavefront sensing and control and/or segment-level metrology to improve system performance.

Optics↗

Liquid level sensing for harsh environment applications using distributed fiber optic temperature measurements

This work demonstrates the measurement of liquid level from spatially distributed temperature measurements using optical frequency domain reflectometry. The goal of this work is to provide initial evidence for a liquid level sensor concept that could be applied in harsh environments such as those with: conductive, flammable, or other chemically aggressive media; electromagnetic interference; high temperatures (up to ~1000 °C); and neutron/gamma radiation. The sensor concept includes fiber optic sensors, along with an insulated heater wire assembled inside a protective Inconel 600 sheath. When the heater is not powered, the sensor provides spatially distributed temperature measurements along the length of the fiber. When the heater is powered, the difference in heat transfer in the liquid vs. vapor sections leads to a higher fiber temperature at locations above the liquid/vapor interface. The initial demonstration described in this work tested the sensor in a tank of water that was drained in increments of 2.5 cm. A model for determining liquid level from the distributed temperature measurements was developed that resulted in an accuracy of ±0.5 cm. Finally, the paper addresses potential effects of axial conduction through the sensor sheath, as well as ways to limit these effects to avoid “smearing” of what would otherwise be a step change in temperature at the liquid/vapor interface.

42 ENGINEERING↗

Technology development for ultraintense all-OPCPA systems

Optical parametric chirped-pulse amplification (OPCPA) [Dubietis et al. , Opt. Commun. 88 , 437 (1992)] implemented by multikilojoule Nd:glass pump lasers is a promising approach to produce ultraintense pulses ( ${>}10^{23}~\text{W}/\text{cm}^{2}$ ). Technologies are being developed to upgrade the OMEGA EP Laser System with the goal to pump an optical parametric amplifier line (EP OPAL) with two of the OMEGA EP beamlines. The resulting ultraintense pulses (1.5 kJ, 20 fs, $10^{24}~\text{W}/\text{cm}^{2}$ ) would be used jointly with picosecond and nanosecond pulses produced by the other two beamlines. A midscale OPAL pumped by the Multi-Terawatt (MTW) laser is being constructed to produce 7.5-J, 15-fs pulses and demonstrate scalable technologies suitable for the upgrade. MTW OPAL will share a target area with the MTW laser (50 J, 1 to 100 ps), enabling several joint-shot configurations. We report on the status of the MTW OPAL system, and the technology development required for this class of all-OPCPA laser system for ultraintense pulses.

47 OTHER INSTRUMENTATION↗

A NEW VIEW OF VEGA'S COMPOSITION, MASS, AND AGE

We present estimates of Vega's composition, mass, and age based on a simultaneous fit of high-resolution metal line profiles, the wings of the Balmer lines, the absolute visible/near-IR fluxes, and high angular resolution triple phase data from the Navy Prototype Optical Interferometer to gravity-darkened Roche models. This substantially expands our earlier analysis. We determine that Vega has a much lower mass, 2.135 +- 0.074 M{sub sun}, than generally assumed. This strongly supports the contention that Vega is metal-poor throughout (Z approx 0.008), suggesting it was formed that way. Assuming a uniform composition equal to that derived for the surface, and the luminosity and radius obtained here, we derive a best estimate of Vega's age, 455 +- 13 Myr, and mass, 2.157 +- 0.017 M{sub sun}, by fitting to standard isochrones. We continue to argue that Vega is much too old to be coeval with other members of the Castor moving group and is thus unlikely to be a member. The updated chemical abundances continue to support the conclusion that Vega is a lambda Boo star.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatially resolved measurements to improve analytical performance of solution-cathode glow discharge optical-emission spectrometry

We report past studies of the solution-cathode glow discharge (SCGD) revealed that elemental and molecular emission are not spatially homogenous throughout the source, but rather conform to specific zones within the discharge. Exploiting this inhomogeneity can lead to improved analytical performance if emission is collected only from regions of the discharge where analyte species emit strongly and background emission (from continuum, elemental and/or molecular sources) is lower. Effects of this form of spatial discrimination on the analytical performance of SCGD optical emission spectrometry (OES) have been investigated with an imaging spectrograph for fourteen atomic lines, with emphasis on detection limits and precision. Vertical profiles of the emission intensity, signal-to-background ratio, and signal-to-noise ratio were collected and used to determine the optimal region to view the SCGD on a per-element basis. With optimized spatial filtering, detection limits ranged from 0.09–360 ppb, a 1.4–13.6 fold improvement over those obtained when emission is collected from the full vertical profile (1.1– 840 ppb),with a 4.2-fold average improvement. Precision was found to be unaffected by spatial filtering, ranging from0.5–2.6% relative standard deviation (RSD) for all elements investigated, closely comparable to the 0.4–2.4% RSD observed when no spatial filtering is used. In conclusion, spatial profiles also appear useful for identifying optimal line pairs for internal standardization and for flagging the presence of matrix interferences in SCGD-OES.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distributed Acoustic Sensing (DAS) on Opportunistic Networks_ A Feasibility Study Utilizing Fiber Optic Infrastructure at NEON Sites for DAS

This study demonstrates the feasibility of using Distributed Acoustic Sensing (DAS) on the opportunistic optical fiber infrastructure presented by NEON (National Ecological Observatory Network) sites. The test took place at the NEON Terrestrial Site designated D10 CPER. Unlit portions of the local fiber network were successfully spliced together and optimized for length and a Silixa iDAS sensor was installed. The resulting array (composed of 12 spliced fiber runs) totaled 875m in length. Over a period of 2 weeks, we gathered a high spatial and temporal resolution data set to characterize discernable signals and understand background noise. The data set was reviewed to extract wave signatures of identifiable origin, both anthropogenic and otherwise. Continent wide distribution of these sites makes them an interesting candidate for DAS and identifying measurable signal sources informs future DAS application on opportunistic fiber networks. These observations validate the utility of both the NEON and similarly small fiber networks (<1km) for geoscience, environmental, and security DAS applications and indicate possibilities for further inquiry in methods for DAS data collection and analysis.

42 ENGINEERING↗

Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers

During the past few years, the Orion high-resolution x-ray spectrometers have been successful tools for measuring x-ray spectra from plasmas generated in the Orion laser facility. Duplicate spectrometers also operate successfully at the Livermore EBIT-I and SuperEBIT electron beam ion traps for measuring x-ray polarization. We have recently implemented very high-quality, optically bonded, spherically bent quartz crystals to remove the structure in the x-ray image that had been observed in earlier measurements. The structure had been caused by focusing defects and limited the accuracy of our measurements. In this work, we present before and after images that show a drastic improvement. We, furthermore, have implemented a spherically bent potassium acid phthalate (KAP) crystal on one of our spectrometers. The KAP crystal was prepared in a similar fashion, and we present measurements of the N Ly-β and Ne Lyβ lines taken in first- and second-order reflections at 600 and 1200 eV, respectively. These measurements confirm that KAP crystals can be produced at a quality suitable for extending the spectral coverage to wavelengths longer than those accessible by different quartz crystals, especially those that cover the astrophysically important lines of iron.

47 OTHER INSTRUMENTATION↗

Control Algorithms for Dual-wavefront Sensor Single-conjugate Adaptive Optics

High-contrast imaging systems using active control with adaptive optics (AO) are often limited by non-common path (NCP) aberrations that are seen only at the final science image. AO systems employing focal-plane wavefront sensors (FP-WFSs) are able to simultaneously correct NCP aberrations and measure science images, but they typically require a second stage of control that adds system cost and complexity. We present control algorithms to augment AO systems with FP-WFSs within their existing control setup. We demonstrate inter-arm NCP aberration transfer can be mitigated through temporal filtering, present frequency- and time-domain validation of controller stability and performance, and discuss the optimality of the chosen controllers. This work will enable the development, testing, and installation of FP-WFS technologies for direct imaging of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved filters for angular filter refractometry

Angular filter refractometry is an optical diagnostic that measures the absolute contours of a line-integrated density gradient by placing a filter with alternating opaque and transparent zones in the focal plane of a probe beam, which produce corresponding alternating light and dark regions in the image plane. Identifying transitions between these regions with specific zones on the angular filter (AF) allows the line-integrated density to be determined, but the sign of the density gradient at each transition is degenerate and must be broken using other information about the object plasma. Additional features from diffraction in the filter plane often complicate data analysis. Here, in this paper, we present an improved AF design that uses a stochastic pixel pattern with a sinusoidal radial profile to minimize unwanted diffraction effects in the image caused by the sharp edges of the filter bands. We also present a technique in which a pair of AFs with different patterns on two branches of the same probe beam can be used to break the density gradient degeneracy. Both techniques are demonstrated using a synthetic diagnostic and data collected on the OMEGA EP (extended performance) laser.

47 OTHER INSTRUMENTATION↗