Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Overview of Experimental Investigations for Ares I Launch Vehicle Development

Another concern for the vehicle during its design trajectory was the separation of the first stage solid rocket booster from the upper stage component after it had depleted its solid fuel propellant. There has been some concern about the interstage of the first stage from clearing the nozzle of the J2-X engine. A detailed separation aerodynamic wind tunnel investigation was conducted in the AEDC VKF Tunnel A to help to investigate the interaction aerodynamic effects5. A comparison of the separation plane details between the Ares I architecture and the Ares I-X demonstration flight architecture is shown in figure 12. The Ares I design requires a more complex separation sequence and requires better control in order to avoid contact with the nozzle of the upper stage engine. The interstage, which houses the J2-X engine for the Ares I vehicle, must be able to separate cleanly to avoid contact of the J2-X engine. There is only about approximately 18 inches of buffer inside the interstage on each size of the nozzle so this is a challenging controlled separation event. This complex experimental investigation required two separate Ares I models (upper stage and first stage with interstage attached) with independent strain gauge balances installed in each model. It also required the Captive Trajectory System (CTS) that was needed to precisely locate the components in space relative to each other to fill out the planned test matrix. The model setup in the AEDC VKF Tunnel A is shown in figure 13. The CTS remotely positioned the first stage at the required x, y, and z positions and was able to provide interactions within 0.2" of the upper stage. A sample of the axial force on the first stage booster is shown in figure 14. These results, as a function of separation distance between the two stages, are compared to pre-test CFD results. Since this is a very challenging, highly unsteady flow field for CFD to correctly model, the experimental results have been utilized by GN&C discipline to more accurately represent the interaction aerodynamics. In addition to the integrated forces and moments obtained from the test, flow visualization data was obtained from this test in the form of Schlieren photographs, as shown in figure 15, which show the shock structure and interaction effects after the two stages separate during flight. This separation test was crucial in the successful flight test of the Ares I-X vehicle and provided the GN&C discipline with the unpowered proximity aerodynamic effect for a separation of the Ares I vehicle.

Tomek, William G.↗

Mineral assemblage transformation of a metakaolin-based waste form after geopolymer encapsulation

Current plans for nuclear waste vitrification at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) lack the capacity to treat all of the low activity waste (LAW) that is not encapsulated in the vitrified product. Fluidized Bed Steam Reforming (FBSR) is one of the supplemental technologies under consideration to fill this gap. The FBSR process results in a granular product mainly composed of feldspathoid mineral phases that encapsulate the LAW and other contaminants of concern (COCs). In order to better understand the characteristics of the FBSR product, characterization testing has been performed on the granular product as well as the granular product encapsulated in a monolithic geopolymer binder. The non-radioactive simulated tank waste samples created for use in this study are the result of a 2008 Department of Energy sponsored Engineering Scale Technology Demonstration (ESTD) in 2008. These samples were created from waste simulant that was chemically shimmed to resemble actual tank waste, and rhenium has been used as a substitute for technetium. Another set of samples was created by the Savannah River Site Bench-Scale Reformer (BSR) using a chemical shim of Savannah River Site Tank 50 waste in order to simulate a blend of 68 Hanford tank wastes. This paper presents results from coal and moisture removal tests along with XRD, SEM, and BET analyses showing that the major mineral components are predominantly sodium aluminosilicate minerals and that the mineral product is highly porous. Results also show that the materials pass the short-term leach tests: the Toxicity Characteristic Leaching Procedure (TCLP) and Product Consistency Test (PCT).

Feldspathoid Minerals↗

NASA Ames's electric arc-driven shock tube facility and research on nonequilibrium phenomena in low density hypersonic flows

Basic requirements for a ground test facility simulating low density hypersonic flows are discussed. Such facilities should be able to produce shock velocities in the range of 10-17 km/sec in an initial pressure of 0.010 to 0.050 Torr. The facility should be equipped with diagnostics systems to be able to measure the emitted radiation, characteristic temperatures and populations in various energy levels. In the light of these requirements, NASA Ames's electric arc-driven low density shock tube facility is described and available experimental diagnostics systems and computational tools are discussed.

Sharma, Surendra P.↗

Computational Analysis of Cryogenic Flow Through a Control Valve

The initial efforts to develop the capability to model valves used in rocket engine component testing at Stennis Space Center are documented. An axisymmetric model of a control valve with LN2 as the working fluid was developed. The goal was to predict the effect of change in the plug/sear region of the valve prior to testing. The valve flow coefficient was predicted for a range of plug positions. Verification of the calculations was carried out to quantify the uncertainty in the numerical answer. The modeled results compared well qualitatively to experimental trends. Additionally, insights into the flow processes in the valve were obtained. Benefits from the verification process included the ability to use coarser grids and insight into ways to reduce computational time by using double precision accuracy and non-integer grid ratios. Future valve modeling activities will include shape optimization of the valve/seat region and dynamic grid modeling.

Danes, Russell↗

Inlet Performance of the NFAC 1/50th-scale 80- by 120- Foot Wind Tunnel

The National Full-Scale Aerodynamics Complex 80- by 120-Foot Wind Tunnel (80x120) was dedicated in 1987 and rated at 100 knots for full-scale aircraft testing at NASA Ames Research Center. The 80x120 is the world’s largest wind tunnel, designed as an open circuit tunnel with a large aerodynamically treated inlet open to the ambient atmospheric air. In 2017, damage was sustained within the wind tunnel drive system, opening a window to do testing using the existing 1/50th-scale model of the 80- by 120-Foot Wind Tunnel within the full-scale 80- by 120-Foot Wind tunnel test section. The objective of the research was to quantify the turbulence levels within the 1/50th-scale test section as a function of onset atmospheric wind direction (± 90 deg from tunnel center-line), variable test section speed (5 – 50 m/s) and purposeful obtrusion of wind flow into the inlet. The model wind tunnel inlet, contraction, and test section are geometrically identical to that of the full-scale wind tunnel and model testing provides aerodynamic performance characteristics under controlled test conditions allowing for insight into the full-scale test section flow quality. The test section turbulence levels are minimally affected by the onset direction of the ambient atmospheric wind, but are dramatically affected by the speed in the tunnel while operated in the presence of winds. Original design specifications were axial/vertical/lateral turbulence ≤ 0.5% at maximum test section speed, though early full scale tunnel testing determined that lateral turbulence would be ≤ 0.6%. For test section speeds ≥ 30 m/s the tunnel is within the design specification limits. Between 5 m/s and 30 m/s, the test section turbulence levels are dependent on the onset wind direction and test section speed where test section turbulence in the axial, vertical and lateral directions was seen to be between 0.5% and 1% and, at times, greater than 1%. Finally, testing was performed with blockage designs at the inlet to disrupt the wind flow quality entering the tunnel contraction zone in an attempt to create higher levels of turbulence for high turbulent test conditions simulating the earth’s boundary layer. The highest turbulence levels measured were 6% in the axial direction by use of large spires designed to obstruct ≈ 50% of the inlet area.

Inlet Performance↗

Flow Visualization to Complement Modern Wing Tunnel Testing

In recent times, wind tunnel testing at the NASA Ames Unitary Plan Wind Tunnel (UPWT) seeks to validate computational fluid dynamics (CFD) tools. To that end, we find that now more than ever, flow visualization is a powerful capability that provides context to the experimental results bringing real-time insight to the researcher. It enables us to answer questions like: “Why does this drag polar look different?” or “What is the source of this tone in the microphone data?”. Flow visualization can verify that assumptions made in the CFD model are correct, addressing questions like: “Are our trip dots the correct size and location?” or “Does the position of this shock match our prediction?”. Techniques such as infrared flow visualization and schlieren / shadowgraph are powerful capabilities that when taken together can provide results as to the nature of the fluid structure interaction at a test condition in a format that pairs well with computational results. When properly integrated these measurements can be taken with no impact on the productivity of the test program, supplementing traditional measurements and often discovering something unforeseen, helping the researcher to answer those slippery aerodynamic questions and ultimately build confidence in the accuracy of a model.

wind tunnel↗

Residual interference and wind tunnel wall adaption

Measured flow variables near the test section boundaries, used to guide adjustments of the walls in adaptive wind tunnels, can also be used to quantify the residual interference. Because of a finite number of wall control devices (jacks, plenum compartments), the finite test section length, and the approximation character of adaptation algorithms, the unconfined flow conditions are not expected to be precisely attained even in the fully adapted stage. The procedures for the evaluation of residual wall interference are essentially the same as those used for assessing the correction in conventional, non-adaptive wind tunnels. Depending upon the number of flow variables utilized, one can speak of one- or two-variable methods; in two dimensions also of Schwarz- or Cauchy-type methods. The one-variable methods use the measured static pressure and normal velocity at the test section boundary, but do not require any model representation. This is clearly of an advantage for adaptive wall test section, which are often relatively small with respect to the test model, and for the variety of complex flows commonly encountered in wind tunnel testing. For test sections with flexible walls the normal component of velocity is given by the shape of the wall, adjusted for the displacement effect of its boundary layer. For ventilated test section walls it has to be measured by the Calspan pipes, laser Doppler velocimetry, or other appropriate techniques. The interface discontinuity method, also described, is a genuine residual interference assessment technique. It is specific to adaptive wall wind tunnels, where the computation results for the fictitious flow in the exterior of the test section are provided.

Mokry, Miroslav↗

Parameter identification applied to analytic hingeless rotor modeling

It is known that dynamic rotor inflow has a substantial effect on rotor dynamic loads. Despite the complexity of the unsteady flow problem, simple analytical models can be made useful by identifying their parameters from transient response tests without performing flow measurements. Two analytical inflow models are studied: the first is based on an equivalent blade Lock number, the second is based on a time delayed unsteady momentum inflow. In preparation for the experimental data analysis, identifications from simulated test data and an eigenvalue analysis are performed. The experimental results show that the first analytical inflow model is accurate for rotor advance ratios of 0.4 and above. For lower advance ratios, the second inflow model provides better accuracy. Prediction studies with experimental data not used for the identification are performed to determine the accuracy of the mathematical models.

Banerjee, D.↗

Small Gas Bubble Experiment for Mitigation of Cavitation Damage and Pressure Waves in Short-pulse Mercury Spallation Targets

Populations of small helium gas bubbles were introduced into a flowing mercury experiment test loop to evaluate mitigation of beam-pulse induced cavitation damage and pressure waves. The test loop was developed and thoroughly tested at the Spallation Neutron Source (SNS) prior to irradiations at the Los Alamos Neutron Science Center - Weapons Neutron Research Center (LANSCE-WNR) facility. Twelve candidate bubblers were evaluated over a range of mercury flow and gas injection rates by use of a novel optical measurement technique that accurately assessed the generated bubble size distributions. Final selection for irradiation testing included two variations of a swirl bubbler provided by Japan Proton Accelerator Research Complex (J-PARC) collaborators and one orifice bubbler developed at SNS. Bubble populations of interest consisted of sizes up to 150 m in radius with achieved gas void fractions in the 10^-5 to 10^-4 range. The nominal WNR beam pulse used for the experiment created energy deposition in the mercury comparable to SNS pulses operating at 2.5 MW. Nineteen test conditions were completed each with 100 pulses, including variations on mercury flow, gas injection and protons per pulse. The principal measure of cavitation damage mitigation was surface damage assessment on test specimens that were manually replaced for each test condition. Damage assessment was done after radiation decay and decontamination by optical and laser profiling microscopy with damaged area fraction and maximum pit depth being the more valued results. Damage was reduced by flow alone; the best mitigation from bubble injection was between half and a quarter that of flow alone. Other data collected included surface motion tracking by three laser Doppler vibrometers (LDV), loop wall dynamic strain, beam diagnostics for charge and beam profile assessment, embedded hydrophones and pressure sensors, and sound measurement by a suite of conventional and contact microphones.

bubbles↗

Numerical study to assess sulfur hexafluoride as a medium for testing multielement airfoils

A methodology is described for computing viscous flows of air and sulfur hexafluoride (SF6). The basis is an existing flow solver that calculates turbulent flows in two dimensions on unstructured triangular meshes. The solver has been modified to incorporate the thermodynamic model for SF6 and used to calculate the viscous flow over two multielement airfoils that have been tested in a wind tunnel with air as the test medium. Flows of both air and SF6 at a free-stream Mach number of 0.2 and a Reynolds number of 9 x 10(exp 6) are computed for a range of angles of attack corresponding to the wind-tunnel test. The computations are used to investigate the suitability of SF6 as a test medium in wind tunnels and are a follow-on to previous computations for single-element airfoils. Surface-pressure, lift, and drag coefficients are compared with experimental data. The effects of heavy gas on the details of the flow are investigated based on computed boundary-layer and skin-friction data. In general, the predictions in SF6 vary little from those in air. Within the limitations of the computational method, the results presented are sufficiently encouraging to warrant further experiments.

Bonhaus, Daryl L.↗

Material permeance measurement system and method

A system for measuring the permeance of a material. The permeability of the material may also be derived. The system provides a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

36 MATERIALS SCIENCE↗

System and method for measuring permeability of materials

Systems and methods are provided for measuring the permeance of a material. The permeability of the material may also be derived. Systems typically provide a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

36 MATERIALS SCIENCE↗

Hydrodynamic and Aerodynamic Tests of Models of Flying-boat Hulls Designed Flow Aerodynamic Drag - NACA Models 74, 74-A, and 75

The present tests illustrate how the aerodynamic drag of a flying boat hull may be reduced by following closely the form of a low drag aerodynamic body and the manner in which the extent of the aerodynamic refinement is limited by poorer hydrodynamic performance. This limit is not sharply defined but is first evidenced by an abnormal flow of water over certain parts of the form accompanied by a sharp increase in resistance. In the case of models 74-A and 75, the resistance (sticking) occurs only at certain combinations of speed, load, and trim and can be avoided by proper control of the trim at high water speeds. Model 75 has higher water resistance at very high speeds than does model 74-A. With constant speed propellers and high takeoff speeds, it appears that the form of model 75 would give slightly better takeoff performance. Model 74-A, however, has lower aerodynamic drag than does model 75 for the same volume of hull.

Truscott, Starr↗

Cold-flow acoustic evaluation of a small scale, divergent, lobed nozzle for supersonic jet noise suppression

A supersonic jet noise suppressor was tested with cold flow for acoustic and thrust characteristics at nozzle- to atmospheric-pressure ratios of 1.5 to 4.0. Jet noise suppression and spectral characteristics of the divergent, lobed, suppressor (DLS) nozzle with and without an ejector are presented. Suppression was obtained at nozzle pressure ratios of 2.5 to 4.0. The largest, maximum-lobe, sound pressure level suppression with a hard-wall ejector was 14.6 decibels at a nozzle pressure ratio of 3.5. The thrust loss was 2 percent. In general, low-frequency jet noise was suppressed, leaving higher frequencies essentially unchanged. Without the ejector the nozzle showed a thrust loss of 11 percent together with slightly poorer noise suppression.

Huff, R. G.↗

Natural laminar flow flight experiments on a swept wing business jet-boundary layer stability analyses

The linear boundary layer stability analyses and their correlation with data of 18 cases from a natural laminar flow (NLF) flight test program using a Cessna Citation 3 business jet are described. The transition point varied from 5% to 35% chord for these conditions, and both upper and lower wing surfaces were included. Altitude varied from 10,000 to 43,000 ft and Mach number from 0.3 to 0.8. Four cases were at nonzero sideslip. Although there was much scatter in the results, the analyses of boundary layer stability at the 18 conditions led to the conclusion that crossflow instability was the primary cause of transition. However, the sideslip cases did show some interaction of crossflow and Tollmien-Schlichting disturbances. The lower surface showed much lower Tollmien-Schlichting amplification at transition than the upper surface, but similar crossflow amplifications. No relationship between Mach number and disturbance amplification at transition could be found. The quality of these results is open to question from questionable wing surface quality, inadequate density of transition sensors on the wing upper surface, and an unresolved pressure shift in the wing pressure data. The results of this study show the need for careful preparation for transition experiments. Preparation should include flow analyses of the test surface, boundary layer disturbance amplification analyses, and assurance of adequate surface quality in the test area. The placement of necessary instruments and usefulness of the resulting data could largely be determined during the pretest phase.

Rozendaal, R. A.↗

Experimental investigations on sodium plugging in narrow flow channels.

A series of experiments was performed to investigate the potential for plugging of narrow flow channels of sodium by impurities (e.g., oxides). In the first phase of the experiments, clean sodium was circulated through the test sections simulating flow channels in a compact diffusion-bonded heat exchanger such as a printed circuit heat exchanger. The primary objective was to see if small channels whose cross sections are semicircles of 2, 4, and 6 mm in diameter are usable in liquid sodium applications where sodium purity is carefully controlled. It was concluded that the 2-mm channels, the smallest of the three, could be used in clean sodium systems at temperatures even as low as 100 to 110 C without plugging. In the second phase, sodium oxide was added to the loop, and the oxygen concentration in the liquid sodium was controlled by means of varying the cold-trap temperature. Intentional plugging was induced by creating a cold spot in the test sections, and the subsequent plugging behavior was observed. It was found that plugging in the 2-mm test section was initiated by lowering the cold spot temperature below the cold-trap temperature by 10 to 30 C. Unplugging of the plugged channels was accomplished by heating the affected test section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhancing high-fidelity nonlinear solver with reduced order model

Abstract We propose the use of reduced order modeling (ROM) to reduce the computational cost and improve the convergence rate of nonlinear solvers of full order models (FOM) for solving partial differential equations. In this study, a novel ROM-assisted approach is developed to improve the computational efficiency of FOM nonlinear solvers by using ROM’s prediction as an initial guess. We hypothesize that the nonlinear solver will take fewer steps to the converged solutions with an initial guess that is closer to the real solutions. To evaluate our approach, four physical problems with varying degrees of nonlinearity in flow and mechanics have been tested: Richards’ equation of water flow in heterogeneous porous media, a contact problem in a hyperelastic material, two-phase flow in layered porous media, and fracture propagation in a homogeneous material. Overall, our approach maintains the FOM’s accuracy while speeding up nonlinear solver by 18–73% (through suitable ROM-assisted FOMs). More importantly, the proximity of ROM’s prediction to the solution space leads to the improved convergence of FOMs that would have otherwise diverged with default initial guesses. We demonstrate that the ROM’s accuracy can impact the computational efficiency with more accurate ROM solutions, resulting in a better cost reduction. We also illustrate that this approach could be used in many FOM discretizations (e.g., finite volume, finite element, or a combination of those). Since our ROMs are data-driven and non-intrusive, the proposed procedure can easily lend itself to any nonlinear physics-based problem.

97 MATHEMATICS AND COMPUTING↗