Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “linearity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Extending the low-temperature operation of sodium metal batteries combining linear and cyclic ether-based electrolyte solutions

Nonaqueous sodium-based batteries are ideal candidates for the next generation of electrochemical energy storage devices. However, despite the promising performance at ambient temperature, their low-temperature (e.g., < 0 °C) operation is detrimentally affected by the increase in the electrolyte resistance and solid electrolyte interphase (SEI) instability. Here, to circumvent these issues, we propose specific electrolyte formulations comprising linear and cyclic ether-based solvents and sodium trifluoromethanesulfonate salt that are thermally stable down to –150 °C and enable the formation of a stable SEI at low temperatures. When tested in the Na||Na coin cell configuration, the low-temperature electrolytes enable long-term cycling down to –80 °C. Via ex situ physicochemical (e.g., X-ray photoelectron spectroscopy, cryogenic transmission electron microscopy and atomic force microscopy) electrode measurements and density functional theory calculations, we investigate the mechanisms responsible for efficient low-temperature electrochemical performance. We also report the assembly and testing between –20 °C and –60 °C of full Na||Na 3 V 2 (PO 4 ) 3 coin cells. The cell tested at –40 °C shows an initial discharge capacity of 68 mAh g –1 with a capacity retention of approximately 94% after 100 cycles at 22 mA g –1 .

25 ENERGY STORAGE↗

Megavolt bremsstrahlung measurements from linear induction accelerators demonstrate possible use as a FLASH radiotherapy source to reduce acute toxicity

Abstract Recent studies indicate better efficacy and healthy tissue sparing with high dose-rate FLASH radiotherapy (FLASH-RT) cancer treatment. This technique delivers a prompt high radiation dose rather than fractional doses over time. While some suggest thresholds of > 40 Gy s −1 with a maximal effect at > 100 Gy s −1 , accumulated evidence shows that instantaneous dose-rate and irradiation time are critical. Mechanisms are still debated, but toxicity is minimized while inducing apoptosis in malignant tissue. Delivery technologies to date show that a capability gap exists with clinic scale, broad area, deep penetrating, high dose rate systems. Based on these trends, if FLASH-RT is adopted, it may become a dominant approach except in the least technologically advanced countries. The linear induction accelerator (LIA) developed for high instantaneous and high average dose-rate, species independent charged particle acceleration, has yet to be considered for this application. We review the status of LIA technology, explore the physics of bremsstrahlung-converter-target interactions and our work on stabilizing the electron beam. While the gradient of the LIA is low, we present our preliminary work to improve the gradient by an order of magnitude, presenting a point design for a multibeam FLASH-RT system using a single accelerator for application to conformal FLASH-RT.

42 ENGINEERING↗

Double Higgs production in the Two Higgs Doublet Model at the linear collider

We study double Higgs-strahlung production at the future Linear Collider in the framework of the Two Higgs Doublet Models through the following channels: e{sup +}e{sup -}{yields}{phi}{sub i}{phi}{sub j}Z, {phi}{sub i} = h deg., H deg., A deg. All these processes are sensitive to triple Higgs couplings. Hence observations of them provide information on the triple Higgs couplings that help reconstructing the scalar potential. We discuss also the double Higgs-strahlung e{sup +}e{sup -}{yields}h deg. h deg. Z in the decoupling limit where h deg. mimics the SM Higgs boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical Scheme for Viability Computation Using Randomized Technique with Linear Programming

We deal with the problem of computing viability sets for nonlinear continuous or hybrid systems. Our main objective is to beat the curse of dimensionality, that is, we want to avoid the exponential growth of required computational resource with respect to the dimension of the system. We propose a randomized approach for viability computation: we avoid griding the state-space, use random extraction of points instead, and the computation of viable set test is formulated as a classical feasibility problem. This algorithm was implemented successfully to linear and nonlinear examples. We provide comparison of our results with results of other method.

99 GENERAL AND MISCELLANEOUS↗

Numerical study of a linear accelerator using laser-generated proton beams as a source

The injection of laser-generated protons through conventional drift tube linear accelerators (linacs) has been studied numerically. For this, we used the parameters of the proton source produced by ultraintense lasers, i.e., with an intrinsic high beam quality. The numerical particle tracing code PARMELA[L. M. Young and J. H. Billen, LANL Report No. LA-UR-96-1835, 2004] is then used to inject experimentally measured laser-generated protons with energies of 7{+-}0.1 MeV and rms un-normalized emittance of 0.180 mm mrad into one drift tube linac tank that accelerated them to more than 14 MeV. The simulations exhibit un-normalized emittance growths of 8 in x direction and 22.6 in y direction, with final emittances lower than those produced using conventional sources, allowing a potential luminosity gain for the final beam. However, the simulations also exhibit a limitation in the allowed injected proton charge as, over 0.112 mA, space charge effect worsens significantly the beam emittance.

43 PARTICLE ACCELERATORS↗

Conceptual design of International Linear Collider damping ring wiggler based on a hybrid technology

A magnetic design of a failure-free damping ring wiggler with 100% duty factor, 55.6 mm gap, and field exceeding 1.6 T is proposed. The insertion device is based on permanent magnets and specially shimmed poles that capable to meet the requirements of the International Linear Collider (ILC) damping rings (including positron one), with field quality and gap comparable to that projected for ILC using superconducting wiggler. Performance improvement of the modified hybrid design is attained due to yoke reduction down to six separated strips and maximized packaging of the midgrade (or high-grade) parallelepiped magnet blocks surrounding the Permendur poles. Economical efficiency is demonstrated on the base of calculated amount of magnetic material. A cryogenic variant of the hybrid design may certainly provide good sustainability to harsh radiation environment and further enhancement of the design efficiency within the state of the art.

43 PARTICLE ACCELERATORS↗

Design considerations for a laser-plasma linear collider

Design considerations for a next-generation electron-positron linear collider based on laser-plasma-accelerators are discussed. Several of the advantages and challenges of laser-plasma-based accelerator technology are addressed. An example of the parameters for a 1 TeV laser-plasma-based collider is presented.

43 PARTICLE ACCELERATORS↗

Measurements and effects of backstreaming ions produced at bremsstrahlung converter target in Dragon-I linear induction accelerator

Positive ions released from x-ray converter target impacted by electron beam of millimeter spot size can be trapped and accelerated in the incident beam's potential well. As the ions move upstream, the beam will be pinched first and then defocused at the target. Four Faraday cups are used to collect backstreaming ions produced at the bremsstrahlung converter target in Dragon-I linear induction accelerator (LIA). Experimental and theoretical results show that the backstreaming positive ions density and velocity are about 10{sup 21}/m{sup 3} and 2-3 mm/{mu}s, respectively. The theoretical and experimental results of electron beam envelope with ions and without ions are also presented. The discussions show that the backstreaming positive ions will not affect the electron beam focusing and envelope radius in Dragon-I LIA.

43 PARTICLE ACCELERATORS↗

World lays groundwork for future linear collider

With the Large Hadron Collider at CERN finally working, the particle-physics community can now afford to divide its attention between achieving LHC results and preparing for the next machine on its wish list, an electron-positron linear collider. The preparations involve developing and deciding on the technology for such a machine, the mode of its governance, and how to balance regional and global particle- and accelerator-physics programs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation, transport, and detection of linear accelerator based femtosecond-terahertz pulses

The generation and detection of intense terahertz (THz) radiation has drawn a great attention recently. The dramatically enhanced energy and peak electric field of the coherent THz radiation can be generated by coherent superposition of radiated fields emitted by ultrafast electron bunches. The femtosecond (fs)-THz beamline construction at the Pohang Accelerator Laboratory (PAL) was completed in the end of 2009. The fs-THz beamline at PAL can supply ultrafast and intense fs-THz radiation from a 75 MeV linear accelerator. The radiation is expected to have frequency up to 3 THz ({approx}100 cm{sup -1}) and the pulse width of <200 fs with pulse energy up to 10 {mu}J. This intense THz source has great potential for applications in nonlinear optical phenomena and fields such asmaterial science, biomedical science, chemistry, and physics, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetry of a Small-Animal Irradiation Model using a 6 MV Linear Accelerator

A custom made rat-like phantom was used to measure dose distributions using a 6 MV linear accelerator. The phantom has air cavities that simulate the lungs and cylindrical inserts that simulate the backbone. The calculated dose distributions were obtained with the BrainScan v.5.31 TPS software. For the irradiation two cases were considered: (a) near the region where the phantom has two air cavities that simulate the lungs, and (b) with an entirely uniform phantom. The treatment plan consisted of two circular cone arcs that imparted a 500 cGy dose to a simulated lesion in the backbone. We measured dose distributions using EBT2 GafChromic film and an Epson Perfection V750 scanner working in transmission mode. Vertical and horizontal profiles, isodose curves from 50 to 450 cGy, dose and distance to agreement (DTA) histograms and Gamma index were obtained to compare the dose distributions using DoseLab v4.11. As a result, these calculations show very good agreement between calculated and measured dose distribution in both cases. With a 2% 2 mm criteria 100% of the points pass the Gamma test for the uniform case, while 98.9% of the points do it for the lungs case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Versatile Low Level RF System For Linear Accelerators

The Low Level RF (LLRF) system is the source of all of the rf signals required for an rf linear accelerator. These signals are amplified to drive accelerator and buncher cavities. It can even provide the synchronizing signal for the rf power for a synchrotron. The use of Direct Digital Synthesis (DDS) techniques results in a versatile system that can provide multiple coherent signals at the same or different frequencies with adjustable amplitudes and phase relations. Pulsing the DDS allows rf switching with an essentially infinite on/off ratio. The LLRF system includes a versatile phase detector that allows phase-locking the rf frequency to a cavity at any phase angle over the full 360 deg. range. With the use of stepper motor driven slug tuners multiple cavity resonant frequencies can be phase locked to the rf source frequency. No external phase shifters are required and there is no feedback loop phase setup required. All that is needed is to turn the frequency feedback on. The use of Digital Signal Processing (DSP) allows amplitude and phase control over the entire rf pulse. This paper describes the basic principles of a LLRF system that has been used for both proton accelerators and electron accelerators, including multiple tank accelerators, sub-harmonic and fundamental bunchers, and synchrotrons.

43 PARTICLE ACCELERATORS↗

A Novel Linear Accelerator For Image Guided Radiation Therapy

RadiaBeam is developing a novel linear accelerator which produces both kilovoltage ({approx}100 keV) X-rays for imaging, and megavoltage (6 to 20 MeV) X-rays for therapy. We call this system the DEXITron: Dual Energy X-ray source for Imaging and Therapy. The Dexitron is enabled by an innovation in the electromagnetic design of the linac, which allows the output energy to be rapidly switched from high energy to low energy. In brief, the method involves switching the phase of the radiofrequency (RF) power by 180 degrees at some point in the linac such that, after that point, the linac decelerates the beam, rather than accelerating it. The Dexitron will have comparable cost to other linacs, and avoids the problems associated with current IGRT equipment.

43 PARTICLE ACCELERATORS↗

Absolute energy calibration of FD by an electron linear accelerator for Telescope Array

The primary energy of the ultra-high energy cosmic rays(UHECR) are measured with the number of fluorescence photons which are detected with fluorescence detectors(FD) in the Telescope Array experiment(TA). Howevery since there is large uncertinty as 19% in the measurement of the energy scale, the most important theme is improvement of the energy calibration. The electron light source(ELS) is a small electron linear accelerator for new energy calibration. The ELS is located 100 m far from the FD station, and injects electron beam which is accelerated to 40 MeV energy into the sky. We can calibrate the FD energy scale by detection the air shower directly which is generated by the electron beam. The ELS was developed in KEK Japan, and moved to the TA site in March 2009. We started the beam operation in September 2010, in consequence we detected the air shower which was generated by electron beam in the air. The output kinetic energy of the electron beam was 41.1 MeV, we adjusted the output charge from 40 to 140 pC/pulse. We expect that we can improve the uncertinty of the energy scale to about 10% with the ELS, futhermore ELS will be a very useful apparatus for R and D of future UHECR observation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of compact linear accelerator in KBSI

The compact linear accelerator using a 28 GHz ECRIS is under construction in KBSI, South Korea. The main capability of this facility is the production of fast neurons for the neutron radiography. The designing of a superconducting magnet, microwave transmission system, beam extraction, and plasma chamber of ECRIS were finished. The nominal axial design fields of the magnets are 3.6 T at injection and 2.2 T at extraction; the nominal radial design field strength at the plasma chamber wall is 2.1 T. We already installed 10 kW, 28 GHz gyrotron, and tested a microwave power from gyrotron using a dummy load. The current status will be discussed in this paper.

43 PARTICLE ACCELERATORS↗

Upgrade of the MIT Linear Electrostatic Ion Accelerator (LEIA) for nuclear diagnostics development for Omega, Z and the NIF

The MIT Linear Electrostatic Ion Accelerator (LEIA) generates DD and D{sup 3}He fusion products for the development of nuclear diagnostics for Omega, Z, and the National Ignition Facility (NIF). Significant improvements to the system in recent years are presented. Fusion reaction rates, as high as 10{sup 7} s{sup -1} and 10{sup 6} s{sup -1} for DD and D{sup 3}He, respectively, are now well regulated with a new ion source and electronic gas control system. Charged fusion products are more accurately characterized, which allows for better calibration of existing nuclear diagnostics. In addition, in situ measurements of the on-target beam profile, made with a CCD camera, are used to determine the metrology of the fusion-product source for particle-counting applications. Finally, neutron diagnostics development has been facilitated by detailed Monte Carlo N-Particle Transport (MCNP) modeling of neutrons in the accelerator target chamber, which is used to correct for scattering within the system. These recent improvements have resulted in a versatile platform, which continues to support the existing nuclear diagnostics while simultaneously facilitating the development of new diagnostics in aid of the National Ignition Campaign at the National Ignition Facility.

43 PARTICLE ACCELERATORS↗

Experimental investigation on focusing characteristics of a He-Ne laser using circular Fresnel zone plate for high-precision alignment of linear accelerators

We experimentally investigate the focusing characteristics of a He-Ne laser at the focal region for the high-precision alignment of long-distance linear accelerators using a circular Fresnel zone plate. The laser wave passing through the Fresnel zone plate having a focal length of 66.7 m propagates for a 268-m-long distance at atmospheric pressure. A new laser-based alignment system using Fresnel zone plates as the alignment targets is discussed. The transverse displacement of the focused spot of the laser is measured as a function of the displacement of the target by a detector installed at the focal point. Systematic studies on the focusing characteristics and alignment precision have been successfully conducted in this experiment. The experimental results are in good agreement with theoretical calculations, and the alignment precision of the target is determined to be less than {+-}30 {mu}m. In this study, we perform a detailed experimental investigation on the laser propagation and focusing characteristics using the circular Fresnel zone plate at the focal region along with theoretical calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗