Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid solutions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

On the electromagnetic scattering from infinite rectangular grids with finite conductivity

A variety of methods can be used in constructing solutions to the problem of mesh scattering. However, each of these methods has certain drawbacks. The present paper is concerned with a new technique which is valid for all spacings. The new method involved, called the fast Fourier transform-conjugate gradient method (FFT-CGM), represents an iterative technique which employs the conjugate gradient method to improve upon each iterate, utilizing the fast Fourier transform. The FFT-CGM method provides a new accurate model which can be extended and applied to the more difficult problems of woven mesh surfaces. The formulation of the FFT-conjugate gradient method for aperture fields and current densities for a planar periodic structure is considered along with singular operators, the formulation of the FFT-CG method for thin wires with finite conductivity, and reflection coefficients.

Christodoulou, C. G.↗

Impact of Load Balancing on Unstructured Adaptive Grid Computations for Distributed-Memory Multiprocessors

The computational requirements for an adaptive solution of unsteady problems change as the simulation progresses. This causes workload imbalance among processors on a parallel machine which, in turn, requires significant data movement at runtime. We present a new dynamic load-balancing framework, called JOVE, that balances the workload across all processors with a global view. Whenever the computational mesh is adapted, JOVE is activated to eliminate the load imbalance. JOVE has been implemented on an IBM SP2 distributed-memory machine in MPI for portability. Experimental results for two model meshes demonstrate that mesh adaption with load balancing gives more than a sixfold improvement over one without load balancing. We also show that JOVE gives a 24-fold speedup on 64 processors compared to sequential execution.

Biswas, Rupak↗

Impact of Load Balancing on Unstructured Adaptive Grid Computations for Distributed-Memory Multiprocessors

The computational requirements for an adaptive solution of unsteady problems change as the simulation progresses. This causes workload imbalance among processors on a parallel machine which, in turn, requires significant data movement at runtime. We present a new dynamic load-balancing framework, called JOVE, that balances the workload across all processors with a global view. Whenever the computational mesh is adapted, JOVE is activated to eliminate the load imbalance. JOVE has been implemented on an IBM SP2 distributed-memory machine in MPI for portability. Experimental results for two model meshes demonstrate that mesh adaption with load balancing gives more than a sixfold improvement over one without load balancing. We also show that JOVE gives a 24-fold speedup on 64 processors compared to sequential execution.

Sohn, Andrew↗

Integrated solution techniques for security constrained unit commitment problem

Apparatus and methods are disclosed for solving Mixed Integer Programming (MIP) problems, such as Security Constrained Unit Commitment (SCUC) problems used by power grid authorities to perform day-ahead market clearing. In certain examples, a plurality of threads of a software tool implementing a concurrent optimizer can be executed concurrently and sequentially to generate new solutions to a SCUC problem for an upcoming planning horizon. Data can be shared among the concurrently executing threads, such as intermediate/incumbent solutions and hints regarding the fixing of variables and constraints to reduce the size of the SCUC problem. In some examples, the threads are seeded with historical solutions from prior planning horizons. The software tool can select a best solution from the solutions generated by the threads, and determine dispatch instructions for a device coupled to the power grid for the upcoming planning horizon based at least in part on the selected solution.

Pan, Feng↗

Low-Cost, Easy-To-Integrate and Reliable Grid Energy Storage System with 2 nd Life Lithium Batteries

Batteries retired from electric vehicles have the potential to extend their service as low-cost stationary energy storage systems. However, disperse battery state of health (SOH) and nonuniform battery characters often lead to compromised battery performance and reliability, which greatly hinder their adoption. A Heterogenous Unifying Battery (HUB) system is proposed to stage 2 nd life battery bricks for a period, and enable them to attain improved SOH uniformity, performance, and reliability before being sold for 2 nd life applications, while simultaneously providing grid services. It may offer a technically and economically advantageous solution for the broad utilization of 2 nd use batteries. The goal of this project was to develop the hardware and software that enables the key functions of the HUB system. The first achievement of the project was the development of a 1kW scale proof-of-concept (POC) system, which comprises (i) a modular plug-n-play DC-DC power converter matrix with isolated series output connections to achieve fully independent control of energy flow to each of the connected battery units at low voltage; (ii) enhanced model based control that drives each batteries’ SOH towards uniformity while collectively providing grid energy storage services; and (iii) comprehensive procedures to perform battery diagnostics and prognostics. The second achievement was the development of a 100kW scale HUB system and demonstrated its performance of re-establishing battery SOH uniformity through a period of battery cycling operation. The final HUB system incorporates six DC-DC power converter matrices paired with six battery bricks. Hot swapping of a single battery brick while maintaining consistent system power was demonstrated and system operation was validated to be capable of implementing the approved grid duty cycle and of balancing and conditioning the battery bricks. Through the course of the project, the team optimized the building-block design, form-factors, and adjusted life balancing control. An up-sized 250kW Scale was developed and deployed in October 2022 with pack-level battery form factors, see photo in Figure 1 The third achievement of the project was to perform a techno-economic analysis in order to better understand the cost and revenue potentials in this new “recondition-then-resell" value proposition. The final TEA quantified the economics of new Li-ion batteries as well as second-life batteries processed via reconditioning and traditional binning. Results showed the reconditioned second-life batteries in this project to be economically favorable and viable in grid energy storage markets. The TEA results were published in the Applied Energy journal. The fourth achievement of the project was to deliver a tech-to-market plan for the HUB system that includes funding, IP, and manufacturing strategies. The final T2M plan outlines a business strategy in which the HUB provides a B2B service to EV companies as an alternative to battery recycling that can prepare batteries for 2nd life applications. A company named Smartville Inc. was founded to carry on the commercialization, funding, and technical IP licensing activities of the OPEN project.

25 ENERGY STORAGE↗

Demand-side solutions in the US building sector could achieve deep emissions reductions and avoid over $100 billion in power sector costs

Buildings are energy-intensive and a primary source of US end-use sector carbon emissions. Although building emissions today are 25% below their 2005 peak, far deeper reductions are needed to reach the US 2050 net-zero emissions goal. However, plausible decarbonization pathways that consider both buildings and their interactions with the power grid remain poorly understood. Here, we couple detailed modeling of building energy use and the grid to quantify building decarbonization potential and associated grid impacts. We find up to a 91% reduction in building CO 2 emissions from 2005 levels by 2050 using a portfolio of building efficiency, demand flexibility, and electrification measures alongside rapid grid decarbonization. Building efficiency and flexibility could generate up to $107 billion in annual power system cost savings by 2050, offsetting over a third of the incremental cost of full grid decarbonization. Our results underscore multiple benefits of demand-side solutions for deep decarbonization of US buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Moving Discontinuous Galerkin Method with Interface Condition Enforcement for Reacting Hypersonic Flows

The necessity of enforcing conservation in computational elements or cells (element conservation) for discontinuous solutions is well understood and respected for solving conservation laws in computational fluid dynamics (CFD). In contrast, interface conservation, where the conservation across cell interfaces is enforced, is long ignored, and yet is also ruled and required by the underlying physics just like element conservation. Violation of the interface conservation across discontinuities is the root cause why an exact discontinuous solution can never be achieved in shock capturing methods. The interface conservation is examined and explored in this talk. Moving discontinuous Galerkin (MDG) finite element method with interface conservation enforcement (MDG-ICE) [1],[2] are then presented for solving compressible flow problems with discontinuities based on the observation that the interface conservation can only be satisfied, only when mesh interfaces are aligned with discontinuities. In the MDG-ICE formulation, both conservative quantities and grid geometry are considered as independent variables. A space-time DG formulation is used to solve the multi-material compressible Euler equations in the standard discontinuous solution space and the discrete grid geometry is solved using a variational formulation in a continuous space. A self-adaptive Levenberg-Marquardt method is utilized to solve the resulting over-determined system of nonlinear equations arising from the MDG-ICE formulation. A number of numerical experiments for a variety of flow problems are conducted to assess the accuracy and performance of the MDG-ICE method. Numerical results obtained indicate that the MDG-ICE method is able to deliver the designed order of both h- and p-convergence even for discontinuous solutions, and detect all types of interfaces, via interface condition enforcement and satisfy, via grid movement, the compressible Euler equations and the associated interface condition.

Discontinuous Galekin↗

Calculation of three-dimensional (3-D) internal flow by means of the velocity-vorticity formulation on a staggered grid

A method has been developed to accurately compute the viscous flow in three-dimensional (3-D) enclosures. This method is the 3-D extension of a two-dimensional (2-D) method developed for the calculation of flow over airfoils. The 2-D method has been tested extensively and has been shown to accurately reproduce experimental results. As in the 2-D method, the 3-D method provides for the non-iterative solution of the incompressible Navier-Stokes equations by means of a fully coupled implicit technique. The solution is calculated on a body fitted computational mesh incorporating a staggered grid methodology. In the staggered grid method, the three components of vorticity are defined at the centers of the computational cell sides, while the velocity components are defined as normal vectors at the centers of the computational cell faces. The staggered grid orientation provides for the accurate definition of the vorticity components at the vorticity locations, the divergence of vorticity at the mesh cell nodes and the conservation of mass at the mesh cell centers. The solution is obtained by utilizing a fractional step solution technique in the three coordinate directions. The boundary conditions for the vorticity and velocity are calculated implicitly as part of the solution. The method provides for the non-iterative solution of the flow field and satisfies the conservation of mass and divergence of vorticity to machine zero at each time step. To test the method, the calculation of simple driven cavity flows have been computed. The driven cavity flow is defined as the flow in an enclosure driven by a moving upper plate at the top of the enclosure. To demonstrate the ability of the method to predict the flow in arbitrary cavities, results will he shown for both cubic and curved cavities.

Stremel, Paul M.↗

Minimum detectable activity for tomographic gamma scanning system - 15648

For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each 'view' is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities are at or just above MDA levels. The paper examines methods used to estimate MDAs for a TGS system, and explores possible solutions that can be rigorously defended. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of a multi-dimensional flux function on the monotonicity of Euler and Navier-Stokes computations

A limiting method has been devised for a grid-independent flux function for use with the two-dimensional Euler and Navier-Stokes equations. This limiting is derived from a monotonicity analysis of the model and allows for solutions with reduced oscillatory behavior while still maintaining sharper resolution than a grid-aligned method. In addition to capturing oblique waves sharply, the grid-independent flux function also reduces the entropy generated over an airfoil in an Euler computation and reduces pressure distortions in the separated boundary layer of a viscous-flow airfoil computation. The model has also been extended to three dimensions, although no angle-limiting procedure for improving monotonicity characteristics has been incorporated.

Rumsey, Christopher L.↗

Direct Numerical Simulation of Transitional and Turbulent Flows Over Multi-Scale Surface Roughness—Part I: Methodology and Challenges

Abstract High-fidelity simulation of transitional and turbulent flows over multi-scale surface roughness presents several challenges. For instance, the complex and irregular geometrical nature of surface roughness makes it impractical to employ conforming structured grids, commonly adopted in large-scale numerical simulations due to their high computational efficiency. One possible solution to overcome this problem is offered by immersed boundary methods, which allow wall boundary conditions to be enforced on grids that do not conform to the geometry of the solid boundary. To this end, a three-dimensional, second-order accurate boundary data immersion method (BDIM) is adopted. A novel mapping algorithm that can be applied to general three-dimensional surfaces is presented, together with a newly developed data-capturing methodology to extract and analyze on-surface flow quantities of interest. A rigorous procedure to compute gradient quantities such as the wall shear stress and the heat flux on complex non-conforming geometries is also introduced. The new framework is validated by performing a direct numerical simulation (DNS) of fully developed turbulent channel flow over sinusoidal egg-carton roughness in a minimal-span domain. For this canonical case, the averaged streamwise velocity profiles are compared against results from the literature obtained with a body-fitted grid. General guidelines on the BDIM resolution requirements for multi-scale roughness simulation are given. Momentum and energy balance methods are used to validate the calculation of the overall skin friction and heat transfer at the wall. The BDIM is then employed to investigate the effect of irregular homogeneous surface roughness on the performance of an LS-89 high-pressure turbine blade at engine-relevant conditions using DNS. This is the first application of the BDIM to realize multi-scale roughness for transitional flow in transonic conditions in the context of high-pressure turbines. The methodology adopted to generate the desired roughness distribution and to apply it to the reference blade geometry is introduced. The results are compared to the case of an equivalent smooth blade.

Engineering↗

Power Management Solution for Growing Loads at Airport Rental Facilities

Growing electrical loads across airport facilities could expand beyond local grid capacities. Coordinating flexible loads with generation and storage assets can reduce coincident peaks, mitigate costly upgrades, and reduce electricity costs. This report outlines how The Athena Team has developed a suite of tools, resources, and solutions to leverage load flexibility with energy assets to harness this value potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Semi-Analytical Solution Approach for Solving Constant-Coefficient First-Order Partial Differential Equations

Simulation and control of many dynamic systems involve solving partial differential equations (PDE). This letter proposes a semi-analytical solution (SAS) approach for fast and high-quality solution of first-order PDEs. The region of interest of the studied PDE is divided into a grid, and an SAS is derived for each grid cell in the form of the multivariate polynomials, of which the coefficients are identified using initial value and boundary value conditions. The solutions are solved in a “time-stepping” manner, i.e. within one time step, the coefficients of the SAS are identified and the initial value of the next time step is evaluated. This approach achieves a significantly larger grid cell than the widely used finite difference method, and thus enhances the computational efficiency significantly. Furthermore, the simulation result on the natural gas pipeline model demonstrates the advantages of SAS in accuracy and computational efficiency.

97 MATHEMATICS AND COMPUTING↗

Aqueous electrolyte solutions with anion-bridged secondary solvation sheaths for highly efficient zinc metal batteries

Aqueous zinc metal batteries are low-cost electrochemical devices suitable for safe grid energy storage. However, water decomposition and Zn dendrite formation detrimentally affect their coulombic efficiency. Conventional aqueous electrolyte solutions, with a concentration around 1 M, are cost-effective and exhibit high bulk ionic conductivity but cannot form a stable solid electrolyte interphase. Water-in-salt and aqueous-organic hybrid electrolyte solutions can form robust solid electrolyte interphases, but they are not kinetically efficient and cost-effective. Here, to circumvent these issues, we design variously concentrated aqueous electrolyte solutions using several salts with different donor numbers to extend anion coordination into the secondary solvation sheath. We show that salt-derived anions with donor number > 18 enter the Zn2+ first solvation sheath, and ensure a strong binding energy between the Zn2+(H2O)5-anion nanometric clusters and water molecules in the secondary solvation sheath. In particular, 2 M aqueous electrolyte solutions containing fluorinated anions exhibit bulk ionic conductivities of 26-35 mS cm−1 at 25 °C and form a ZnF2-rich solid electrolyte interphase. When tested in Zn||NaV3O8·1.5H2O Swagelok cells, the best-performing electrolyte solution enables an average coulombic efficiency of 99.99% for 1,000 cycles at 1.5 mA cm−2, corresponding to an initial specific energy of 130 Wh kg−1 (based on the combined weight of the positive and negative electrodes).

25 ENERGY STORAGE↗

A fast Fourier transform-based solver for elastic micropolar composites

This work presents a spectral micromechanical formulation for obtaining the full-field and homogenized response of elastic micropolar composites. The algorithm relies on a coupled set of convolution integral equations for the micropolar strains, where periodic Green’s operators associated with a linear homogeneous reference medium are convolved with functions of the Cauchy and couple stress fields that encode the material’s heterogeneity, as well as any potential material nonlinearity. Such convolution integral equations take an algebraic form in the reciprocal Fourier space that can be solved iteratively. In this vein, the fast Fourier transform (FFT) algorithm is leveraged to accelerate the numerical solution, resulting in a mesh-free formulation in which the periodic unit cell representing the heterogeneous material can be discretized by a regular grid of pixels in two dimensions (or voxels in three dimensions). For verification, the numerical solutions obtained with the micropolar FFT solver are compared with analytical solutions for a matrix with a dilute circular inclusion subjected to plane strain loading. The developed computational framework is then used to study length-scale effects and effective (micropolar) moduli of composites with various topological configurations.

97 MATHEMATICS AND COMPUTING↗

Advanced-Research-on-Integrated-Energy-Systems-Based Analysis to Support Resilient System Upgrades: Energy to Communities Energyshed In-Depth Partnership with Molokai, Hawaii

The Molokai, Hawaii, Energy to Communities (E2C) Energyshed project represents a collaborative effort between the National Laboratory of the Rockies, Shake Energy Collaborative, the Molokai Clean Energy Hui, Sustainable Molokai, and Ho'ahu Energy Cooperative Molokai to advance Molokai's Community Energy Resilience Action Plan (CERAP). Supported by Hawaiian Electric Company and the Hawaii State Energy Office, the initiative aims to develop a community-defined portfolio of renewable energy solutions that enhance energy resilience while aligning with the Hawaiian Electric Integrated Grid Plan (IGP) and Molokai's energy goals. Phase 1 focused on technical analyses and community engagement to co-design feasible energy scenarios. Challenges such as grid upgrades, storage sizing, and inverter ride-through standards were addressed to align technical and operational requirements with community preferences. The project equips Molokai with actionable data and insights to implement energy initiatives while ensuring resilient and culturally informed solutions. Future efforts aim to finalize project designs, secure interconnection agreements, and deploy energy projects that reflect community priorities and technical feasibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Problem size, parallel architecture and optimal speedup

The communication and synchronization overhead inherent in parallel processing can lead to situations where adding processors to the solution method actually increases execution time. Problem type, problem size, and architecture type all affect the optimal number of processors to employ. The numerical solution of an elliptic partial differential equation is examined in order to study the relationship between problem size and architecture. The equation's domain is discretized into n sup 2 grid points which are divided into partitions and mapped onto the individual processor memories. The relationships between grid size, stencil type, partitioning strategy, processor execution time, and communication network type are analytically quantified. In so doing, the optimal number of processors was determined to assign to the solution, and identified (1) the smallest grid size which fully benefits from using all available processors, (2) the leverage on performance given by increasing processor speed or communication network speed, and (3) the suitability of various architectures for large numerical problems.

Nicol, David M.↗

Problem size, parallel architecture, and optimal speedup

The communication and synchronization overhead inherent in parallel processing can lead to situations where adding processors to the solution method actually increases execution time. Problem type, problem size, and architecture type all affect the optimal number of processors to employ. The numerical solution of an elliptic partial differential equation is examined in order to study the relationship between problem size and architecture. The equation's domain is discretized into n sup 2 grid points which are divided into partitions and mapped onto the individual processor memories. The relationships between grid size, stencil type, partitioning strategy, processor execution time, and communication network type are analytically quantified. In so doing, the optimal number of processors was determined to assign to the solution, and identified (1) the smallest grid size which fully benefits from using all available processors, (2) the leverage on performance given by increasing processor speed or communication network speed, and (3) the suitability of various architectures for large numerical problems.

Nicol, David M.↗