NASA Puffin Electric Tailsitter VTOL Concept

Electric propulsion offers dramatic new vehicle mission capabilities, not possible with turbine or reciprocating engines; including high reliability and efficiency, low engine weight and maintenance, low cooling drag and volume required, very low noise and vibration, and zero emissions. The only penalizing characteristic of electric propulsion is the current energy storage technology level, which is set to triple over the next 5-10 years through huge new investments in this field. Most importantly, electric propulsion offers incredible new degrees of freedom in aircraft system integration to achieve unprecedented levels of aerodynamic, propulsive, control, and structural synergistic coupling. A unique characteristic of electric propulsion is that the technology is nearly scale-free, permitting small motors to be parallelized for fail-safe redundancy, or distributed across the airframe for tightly coupled interdisciplinary functionality without significant impacts in motor-controller efficiency or specific weight. Maximizing the potential benefit of electric propulsion is dependent on applying this technology to synergistic mission concepts. The vehicle missions with the most benefit include those which constrain environmental impact (or limit noise, exhaust, or emission signatures) are short range, or where large differences exist in the propulsion system sizing between takeoff and cruise conditions. Electric propulsion offers the following unique capabilities that other propulsion systems can t provide for short range Vertical Takeoff and Landing (VTOL) aircraft; elimination of engine noise and emissions, drastic reduction in engine cooling and radiated heat, drastic reduction in vehicle vibration levels, drastic improvement in reliability and operating costs, variable speed output at full power, for improved cruise efficiency at low tip-speed, elimination of high/hot sizing penalty, and reduction of engine-out penalties.

Moore, Mark D.↗

Inrush-Current Limiter And Bus Isolator

Electronic circuit protects electrical power bus and source of power against excessive current demands. Circuit intended for use with power-consuming electronic system drawing pulsed currents and including capacitor bank as low-impedance secondary source from which pulsed currents drawn.

Dolland, Carlisle R.↗

Breakdown characteristics of deep-ultraviolet Al 0.6 Ga 0.4 N p-i-n avalanche photodiodes

A top-illuminated deep-ultraviolet Al 0.6 Ga 0.4 N p-i-n avalanche photodiode (APD) structure was designed and grown by metalorganic chemical vapor deposition on an AlN bulk substrate and on two different quality AlN/sapphire templates, and APDs were fabricated and tested. The APD devices with a circular diameter of 20 μm have demonstrated a distinctive reverse-bias breakdown behavior. The reverse breakdown voltage of the APDs is approximately -140 V, which corresponds to a breakdown electric field of 6–6.2 MV/cm for the Al 0.6 Ga 0.4 N material as estimated by Silvaco TCAD simulation. The APDs grown on the AlN bulk substrate show the lowest leakage current density of < 1 × 10 -8 A/cm 2 (at low reverse bias) compared to that of the devices grown on the AlN templates. From the photocurrent measurement, a maximum gain (current limited) of 1.2 × 10 4 is calculated. The average temperature coefficients of the breakdown voltage are negative for APD devices fabricated from both the AlN bulk substrate and the AlN templates, but these data show that the coefficient is the least negative for the APD devices grown on the low-dislocation-density AlN bulk substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multifold Insights for Power System Dynamics From Data Assimilation: Meeting Current Challenges

The world’s electric power grids have evolved over the last 120 years from a single power line to today’s large networks. The evolution will continue at an accelerated rate with extensive smart grid development worldwide. Here for example, the U.S. government has set a goal of reaching 100 percent carbon pollution-free electricity by 2035, while the Department of Energy (DOE) shared a goal to deploy 30 GW and 110 GW of offshore wind by 2030 and 2050, respectively. To meet such ambitious goals, in the years to come, a significant percentage of electricity will come from intermittent renewable sources, electric vehicles (EVs), and be supplied to a vast number of loads that will actively respond to grid conditions and incentive signals. This development is largely driven by environmental and economic factors, such as reducing carbon emissions and saving electricity cost for consumers. These energy resources lead to new uncertain behaviors and dynamics which the grid has never seen and were not considered in its design. Operating such a dynamic grid with sufficient reliability and efficiency is a monumental challenge.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extreme Weather and Climate Vulnerabilities of the Electric Grid: A Summary of Environmental Sensitivity Quantification Methods

Climate hazards and extreme weather affect all components of the electric grid system, from generation to end use. Increasing temperatures, decreasing water availability, more intense storm events, and sea level rise affect the ability of the electric grid to produce and transmit electricity from fossil, nuclear, and existing and emerging renewable energy sources. Most electricity infrastructure is built for past or current climate conditions. Due to long lifetimes, electricity systems are likely to be exposed more frequently to more extreme climate conditions than those for which they were designed, and may not operate as intended under changing climate conditions. Utilities, regulators, state energy offices, and other electricity system planners are beginning to conduct environmental risk assessments, develop climate resilience plans, and incorporate changing climate conditions into long-term planning processes. Here, we highlight the analytical resources available for sensitivity assessment of electrical grid components under extreme weather and climate, and identify gaps in the literature on quantitative methods available for assessment of component vulnerability.

Dumas, Melissa↗

Statistical Profiles of E1 EMP Coupling to Single Conductors

An electro-magnetic pulse (EMP) event can induce large currents and voltages on electrical conductors such as electrical power transmission lines which span many kilometers and the shorter lines typically tens of meters in length used to monitor equipment controlling the power grid. The exact current and voltage induced on a conductor depends on many factors, such as line height, diameter and length as well as ground conductivity and the location of the EMP event relative to the conductor. The current work focus on the line location and orientation relative to the EMP source. A statistical, Monte-Carlo approach is used in sampling the line configuration and then calculating the induced current and voltage. Thousands of EMP events are simulated on the region of the Earth where the EMP event can couple to a given above-ground conductor and the resulting current and voltage is then calculated on that conductor. Through the many simulations, one can assemble statistics on the insult including the peak value, rise time and pulse width.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bench-Scale Development of Promoted High-Capacity Structured Sorbents (Final Technical Report)

The project objective was to develop high-capacity structured sorbent capable of achieving low CO 2 removal from air. The sorbent framework consists of an amine-functionalized onto hydrophobic polymer backbone with an added promoter. The functionalized amine provides high CO 2 capacity and adsorption rates and the polymer backbone to reduce water uptake. For the sorbent development, multiple functionalized amines and promoters were assessed to select a candidate that achieved high CO 2 capacity, high adsorption rate, and high stability. A sorbent-coated filter design was selected as the structured sorbent, which provides high sorbent loading capacity and contains an electrically conductive nonwoven filter substrate that can be Joule-heated to provide efficient utilization of available electricity for sorbent regeneration. A commercial partner operated a pilot filter manufacturing line to produce the filter panels coated with the developed sorbent. A 1 kg CO 2 /day bench unit was designed and fabricated to test the structured filter sorbent. The key achievements from the structured sorbent development activity were demonstrating that existing filter industrial-scale processes can be used for manufacturing Susteon’s structured sorbent and completing a proof-of-concept demonstration of the commercially manufactured structured sorbent filters for CO 2 capture from air with direct, Joule-heated regeneration. A techno-economic assessment with sensitivity analysis was conducted on a 100,000 TPY facility with 85% operating capacity. Through sorbent optimization and process design improvements, it is estimated that the cost of capture was reduced from $\$$349/tCO 2 to $\$$241/tCO 2 . The TEA projects further reductions to $165/tCO 2 through enhancements in CO 2 adsorption rate and sorbent capacity and reducing manufacturing and scale up risks. A life cycle analysis was conducted on the same 100,000 TPY facility and confirmed that the facility’s electricity demand drives its greenhouse gas impact. It was determined that electricity supplied through the current grid mix would result in net-positive CO 2 emissions and that achieving net-negative emissions is only possible by powering the system with renewable electricity or fossil fuel sources equipped with carbon capture and sequestration.

36 MATERIALS SCIENCE↗

Solar Storm GIC Forecasting: Solar Shield Extension Development of the End-User Forecasting System Requirements

A NASA Goddard Space Flight Center Heliophysics Science Division-led team that includes NOAA Space Weather Prediction Center, the Catholic University of America, Electric Power Research Institute (EPRI), and Electric Research and Management, Inc., recently partnered with the Department of Homeland Security (DHS) Science and Technology Directorate (S&T) to better understand the impact of Geomagnetically Induced Currents (GIC) on the electric power industry. This effort builds on a previous NASA-sponsored Applied Sciences Program for predicting GIC, known as Solar Shield. The focus of the new DHS S&T funded effort is to revise and extend the existing Solar Shield system to enhance its forecasting capability and provide tailored, timely, actionable information for electric utility decision makers. To enhance the forecasting capabilities of the new Solar Shield, a key undertaking is to extend the prediction system coverage across Contiguous United States (CONUS), as the previous version was only applicable to high latitudes. The team also leverages the latest enhancements in space weather modeling capacity residing at Community Coordinated Modeling Center to increase the Technological Readiness Level, or Applications Readiness Level of the system http://www.nasa.gov/sites/default/files/files/ExpandedARLDefinitions4813.pdf.

space weather↗

Low-Temperature Annealing of Lightly Doped n-4H-SiC Layers after Irradiation with Fast Electrons

The effect of low-temperature (up to 600°C) isothermal and isochronous annealing on the electrical characteristics of irradiated n-4H-SiC JBS Schottky diodes is studied. Irradiation is performed with 0.9-MeV electrons at a dose of 1 × 10{sup 16} cm{sup –2}. It is shown that the forward current–voltage (I–V) and capacitance–voltage (C–V) characteristics of the irradiated diodes are mainly restored at annealing temperatures of up to 300°C. As the annealing temperature is raised to 500°C, nearly 90% of the defects introduced by irradiation with fast electrons are annealed out. The possible recommended mode of stabilizing annealing to be used in radiation-defect engineering (RDE) is 500°C, 30 min.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Saturation of the Electric Field Transmitted to the Magnetosphere

We reexamined the processes leading to saturation of the electric field, transmitted into the Earth's ionosphere from the solar wind, incorporating features of the coupled system previously ignored. We took into account that the electric field is transmitted into the ionosphere through a region of open field lines, and that the ionospheric conductivity in the polar cap and auroral zone may be different. Penetration of the electric field into the magnetosphere is linked with the generation of the Alfven wave, going out from the ionosphere into the solar wind and being coupled with the field-aligned currents at the boundary of the open field limes. The electric field of the outgoing Alfven wave reduces the original electric field and provides the saturation effect in the electric field and currents during strong geomagnetic disturbances, associated with increasing ionospheric conductivity. The electric field and field-aligned currents of this Alfven wave are dependent on the ionospheric and solar wind parameters and may significantly affect the electric field and field-aligned currents, generated in the polar ionosphere. Estimating the magnitude of the saturation effect in the electric field and field-aligned currents allows us to improve the correlation between solar wind parameters and resulting disturbances in the Earth's magnetosphere.

Lyatsky, Wladislaw↗

Electric propulsion status and development plans - NASA programs

The current status of the NASA auxiliary and primary electric propulsion programs is reviewed. Plans for continuation of these programs and future target goals are also outlined. In auxiliary propulsion, progress on the ion engine flight experiment for the Application Technology Satellite (ATS)-F launch in 1974 to demonstrate North-South station keeping capability is reviewed. In addition, work on small pulsed plasma thrusters and hydrazine resistojets for attitude control applications are also described. In primary propulsion, the effort aimed at demonstrating the technology for solar electric propulsion is presented.

Lazar, J.↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices

Here, we present the design and implementation of a measurement system that enables parallel drive and detection of small currents and voltages at numerous electrical contacts to a multi-terminal electrical device. This system, which we term a feedback lock-in, combines digital control-loop feedback with software-defined lock-in measurements to dynamically source currents and measure small, pre-amplified potentials. The effective input impedance of each current/voltage probe can be set via software, permitting any given contact to behave as an open-circuit voltage lead or as a virtually grounded current source/sink. This enables programmatic switching of measurement configurations and permits measurement of currents at multiple drain contacts without the use of current preamplifiers. Our 32-channel implementation relies on commercially available digital input/output boards, home-built voltage preamplifiers, and custom open-source software. With our feedback lock-in, we demonstrate differential measurement sensitivity comparable to a widely used commercially available lock-in amplifier and perform efficient multi-terminal electrical transport measurements on twisted bilayer graphene and SrTiO 3 quantum point contacts. The feedback lock-in also enables a new style of measurement using multiple current probes, which we demonstrate on a ballistic graphene device.

47 OTHER INSTRUMENTATION↗

MECA Electrometer: An Old Instrument Finds a New Application

The Mars '01 binder contains an electrometer designed to evaluate the electrostatic nature of the Martian regolith (soil) and atmosphere. The electrometer is part of MECA (Mars Environmental Compatibility Assessment) project. The objective is to gain a better understanding of the hazards related to the human exploration of Mars. The electrometer was designed to fit into the heel of the scoop of the robotic arm. The instrument has four sensor types: (a) triboelectric field, (b) electric-field, (c) ion current, and (d) temperature. The triboelectric field sensor array contains five insulating materials to determine material charging effects as the scoop is dragged through the Martian regolith. The sensor has an electric field sensitivity of 35 kV/cm-V and room temperature drift of approx.3 micro V/sec. The sensor has been operated as low as -60 C where the drift is undetected. This talk with focus on the operating principles of the triboelectric sensors and present some of test results.

Buehler, Martin↗