Comprehensive Air Monitoring Report for Measurements during the Las Conchas Fire at Los Alamos National Laboratory
During the Las Conchas Fire, ambient air was monitored for radionuclides and particulate matter at and around Los Alamos National Laboratory (the Laboratory). During the fire, a variety of samplers were deployed, including the radiological air sampling network, high-volume air samplers, Tapered Element Oscillating Microbalances (PM 2.5 and PM 10), and environmental continuous air monitors. These different types of samplers provided real time, more in-depth retrospective information on air quality. In total, roughly 220 air samples were collected, and the results were consistent with other regional fires. Laboratory officials and Los Alamos County used real-time data to make public health risk determinations according to the Air Quality Index. Particulate levels were elevated and exceeded the National Ambient Air Quality Standard during the fire because of smoke. Elevated levels of naturally occurring radon decay products, consistent with all forest fires, were detected. Gross-alpha measurements had an average of range of 400 aCi/m 3 to 13,400 aCi/m 3 . Measurements of gross beta during the fire had a range of 34,000 aCi/m 3 to 74,000 aCi/m 3 . These values are not statistically different from national or regional averages.