Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Critical fields of Nb 3 Sn prepared for superconducting cavities

Abstract Nb 3 Sn is currently the most promising material other than niobium for future superconducting radiofrequency cavities. Critical fields above 120 mT in pulsed operation and about 80 mT in CW have been achieved in cavity tests. This is large compared to the lower critical field as derived from the London penetration depth, extracted from low field surface impedance measurements. In this paper direct measurements of the London penetration depth from which the lower critical field and the superheating field are derived are presented. The field of first vortex penetration is measured under DC and RF fields. The combined results confirm that Nb 3 Sn cavities are indeed operated in a metastable state above the lower critical field but are currently limited to a critical field well below the superheating field.

43 PARTICLE ACCELERATORS↗

Ta, Ti and Hf effects on Nb 3 Sn high-field performance: temperature-dependent dopant occupancy and failure of Kramer extrapolation

The increasing demand for improving the high-field (16-22 T) performance of Nb 3 Sn conductors requires a better understanding of the properties of modern wires much closer to irreversibility field, H Irr . In this study we investigated the impact of Ta, Ti and Hf doping on the high-field pinning properties, the upper critical field, H c2 , and H Irr . We found that the pinning force curves of commercial Ti and Ta doped wires at different temperatures do not scale and that the Kramer extrapolation, typically used by magnet designers to estimate high-field critical current density and magnet operational margins from lower field data, is not reliable and significantly overestimates the actual H Irr . In contrast, new laboratory scale conductors made with Nb-Ta-Hf alloy have improved high-field J c performance and, despite contributions by both grain boundary and point defect pinning mechanisms, have more predictable high-field behavior. Using Extended X-ray Absorption Fine Structure spectroscopy, EXAFS, we found that for the commercial Ta and Ti doped conductors, the Ta site occupancy in the A15 structure gradually changes with the heat treatment temperature whereas Ti is always located on the Nb site with clear consequences for H c2 . Finally, this work reveals the still limited understanding of what determines H c2 , H Irr and the high-field J c performance of Nb 3 Sn and the complexity of optimizing these conductors so that they can reach their full potential for high-field applications.

36 MATERIALS SCIENCE↗

The primordial curvature perturbation from vector fields of general non-Abelian groups

We consider the generation of primordial curvature perturbation by general non-Abelian vector fields without committing to a particular group. Self-interactions of non-Abelian fields make the field perturbation non-Gaussian. We calculate the bispectrum of the field perturbation using the in-in formalism at tree level. The bispectrum is dominated by the classical evolution of fields outside the horizon. In view of this we show that the dominant contribution can be obtained from the homogeneous classical equation of motion. Then we calculate the power spectrum of the curvature perturbation. The anisotropy in spectrum is suppressed by the number of fields. This makes it possible for vector fields to be responsible for the total curvature perturbation in the Universe without violating observational bounds on statistical anisotropy. The bispectrum of the curvature perturbation is also anisotropic. Finally we give an example of the end-of-inflation scenario in which the curvature perturbation is generated by vector gauge fields through varying gauge coupling constant(s), which in covariant derivatives couples the Higgs field to the vector fields. We find that reasonably large gauge groups may result in the observable anisotropy in the power spectrum of the curvature perturbation.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining primordial magnetic fields with future cosmic shear surveys

The origin of astrophysical magnetic fields observed in galaxies and clusters of galaxies is still unclear. One possibility is that primordial magnetic fields generated in the early Universe provide seeds that grow through compression and turbulence during structure formation. A cosmological magnetic field present prior to recombination would produce substantial matter clustering at intermediate/small scales, on top of the standard inflationary power spectrum. In this work we study the effect of this alteration on one particular cosmological observable, cosmic shear. We adopt the semi-analytic halo model in order to describe the non-linear clustering of matter, and feed it with the altered mass variance induced by primordial magnetic fields. We find that the convergence power spectrum is, as expected, substantially enhanced at intermediate/small angular scales, with the exact amplitude of the enhancement depending on the magnitude and power-law index of the magnetic field power spectrum. Specifically, for a fixed amplitude, the effect of magnetic fields is larger for larger spectral indices. We use the predicted statistical errors for a future wide-field cosmic shear survey, on the model of the ESA Cosmic Vision mission Euclid, in order to forecast constraints on the amplitude of primordial magnetic fields as a function of the spectral index. We find that the amplitude will be constrained at the level of ∼ 0.1 nG for n{sub B} ∼ −3, and at the level of ∼ 10{sup −7} nG for n{sub B} ∼ 3. The latter is at the same level of lower bounds coming from the secondary emission of gamma-ray sources, implying that for high spectral indices Euclid will certainly be able to detect primordial magnetic fields, if they exist. The present study shows how large-scale structure surveys can be used for both understanding the origins of astrophysical magnetic fields and shedding new light on the physics of the pre-recombination Universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Diffusion of cosmic rays at EeV energies in inhomogeneous extragalactic magnetic fields

Ultra-high energy cosmic rays can propagate diffusively in cosmic magnetic fields. When their propagation time is comparable to the age of the universe, a suppression in the flux relative to the case in the absence of magnetic fields will occur. In this work we find an approximate parametrization for this suppression for energies below ∼ Z EeV using several magnetic field distributions obtained from cosmological simulations of the magnetized cosmic web. We assume that the magnetic fields have a Kolmogorov power spectrum with the field strengths distributed according to these simulations. We show that, if magnetic fields are coupled to the matter distribution, low field strengths will fill most of the volume, making the suppression milder compared to the case of a constant magnetic field with strength equal to the mean value of this distribution. We also derive upper limits for this suppression to occur for some models of extragalactic magnetic fields, as a function of the coherence length of these fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Inflation with an extra light scalar field after Planck

Bayesian inference techniques are used to investigate situations where an additional light scalar field is present during inflation and reheating. This includes (but is not limited to) curvaton-type models. We design a numerical pipeline where ≅ 200 inflaton setups × 10 reheating scenarios = 2000 models are implemented and we present the results for a few prototypical potentials. We find that single-field models are remarkably robust under the introduction of light scalar degrees of freedom. Models that are ruled out at the single-field level are not improved in general, because good values of the spectral index and the tensor-to-scalar ratio can only be obtained for very fine-tuned values of the extra field parameters and/or when large non-Gaussianities are produced. The only exception is quartic large-field inflation, so that the best models after Planck are of two kinds: plateau potentials, regardless of whether an extra field is added or not, and quartic large-field inflation with an extra light scalar field, in some specific reheating scenarios. Using Bayesian complexity, we also find that more parameters are constrained for the models we study than for their single-field versions. This is because the added parameters not only contribute to the reheating kinematics but also to the cosmological perturbations themselves, to which the added field contributes. The interplay between these two effects lead to a suppression of degeneracies that is responsible for having more constrained parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Mapping the magnetic field in the Taurus/B211 filamentary cloud with SOFIA HAWC + and comparing with simulation

ABSTRACT Optical and infrared polarization mapping and recent Planck observations of the filametary cloud L1495 in Taurus show that the large-scale magnetic field is approximately perpendicular to the long axis of the cloud. We use the HAWC + polarimeter on SOFIA to probe the complex magnetic field in the B211 part of the cloud. Our results reveal a dispersion of polarization angles of 36°, about five times that measured on a larger scale by Planck. Applying the Davis–Chandrasekhar–Fermi (DCF) method with velocity information obtained from Institut de Radioastronomie Millimétrique 30 m C18O(1-0) observations, we find two distinct sub-regions with magnetic field strengths differing by more than a factor 3. The quieter sub-region is magnetically critical and sub-Alfv$\acute{\rm e}$nic; the field is comparable to the average field measured in molecular clumps based on Zeeman observations. The more chaotic, super-Alfv$\acute{\rm e}$nic sub-region shows at least three velocity components, indicating interaction among multiple substructures. Its field is much less than the average Zeeman field in molecular clumps, suggesting that the DCF value of the field there may be an underestimate. Numerical simulation of filamentary cloud formation shows that filamentary substructures can strongly perturb the magnetic field. DCF and true field values in the simulation are compared. Pre-stellar cores are observed in B211 and are seen in our simulation. The appendices give a derivation of the standard DCF method that allows for a dispersion in polarization angles that is not small, present an alternate derivation of the structure function version of the DCF method, and treat fragmentation of filaments.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-energy magneto-optics of Tb 2 Ti 2 O 7 in a [111] magnetic field

The pyrochlore magnet Tb 2 Ti 2 O 7 shows a lack of magnetic order to low temperatures and is considered to be a quantum spin liquid candidate. Here we perform time-domain THz spectroscopy on high-quality Tb 2 Ti 2 O 7 crystals and study the low-energy excitations as a function of [111] magnetic field with high energy resolution. The low-energy crystal-field excitations change their energies anomalously under magnetic field. Despite several sharp field-dependent changes, we show that the material's spectrum can be described not by phase transitions but by field-dependent hybridization between the low-energy crystal-field levels. We highlight the strong coupling between spin and lattice degrees of freedom in Tb 2 Ti 2 O 7 as evidenced by the magnetic-field tunable crystal-field environment. Calculations based on single ion physics with field-induced symmetry reduction of the crystal-field environment can reproduce our data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation of the effect of local atomic polarization on field-enhanced ion transport in insulating binary oxides: The case of CeO 2

Over the course of more than 70 years, several theoretical models for electric field-enhanced ion diffusion in crystalline insulators have been presented. However, there is no assessment of the validity of these models despite the urge to have a correct description of field-enhanced ion diffusion in several emerging technologies. Herein, an assessment of five models was carried out by computing the field-dependent migration enthalpy ΔH mig (E) for the oxide ion in CeO 2 . The input to these models is the zero-field and zero-temperature migration pathway and/or the activation barrier obtained from an interatomic potential. ΔH mig (E) from these models was compared with reference values obtained from a set of classical molecular-dynamics simulations in the temperature range of 1000 ≤ T ≤ 1600 K and the electric field range of 0 ≤ E ≤ 30 MV/cm. It is revealed that the most successful theoretical models are those that consider local polarization effects induced in the diffusing ion itself and its vicinity. However, all the models did not account for the effect of the electric field and finite temperature on the local polarization, leading to discrepancies between the predicted and the reference ΔH mig (E), particularly at high fields. By comparing results from a rigid-ion potential and a polarizable core-shell potential, it is concluded that an intraionic polarization degree of freedom in the polarizable potential is an important factor in predicting ΔH mig (E), regardless of the field-enhanced diffusion model particularly for low to moderate field. Finally, future more accurate treatments should consider the field- and temperature-dependent interionic and intraionic local polarization effects.

36 MATERIALS SCIENCE↗

Artificial Soiling Replication of Field Losses on Commercial Photovoltaic Modules

Here, this study demonstrates the capabilities of an indoor artificial soiling approach developed to closely replicate the natural, cyclic soil accumulation processes in the field-dust suspension, deposition, and sedimentation/cementation-for a subtropical climate. In this work, a near-field environment is replicated in an artificial soiling cubic chamber through controlled regulation of humidity, temperature, dust type, and dust concentration, based on site-specific historical climate data. Two different models (MA and MB) of full-size commercial photovoltaic modules from a single manufacturer, installed side by side in the mid-Atlantic United States, were retrieved and subjected to artificial soiling experiments and various characterization measurements, including short-circuit current, colorimetry, reflectance, X-ray fluorescence, laser diffraction, and optical microscopy. Both in the field and in our improved field-representative artificial soiling tests, the MA model experienced roughly twice the soiling loss as the MB model. To closely replicate the field soiling losses for a site-specific climate, it is critical to include: 1) The use of field-collected dust with identical dust chemistry and particle distribution instead of standardized ISO 12103 Arizona Road dusts, 2) the use of only a small amount of field-collected dust inside the chamber during the deposition process (e.g., 0.15 g), and 3) the preconditioning of the surface coating for the partial/full dose of UV stress as experienced in the field during sunlight exposure and the abrasion as experienced in the field during regular module cleaning activities, if/as needed. The field-representative artificial soiling method developed here could potentially be adopted for rank ordering of various antisoiling coatings developed by researchers and industry stakeholders.

14 SOLAR ENERGY↗

Impact of static magnetic fields on the radial line slot antenna plasma source

The radial line slot antenna plasma source is used in semiconductor device fabrication. As is the case for all plasma sources, ever more strict uniformity control requirements are driven by the precision demands of new device technologies. Large volume diffusion plasmas, of which the radial line slot antenna source is one type, must overcome transport effects or diffusion modes that tend to 'center peak' the plasma density near the wafer being processed. One way to resolve problematic transport effects is the insertion of magnetic fields into the plasma region. In this paper, the impact of the magnetic field on plasma properties is parameterized as a function of slot configuration. The magnetic field orientation and the magnitude of magnetic field are varied in a computational study in which the source is modeled as a two-dimensional axisymmetric quasineutral plasma. This work employs a finite element model simulation. The magnitude of magnetic fields considered is 50 Gauss maximum with a microwave power of 3000 W at a pressure of 20 mTorr. 20 mTorr is chosen as this is a condition where diffusion effects are challenging to counteract. The study showed that there are specific conditions for slot configuration and magnetic field that improve the plasma controllability and some that do not. Plasma property modulation is most effective when the plasma source region is placed at large radius with axial magnetic fields. There are synergistic effects between the slot location and magnetic field that are important and placing large magnetic fields at the chamber edge alone does not result in improved uniformity. Electron cyclotron resonance (ECR) heating and the impact of pulsing the magnetic fields are presented. ECR heating is not important for the conditions relevant to this paper and pulsing is shown to have benefit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lung dosimetry in a linac-MRI radiotherapy unit with a longitudinal magnetic field

Purpose: There is interest in developing linac-MR systems for MRI-guided radiation therapy. To date, the designs for such linac-MR devices have been restricted to a transverse geometry where the static magnetic field is oriented perpendicular to the direction of the incident photon beam. This work extends possibilities in this field by proposing and examining by Monte Carlo simulations, a probable longitudinal configuration where the magnetic field is oriented in the same direction as the photon beam. Methods: The EGSnrc Monte Carlo (MC) radiation transport codes with algorithms implemented to account for the magnetic field deflection of charged particles were used to compare dose distributions for linac-MR systems in transverse and longitudinal geometries. Specifically, the responses to a 6 MV pencil photon beam incident on water and lung slabs were investigated for 1.5 and 3.0 T magnetic fields. Further a five field lung plan was simulated in the longitudinal and transverse geometries across a range of magnetic field strengths from 0.2 through 3.0 T. Results: In a longitudinal geometry, the magnetic field is shown to restrict the radial spread of secondary electrons to a small degree in water, but significantly in low density tissues such as lung in contrast to the lateral shift in dose distribution seen in the transverse geometry. These effects extend to the patient case, where the longitudinal configuration demonstrated dose distributions more tightly confined to the primary photon fields, which increased dose to the planning target volume (PTV), bettered dose homogeneity within a heterogeneous (in density) PTV, and reduced the tissue interface effects associated with the transverse geometry. Conclusions: Dosimetry issues observed in a transverse linac-MR geometry such as changes to the depth dose distribution and tissue interface effects were significantly reduced or eliminated in a longitudinal geometry on a representative lung plan. Further, an increase in dose to the PTV, resulting from the magnetic field confining electrons to the forward direction, shows potential for a reduction in dose to the surrounding tissues.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-233: A Facility for Radiobiological Experiments in a Large Magnetic Field

Purpose: There is considerable interest in developing medical linear accelerators with integrated image guidance by MRI. Less work has been done on the fundamental biology of cell survival in the presence of a strong magnetic field. The purpose of this work is to describe an experimental system capable of measuring cell survival response in the types of MRI-linac systems currently under development. Methods: We have integrated a cobalt irradiator with a solenoid magnet. The solenoid magnet has inner diameter of 10 cm. To enable measurement of the biological effects as a function of depth, we are utilizing the sliced gel technique, in which cells are embedded and fixed within a gelatin matrix. Irradiated cells at defined positions (sub mm resolution) can subsequently be recovered and assessed for cell survival or other biological effects. Results: The magnetic field profile in the solenoid has a peak magnetic field 36 cm below the top edge of the magnet bore and can be placed at and SAD of 100 cm. At a solenoid current of 35 A, the peak magnetic field is 0.25 T. The dose rate of the cobalt irradiator is 16 cGy/min at 100 cm SAD. EBT3 film was used to demonstrate the system functionality. It was irradiated at 1 cm depth at 100 cm SSD with a 4×4 field to 1.5 Gy in a 0.25 T magnetic field. The dose profile was similar between this film and the control exposure without magnetic field. Conclusion: Integrating a cobalt irradiator with a high field magnet is demonstrated. The magnetic field at the cobalt defining head was minimal and did not interfere with the functioning of this unit. Cell survival experiments can be reproduced exactly in the presence or absence of a magnetic field since a resistive magnet is used.

60 APPLIED LIFE SCIENCES↗

A deterministic solution of the first order linear Boltzmann transport equation in the presence of external magnetic fields

Purpose: Accurate radiotherapy dose calculation algorithms are essential to any successful radiotherapy program, considering the high level of dose conformity and modulation in many of today’s treatment plans. As technology continues to progress, such as is the case with novel MRI-guided radiotherapy systems, the necessity for dose calculation algorithms to accurately predict delivered dose in increasingly challenging scenarios is vital. To this end, a novel deterministic solution has been developed to the first order linear Boltzmann transport equation which accurately calculates x-ray based radiotherapy doses in the presence of magnetic fields. Methods: The deterministic formalism discussed here with the inclusion of magnetic fields is outlined mathematically using a discrete ordinates angular discretization in an attempt to leverage existing deterministic codes. It is compared against the EGSnrc Monte Carlo code, utilizing the emf-macros addition which calculates the effects of electromagnetic fields. This comparison is performed in an inhomogeneous phantom that was designed to present a challenging calculation for deterministic calculations in 0, 0.6, and 3 T magnetic fields oriented parallel and perpendicular to the radiation beam. The accuracy of the formalism discussed here against Monte Carlo was evaluated with a gamma comparison using a standard 2%/2 mm and a more stringent 1%/1 mm criterion for a standard reference 10 × 10 cm{sup 2} field as well as a smaller 2 × 2 cm{sup 2} field. Results: Greater than 99.8% (94.8%) of all points analyzed passed a 2%/2 mm (1%/1 mm) gamma criterion for all magnetic field strengths and orientations investigated. All dosimetric changes resulting from the inclusion of magnetic fields were accurately calculated using the deterministic formalism. However, despite the algorithm’s high degree of accuracy, it is noticed that this formalism was not unconditionally stable using a discrete ordinate angular discretization. Conclusions: The feasibility of including magnetic field effects in a deterministic solution to the first order linear Boltzmann transport equation is shown. The results show a high degree of accuracy when compared against Monte Carlo calculations in all magnetic field strengths and orientations tested.

60 APPLIED LIFE SCIENCES↗

SU-E-T-227: Could the Alpha/Beta Ratio Change in a Strong Magnetic Field?

Purpose: Magnetic resonance imaging (MRI) is being integrated into radiotherapy delivery for MRI-guided radiotherapy. The presence of a strong magnetic field from a MRI machine during radiotherapy delivery presents a new challenge since the trajectories of electrons liberated by ionizing radiation in patients are strongly dependent on the applied magnetic field. The purpose of this work is to explore the potential effect of a strong magnetic field on the α/β ratio, an important radiobiological parameter in radiotherapy. Methods: Based on the theory of dual radiation action, the α/β ratio can be expressed by an integral of the product of two microdosimetry quantities γ(x) and t(x), where γ(x) is the probability that two energy transfers, a distance x apart, results in a lesion, and t(x) is the proximity function, which is the energy-weighted point-pair distribution of distances between energy transfer points in a track. The quantity t(x) depends on the applied magnetic field. An analytical approach has been used to derive a formula that can be used to calculate the α/β ratio in an extremely strong magnetic field. Results: The α/β ratio has been evaluated in the special case when the applied magnetic field approaches infinity, which gives the upper limit of the potential change of the α/β ratio due to the presence of a strong magnetic field. For V79 Chinese hamster cells it has been shown that the α/β ratio could be increased by 2.90 times for Pd-103, 2.97 times for I-125 and about 2.3 times for Co-60 sources when the applied magnetic field approaches infinity. Conclusion: It has been shown theoretically that the α/β ratio can change in a strong magnetic field, and there could be up to a nearly three-fold increase in the α/β ratio, depending on the strength of the applied magnetic field, the cell type and the radiation used.

60 APPLIED LIFE SCIENCES↗

SU-F-T-324: Experimental Measurement of Optically Stimulated Luminescence Detectors in a MR-IGRT Environment Toward Assessing Magnetic Field Effects On These Devices and Their Use as An In-Vivo Dosimeter

Purpose: To characterize magnetic field effects on Optically Stimulated Luminescence Detectors (OSLDs) for use as an in-vivo dosimeter in an MRIGRT machine. Methods: Landauer OSLD nano-dots and the MicroStar II reader were used to measure and record OSLDs exposed in and on a solid water phantom in a 10.5 × 10.5 cm{sup 2} field, Co-60, 0.32-Tesla MR-IGRT machine - with and without the presence of the magnetic field. Two orthogonal gantry angles were considered to assess orientation effects on the OSLDs with respect to the incident angle of the radiation beam and magnetic field. The same OSLDs were then used (after readout and bleaching) when the magnetic field was restored. Results: The measured surface dose decreased by 14.1 ± 1.8% when magnetic field was ’on’ due to contamination electrons being swept away by the field. Doses at both 0.5 cm and 5 cm depth increased by 6.5 ± 0.9% and 8.8 ± 0.5% respectively when the magnetic field was present and the OSLDs oriented with their long axis parallel with the incident beam. This contrasts with an increased dose of 2.7 ± 1.1% when the magnetic field was present and the OSLDs were oriented with their long axis perpendicular to the incident beam. Conclusion: Previous works have shown that OSLDs have a dependence on beam incidence angle. Our current work suggests an additional dependence on the presence of the magnetic field when the beam is not perpendicular to the plane of the detector and this effect needs to be considered. Furthermore, the use of an in-vivo dosimeter was shown to have no effect on image quality during the use of MR guidance. Future work will focus on the use of an electromagnet with a linear accelerator to further characterize these effects.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-15: Proton Beam Behavior in the Presence of Realistic Magnet Fields

Purpose: To investigate the effects of magnetic fields on proton therapy beams for integration with MRI. Methods: 3D magnetic fields from an open-bore superconducting MRI model (previously developed by our group) and 3D magnetic fields from an in-house gradient coil design were applied to various mono energetic proton pencil beam (80MeV to 250MeV) simulations. In all simulations, the z-axis of the simulation geometry coincided with the direction of the B0 field and magnet isocentre. In each simulation, the initial beam trajectory was varied. The first set of simulations performed was based on analytic magnetic force equations (analytic simulations), which could be rapidly calculated yet were limited to propagating proton beams in vacuum. The second set is full Monte Carlo (MC) simulations, which used GEANT4 MC toolkit. Metrics such as the beam position and dose profiles were extracted. Comparisons between the cases with and without magnetic fields present were made. Results: The analytic simulations served as verification checks for the MC simulations when the same simulation geometries were used. The results of the analytic simulations agreed with the MC simulations performed in vacuum. The presence of the MRI’s static magnetic field causes proton pencil beams to follow a slight helical trajectory when there were some initial off-axis components. The 80MeV, 150MeV, and 250MeV proton beams rotated by 4.9o, 3.6o, and 2.8o, respectively, when they reached z=0cm. The deflections caused by gradient coils’ magnetic fields show spatially invariant patterns with a maximum range of 0.5mm at z=0cm. Conclusion: This investigation reveals that both the MRI’s B0 and gradient magnetic fields can cause small but observable deflections of proton beams at energies studied. The MRI’s static field caused a rotation of the beam while the gradient coils’ fields effects were spatially invariant. Dr. B Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-07: MRI-Linac Dosimetry: Parameters That Change in a Magnetic Field

Purpose: In MRI-linac integrated systems, the presence of the magnetic (B-)field has a large impact of the dose-distribution and the dose-responses of detectors; yet established protocols and previous experience may lead to assumptions about the commissioning process that are no longer valid. This study quantifies parameters that change when performing dosimetry with an MRI-linac including beam quality specifiers and the effective-point-of-measurement (EPOM) of ionization chambers. Methods: We used the Geant4 Monte Carlo code for this work with physics parameters that pass the Fano cavity test to within 0.1% for the simulated conditions with and without a 1.5 T B-field. A point source model with the energy distribution of an MRI-linac beam was used with and without the B-field to calculate the beam quality specifiers %dd(10)× and TPR{sup 20}{sub 10}, the variation of chamber response with orientation and the how the B-field affects the EPOM of ionization chambers by comparing depth-dose curves calculated in water to those generated by a model PTW30013 Farmer chamber. Results: The %dd(10)× changes by over 2% in the presence of the B-field while the TPR{sup 20}{sub 10} is unaffected. Ionization chamber dose-response is known to depend on the orientation w.r.t. the B-field, but two alternative perpendicular orientations (anti-parallel to each other) also differ in dose-response by over 1%. The B-field shifts the EPOM downstream (closer to the chamber center) but it is also shifted laterally by 0.27 times the chamber’s cavity radius. Conclusion: The EPOM is affected by the B-field and it even shifts laterally. The relationship between %dd(10)× and the Spencer-Attix stopping powers is also changed. Care must be taken when using chambers perpendicular to the field as the dose-response changes depending on which perpendicular orientation is used. All of these effects must be considered when performing dosimetry in B-fields and should be accounted for in future dosimetry protocols. This project was partially funded by Elekta Ltd.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗