Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Communicating about bioenergy sustainability

Defining and measuring sustainability of bioenergy systems are difficult because the systems are complex, the science is in early stages of development, and there is a need to generalize what are inherently context-specific enterprises. These challenges, and the fact that decisions are being made now, create a need for improved communications among scientists as well as between scientists and decision makers. In order for scientists to provide information that is useful to decision makers, they need to come to an agreement on how to measure and report potential risks and benefits of diverse energy alternatives, including problems and opportunities in various bioenergy production pathways. Scientists also need to develop approaches that contribute information relevant to policy and decision making. The need for clear communication is especially important at this time when there is a plethora of scientific papers and reports, and it is difficult for the public or decision makers to assess the merits of each analysis. We propose three communication guidelines for scientists whose work can contribute to decision making: (1) relationships between the question and the analytical approach should be clearly defined and make common sense; (2) the information should be presented in a manner that nonscientists can understand; and (3) the implications of methods, assumptions and limitations should be clear. The scientists job is to analyze information in order to build a better understanding of environmental, cultural and socioeconomic aspects of the sustainability of energy alternatives. The scientific process requires transparency, debate, review, and collaboration across disciplines and time. This paper serves as an introduction to the papers in the special issue on Sustainability of Bioenergy Systems: Cradle to Grave because scientific communication is essential to developing more sustainable energy systems. Together these four papers provide a framework under which the effects of bioenergy can be assessed and compared to other energy alternatives in order to foster sustainability.

Benefits↗

Bile Culture and Susceptibility Testing of Malignant Biliary Obstruction via PTBD

Purpose: To assess the information obtained by bile culture and susceptibility testing for malignant biliary obstruction by a retrospective one-center study. Methods: A total of 694 patients with malignant biliary obstruction received percutaneous transhepatic biliary drainage during the period July 2003 to September 2010, and subsequently, bile specimens were collected during the procedure. Among the 694 patients, 485 were men and 209 were women, ranging in age from 38 to 78 years (mean age 62 years). Results: A total of 42.9% patients had a positive bile culture (298 of 694). Further, 57 species of microorganisms and 342 strains were identified; gram-positive bacteria accounted for 50.9% (174 of 342) and gram-negative bacteria accounted for 41.5% (142 of 342) of these strains. No anaerobes were obtained by culture during this study. The most common microorganisms were Enterococcus faecalis (41 of 342, 11.9%), Escherichia coli (34 of 342, 9.9%), Klebsiella pneumoniae (28 of 342, 8.2%), Staphylococcus epidermidis (19 of 342, 5.5%), Enterococcus (18 of 342, 5.3%), and Enterobacter cloacae (16 of 342, 4.7%). The percentage of {beta}-lactamase-producing gram-positive bacteria was 27.6% (48 of 174), and the percentage of gram-negative bacteria was 19.7% (28 of 142). The percentage of enzyme-producing Escherichia coli was 61.7% (21 of 34). Conclusion: The bile cultures in malignant biliary obstruction are different from those in the Tokyo Guidelines and other benign biliary obstruction researches, which indicates that a different antibacterial therapy should be applied. Thus, knowledge of the antimicrobial susceptibility data could aid in the better use of antibiotics for the empirical therapy of biliary infection combined with malignant biliary obstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treating and Downstaging Hepatocellular Carcinoma in the Caudate Lobe with Yttrium-90 Radioembolization

Purpose: This study was designed to determine the technical feasibility, safety, efficacy, and potential to downstage patients to within transplantation criteria when treating patients with hepatocellular carcinoma (HCC) of the caudate lobe using Y90 radioembolization. Methods: During a 4-year period, 8 of 291 patients treated with radioembolization for unresectable HCC had disease involving the caudate lobe. All patients were followed for treatment-related clinical/biochemical toxicities, serum tumor marker response, and treatment response. Imaging response was assessed with the World Health Organization (WHO) and European Association for the Study of the Liver (EASL) classification schemes. Pathologic response was reported as percent necrosis at explantation. Results: Caudate lobe radioembolization was successfully performed in all eight patients. All patients presented with both cirrhosis and portal hypertension. Half were United Network for Organ Sharing (UNOS) stage T3 (n = 4, 50%). Fatigue was reported in half of the patients (n = 4, 50%). One (13%) grade 3/4 bilirubin toxicity was reported. One patient (13%) showed complete tumor response by WHO criteria, and three patients (38%) showed complete response using EASL guidelines. Serum AFP decreased by more than 50% in most patients (n = 6, 75%). Four patients (50%) were UNOS downstaged from T3 to T2, three of who underwent transplantation. One specimen showed histopathologic evidence of 100% complete necrosis, and two specimens demonstrated greater than 50% necrosis. Conclusions: Radioembolization with yttrium-90 appears to be a feasible, safe, and effective treatment option for patients with unresectable caudate lobe HCC. It has the potential to downstage patients to transplantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry

Purpose: The British Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry was produced to provide an audit of current United Kingdom (UK) practice regarding placement and retrieval of IVC filters to address concerns regarding their safety. Methods: The IVC filter registry is a web-based registry, launched by the BSIR on behalf of its membership in October 2007. This report is based on prospectively collected data from October 2007 to March 2011. This report contains analysis of data on 1,434 IVC filter placements and 400 attempted retrievals performed at 68 UK centers. Data collected included patient demographics, insertion and retrieval data, and patient follow-up. Results: IVC filter use in the majority of patients in the UK follows accepted CIRSE guidelines. Filter placement is usually a low-risk procedure, with a low major complication rate (<0.5 %). Cook Gunther Tulip (560 filters: 39 %) and Celect (359 filters: 25 %) filters constituted the majority of IVC filters inserted, with Bard G2, Recovery filters, Cordis Trapease, and OptEase constituting most of the remainder (445 filters: 31 %). More than 96 % of IVC filters deployed as intended. Operator inexperience (<25 procedure) was significantly associated with complications (p < 0.001). Of the IVC filters initially intended for temporary placement, retrieval was attempted in 78 %. Of these retrieval was technically successful in 83 %. Successful retrieval was significantly reduced for implants left in situ for >9 weeks versus those with a shorter dwell time. New lower limb deep vein thrombosis (DVT) and/or IVC thrombosis was reported in 88 patients following filter placement, there was no significant difference of incidence between filter types. Conclusions: This registry report provides interventional radiologists and clinicians with an improved understanding of the technical aspects of IVC filter placement to help improve practice, and the potential consequences of IVC filter placement so that we are better able to advise patients. There is a significant learning curve associated with IVC filter insertion, and when a filter is placed with the intention of removal, procedures should be in place to avoid the patient being lost to follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of TACE in TIPS Patients: Comparison of Treatment Response to Chemoembolization for Hepatocellular Carcinoma in Patients With and Without a Transjugular Intrahepatic Portosystemic Shunt

Purpose: To compare treatment response after transarterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) in patients with and without a transjugular intrahepatic portosystemic shunt (TIPS). Materials and Methods: A retrospective review of patients who underwent conventional TACE for HCC between January 2005 and December 2009 identified 10 patients with patent TIPS. From the same time period, 23 patients without TIPS were selected to control for comparable Model for End-Stage Liver Disease and Child-Pugh-Turcotte scores. The two groups showed similar distribution of Barcelona Clinic Liver Cancer and United Network of Organ Sharing stages. Target HCC lesions were evaluated according to the modified response evaluation criteria in solid tumors (mRECIST) guidelines. Transplantation rate, time to tumor progression, and overall survival (OS) were documented. Results: After TACE, the rate of complete response was significantly greater in non-TIPS patients compared with TIPS patients (74 vs. 30 %, p = 0.03). Objective response rate (complete and partial response) trended greater in the non-TIPS group (83 vs. 50 %, p = 0.09). The liver transplantation rate was 80 and 74 % in the TIPS and non-TIPS groups, respectively (p = 1.0). Time to tumor progression was similar (p = 0.47) between the two groups. OS favored the non-TIPS group (p = 0.01) when censored for liver transplantation. Conclusion: TACE is less effective in achieving complete or partial response using mRECIST criteria in TIPS patients compared with those without a TIPS. Nevertheless, similar clinical outcomes may be achieved, particularly in TIPS patients who are liver-transplantation candidates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Type 2 Endoleaks Post-EVAR: Current Evidence for Rupture Risk, Intervention and Outcomes of Treatment

Type 2 endoleaks (EL2) are the most commonly encountered endoleaks following EVAR. Despite two decades of experience, there remains considerable variation in the management of EL2 with controversies ranging from if to treat, when to treat and how to treat. Here, we summarise the available evidence, describe the treatment techniques available and offer guidelines for management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and Effectiveness of Percutaneously Inserted Peritoneal Ports Compared to Surgically Inserted Ports in a Retrospective Study of 87 Patients with Ovarian Carcinoma over a 10-Year Period

PurposePlacement of peritoneal ports has become a favorable technique for direct chemotherapy infusion in treating peritoneal metastases from ovarian cancer. We aim to outline an approach to the percutaneous insertion of peritoneal ports and to characterize success and complication rates compared to surgically inserted ports.Materials and MethodsRetrospective analysis was collected from 87 patients who had peritoneal port insertion (28 inserted surgically and 59 percutaneously) for treatment of peritoneal metastases from ovarian cancer from July 2004 to July 2014. Complications were classified according to the SIR Clinical Practice Guidelines as major or minor.ResultsTechnical success rates for surgically and percutaneously inserted ports were 100 and 96.7 %, respectively (p = 0.44), with the two percutaneous failures successful at a later date. There were no major complications in either group. Minor complication rates for surgically versus percutaneously inserted ports were 46.4 versus 22.0 %, respectively (p = 0.02). The infection rate for surgically inserted versus percutaneously inserted ports was 14.3 and 0 %, respectively (p = 0.002). The relative risk of developing a complication from percutaneous peritoneal port insertion without ascites was 3.4 (p = 0.04). For percutaneously inserted ports, the mean in-room procedure time was 81 ± 1.3 min and mean fluoroscopy time was 5.0 ± 4.5 min.ConclusionPercutaneously inserted peritoneal ports are a safe alternative to surgically inserted ports, demonstrating similar technical success and lower complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Outcomes After Chemo-Embolization in Patients with Advanced-Stage Hepatocellular Carcinoma: An Evaluation of Different Radiologic Response Criteria

PurposeThe purpse of this study was to evaluate the ability of various radiologic response criteria to predict patient outcomes after trans-arterial chemo-embolization with drug-eluting beads (DEB-TACE) in patients with advanced-stage (BCLC C) hepatocellular carcinoma (HCC).Materials and methodsHospital records from 2005 to 2011 were retrospectively reviewed. Non-infiltrative lesions were measured at baseline and on follow-up scans after DEB-TACE according to various common radiologic response criteria, including guidelines of the World Health Organization (WHO), Response Evaluation Criteria in Solid Tumors (RECIST), the European Association for the Study of the Liver (EASL), and modified RECIST (mRECIST). Statistical analysis was performed to see which, if any, of the response criteria could be used as a predictor of overall survival (OS) or time-to-progression (TTP).Results75 patients met inclusion criteria. Median OS and TTP were 22.6 months (95 % CI 11.6–24.8) and 9.8 months (95 % CI 7.1–21.6), respectively. Univariate and multivariate Cox analyses revealed that none of the evaluated criteria had the ability to be used as a predictor for OS or TTP. Analysis of the C index in both univariate and multivariate models showed that the evaluated criteria were not accurate predictors of either OS (C-statistic range: 0.51–0.58 in the univariate model; range: 0.54–0.58 in the multivariate model) or TTP (C-statistic range: 0.55–0.59 in the univariate model; range: 0.57–0.61 in the multivariate model).ConclusionCurrent response criteria are not accurate predictors of OS or TTP in patients with advanced-stage HCC after DEB-TACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histological Comparison of Kidney Tissue Following Radioembolization with Yttrium-90 Resin Microspheres and Embolization with Bland Microspheres

BackgroundIntra-arterial brachytherapy with yttrium-90 ({sup 90}Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of {sup 90}Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model.MethodsIn each of six pigs, ~25–33 % of the kidney volume was embolized with {sup 90}Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8–9 weeks after the procedure to assess the locations of the microspheres and extent of tissue necrosis from {sup 90}Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed.ResultsKidneys embolized with {sup 90}Y-radioembolization decreased in mass by 30–70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the {sup 90}Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 10{sup 6}) of bland microspheres.ConclusionThis study showed that radioembolization with {sup 90}Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of {sup 90}Y resin microspheres for the localized treatment of kidney tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Recurrent Spontaneous Hemarthrosis After Arthroplasty

PurposeRecurrent spontaneous hemarthrosis is an infrequent but debilitating late complication of joint replacement, affecting up to 1.6% of patients with arthroplasty of the affected joint. Repeated episodes of bleeding result in an inflammatory cascade that further propagates bleeding events. Open and arthroscopic synovectomy are often performed when conservative treatments fail. Transarterial embolization is increasingly utilized as a less invasive option; however, its role is not widely established. We performed a systematic literature review to report the safety and efficacy of transarterial embolization in treating recurrent hemarthrosis in the setting of prior arthroplasty.Materials and MethodsA systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analysis guidelines. A structured search was performed in PubMed, Web of Science, Embase, and SCOPUS databases of patients undergoing embolization for recurrent hemarthrosis after arthroplasty. Patients immediately post-operative, those embolized at first bleeding episode, and those with hemophilia were excluded. Demographic data, clinical information, angiographic findings, treatment, and outcomes were tabulated.ResultsThe search identified 119 titles of which 24 were deemed relevant, comprising 91 patients undergoing 99 embolization procedures. Mean time from prosthesis implantation was 32.2 months. Technical success was 99%. Mean follow-up time was 24.9 months. There were 10 recurrences (10%). Two cases were complicated by joint infection requiring arthroplasty revision.ConclusionsTransarterial embolization for recurrent spontaneous hemarthrosis may be safe and effective in patients having undergone arthroplasty of the affected joint.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing Intra-arterial Complications of Planning and Treatment Angiograms for Y-90 Radioembolization

PurposeTo report hepatic arterial-related complications encountered during planning and treatment angiograms for radioembolization and understand any potential-associated risk factors.Materials and Methods518 mapping or treatment angiograms for 180 patients with primary or metastatic disease to the liver treated by Yttrium-90 radioembolization between 2/2010 and 12/2015 were retrospectively reviewed. Intra-procedural complications were recorded per SIR guidelines. Patient demographics, indication for treatment, prior exposure to chemotherapeutic agents, operator experience, and disease burden were reviewed. Technical variables including type of radioembolic (glass vs. resin microspheres), indication for angiography (mapping vs. treatment), variant anatomy, and attempts at coil embolization were also assessed.ResultsThirteen (13/518, 2.5%) arterial-related complications occurred in 13 patients. All but two complications resulted during transcatheter coil embolization to prevent non-target embolization. Complications included coil migration (n = 6), arterial dissection (n = 2), focal vessel perforation (n = 2), arterial thrombus (n = 2), and vasospasm prohibiting further arterial sub-selection (n = 1). Transarterial coiling was identified as a significant risk factor of complications on both univariate and multivariate regression analysis (odds ratio 7.8, P = 0.004). Usage of resin microspheres was also a significant risk factor (odds ratio 9.5, P = 0.042). No other technical parameters or pre-procedural variables were significant after adjusting for confounding on multivariate analysis (P > 0.05).ConclusionIntra-procedural hepatic arterial complications encountered during radioembolization were infrequent but occurred mainly during coil embolization to prevent non-target delivery to extra-hepatic arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Induced Skin Injuries to Patients: What the Interventional Radiologist Needs to Know

For a long time, radiation-induced skin injuries were only encountered in patients undergoing radiation therapy. In diagnostic radiology, radiation exposures of patients causing skin injuries were extremely rare. The introduction of fast multislice CT scanners and fluoroscopically guided interventions (FGI) changed the situation. Both methods carry the risk of excessive high doses to the skin of patients resulting in skin injuries. In the early nineties, several reports of epilation and skin injuries following CT brain perfusion studies were published. During the same time, several papers reported skin injuries following FGI, especially after percutaneous coronary interventions and neuroembolisations. Thus, CT and FGI are of major concern regarding radiation safety since both methods can apply doses to patients exceeding 5 Gy (National Council on Radiation Protection and Measurements threshold for substantial radiation dose level). This paper reviews the problem of skin injuries observed after FGI. Also, some practical advices are given how to effectively avoid skin injuries. In addition, guidelines are discussed how to deal with patients who were exposed to a potentially dangerous radiation skin dose during medically justified interventional procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reason of Discontinuation After Transarterial Chemoembolization Influences Survival in Patients with Hepatocellular Carcinoma

Background: Transarterial chemoembolization (TACE) for intermediate-stage hepatocellular carcinoma (HCC) is often repeated until unTACEable progression (UTP) occurs. There is little data on the various reasons for stopping TACE and its consequences for subsequent treatment and survival. Aim: To assess the impact of the various reasons of UTP on survival and consequences for subsequent treatments. Methods: Consecutive HCC patients who underwent TACE between 2003 and 2016 were analyzed retrospectively for the reason of TACE discontinuation. UTP was defined according to the EASL guidelines, considering radiological pattern of progression, liver function and performance status (PS). Overall and post-progression survival (OS, PPS) for different reasons of TACE discontinuation were compared. The correlation between time to untreatable progression by chemoembolization (TTUPc) and OS was analyzed. Results: One hundred and sixty-six patients (BCLC-A 40%, BCLC-B 54%, BCLC-C: 7%) were included, undergoing a median of 2 TACE procedures with a median OS of 22.1 months (95% CI 17.4–26.7). UTP occurred in 116 patients (70%) after a median TTUPc of 11.6 months (95% CI 7.8–15.4). There was a strong positive correlation (ρ = 0.816, p < 0.001) between TTUPc and OS. The main reason of UTP was radiological progression (61%), which was mostly intrahepatic (75%). Hepatic decompensation and worsening of PS were independent predictors of OS and PPS. Conclusion: The majority of HCC patients treated with TACE have UTP due to intrahepatic tumor progression with preserved liver function and PS, making them potential candidates for subsequent liver-directed or systemic treatment. TTUPc may be a valuable surrogate endpoint for OS in patients treated with TACE. Level of Evidence: Level II, prognosis study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial (Chemo-)Embolization and Lipiodolization for Hepatic Haemangioma

Background: Transarterial (chemo-)embolization/lipiodolization (TAE/TAL) might be an attractive minimally invasive alternative to surgery in the treatment of symptomatic hepatic haemangioma. This review assesses the efficacy and safety of TAE/TAL as primary treatment for symptomatic hepatic haemangioma. Methods: A systematic search of the literature was performed by two reviewers following the PRISMA guidelines. Cohort studies and case reports were identified; outcomes of cohort studies were reported. The primary efficacy outcome was tumour size before and after TAE/TAL. Improvement of symptoms and quality of life (QoL) were secondary outcomes; the primary safety outcome was complications. The Downs and Black statement was used for quality assessment. Results: Eighteen cohort studies were identified, including 1284 patients. TAE/TAL led to a decrease in tumour size in 1100/1223 (89.9%) patients and to improvement or disappearance of symptoms in 1080/1096 (98.5%) patients. A significant decrease in tumour size from 9.79 ± 0.79 cm to 4.00 ± 1.36 cm (p < 0.001) was shown. Grade 3 complications occurred in 37/1284 (2.9%) patients. Surgical treatment was necessary in 35/1284 (2.7%) of patients. Conclusion: TAE/TAL appears to be a promising and safe treatment to decrease tumour size of hepatic haemangioma. The technique might also provide partial relief of symptoms, although no randomized clinical trials or prospective studies using validated QoL questionnaires are available. TAE/TAL may be considered as a viable alternative to resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Will {sup 177}Lu-DOTATATE Treatment Become More Effective in Salvage Meningioma Patients, When Boosting Somatostatin Receptor Saturation? A Promising Case on Intra-arterial Administration

Somatostatin receptor subtype 2 upregulation is very common in meningiomas, and the use of peptide receptor radionuclide therapy (PRRT) is recognized in recent European guidelines, with long-term stable disease and a long overall survival. Treatment efficacy of radionuclide treatments is correlated with tumour radiation absorbed dose. Meningioma patients with low tumour uptake might benefit less from treatment. Thus, a method to increase tumour uptake in these patients is needed. We describe a case treated with both intravenous and intra-arterial PRRT. Tumour uptake after intravenous PRRT was disappointing, and after intra-arterial administration significantly increased tumour uptake was seen. Patient had a partial response on imaging and reduction in tumour-related complaints. Potentially, intra-arterial administration of PRRT could increase treatment efficacy in meningioma patients. Level of Evidence 5 (case report).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ISRM Suggested Method: Determining Deformation and Failure Characteristics of Rocks Subjected to True Triaxial Compression

The purpose of this ISRM Suggested Method is to introduce a guideline on determining deformation and failure characteristics of rocks subjected to true triaxial compression on different stress path. Here, the true triaxial testing apparatus was reviewed by means of the function and engineering application. Some key techniques, such as stress and strain measurements, and reduction of end effect between specimen and metal platens, preventing metal platens interference, were stated and suggested in detail. Methodology of specimen processing, specimen shape, and testing procedure are characterized. There is an explanation of the experimental data processing on stress–strain curves, strength, and fracture mode.

42 ENGINEERING↗

Electrochemical investigations of high-voltage Na 4 Ni 3 (PO 4 ) 2 P 2 O 7 cathode for sodium-ion batteries

In this work, the electrochemical properties of carbon and reduced graphene-coated Na 4 Ni 3 (PO 4 ) 2 P 2 O 7 materials have been evaluated as high-voltage positive electrodes for sodium-ion batteries. Na 4 Ni 3 (PO 4 ) 2 P 2 O 7 exhibits the highest Ni 3+ /Ni 2+ redox potential of 4.8 V vs. Na + /Na with a theoretical capacity of 127 mAh g -1 . Here, we report on the synthesis and characterizations of Na 4 Ni 3 (PO 4 ) 2 P 2 O 7 -reduced graphene oxide and Na 4 Ni 3 (PO 4 ) 2 P 2 O 7 -carbon composites. The high-voltage dimethyl carbonate–based electrolyte has been chosen to explore the electrochemical properties of Na 4 Ni 3 (PO 4 ) 2 P 2 O 7 as a cathode. Carbon-coated Na 4 Ni 3 (PO 4 ) 2 P 2 O 7 composite electrode delivers a stable discharge capacity of 51 mAh g -1 at 0.1 C rate for 40 cycles which corresponds to a reversible intercalation/de-intercalation of 1.3 sodium ions. The structural deformation has been observed during the charge–discharge process beyond the removal of 1.3 Na + ions and has been confirmed by in situ PXRD measurements. The present results provide a guideline to improve the performances of the high-voltage Na 4 Ni 3 (PO 4 ) 2 P 2 O 7 material for the next generation sodium-ion batteries.

25 ENERGY STORAGE↗

Quantifying the sensitivity of ephemeral streams to land disturbance activities in arid ecosystems at the watershed scale

Large areas of public lands administered by the Bureau of Land Management and located in arid regions of the southwestern United States are being considered for the development of utility-scale solar energy facilities. Land-disturbing activities in these desert, alluvium-filled valleys have the potential to adversely affect the hydrologic and ecologic functions of ephemeral streams. Regulation and management of ephemeral streams typically falls under a spectrum of federal, state, and local programs, but scientifically based guidelines for protecting ephemeral streams with respect to land-development activities are largely nonexistent. This study developed an assessment approach for quantifying the sensitivity to land disturbance of ephemeral stream reaches located in proposed solar energy zones (SEZs). The ephemeral stream assessment approach used publicly-available geospatial data on hydrology, topography, surficial geology, and soil characteristics, as well as highresolution aerial imagery. These datasets were used to inform a professional judgment-based score index of potential land disturbance impacts on selected critical functions of ephemeral streams, including flow and sediment conveyance, ecological habitat value, and groundwater recharge. The total sensitivity scores (sum of scores for the critical stream functions of flow and sediment conveyance, ecological habitats, and groundwater recharge) were used to identify highly sensitive stream reaches to inform decisions on developable areas in SEZs. Total sensitivity scores typically reflected the scores of the individual stream functions; some exceptions pertain to groundwater recharge and ecological habitats. The primary limitations of this assessment approach were the lack of high-resolution identification of ephemeral stream channels in the existing National Hydrography Dataset, and the lack of mechanistic processes describing potential impacts on ephemeral stream functions at the watershed scale.The primary strength of this assessment approach is that it allows watershed-scale planning for low-impact development in arid ecosystems; the qualitative scoring of potential impacts can also be adjusted to accommodate new geospatial data, and to allow for expert and stakeholder input into decisions regarding the identification and potential avoidance of highly sensitive stream reaches.

Arid ecosystems↗