Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Investigation of E{sub 1}(LO) phonon-plasmon coupled modes and critical points in In{sub 1-x}Ga{sub x}N thin films by optical reflectance measurements

Low energy optical modes of molecular beam epitaxy-grown In{sub 1-x}Ga{sub x}N thin films with 0<=x<=0.6 are investigated using infrared reflectance measurements. We found that the reflectance of the films for wave vectors in the range from 600 to 800 cm{sup -1} is determined by the high energy E{sub 1}(LO)-plasmon coupled modes. In the higher energy regime of the UV-visible reflectance spectrum of InN, critical points with energies 4.75, 5.36, and 6.12 eV belonging to A and B structures are observed. The energies of these critical points increase with increasing values of x, similar to the band gap energy of these films.

36 MATERIALS SCIENCE↗

Enhanced light scattering in Si nanostructures produced by pulsed laser irradiation

An innovative method for Si nanostructures (NS) fabrication is proposed, through nanosecond laser irradiation (λ = 532 nm) of thin Si film (120 nm) on quartz. Varying the laser energy fluences (425–1130 mJ/cm{sup 2}) distinct morphologies of Si NS appear, going from interconnected structures to isolated clusters. Film breaking occurs through a laser-induced dewetting process. Raman scattering is enhanced in all the obtained Si NS, with the largest enhancement in interconnected Si structures, pointing out an increased trapping of light due to multiple scattering. The reported method is fast, scalable and cheap, and can be applied for light management in photovoltaics.

36 MATERIALS SCIENCE↗

Ferroelectric nanoscale domains and the 905 K phase transition in SrSnO{sub 3}: A neutron total-scattering study

The 905 K Pnma-Imma phase transition in SrSnO{sub 3} is studied here using a combination of variable-temperature neutron total scattering together with the reverse Monte Carlo (RMC) refinement method. The real-space RMC configurations obtained are analyzed in terms of bond distance and bond-angle distributions, and a geometric algebra approach is used to quantify the associated octahedral-tilting distributions. What emerges from this analysis is that the transition is displacive in nature, in contrast to the results of a recent average-structure investigation in which an order-disorder model was proposed [E. H. Mountstevens et al., Phys. Rev. B 71, 220102(R) (2005)]. Three-dimensional diffuse scattering patterns calculated from the same RMC configurations reveal the existence of an additional disorder mechanism which persists across the Pnma-Imma transition. The ''reflection conditions'' of this diffuse scattering, together with displacement correlation calculations, point to the existence of ferroelectric nanoscale domains within the configurations, which are found to extend across planar regions of approximately 10-15 A ring in diameter.

36 MATERIALS SCIENCE↗

Microbiological Analysis of Mizuna Grown in the Veggie Hardware to Define Critical Control Points and Ensure the Safety of Space Grown Crops

The Veggie facility on the International Space Station has been utilized as a “pick and eat” plant growth system to provide fresh produce for crew consumption. The VEG-04 experiments completed in 2019 examined the effect of red-rich and blue-rich light treatments on the growth of mizuna as well as harvest method and resulting yield. Analysis was performed on plant tissues and associated hardware to evaluate the influence of these experimental variables on the microbial population. VEG-04A plant pillows with pre-planted Mizuna mustard seeds were launched on SpaceX-16 in December 2018. The pillows were initiated, and a single 35-day harvest was performed. Veg 04B pillows were pre-planted with Mizuna seeds and launched on SpaceX-18 in July 2019, initiated and subsequently harvested at days 29, 43 and 58. The crew consumed approximately half of the produce, and the remainder was frozen and returned for analysis. Leaves, swabs, wicking material, substrate, and roots were processed and plated on media for the enumeration and isolation of bacteria and fungi. Isolated bacterial colonies were identified using Biolog Micro ID system or MicroSEQ16S rDNA sequencing technique. Fungal colonies were identified using the MicroSEQ D2 rDNA kit. Sample extracts were plated onto specialized media to identify Escherichia coli/coliforms, Staphylococcus aureus and Salmonella sp. Results indicate that bacterial and fungal counts were higher in plants grown in red-rich lightin VEG-04A, while the opposite was true in the Veg-04B third harvest. Microbial counts increased with the repeated harvest method used in Veg-04B. These data support the understanding of environmental and horticultural practices that can affect the microbiological quality of space-grown produce grown and aid in identification of critical control points for the development of a hazard analysis critical control point plan for ISS-grown crops. This research was co-funded by the NASA’s Human Research Program and Space Biology.

Mary E Hummerick↗

Prevention and Treatment of Functional and Structural Radiation Injury in the Rat Heart by Pentoxifylline and Alpha-Tocopherol

Purpose: Radiation-induced heart disease (RIHD) is a severe side effect of thoracic radiotherapy. This study examined the effects of pentoxifylline (PTX) and {alpha}-tocopherol on cardiac injury in a rat model of RIHD. Methods and Materials: Male Sprague-Dawley rats received fractionated local heart irradiation with a daily dose of 9 Gy for 5 days and were observed for 6 months after irradiation. Rats were treated with a combination of PTX, 100 mg/kg/day, and {alpha}-tocopherol (20 IU/kg/day) and received these compounds either from 1 week before until 6 months after irradiation or starting 3 months after irradiation, a time point at which histopathologic changes become apparent in our model of RIHD. Results: Radiation-induced increases in left ventricular diastolic pressure (in mm Hg: 35 {+-} 6 after sham-irradiation, 82 {+-} 11 after irradiation) were significantly reduced by PTX and {alpha}-tocopherol (early treatment: 48 {+-} 7; late treatment: 53 {+-} 6). PTX and {alpha}-tocopherol significantly reduced deposition of collagen types I (radiation only: 3.5 {+-} 0.2 {mu}m{sup 2} per 100 {mu}m{sup 2}; early treatment: 2.7 {+-} 0.8; late treatment: 2.2 {+-} 0.2) and III (radiation only: 13.9 {+-} 0.8; early treatment: 11.0 {+-} 1.2; late treatment: 10.6 {+-} 0.8). On the other hand, radiation-induced alterations in heart/body weight ratios, myocardial degeneration, left ventricular mast cell densities, and most echocardiographic parameters were not significantly altered by PTX and {alpha}-tocopherol. Conclusions: Treatment with PTX and {alpha}-tocopherol may have beneficial effects on radiation-induced myocardial fibrosis and left ventricular function, both when started before irradiation and when started later during the process of RIHD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postmastectomy Chest Wall Radiation to a Temporary Tissue Expander or Permanent Breast Implant-Is There a Difference in Complication Rates?

Purpose: The purpose of this study was to evaluate the likelihood of complications and cosmetic results among breast cancer patients who underwent modified radical mastectomy (MRM) and breast reconstruction followed by radiation therapy (RT) to either a temporary tissue expander (TTE) or permanent breast implant (PI). Methods and Materials: Records were reviewed of 74 patients with breast cancer who underwent MRM followed by breast reconstruction and RT. Reconstruction consisted of a TTE usually followed by exchange to a PI. RT was delivered to the TTE in 62 patients and to the PI in 12 patients. Dose to the reconstructed chest wall was 50 Gy. Median follow-up was 48 months. The primary end point was the incidence of complications involving the reconstruction. Results: There was no significant difference in the rate of major complications in the PI group (0%) vs. 4.8% in the TTE group. No patients lost the reconstruction in the PI group. Three patients lost the reconstruction in the TTE group. There were excellent/good cosmetic scores in 90% of the TTE group and 80% of the PI group (p = 0.22). On multivariate regression models, the type of reconstruction irradiated had no statistically significant impact on complication rates. Conclusions: Patients treated with breast reconstruction and RT can experience low rates of major complications. We demonstrate no significant difference in the overall rate of major or minor complications between the TTE and PI groups. Postmastectomy RT to either the TTE or the PI should be considered as acceptable treatment options in all eligible patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time- and Dose-Dependency of Radiographic Normal Tissue Changes of the Lung After Stereotactic Radiotherapy

Purpose: Normal tissue changes (NTC) of the normal lung parenchyma are commonly seen after stereotactic single-dose radiotherapy (radiosurgery) of lung tumors. The aim of this study was to investigate the extent and dynamics of NTCs after radiosurgery. Methods and Materials: Fifty lung tumors in 49 patients were treated with radiosurgery. Follow-up CTs were anatomically matched to the treatment planning CTs, incorporating the treatment plan and enabling spatial correlation of initial radiation dose distribution and subsequent NTCs of the lung. Lung parenchyma was divided into nine areas of different radiation dose exposures (range, 6-35 Gy). Areas were investigated and compared at different time points according to the development of NTCs. Results: Twenty-six patients developed NTCs during follow-up. The evaluation of the dependency of the extent of NTCs on the amount of radiation dose lead to a linear model for the fixed effects: Fraction of reacting volume =Intercept{sub T} +0.0208 * Dose ('Dose' should be given in Gy). Dose had a slope of 0.0208 (fraction of normal tissue reaction/Gy) (SE 0.000804, p < 0.0001), implying a significant correlation between dose level and the extent of NTC. Conclusion: For radiosurgery of lung tumors, a significant correlation of radiation dose and the extent of NTCs could be demonstrated. Using the introduced formula, a preview on the extent of NTCs to develop in normal lung parenchyma according to the dose level can be performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Six Degrees-of-Freedom Prostate and Lung Tumor Motion Measurements Using Kilovoltage Intrafraction Monitoring

Purpose: Tumor positional uncertainty has been identified as a major issue that deteriorates the efficacy of radiation therapy. Tumor rotational movement, which is not well understood, can result in significant geometric and dosimetric inaccuracies. The objective of this study was to measure 6 degrees-of-freedom (6 DoF) prostate and lung tumor motion, focusing on the more novel rotation, using kilovoltage intrafraction monitoring (KIM). Methods and Materials: Continuous kilovoltage (kV) projections of tumors with gold fiducial markers were acquired during radiation therapy for 267 fractions from 10 prostate cancer patients and immediately before or after radiation therapy for 50 fractions from 3 lung cancer patients. The 6 DoF motion measurements were determined from the individual 3-dimensional (3D) marker positions, after using methods to reject spurious and smooth noisy data, using an iterative closest point algorithm. Results: There were large variations in the magnitude of the tumor rotation among different fractions and patients. Various rotational patterns were observed. The average prostate rotation angles around the left-right (LR), superior-inferior (SI), and anterior-posterior (AP) axes were 1.0 ± 5.0°, 0.6 ± 3.3°, and 0.3 ± 2.0°, respectively. For 35% of the time, the prostate rotated more than 5° about the LR axis, indicating the need for intrafractional adaptation during radiation delivery. For lung patients, the average LR, SI, and AP rotation angles were 0.8 ± 4.2°, −0.8 ± 4.5°, and 1.7 ± 3.1°, respectively. For about 30% of the time, the lung tumors rotated more than 5° around the SI axis. Respiration-induced rotation was detected in 2 of the 3 lung patients. Conclusions: The prostate and lung tumors were found to undergo rotations of more than 5° for about a third of the time. The lung tumor data represent the first 6 DoF tumor motion measured by kV images. The 6 DoF KIM method can enable rotational and translational adaptive radiation therapy and potentially reduce treatment margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-E-15: Design of a Water Calorimeter for Dual Use in An Integrated MRI-Linac and Gamma-Knife

Purpose: To design a water calorimeter for dual use in an integrated MRI-linac and Gamma-Knife. In calorimetry, dose to water is measured based on the assumption that energy absorbed in a sensitive volume is completely converted to temperature rise {sub (}ΔΤ{sub )} according to the specific heat capacity of the medium c: D=c*ΔT*k, where k is heat transfer correction factor and compensates for heat gain or loss at point of measurement due to conductive effects. Methods: A commercial finite element method software package was used to model four different water calorimeter designs. The long term (48 h) thermal stability of each design was accurately modeled, and the optimization of the final design was based on evaluation of the standard deviation of k for ten consecutive irradiation runs (lower standard deviation translates to greater thermal stability). Several insulator materials of varying thicknesses were investigated, and a sensitivity study of thermal stability to variations in ambient temperature fluctuations was undertaken. Specifically, we evaluated the effect of possible variations in coolant temperature circulating around the calorimeter tank in several scenarios (constant, slowly increasing, or fluctuating). Results: Due to MRI-compatibility requirements, the calorimeter is to be built entirely out of plastic. Among all insulation materials tested, solid state aerogel-based insulation resulted in least heat loss and thermal stability. The final design is cylindrical on top (to be used upright in MRI-linac) and semi-spherical at bottom (for use in GammaKnife). The range of k was found to be 1.002 ± 0.013 (k = 1), comparable with a k of 1.002 ± 0.014 for typical water calorimeters used in high energy beams. A long term stability of 0.36 µK/hr was evaluated. Conclusion: Optimization of a water calorimeter design for dual use in MRI-linac and Gamma-Knife has been completed and the device is currently in production. Supported by NSERC RGPIN 435608.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for Measuring Collimator-Pointing Sensitivity to Temperature Changes

For a variety of applications, it is important to measure the sensitivity of the pointing of a beam emerging from a collimator, as a function of temperature changes. A straightforward method for carrying out this measurement is based on using interferometry for monitoring the changes in beam pointing, which presents its own problems. The added temperature dependence and complexity issues relating to using an interferometer are addressed by not using an interferometer in the first place. Instead, the collimator is made part of an arrangement that uses a minimum number of low-cost, off-the-shelf materials and by using a quad diode to measure changes in beam pointing. In order to minimize the influence of the test arrangement on the outcome of the measurement, several steps are taken. The collimator assembly is placed on top of a vertical, 1-m-long, fused silica tube. The quad diode is bonded to a fused silica bar, which, in turn, is bonded to the lower end of the fused silica tube. The lower end of the tube rests on a self-aligning support piece, while the upper end of the tube is kept against two rounded setscrew tips, using a soft rubber string. This ensures that very little stress is applied to the tube as the support structure changes dimensions due to thermal expansion. Light is delivered to the collimator through a bare fiber in order to minimize variable bending torque caused by a randomly relaxing, rigid fiber jacket. In order to separate the effect of temperature on the collimator assembly from the effect temperature has on the rest of the setup, multiple measurements are taken with the collimator assembly rotated from measurement to measurement. Laboratory testing, with 1-m spacing between the collimator and the quad diode, has shown that the sensitivity of the arrangement is better than 100 nm rms, over time spans of at least one hour, if the beam path is protected from atmospheric turbulence by a tube. The equivalent sensitivity to detecting changes in pointing angle is 100 nanoradians.

Abramovici, Alex↗

Method of reducing temperature in high-speed photography

A continuing problem in high-speed motion picture photography is adequate lighting and the associated temperature rise. Large temperature rises can damage subject matter and make recording of the desired images impossible. The problem is more severe in macrophotography because of bellows extension and the necessary increase in light. This report covers one approach to reducing the initial temperature rise: the use of filters and heat-absorbing materials. The accompanying figures provide the starting point for selecting distance as a function of light intensity and determining the associated temperature rise. Using these figures will allow the photographer greater freedom in meeting different photographic situations.

Walker, E. D.↗

Localizing Holes as Polarons and Predicting Band Gaps, Defect Levels, and Delithiation Energies of Solid-State Materials with a Local Exchange-Correlation Functional

Here, we assess the performance of seven exchange–correlation functionals (some with and some without a Hubbard U correction) for their ability (i) to predict band gaps of silicon, diamond, and Li-ion battery cathode materials, (ii) to localize hole polarons and predict delithiation energies in Li-ion battery cathode materials, and (iii) to predict transition levels of charge carriers of doped silicon and diamond. Both local and hybrid exchange–correlation functionals were tested. The local functionals tend to underestimate band gaps and delocalize polarons. The hybrid functionals very often give a good description of both properties, but they may not be practical for calculations involving large unit cells, large ensembles, or dynamics, and therefore a local functional with a Hubbard U correction is often used (giving the method called DFT+U), where the value of a parameter U is adjusted according to the system and the property being investigated. Keeping in mind the importance of computational cost and the undesirability of having to adjust an empirical parameter for each system or property of interest, we recently developed a local functional, namely HLE17, to try to accurately predict band gaps and excitation energies, and we validated it using mostly main-group solids and molecules. Here we test the performance of HLE17 for its ability to predict band gaps and localize polarons in other solid-state materials, and we compare its performance to that of popular local functionals (PBE, PBEsol, and TPSS), a range-separated hybrid functional with screened exchange (HSE06), and DFT+U. We find that HLE17 predicts more accurate band gaps than other local functionals and can localize holes as polarons, which other local functionals usually fail to do, and for a number of cases it is comparable in performance quality to Hubbard-corrected functionals without the need for system-specific parametrization and to hybrid functionals without the high cost. Because HLE17 does not predict accurate lattice constants, we use the single-point method of quantum chemistry, where the geometry is optimized with one functional and the band gap is calculated with HLE17, or we perform calculations with the lattice constants obtained by TPSS and both the fractional intracell coordinates and the electronic structure obtained by HLE17 (a new method denoted HLE17\\TPSS). In particular, we performed calculations by HLE17//TPSS, HLE17//HSE06, HLE17//DFT+U, and HLE17\\TPSS, and these methods usually agree well with each other and give values similar to experiment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design Report on the MiniFuel Instrumented Test Apparatus for Understanding Radiation Effects

Most nuclear fuels irradiations at Oak Ridge National Laboratory (ORNL) over the past decade have been conducted using MiniFuel—a static capsule design employing subscale fuel specimens to collect separate-effects irradiated fuel performance data. Irradiation conditions for MiniFuel experiments are predicted pre-test using reactor physics, and thermal models are verified post-irradiation via SiC dilatometry and various spectrometry methods. Relevant fuel performance parameters are also observed post-irradiation in a hot cell, thereby providing a single data point for each parameter representing the cumulative effects of the irradiation conditions. Substantially more data can be harvested from a single test and within a shorter duration by instrumenting irradiation vehicles and measuring desired quantities in situ. This report presents the design and analysis of the MiniFuel INstrumented Irradiation Test Apparatus for Understanding Radiation Effects (MINITAURE)—an instrumented test rig based on the separate-effects MiniFuel concept that aims to capture fission gas release (FGR) and thermal conductivity degradation of fuel specimens during irradiation in the High Flux Isotope Reactor (HFIR). MINITAURE will be integrated with the Materials Irradiation Facility (MIF) located in the HFIR building outside the reactor containment. The MIF will act as the instrumentation and control center for the experiment, enabling real-time feedback from in situ sensors and control of irradiation temperatures via a gas delivery system. Two unique capsule designs were developed to capture each phenomenon: the thermal conductivity capsule, which uses a thermopile method to estimate fuel specimen thermal conductivity, and the fission gas release capsule, which will have continuous flowing gas communication to high-purity germanium detectors that are housed in the MIF for monitoring FGR. This report details the reactor physics and heat transfer modeling activities that were used to inform the experiment design and predict capsule performance. It also describes out-of-pile activities conducted to stand up this new capability and verify the measurement techniques. Modeling efforts to date have demonstrated the feasibility of the in situ measurement techniques and supported the development of the MINITAURE assembly configuration. Out-of-pile testing of the thermal conductivity measurement shows promise in capturing relative changes in thermal conductivity. However, significant errors exist in the measured absolute value, posing a need for further refinement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of the Chlorination Products of Zirconium Alloys used for Nuclear Fuel Cladding

The United States produces over 2000 metric tons of used nuclear fuel material per year, of which 25% is irradiated fuel cladding, and it is expected to increase for the next 50 years. Previous simulation studies have shown that in the irradiated cladding, the major activation products found are {sup 125}Sb, {sup 60}Co, and {sup 99m}Nb, and the major fission product found is {sup 137}Cs. These radioisotopes make it impossible to treat the cladding as low level waste. A chlorination process has been proposed for zirconium reprocessing as it has been proven more efficient than previous mechanical processes, redox processes, and other chemical methods (e.g. iodination). In the chlorination process, zirconium alloy cladding reacts with Cl{sub 2} at 350- 380 deg. C to produce mainly ZrCl{sub 4}. The zirconium tetrachloride has a relatively low sublimation point (331 deg. C) that allows its separation from other products, and so it can be treated as low level waste for disposal or recycling. However, previous work has observed element impurities (iron, tin, chromium, cesium, antimony, and niobium) in the recovered ZrCl{sub 4}, meaning that additional steps are necessary in a chlorination process previous to the reduction of ZrCl, to metallic Zr. The emphasis of this research summary is on the progress that has been made to isolate and characterize the impurities produced after chlorination of three previously characterized non-irradiated zirconium alloys (Zircaloy-2, Zircaloy-4, and a commercial Zr-Nb alloy) widely used as cladding materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determining Physical Parameters of Shielded Uranium using Gamma Spectroscopy and the Differential Evolution Adaptive Metropolis (DREAM) Method

Inverse radiation transport is a well-established method for determining unknown parameters within a system that exhibits particle leakage. Two significant challenges of solving inverse transport problems are (1) to determine multiple unknowns without false convergence on local minima and (2) to be able to quantify uncertainty. It was recently demonstrated that the Differential Evolution Adaptive Metropolis (DREAM) method effectively meets both of these challenges. In Bledsoe's 2014 article, the DREAM method was only applied to numerical test cases in which measured data were simulated using MCNP. This paper provides results of research conducted at Oak Ridge National Laboratory (ORNL) in which DREAM was applied to two-dimensional inverse transport problems using real-world measurements. The DREAM method uses a Markov chain Monte Carlo (MCMC) method to obtain a posterior distribution of unknown parameters. In this application, the posterior distribution is determined by using a uniform prior distribution and a likelihood function. The goal of the inverse problem is to find the regions in which the likelihood function is at or near its maximum. In the traditional MCMC approach, a single Markov chain is employed. In practice, MCMC approaches have a high acceptance rate to solutions that are near the current point of sampling, but they exhibit slow convergence to solutions far from the sampling point. The DREAM algorithm was designed to alleviate this issue by initiating multiple Markov chains and using the differential evolution algorithm to generate trial points for each chain. Solving for the mass of radioactive material within a voluminous source is a challenging problem for gamma-ray spectroscopy. Inverse gamma-ray transport can supply a range of possible material compositions, but reducing the differences between predicted and actual measurements can lead to false results. DREAM is a rapid technique for determining the most likely solution for several unknown parameters in an inverse transport problem. This work applies DREAM to a series of gamma spectroscopy experiments performed at ORNL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and application of processing and process control for nano-composite materials for lithium ion batteries (CRADA Final Report)

Oak Ridge National Laboratory and A123 Systems, Inc. collaborated on this project to develop a better understanding, quality control procedures, and safety testing for A123 System’s nanocomposite separator (NCS) technology which is a cell based patented technology and separator. NCS demonstrated excellent performance. x3450 prismatic cells were shown to survive >8000 cycles (1C/2C rate) at room temperature with greater than 80% capacity retention with only NCS present as an alternative to conventional polyolefin. However, for a successful commercialization, the coating conditions required to provide consistent and reliable product had not been optimized and QC techniques for being able to remove defective material before incorporation into a cell had not been developed. The work outlined in this report addresses these latter two points. First, experiments were conducted to understand temperature profiles during the different drying stages of the NCS coating when applied to both anode and cathode. One of the more interesting discoveries of this study was the observation of the large temperature decrease experienced by the wet coating between the end of the infrared (IR) drying stage and the beginning of the exposure to the convection drying oven. This is not a desirable situation as the temperature gradient could have a deleterious effect on coating quality. Based on this and other experimental data a radiative transfer model was developed for IR heating that also included a mass transfer module for drying. This will prove invaluable for battery coating optimization especially where IR drying is being employed. A stress model was also developed that predicts that under certain drying conditions tensile stresses are formed in the coating which could lead to cracking that is sometimes observed after drying is complete. Prediction of under what conditions these stresses form is vital to improving coating quality. In addition to understanding the drying process other parameters such as slurry quality and equipment optimization were examined. Removal of particles and gels by filtering, control of viscosity by %solids and mixing adjustments, removal of trapped gas in the slurry and modification of coater speed and slot die gap were all found to be important for producing uniform and flaw-free coatings. Second, an in-line Hi-Pot testing method has been developed specifically for NCS that will enable detection of coating flaws that could lead to soft or hard electrical shorts within the cell. In this way flawed material can be rejected before incorporation into the cell thus greatly reducing the amount of scrap that is generated. Improved battery safety is an extremely important benefit of NCS. Evaluation of battery safety is usually accomplished by conducting a variety of tests including nail penetration, hot box, over charge, etc. For these tests entire batteries must be built but the resultant temperature and voltage responses reveal little about the breakdown mechanism. In this report is described a pinch test which is used to evaluate NCS quality at various stages including coated anode and cathode as well as assembled cell. Coupled with post-microscopic examination of the damaged ‘pinch point’ test data can assist in the coating optimization from an improved end-use standpoint. As a result of this work two invention disclosures, one for optimizing drying methodology and the other for an in-line system for flaw detection, have been filed. In addition, 2 papers are being written for submission to peer-reviewed journals.

25 ENERGY STORAGE↗

Clopidogrel Responsiveness in Patients Undergoing Peripheral Angioplasty

Purpose: To investigate the incidence and clinical significance of platelet responsiveness in patients receiving clopidogrel after peripheral angioplasty procedures. Materials and Methods: This prospective study included patients receiving antiplatelet therapy with clopidogrel 75 mg after infrainguinal angioplasty or stenting and who presented to our department during routine follow-up. Clopidogrel responsiveness was tested using the VerifyNow P2Y12 Assay. Patients with residual platelet reactivity units (PRU) {>=} 235 were considered as nonresponders (NR group NR), whereas patients with PRU < 235 were considered as normal (responders [group R]). Primary end points were incidence of resistance to clopidogrel and target limb reintervention (TLR)-free survival, whereas secondary end points included limb salvage rates and the identification of any independent predictors influencing clinical outcomes. Results: In total, 113 consecutive patients (mean age 69 {+-} 8 years) with 139 limbs were enrolled. After clopidogrel responsiveness analysis, 61 patients (53.9 %) with 73 limbs (52.5 %) were assigned to group R and 52 patients (46.1 %) with 66 limbs (47.5 %) to group NR. Mean follow-up interval was 27.7 {+-} 22.9 months (range 3-95). Diabetes mellitus, critical limb ischemia, and renal disease were associated with clopidogrel resistance (Fisher's exact test; p < 0.05). According to Kaplan-Meier analysis, TLR-free survival was significantly superior in group R compared with group NR (20.7 vs. 1.9 %, respectively, at 7-year follow-up; p = 0.001), whereas resistance to clopidogrel was identified as the only independent predictor of decreased TLR-free survival (hazard rate 0.536, 95 % confidence interval 0.31-0.90; p = 0.01). Cumulative TLR rate was significantly increased in group NR compared with group R (71.2 % [52 of 73] vs. 31.8 % [21 of 66], respectively; p < 0.001). Limb salvage was similar in both groups. Conclusion: Clopidogrel resistance was related with significantly more repeat interventions after peripheral angioplasty procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗