Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Select Electronic Parts Operation at Extreme Low Temperature

The purpose of the study presented in this paper is to extend the test period of a selected set of electronics parts at cryogenic condition to dwell period of about 24 hours to demonstrate extreme cold operational capability of these components. The parts tested are tantalum polymer, BX and P90 type ceramic capacitors, thick film resistors, analog multiplexers, a digital inverter, and a D-flip-flop. These parts were tested to assist identifying candidate components that can be used for development of a cold capable telemetry board. There are several past investigations that have shown that COTS (commercial-off-the-shelf) capacitors and resistors tested at cryogenic temperatures and frequencies up to 10MHz did not exhibit significant changes in capacitance and resistance values. Also, there are several test results for active parts. These past tests collected measurements during a temperature sweep from room temperature down to cryogenic temperature with very short dwell time at cryogenic temperature, and back to room temperature. This study extends the operational dwell time to at least 24 hours and returning to room temperature operation without significant degradation in performance, thus, demonstrating the potential for longer dwell time in actual operation in these extreme cold temperatures and a method for identifying the cold operability.

Ashtijou, Mohammad↗

Adaptive Wavelength Scanning Lidar (AWSL) for 3D Mapping from Space

We present the design and performance of an adaptive wavelength scanning lidar (AWSL) for highly efficient mapping from low Earth orbit (LEO). Mapping is accomplished by steering a laser beam across 1,200 resolvable spots using wavelength tuning and grating dispersion. Any subset of these 1,200 spots can be selected by wavelength switching. The design is validated with an 1550-nm prototype using a fast wavelength-tuned (500-kHz) pulsed (2-ns) fiber laser with the beam dispersed by gratings for beam steering. Reflected pulses are detected with an eight-pixel detector array with single-photon sensitivity. Eight lidar returns are time-multiplexed to one output that is digitized with a single 1-GSPS-digitizer, to save power. A grating spectrometer rejects solar background noise spatially and spectrally, and images laser footprints on to the detector array. The gratings retain the fiber laser beam quality. We are developing a 1030-nm AWSL intended for a LEO SmallSat platform.

Guangning Yang↗

One Year in the Extreme Isolation of Antarctica—Is This Enough to Modulate an “Allergic” Sensitization?

(1) Background: After spending a year wintering in Antarctica, individual expedition members have reported increased or even new allergic reactions to environmental allergens after their return. (2) Methods: Blood samples from five overwintering crews were analyzed using the chip based multiplex ALEX Allergy Explorer (MacroArray Diagnostics GmbH, Austria). (3) Results: About one third of the 39 participants displayed specific IgEs against pollen. In most individuals, kinetics showed a reduction in the specific IgE at the time about nine months after deployment to Antarctica. Five participants had the highest specific IgE levels after returning to the “normal” world. The examination of the specific IgE relative to house dust mites and storage mites showed different kinetics. Six out of 10 had the highest specific IgE concentrations at the inner Antarctic measurement time point. These data corresponded well to the general situation in the stations. At the stations themselves, there were almost no pollen particle load, especially at Concordia. (4) Conclusions: Antarctic long-term confinement can induce an altered immune function, which is in some individuals pronounced after return to the familiar allergen environment. Future prospective studies in larger cohorts are needed to further specify these first results.

Matthias Feuerecker↗

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

EXCAP-LR: Exploration Capabilities Logistics Reduction

All human space missions require substantial logistical mass and volume. As our exploration missions increase in distance and duration, reduction of these logistics requirements becomes more important. The movement and tracking of logistics between vehicle elements are increasingly recognized as critical to crew efficiency and on-orbit mission assurance. This project targets the best opportunities to demonstrate logistics reduction, repurposing, and efficient tracking and management of logistics. These technologies and innovations will make future exploration missions more affordable. - REALM-3 (RFID (Radio Frequency Identification) Enabled Autonomous Logistics Management) – Hydra (HYper-Distributed RFID Antenna) Smart Stow: receives RFID signal from readers, use very small % of signal to self-power on-board microcontroller and RF switch, multiplex RFID signal to other nodes in a chain or to a multitude of antennas. ISS HYDRA Smart Stow is over-instrumented to allow evaluation of a branched network HYDRA chain. - UWMS (Universal Waste Management System) – provides a compact, lower mass/volume toilet for exploration missions - ACS (Advanced Clothing Systems) – investigates ways to reduce clothing mass and volume directly or through efficiently cleaning them for reuse.

Patrick Fink↗

Refinement of the Transition-edge Sensor Design for ATHENA X-IFU

The X-ray Integral Field Unit (X-IFU) instrument on the Advanced Telescope for High ENergy Astrophysics (ATHENA) is baselined to have 2376 transition-edge sensor (TES) microcalorimeter pixels in a single array. The required performance for X-IFU has been demonstrated on a kilo-pixel array of square TES’s with 50 m side length, and this is considered the baseline pixel design. However, over the last few years we have explored small modifications to this design in search of a globally optimized instrument performance. We have previously reported on investigations of extending the length of the TES’s and variations in the number of X-ray absorber support stems. Here we report on investigations of TES designs with a length of 50 m but narrower width. We will discuss the consequence of this on magnetic field sensitivity, resistive transition parameters, spectral performance, and ease of multiplexing. We will also discuss how the number and position of the absorber attachments influences the vibrational modes of the pixels, and the impact this may have on performance. Finally, we will present measurements of more substantial change options of our TES design, including more extreme TES geometries, the use of metal islands or etched holes in the silicon nitride membranes, and the position of wiring to minimize current-induced magnetic field effects. The exploration of all these changes to the design are not only useful for optimizing performance on X-IFU, but also guide our fundamental understanding of the key physics of TES microcalorimeters.

Nick Wakeham↗

Development and Airborne Demonstration of the Concurrent Artificially-Intelligent Spectrometry and Adaptive Lidar System: Advancing Lidar Capabilities for the STV Observing System

We report on the design, build and planned airborne demonstration of a spaceflight-prototype Concurrent Artificially-intelligent Spectrometry and Adaptive Lidar System (CASALS). The CASALS lidar is an Adaptive Wavelength Scanning Lidar (AWSL) operating in push broom mode. The demonstration has three major goals: advance the Technical Readiness Level of the AWSL hardware, validate its measurement performance and mature algorithms and methods needed for the Surface Topography and Vegetation (STV) observing system. AWSL acquires parallel tracks of surface heights by rapidly steering a laser beam across a swath. A 1040nm-centered laser is tuned across 30nm and carved into 2-ns pulses, the pulse energy is fiber amplified and the pulses are dispersed cross-track using a non-mechanical wavelength-to-angle grating. For the spaceflight system the beam will be pointable to 1200 10m footprints across a 7km swath. For the airborne demonstration there will be 256 0.7m footprints across a 110m swath. In both cases the footprints overlap across- and along-track for uniform target illumination. For the airborne demonstration a steering mirror will increase the accessible swath width to 4km. At the receiver, solar radiation is filtered with a narrow-slit grating-spectrometer and the footprints are imaged onto a linear-mode, photon-sensitive HgCdTe APD-array. The received pulses are time-division-multiplexed to a few high-speed analog-to-digital converters to record waveforms. Spaceflight and airborne CASALS are designed to nominally detect 20 photons per pulse and, by averaging 27 overlapping footprints, achieve 2cm flat target range precision and high-quality vegetation structure waveforms The AWSL will be flown in the summer of 2024, along with a Headwall VNIR-SWIR hyperspectral sensor imaging a 4km wide swath, at NEON eddy covariance flux towers in the U.S. mid-Atlantic where high resolution hyperspectral and lidar data, acquired annually, are available for validation.

Guangning Yang↗

Design, Fabrication, Testing and Validation of a Ruggedized Fiber Optic Sensing System (FOSS) for Launch Application

Fiber-optic sensors based on fiber Bragg grating (FBG) is desirable for structural health monitoring and is used for various aerospace applications such as measuring strain and temperature, where a single optical fiber can multiplex hundreds of FBG sensors. The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (AFRC) (Edwards, California) has been developing an optical fiber-based sensing suite called Fiber Optics Sensing System (FOSS) over the past two decades. Successful strain monitoring flight demonstrations such as the NASA Ikhana (General Atomics, San Diego, California) remotely piloted aircraft and the X-56A Multi-Utility Technology Testbed (Lockheed Martin Corporation, Bethesda, Maryland) remotely piloted subscale aircraft have been performed. Interest in adapting fiber-optic sensors for aerospace applications has led to commissioning the development of a ruggedized FOSS system for spaceflight through the NASA Launch Services Program (LSP) at the NASA Kennedy Space Center (KSC) (Merritt Island, Florida). In this paper, a ruggedized FOSS suitable for a launch environment is discussed in detail. Thermal analysis and enclosure design will be discussed as well as environmental testing such as shock, random vibration, thermal vacuum, and electromagnetic interference/electromagnetic compatibility (EMI/EMC). With all relevant environmental testing completed, a ruggedized FOSS unit has successfully passed all testing and is now deemed space-launch ready.

Allen R. Parker, Jr↗

Thermal links and position resolution in multi-absorber hydra microcalorimeters

The “hydra” style of position-sensitive, multi-absorber microcalorimeter is used in some imaging x-ray spectroscopy detector arrays to thermally multiplex multiple pixels to one sensor, thereby enabling readout of larger arrays for a given number of sensor readout channels. We describe the benefit of choosing a set of thermal conductance values for the links between absorbers and sensor such that the probability of misidentifying the absorber hit location is minimized while still achieving a specified x-ray energy resolution for all pixels. We illustrate the benefit of this approach as applied in our current prototype 25-pixel hydra magnetic microcalorimeter arrays for the Lynx x-ray astrophysics mission concept.

microcalorimeter↗

Validation of Multisystem Countermeasures Protocol for Spaceflight during Antarctica Winter-over at Palmer Station (Palmer Countermeasures)

Exploration-class missions beyond the Van Allen belt to the Moon and then Mars will begin soon. Low-Earth orbital spaceflight results in the persistent perturbation of the human immune system, characterized by reductions in T and NK cell function, altered cytokine profiles, and the reactivation of latent herpesviruses. While these alterations have not caused widespread clinical issues, some crewmembers experience immune-related adverse events, including manifestations of symptomatic herpes viral reactivation, allergy, and respiratory distress. Because future deep-space exploration missions will be of unprecedented duration, it is reasonable to hypothesize that the immune perturbations observed aboard International Space Station (ISS) will intensify during longer missions in deep space, thereby placing crewmembers at elevated clinical risk. Thus, it is imperative to preserve the immune vigilance of astronauts by developing a countermeasure strategy. Of all the Earth analogs studied to date, an Antarctica winter-over (AWO) mission most closely reproduces the spaceflight experience: prolonged deployment, extreme environment, circadian misalignment, isolation, station lifestyle, and personal risk. The US maintains three primary stations in Antarctica: South Pole Station, McMurdo, and Palmer. Previous studies suggest that stations located near the interior of Antarctica (South Pole, McMurdo) have confounding effects on the immune system due to persistent hypobaric hypoxia. Thus, it was hypothesized that winter-over at a coastal station (Palmer) would be more akin to spaceflight due to its normoxic but still extreme environment. Therefore, AWO at Palmer Station was chosen as the platform for testing and validating the effectiveness of a NASA multi-system countermeasures protocol designed for deep space missions. The array of countermeasure protocols and monitoring methods deployed for each AWO will consist of diet modifications, nutritional supplementation, prescribed aerobic and resistive exercise, and a protocol of stress relieving virtual reality exercises. A multitude of biological sample types, including blood, saliva, and hair will be collected in tandem with the countermeasures in order to examine the combined effectiveness of the countermeasures. Samples and logs from subjects will be transported from Palmer Station to Johnson Space Center for further processing and distribution to co-investigators at the end of each winter-over. Extracted samples will be analyzed by appropriate testing platforms (Multiplex, qPCR, ELISA, etc.) to monitor alterations in leukocyte distribution, T cell and NK function, cytokine profiles, reactivation of latent herpesviruses, and nutritional factors. The data collected will be compared to a control year in which no countermeasures were deployed to evaluate the overall effectiveness of the analog and to validate the candidate immune countermeasure strategy. With the completion of the Antarctica Winter-Over (WO) 2022 control year, samples for 13 subjects have been successfully returned from Antarctica to NASA/JSC for further processing and distribution to Co-Investigators. WO 2023, the first countermeasure year, has also commenced with 11 subject consenting and performing their base line data collections (BDC) held in Chile. Another 5 subjects, who were already stationed at Palmer Station, Antarctica, joined as participates in the investigation. These 5 subjects were consented, but no BDC was able to be collected due to their joining in-mission. Therefore, there will be a total of 16 subjects participating in Antarctica's 2023 Winter-Over.

Cody L Gutierrez↗

Development of Concurrent Artificially-Intelligent Spectrometry and Adaptive Lidar System (CASALS) for Swath Mapping From Space

We present the design and performance of a Concurrent Artificially-intelligent Spectrometry and Adaptive Lidar System (CASALS) for 3D imaging from Space. With a single fast wavelength tuning laser, CASALS accomplishes a 1,200 resolvable spots swath mapping by grating dispersion wavelength steering. Any subset of these 1,200 spots can be selected by wavelength switching. The validation operating principle was accomplished and reported in IGASS-2022. With configurable base design, we report the designs and progress of the CASALS airplane campaign with 256 contiguous ground spots. It is accomplished with a single fast tuning lase at 1040-nm, 1.152MHz tuning rate, and pulse modulated 2-ns on each wavelength. Return pulses are mapped to an eight-pixel detector array with single-photon sensitivity. The lidar returns are time-multiplexed to two outputs that are digitized with two 1-GSPS-digitizer. A grating spectrometer rejects solar background noise spatially and spectrally. We are developing a 1040-nm CASALS intended for multiple LEO orbit missions: Earth Venture Mission on ESPA Grande, STV Mission on ESPA Grande SmallSat, STV Mission on spacecraft equivalent to ICESat power (SWaP,) and splitting the laser beam requires higher laser pulse energy.

ranging lidar↗

Optimized Entanglement Distribution Among Quantum Memories

We evaluate entanglement distribution performance when an optimized quantum memory encoding method is used for two sources, the standard spontaneous parametric down conversion source and the zero added loss multiplexing source. Physical non-idealities are considered.

Entanglement distribution↗

Development of the Microcalorimeter Array for the Line Emission Mapper (LEM) X-Ray Probe

The Line Emission Mapper (LEM) is a proposed NASA probe-class mission designed to study the formation of structure in the Universe. LEM will have a 14k pixel array of transition-edge sensor (TES) microcalorimeters that provide a spectral resolution of < 2.5 eV and a bandpass of 0.2-2 keV. In this paper, we report on the status and plan for continued development of the LMS microcalorimeter. This includes details of the TES and x-ray absorber design, and the measured performance in prototype arrays. We present a detailed budget for the energy resolution and show how the properties of the LEM pixels are well optimized for the baseline time-division-multiplexing (TDM) that will be used read out the array. Finally, we describe the design and performance of the first full scale LMS arrays which include the necessary mechanical and electrical interfaces needed for LEM and are a precursor to an engineering model detector.

Stephen J Smith↗

Validation of Multisystem Countermeasures Protocol for Spaceflight during Antarctica Winter-over at Palmer Station (Palmer Countermeasures)

Stressors associated with spaceflight induce persistent immune compromise in astronauts which increase subclinical latent virus reactivation. In select crews, adverse clinical events have been documented. Antarctica winter-over (AWO) mission most closely reproduces these mission stressors: prolonged deployment, extreme environment, circadian misalignment, isolation, station lifestyle, and personal risk. The US maintains three primary stations in Antarctica: South Pole Station, McMurdo, and Palmer. Previous studies suggest that stations located near the interior of Antarctica (South Pole, McMurdo) have confounding effects on the immune system due to persistent hypobaric hypoxia. We hypothesized that winter-over at a coastal station (Palmer) would be more akin to spaceflight due to its normoxic but still extreme environment. Therefore, AWO at Palmer Station was selected, and validated in a pilot study [2], as the platform for testing and validating the effectiveness of an immune-restorative countermeasure protocol designed for deep space missions. Specifics include diet modifications, nutritional supplementation (vitamin D, probiotic, etc.), prescribed aerobic and resistive exercise, and a protocol of stress relieving virtual reality exercises. A multitude of biological sample types, including blood, saliva, and hair will be collected in tandem with the countermeasures in order to examine the combined effectiveness of the countermeasures. Samples and logs from subjects will be transported from Palmer Station to Johnson Space Center for further processing and distribution to co-investigators at the end of each winter-over. Extracted samples will be analyzed by appropriate testing platforms (Multiplex, qPCR, ELISA, etc.) to monitor alterations in leukocyte distribution, T cell and NK function, cytokine profiles, reactivation of latent herpesviruses, and nutritional factors. The data collected will be compared to a control year in which no countermeasures were deployed to evaluate the overall effectiveness of the analog and to validate the candidate immune countermeasure strategy. AWO 2023 concluded with the 4th in-mission timepoint conducted in September 2023. Samples for 16 subjects, including blood, saliva, hair, surveys, and PCR data, were all successfully returned from Antarctica to NASA/JSC mid-November 2023. Samples have since been distributed to co-investigators for further processing and analysis. With the completion of the first countermeasure year, preliminary data on the effectiveness of the deep-space protocol is being evaluated, however, no conclusions can be drawn yet until the completion of the second AWO countermeasure year, AWO 2024. AWO 2024 commenced in late-March 2024, with 13 subjects consenting and performing their baseline data collections (BDCs). Unique to the 2024 deployment, NSF lifted certain COVID restrictions and rallied the crewmembers in Punta Arenas, Chile. All NSF activities were transferred to this location and NASA was allowed, for the first time, to perform consent briefings, baseline samplings and training in person. This augment greatly increased the likelihood of success for the overwinter activities.

Cody L Gutierrez↗

Validation of Multisystem Countermeasures Protocol for Spaceflight during Antarctica Winter-over at Palmer Station (Palmer Countermeasures)

Stressors associated with spaceflight induce persistent immune compromise in astronauts which increase subclinical latent virus reactivation. In select crews, adverse clinical events have been documented. Antarctica winter-over (AWO) mission most closely reproduces these mission stressors: prolonged deployment, extreme environment, circadian misalignment, isolation, station lifestyle, and personal risk. The US maintains three primary stations in Antarctica: South Pole Station, McMurdo, and Palmer. Previous studies suggest that stations located near the interior of Antarctica (South Pole, McMurdo) have confounding effects on the immune system due to persistent hypobaric hypoxia. We hypothesized that winter-over at a coastal station (Palmer) would be more akin to spaceflight due to its normoxic but still extreme environment. Therefore, AWO at Palmer Station was selected, and validated in a pilot study, as the platform for testing and validating the effectiveness of an immune-restorative countermeasure protocol designed for deep space missions. Specifics include diet modifications, nutritional supplementation (vitamin D, probiotic, etc.), prescribed aerobic and resistive exercise, and a protocol of stress relieving virtual reality exercises. A multitude of biological sample types, including blood, saliva, and hair will be collected in tandem with the countermeasures in order to examine the combined effectiveness of the countermeasures. Samples and logs from subjects will be transported from Palmer Station to Johnson Space Center for further processing and distribution to co-investigators at the end of each winter-over. Extracted samples will be analyzed by appropriate testing platforms (Multiplex, qPCR, ELISA, etc.) to monitor alterations in leukocyte distribution, T cell and NK function, cytokine profiles, reactivation of latent herpesviruses, and nutritional factors. The data collected will be compared to a control year in which no countermeasures were deployed to evaluate the overall effectiveness of the analog and to validate the candidate immune countermeasure strategy. AWO 2023 concluded with the 4th in-mission timepoint conducted in September 2023. Samples for 16 subjects, including blood, saliva, hair, surveys, and PCR data, were all successfully returned from Antarctica to NASA/JSC mid-November 2023. Samples have since been distributed to co-investigators for further processing and analysis. With the completion of the first countermeasure year, preliminary data on the effectiveness of the deep-space protocol is being evaluated, however, no conclusions can be drawn yet until the completion of the second AWO countermeasure year, AWO 2024. AWO 2024 commenced in late-March 2024, with 13 subjects consenting and performing their baseline data collections (BDCs). Unique to the 2024 deployment, NSF lifted certain COVID restrictions and rallied the crewmembers in Punta Arenas, Chile. All NSF activities were transferred to this location and NASA was allowed, for the first time, to perform consent briefings, baseline samplings and training in person. This augment greatly increased the likelihood of success for the overwinter activities.

Cody L Gutierrez↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The E989 Muon g-2 experiment at Fermilab aims to measure the anomalous magnetic moment, a$_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $\omega_a$, and the average magnetic field in terms of the equivalent, free proton Larmor frequency, $\omega_p$. The measurement of $\omega_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration in terms of $\omega_p$. A crucial element for the multi-step measurement of $\omega_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluid delivery manifolds and microfluidic systems

Embodiments of fluid distribution manifolds, cartridges, and microfluidic systems are described herein. Fluid distribution manifolds may include an insert member and a manifold base and may define a substantially closed channel within the manifold when the insert member is press-fit into the base. Cartridges described herein may allow for simultaneous electrical and fluidic interconnection with an electrical multiplex board and may be held in place using magnetic attraction.

42 ENGINEERING↗

Cyclic Prefix Direct Sequence Spread Spectrum Capacity Analysis

Cyclic Prefix Direct Sequence Spread Spectrum (CP-DSSS) is a novel waveform that has the potential to solve 5G objectives such as ultra reliable low latency communication (URLLC) and massive machine Type Communication (mMTC). This paper analyzes the capacity of the CP-DSSS waveform in comparison with Orthogonal Frequency Domain Multiplexing OFDM). CP-DSSS can be optimized to achieve the same capacity as OFDM when optimized by the water-filling algorithm. A significant advantage for CP-DSSS is that this capacity can be achieved with all symbols being transmitted with the same effective rate. As a result, stronger forward error correction codes can be used in a CP-DSSS implementation compared to an OFDM implementation with resource block constraints. In addition, the applicability of CP-DSSS as a waveform for a secondary network operating in the same frequency band as the primary network is discussed.

5G and Beyond Communications↗