Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Magnetic microscopic imaging with an optically pumped magnetometer and flux guides

Here, by combining an optically pumped magnetometer (OPM) with flux guides (FGs) and by installing a sample platform on automated translation stages, we have implemented an ultra-sensitive FG-OPM scanning magnetic imaging system that is capable of detecting magnetic fields of ~20 pT with spatial resolution better than 300 μm (expected to reach ~10 pT sensitivity and ~100 μm spatial resolution with optimized FGs). As a demonstration of one possible application of the FG-OPM device, we conducted magnetic imaging of micron-size magnetic particles. Magnetic imaging of such particles, including nano-particles and clusters, is very important for many fields, especially for medical cancer diagnostics and biophysics applications. For rapid, precise magnetic imaging, we constructed an automatic scanning system, which holds and moves a target sample containing magnetic particles at a given stand-off distance from the FG tips. We show that the device was able to produce clear microscopic magnetic images of 10 μm-size magnetic particles. In addition, we also numerically investigated how the magnetic flux from a target sample at a given stand-off distance is transmitted to the OPM vapor cell.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-DE-BRA-03: TOPAS-edu: A Window Into the Stochastic World Through the TOPAS Tool for Particle Simulation

Purpose: The stochastic nature of the subatomic world presents a challenge for physics education. Even experienced physicists can be amazed at the varied behavior of electrons, x-rays, protons, neutrons, ions and the any short-lived particles that make up the overall behavior of our accelerators, brachytherapy sources and medical imaging systems. The all-particle Monte Carlo particle transport tool, TOPAS Tool for Particle Simulation, originally developed for proton therapy research, has been repurposed into a physics teaching tool, TOPAS-edu. Methods: TOPAS-edu students set up simulated particle sources, collimators, scatterers, imagers and scoring setups by writing simple ASCII files (in the TOPAS Parameter Control System format). Students visualize geometry setups and particle trajectories in a variety of modes from OpenGL graphics to VRML 3D viewers to gif and PostScript image files. Results written to simple comma separated values files are imported by the student into their preferred data analysis tool. Students can vary random seeds or adjust parameters of physics processes to better understand the stochastic nature of subatomic physics. Results: TOPAS-edu has been successfully deployed as the centerpiece of a physics course for master’s students at Queen’s University Belfast. Tutorials developed there takes students through a step by step course on the basics of particle transport and interaction, scattering, Bremsstrahlung, etc. At each step in the course, students build simulated experimental setups and then analyze the simulated results. Lessons build one upon another so that a student might end up with a full simulation of a medical accelerator, a water-phantom or an imager. Conclusion: TOPAS-edu was well received by students. A second application of TOPAS-edu is currently in development at Zurich University of Applied Sciences, Switzerland. It is our eventual goal to make TOPAS-edu available free of charge to any non-profit organization, along with associated tutorial materials developed by the TOPAS-edu community. Work supported in part by the U.S. Department of Energy under contract number DE-AC02-76SF00515. B. Villagomez-Bernabe is supported by CONACyT (Mexican Council for Science and Technology) project 231844.

60 APPLIED LIFE SCIENCES↗

International Space Station Instmments Collect Imagery of Natural Disasters

A new focus for utilization of the International Space Station (ISS) is conducting basic and applied research that directly benefits Earth's citizenry. In the Earth Sciences, one such activity is collecting remotely sensed imagery of disaster areas and making those data immediately available through the USGS Hazards Data Distribution System, especially in response to activations of the International Charter for Space and Major Disasters (known informally as the "International Disaster Charter", or IDC). The ISS, together with other NASA orbital sensor assets, responds to IDC activations following notification by the USGS. Most of the activations are due to natural hazard events, including large floods, impacts of tropical systems, major fires, and volcanic eruptions and earthquakes. Through the ISS Program Science Office, we coordinate with ISS instrument teams for image acquisition using several imaging systems. As of 1 August 2013, we have successfully contributed imagery data in support of 14 Disaster Charter Activations, including regions in both Haiti and the east coast of the US impacted by Hurricane Sandy; flooding events in Russia, Mozambique, India, Germany and western Africa; and forest fires in Algeria and Ecuador. ISS‐based sensors contributing data include the Hyperspectral Imager for the Coastal Ocean (HICO), the ISERV (ISS SERVIR Environmental Research and Visualization System) Pathfinder camera mounted in the US Window Observational Research Facility (WORF), the ISS Agricultural Camera (ISSAC), formerly operating from the WORF, and high resolution handheld camera photography collected by crew members (Crew Earth Observations). When orbital parameters and operations support data collection, ISS‐based imagery adds to the resources available to disaster response teams and contributes to the publicdomain record of these events for later analyses.

Evans, C. A.↗

MO-B-BRB-03: Systems Engineering Tools for Treatment Planning Process Optimization in Radiation Medicine

The radiotherapy treatment planning process has evolved over the years with innovations in treatment planning, treatment delivery and imaging systems. Treatment modality and simulation technologies are also rapidly improving and affecting the planning process. For example, Image-guided-radiation-therapy has been widely adopted for patient setup, leading to margin reduction and isocenter repositioning after simulation. Stereotactic Body radiation therapy (SBRT) and Radiosurgery (SRS) have gradually become the standard of care for many treatment sites, which demand a higher throughput for the treatment plans even if the number of treatments per day remains the same. Finally, simulation, planning and treatment are traditionally sequential events. However, with emerging adaptive radiotherapy, they are becoming more tightly intertwined, leading to iterative processes. Enhanced efficiency of planning is therefore becoming more critical and poses serious challenge to the treatment planning process; Lean Six Sigma approaches are being utilized increasingly to balance the competing needs for speed and quality. In this symposium we will discuss the treatment planning process and illustrate effective techniques for managing workflow. Topics will include: Planning techniques: (a) beam placement, (b) dose optimization, (c) plan evaluation (d) export to RVS. Planning workflow: (a) import images, (b) Image fusion, (c) contouring, (d) plan approval (e) plan check (f) chart check, (g) sequential and iterative process Influence of upstream and downstream operations: (a) simulation, (b) immobilization, (c) motion management, (d) QA, (e) IGRT, (f) Treatment delivery, (g) SBRT/SRS (h) adaptive planning Reduction of delay between planning steps with Lean systems due to (a) communication, (b) limited resource, (b) contour, (c) plan approval, (d) treatment. Optimizing planning processes: (a) contour validation (b) consistent planning protocol, (c) protocol/template sharing, (d) semi-automatic plan evaluation, (e) quality checklist for error prevention, (f) iterative process, (g) balance of speed and quality Learning Objectives: Gain familiarity with the workflow of modern treatment planning process. Understand the scope and challenges of managing modern treatment planning processes. Gain familiarity with Lean Six Sigma approaches and their implementation in the treatment planning workflow.

60 APPLIED LIFE SCIENCES↗

Background Oriented Schlieren Using Celestial Objects

The present invention is a system and method of visualizing fluid flow around an object, such as an aircraft or wind turbine, by aligning the object between an imaging system and a celestial object having a speckled background, taking images, and comparing those images to obtain fluid flow visualization.

Haering, Edward, A., Jr.↗

Double-Diffusive Convection During Growth of Halides and Selenides

Heavy metal halides and selenides have unique properties which make them excellent materials for chemical, biological and radiological sensors. Recently it has been shown that selenohalides are even better materials than halides or selenides for gamma-ray detection. These materials also meet the strong needs of a wide band imaging technology to cover ultra-violet (UV), midwave infrared wavelength (MWIR) to very long wavelength infrared (VLWIR) region for hyperspectral imager components such as etalon filters and acousto-optic tunable filters (AO). In fact AOTF based imagers based on these materials have some superiority than imagers based on liquid crystals, FTIR, Fabry-Perot, grating, etalon, electro-optic modulation, piezoelectric and several other concepts. For example, broadband spectral and imagers have problems of processing large amount of information during real-time observation. Acousto-Optic Tunable Filter (AOTF) imagers are being developed to fill the need of reducing processing time of data, low cost operation and key to achieving the goal of covering long-wave infrared (LWIR). At the present time spectral imaging systems are based on the use of diffraction gratings are typically used in a pushbroom or whiskbroom mode. They are mostly used in systems and acquire large amounts of hyperspectral data that is processed off-line later. In contrast, acousto-optic tunable filter spectral imagers require very little image processing, providing new strategies for object recognition and tracking. They are ideally suited for tactical situations requiring immediate real-time image processing. But the performance of these imagers depends on the quality and homogeneity of acousto-optic materials. In addition for many systems requirements are so demanding that crystals up to sizes of 10 cm length are desired. We have studied several selenides and halide crystals for laser and AO imagers for MWIR and LWIR wavelength regions. We have grown and fabricated crystals of several materials such as mercurous chloride, mercurous bromide, mercurous iodide, lead chloride lead bromide, lead iodide, thallium arsenic selenide, gallium selenide, zince sulfide zinc selenide and several crystals into devices. We have used both Bridgman and physical vapor transport (PVT) crystal growth methods. In the past have examined PVT growth numerically for conditions where the boundary of the enclosure is subjected to a nonlinear thermal profile. Since past few months we have been working on binary and ternary materials such as selenoiodides, doped zinc sulfides and mercurous chloro bromide and mercurous bromoiodides. In the doped and ternary materials thermal and solutal convection play extremely important role during the growth. Very commonly striations and banding is observed. Our experiments have indicated that even in highly purified source materials, homogeneity in 1-g environment is very difficult. Some of our previous numerical studies have indicated that gravity level less than 10-4 (-g) helps in controlling the thermosolutal convection. We will discuss the ground based growth results of HgClxBr(1-x) and ZnSe growth results for the mm thick to large cm size crystals. These results will be compared with our microgravity experiments performed with this class of materials. For both HgCl-HgBr and ZnS-ZnSe the lattice parameters of the mixtures obey Vagard's law in the studied composition range. The study demonstrates that properties are very anisotropic with crystal orientation, and performance achievement requires extremely careful fabrication to utilize highest figure of merit. In addition, some parameters such as crystal growth fabrication, processing time, resolution, field of view and efficiency will be described based on novel solid solution materials. It was predicted that very similar to the pure compounds solid solutions also have very large anisotropy, and very precise oriented and homogeneous bulk and thin film crystals is required to achieve maximum performance of laser or imagers. Some of the parameters controlling the homogeneity such as thermos-solutal convection driven forces can be controlled in microgravity environments to utilize the benefits of these unique materials.

Singh, N. B.↗

Image quality, meteorological optical range, and fog particulate number evaluation using the Sandia National Laboratories fog chamber

The evaluation of optical system performance in fog conditions typically requires field testing. This can be challenging due to the unpredictable nature of fog generation and the temporal and spatial nonuniformity of the phenomenon itself. We describe the Sandia National Laboratories fog chamber, a new test facility that enables the repeatable generation of fog within a 55 m×3 m×3 m (L×W×H) environment, and demonstrate the fog chamber through a series of optical tests. These tests are performed to evaluate system image quality, determine meteorological optical range (MOR), and measure the number of particles in the atmosphere. Relationships between typical optical quality metrics, MOR values, and total number of fog particles are described using the data obtained from the fog chamber and repeated over a series of three tests.

47 OTHER INSTRUMENTATION↗

Direct imaging of planetary systems around nearby stars

It is shown that by utilizing a space-borne telescope it may be possible to directly image planetary systems around the nearest stars. Direct imaging, while limited to the nearest stars, would provide a great deal of information on the planet, over and above the planet's orbital elements - estimates of the planet's size and rotation rate, and the presence or absence of an atmosphere are all possible if light from the planet can be separated from light from the star. It is shown that a Jupiter-like planet would be detectable around several of the nearest stars.

Davies, D. W.↗

Comparison of 3-D Bubble Reconstruction Algorithms

Obtaining 3-D bubble shape is important in studying bubble dynamics in two-phase flows, as well as in conducting high-fidelity measurement for code validation applications. With accurate shape information of individual bubbles, the time-averaged parameters including void fraction, interfacial area concentration and Sauter mean diameter can be obtained precisely. Such information will also benefit the development of advanced models of hydrodynamic forces such as the drag force and lift force, which are sensitive to the shape and size of bubbles. Limited by the optical property of gas-liquid system, the silhouette of a bubble along the camera axis is what one can obtain from typical high speed imaging systems. Assumptions have to be made to obtain the 3-D bubble shape from the 2-D images. In this paper, three different bubble reconstruction algorithms, using one or two camera views, are examined to assess their performances in the reconstruction process. (authors)

42 ENGINEERING↗

Ocular screening tests of elementary school children

This report presents an analysis of 507 abnormal retinal reflex images taken of Huntsville kindergarten and first grade students. The retinal reflex images were obtained by using an MSFC-developed Generated Retinal Reflex Image System (GRRIS) photorefractor. The system uses a 35 mm camera with a telephoto lens with an electronic flash attachment. Slide images of the eyes were examined for abnormalities. Of a total of 1835 students screened for ocular abnormalities, 507 were found to have abnormal retinal reflexes. The types of ocular abnormalities detected were hyperopia, myopia, astigmatism, esotropia, exotropia, strabismus, and lens obstuctions. The report shows that the use of the photorefractor screening system is an effective low-cost means of screening school children for abnormalities.

Richardson, J.↗

Snapshot multispectral imaging using a diffractive optical network

Abstract Multispectral imaging has been used for numerous applications in e.g., environmental monitoring, aerospace, defense, and biomedicine. Here, we present a diffractive optical network-based multispectral imaging system trained using deep learning to create a virtual spectral filter array at the output image field-of-view. This diffractive multispectral imager performs spatially-coherent imaging over a large spectrum, and at the same time, routes a pre-determined set of spectral channels onto an array of pixels at the output plane, converting a monochrome focal-plane array or image sensor into a multispectral imaging device without any spectral filters or image recovery algorithms. Furthermore, the spectral responsivity of this diffractive multispectral imager is not sensitive to input polarization states. Through numerical simulations, we present different diffractive network designs that achieve snapshot multispectral imaging with 4, 9 and 16 unique spectral bands within the visible spectrum, based on passive spatially-structured diffractive surfaces, with a compact design that axially spans ~72 λ m , where λ m is the mean wavelength of the spectral band of interest. Moreover, we experimentally demonstrate a diffractive multispectral imager based on a 3D-printed diffractive network that creates at its output image plane a spatially repeating virtual spectral filter array with 2 × 2 = 4 unique bands at terahertz spectrum. Due to their compact form factor and computation-free, power-efficient and polarization-insensitive forward operation, diffractive multispectral imagers can be transformative for various imaging and sensing applications and be used at different parts of the electromagnetic spectrum where high-density and wide-area multispectral pixel arrays are not widely available.

36 MATERIALS SCIENCE↗

Active Millimeter-Wave and Sub-Millimeter-Wave Imaging for Security Applications

Active imaging at millimeter and sub-millimeter wavelengths has been developed for security applications including concealed weapon detection. The physical properties that affect imaging performance are discussed along with a review of the current state-of-the-art and future potential for security imaging systems.

imaging↗

Correlation between human observer performance and model observer performance in differential phase contrast CT

Purpose: With the recently expanding interest and developments in x-ray differential phase contrast CT (DPC-CT), the evaluation of its task-specific detection performance and comparison with the corresponding absorption CT under a given radiation dose constraint become increasingly important. Mathematical model observers are often used to quantify the performance of imaging systems, but their correlations with actual human observers need to be confirmed for each new imaging method. This work is an investigation of the effects of stochastic DPC-CT noise on the correlation of detection performance between model and human observers with signal-known-exactly (SKE) detection tasks.Methods: The detectabilities of different objects (five disks with different diameters and two breast lesion masses) embedded in an experimental DPC-CT noise background were assessed using both model and human observers. The detectability of the disk and lesion signals was then measured using five types of model observers including the prewhitening ideal observer, the nonprewhitening (NPW) observer, the nonprewhitening observer with eye filter and internal noise (NPWEi), the prewhitening observer with eye filter and internal noise (PWEi), and the channelized Hotelling observer (CHO). The same objects were also evaluated by four human observers using the two-alternative forced choice method. The results from the model observer experiment were quantitatively compared to the human observer results to assess the correlation between the two techniques.Results: The contrast-to-detail (CD) curve generated by the human observers for the disk-detection experiments shows that the required contrast to detect a disk is inversely proportional to the square root of the disk size. Based on the CD curves, the ideal and NPW observers tend to systematically overestimate the performance of the human observers. The NPWEi and PWEi observers did not predict human performance well either, as the slopes of their CD curves tended to be steeper. The CHO generated the best quantitative agreement with human observers with its CD curve overlapping with that of human observer. Statistical equivalence between CHO and humans can be claimed within 11% of the human observer results, including both the disk and lesion detection experiments.Conclusions: The model observer method can be used to accurately represent human observer performance with the stochastic DPC-CT noise for SKE tasks with sizes ranging from 8 to 128 pixels. The incorporation of the anatomical noise remains to be studied.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An all-sky X-ray monitor for the UK-5 satellite.

An X-ray imaging system using a pin-hole camera and a position sensitive proportional counter at the image plane has been designed for an all-sky X-ray monitor for UK-5 satellite. This high-sensitivity device with real-time coverage of the entire celestial sphere would aid in programming satellite maneuvers such that transient events in the X-ray sky could be investigated in detail by the other primary satellite experiments. Discussion of design criteria for the camera geometry, the position sensitive proportional detector, and electronics to handle the data is presented in this paper.

Desai, U. D.↗

Frontiers for geological remote sensing from space; Geosat Workshop, 4th, Flagstaff, AZ, June 12-17, 1983, Report

Consideration is given to: the applications of near-infrared spectroscopy to geological reconnaissance and exploration from space; imaging systems for identifying the spectral properties of geological materials in the visible and near-infrared; and Thematic Mapper (TM) data analysis. Consideration is also given to descriptions of individual geological remote sensing systems, including: GEO-SPAS; SPOT; the Thermal Infrared Multispectral Scanner (TIMS); and the Shuttle Imaging Radars A and B (SIR-A and SIR-B). Additional topics include: the importance of geobotany in geological remote sensing; achromatic holographic stereograms from Landsat MSS data; and the availability and applications of NOAA's non-Landsat satellite data archive.

Henderson, F. B.↗

Orientale and South Pole-Aitken basins on the Moon: Preliminary Galileo imaging results

During the Earth-Moon flyby the Galileo Solid State Imaging System obtained new information on the landscape and physical geology of the Moon. Multicolor Galileo images of the Moon reveal variations in color properties of the lunar surface. Using returned lunar samples as a key, the color differences can be interpreted in terms of variations in the mineral makeup of the lunar rocks and soil. The combined results of Apollo landings and multicolor images from Galileo allow extrapolation of surface composition to areas distant from the landing sites, including the far side invisible from Earth.

Head, J.↗

Tomographic decoding algorithm for a nonoverlapping redundant array

A tomographic reconstruction algorithm is developed for the nonoverlapping redundant array X-ray imaging system whereby the background contributions from out-of-focus planes can be eliminated. The algorithm makes use of two constraints derived from the physical characteristics of the nonoverlapping redundant array system in tandem with the correlation decoding process. It is simple, direct, and noniterative. Tomographic images of computer-generated planar and three-dimensional objects are provided to illustrate the effectiveness of the algorithm.

Yin, Lo I.↗

Qualitative and quantitative imaging in microgravity combustion

An overview of the imaging techniques implemented by researchers in the microgravity combustion program shows that for almost any system, imaging of the flame may be accomplished in a variety of ways. Standard and intensified video, high speed, and infrared cameras and fluorescence, laser schlieren, rainbow schlieren, soot volume fraction, and soot temperature imaging have all been used in the laboratory and many in reduced gravity to make the necessary experimental measurements.

Weiland, Karen J.↗