Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Radio detection of air showers with the ARIANNA experiment on the Ross Ice Shelf

The ARIANNA hexagonal radio array (HRA) is an experiment in its pilot phase designed to detect cosmogenic neutrinos of energies above 10 16 eV. The most neutrino-like background stems from the radio emission of air showers. Here this article reports on dedicated efforts of simulating and detecting the signals of cosmic rays. A description of the fully radio self-triggered data-set, the properties of the detected air shower signals in the frequency range of 100–500 MHz and the consequences for neutrino detection are given. 38 air shower signals are identified by their distinct waveform characteristics, are in good agreement with simulations and their signals provide evidence that neutrino-induced radio signals will be distinguishable with high efficiency in ARIANNA. The cosmic ray flux at a mean energy of 6.5$_{-1.0}^{+1.2} $×10 17 eV is measured to be 1.1$_{-0.7}^{+1.0} $ ×10 -16 eV -1 km -2 sr -1 yr -1 and one five-fold coincident event is used to illustrate the capabilities of the ARIANNA detector to reconstruct arrival direction and energy of air showers.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of early stage atherosclerotic plaques using PET and CT fusion imaging targeting P-selectin in low density lipoprotein receptor-deficient mice

Highlights: ► P-selectin regulates leukocyte recruitment as an early stage event of atherogenesis. ► We developed an antibody-based molecular imaging probe targeting P-selectin for PET. ► This is the first report on successful PET imaging for delineation of P-selectin. ► P-selectin is a candidate target for atherosclerotic plaque imaging by clinical PET. -- Abstract: Background: Sensitive detection and qualitative analysis of atherosclerotic plaques are in high demand in cardiovascular clinical settings. The leukocyte–endothelial interaction mediated by an adhesion molecule P-selectin participates in arterial wall inflammation and atherosclerosis. Methods and results: A {sup 64}Cu-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid conjugated anti-P-selectin monoclonal antibody ({sup 64}Cu-DOTA-anti-P-selectin mAb) probe was prepared by conjugating an anti-P-selectin monoclonal antibody with DOTA followed by {sup 64}Cu labeling. Thirty-six hours prior to PET and CT fusion imaging, 3 MBq of {sup 64}Cu-DOTA-anti-P-selectin mAb was intravenously injected into low density lipoprotein receptor-deficient Ldlr-/- mice. After a 180 min PET scan, autoradiography and biodistribution of {sup 64}Cu-DOTA-anti-P-selectin monoclonal antibody was examined using excised aortas. In Ldlr-/- mice fed with a high cholesterol diet for promotion of atherosclerotic plaque development, PET and CT fusion imaging revealed selective and prominent accumulation of the probe in the aortic root. Autoradiography of aortas that demonstrated probe uptake into atherosclerotic plaques was confirmed by Oil red O staining for lipid droplets. In Ldlr-/- mice fed with a chow diet to develop mild atherosclerotic plaques, probe accumulation was barely detectable in the aortic root on PET and CT fusion imaging. Probe biodistribution in aortas was 6.6-fold higher in Ldlr-/- mice fed with a high cholesterol diet than in those fed with a normal chow diet. {sup 64}Cu-DOTA-anti-P-selectin mAb accumulated selectively in aortic atherosclerotic plaques and was detectable by PET and CT fusion imaging in Ldlr-/- mice. Conclusions: P-selectin is a candidate target molecule for early-phase detection by PET and CT fusion imaging of atherosclerotic plaques.

60 APPLIED LIFE SCIENCES↗

Detection of N-glycolylneuraminic acid biomarkers in sera from patients with ovarian cancer using an engineered N-glycolylneuraminic acid-specific lectin SubB2M

Highlights: • N-glycolylneuraminic acid (Neu5Gc) has been proposed as cancer biomarker. • A Neu5Gc-specific lectin, SubB2M, was used to detect Neu5Gc in patient sera. • Serum from ovarian cancer patients has significantly elevated Neu5Gc levels. • Late stage ovarian cancer patients have uniformly elevated levels of Neu5Gc-glycans. N-glycolylneuraminic acid (Neu5Gc)-containing glycans are a prominent form of aberrant glycosylation found in human tumor cells and have been proposed as cancer biomarkers. The B subunit of the subtilase cytotoxin (SubB) produced by Shiga toxigenic Escherichia coli recognises Neu5Gc containing glycans. We have previously engineered this lectin, SubB2M, for greater specificity and enhanced recognition of Neu5Gc-containing glycans. Here we further explore the utility of SubB2M to detect Neu5Gc tumor biomarkers in sera from patients with ovarian cancer. Using surface plasmon resonance (SPR) we show that SubB2M can detect the established ovarian cancer biomarker, CA125, in a highly sensitive and specific fashion in the context of human serum. These studies established conditions for screening serum samples from patients with ovarian cancer for Neu5Gc glycans. We found that serum from patients with all stages of ovarian cancer had significantly elevated mean levels of Neu5Gc glycans compared to normal controls. Serum from patients with late stage disease (stages IIIC, IV) had uniformly elevated levels of Neu5Gc glycans. Detection of Neu5Gc-glycans using SubB2M has the potential to be used as a diagnostic ovarian cancer biomarker, as well as a tool for monitoring treatment and disease progression in late stage disease.

60 APPLIED LIFE SCIENCES↗

Out-of-distribution detection with non-parametric density estimation for models predicting processing history of uranium ore concentrates

The rapid advancement in machine learning (ML) and computer vision (CV) coincides with the growth of interest in deploying these ML/CV models in numerous fields from medicine to social science. Similar to those areas, we have witnessed a great number of works in materials science employing ML/CV models – neural networks in particular – in their studies in recent years. These models have proven to obtain accurate performance in various tasks. However, these models struggle to attain a similar performance when encountering test samples coming from a distribution that is different from the training set. More importantly, they fail without providing any warning to the users. Therefore, we propose a framework for detecting out-of-distribution (OOD) samples to alert users when a human intervention might be necessary in this work. Specifically, we explore the use of a non-parametric density estimation method to detect OOD samples. Here, we assess OOD detection capability of the proposed framework on ML models developed for categorizing precipitation routes of U 3 O 8 when encountering OOD datasets that contain samples (1) undergone different imaging acquisition process, (2) undergone different material synthesis process, and (3) different materials than ID set. Through those experiments, we achieve an average area under the receiver operating characteristic (AUROC) of at least 91% on average in detecting OOD samples. With minimal overhead cost and superior performance, the proposed framework enables a reliable and safe system when deploying in real-world scenarios.

Convolutional neural networks↗

Under-detection of endospore-forming Firmicutes in metagenomic data

Microbial diversity studies based on metagenomic sequencing have greatly enhanced our knowledge of the microbial world. However, one caveat is the fact that not all microorganisms are equally well detected, questioning the universality of this approach. Firmicutes are known to be a dominant bacterial group. Several Firmicutes species are endospore formers and this property makes them hardy in potentially harsh conditions, and thus likely to be present in a wide variety of environments, even as residents and not functional players. While metagenomic libraries can be expected to contain endospore formers, endospores are known to be resilient to many traditional methods of DNA isolation and thus potentially undetectable. In this study we evaluated the representation of endospore-forming Firmicutes in 73 published metagenomic datasets using two molecular markers unique to this bacterial group ( spo0A and gpr ). Both markers were notably absent in well-known habitats of Firmicutes such as soil, with spo0A found only in three mammalian gut microbiomes. A tailored DNA extraction method resulted in the detection of a large diversity of endospore-formers in amplicon sequencing of the 16S rRNA and spo0A genes. However, shotgun classification was still poor with only a minor fraction of the community assigned to Firmicutes . Thus, removing a specific bias in a molecular workflow improves detection in amplicon sequencing, but it was insufficient to overcome the limitations for detecting endospore-forming Firmicutes in whole-genome metagenomics. In conclusion, this study highlights the importance of understanding the specific methodological biases that can contribute to improve the universality of metagenomic approaches.

59 BASIC BIOLOGICAL SCIENCES↗

Development and Evaluation of HVAC Operation Schedule Detection Algorithm

Small- and medium-sized (<50,000 sf) commercial buildings (SMBs) represent over 94% of the U.S. commercial building stock and consume over 1018 kJ (~1015 Btus) of total site energy. Many of these buildings use rudimentary controls that are mostly manual, with limited scheduling capability and no monitoring or failure management. Therefore, many of them are operated inefficiently and consume excess energy. SMBs typically use packaged rooftop units (RTUs) that are controlled by an individual thermostat. Studies have shown that managing set points and schedules of the RTUs will result in up to 20% energy/cost savings. This paper is focused only on the detection of the occupancy schedule using the zone temperature. The paper describes the methodology to detect the occupancy schedule, the metric used to validate the algorithm and the validation results. The algorithm has been tested and validated using field data from a number of RTUs from six buildings in different climate locations. Overall, the algorithm was successful in detecting the occupancy schedule using a symbolic aggregate approximation (SAX) technique. The results showed that the occupancy schedule detection algorithm using the SAX method performs well under summer (hot) and winter (cold) weather conditions when energy use is the highest. The algorithm can also distinguish different schedules and generate clusters of occupancy scheduling based on zone temperature measurements alone.

Kim, Woohyun↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient derivatization of methylphosphonic and aminoethylsulfonic acids related to nerve agents simultaneously in soils using trimethyloxonium tetrafluoroborate for their enhanced, qualitative detection and identification by EI-GC–MS and GC–FPD

Trimethyloxonium tetrafluoroborate (TMO·BF 4 ) has been used here in the simultaneous derivatization of phosphonic and 2-aminoethylsulfonic acids related to nerve agents in different soils for their enhanced detection and identification by electron ionization gas chromatography-mass spectrometry (EI-GC–MS). The panel of acids consisted of five Schedule 2 phosphonic acids (methyl methylphosphonic acid, ethyl methylphosphonic acid, isopropyl methylphosphonic acid, pinacolyl methylphosphonic acid and cyclohexyl methylphosphonic acid) along with two sulfonic acids, N,N-diethyl-2-aminoethylsulfonic acid and N,N-diisopropyl-2-aminoethylsulfonic acid. The acids were converted to their corresponding methyl esters at ambient temperature when present at a 10 μg g -1 concentration in three separate soils: Virginia type A soil, Ottawa sand and Nebraska EPA soil. The concentration of the acids reflects values typically encountered during proficiency tests (PTs) administered annually by the Organisation for the Prohibition of Chemical Weapons (OPCW). Derivatization times to yield detectable signals for the methyl ester products for all the acids was found to vary among all three soil samples, however, it was found that generally the most optimal time across all the matrices involved was 3 h after the addition of TMO·BF 4 . Concomitantly, the analysis of the samples was complemented using GC coupled to flame photometric detection (GC–FPD). The inclusion of GC–FPD in the analysis yielded stronger signals for all seven methylated analytes making their detection after merely 3 h possible relative to the ones initially obtained with EI-GC–MS. Regarding the three soils employed in our study, a greater methylating efficiency was found in the Virginia type A soil and Ottawa sand yielding results that were significantly larger in magnitude to those found during the same time points for the Nebraska EPA soil sample. Prolonged reaction times (up to 72 h) were explored to find the time for the highest yield of methyl ester production were found instead to be deleterious to the process showcasing the importance of the fast yielding nature of the process specifically in situations where time-sensitive analysis is crucial (e.g. OPCW-PT).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Local Cancer Recurrence After Stereotactic Ablative Radiation Therapy for Lung Cancer: Physician Performance Versus Radiomic Assessment

Purpose: Stereotactic ablative radiation therapy (SABR) is a guideline-specified treatment option for early-stage lung cancer. However, significant posttreatment fibrosis can occur and obfuscate the detection of local recurrence. The goal of this study was to assess physician ability to detect timely local recurrence and to compare physician performance with a radiomics tool. Methods and Materials: Posttreatment computed tomography (CT) scans (n=182) from 45 patients treated with SABR (15 with local recurrence matched to 30 with no local recurrence) were used to measure physician and radiomic performance in assessing response. Scans were individually scored by 3 thoracic radiation oncologists and 3 thoracic radiologists, all of whom were blinded to clinical outcomes. Radiomic features were extracted from the same images. Performances of the physician assessors and the radiomics signature were compared. Results: When taking into account all CT scans during the whole follow-up period, median sensitivity for physician assessment of local recurrence was 83% (range, 67%-100%), and specificity was 75% (range, 67%-87%), with only moderate interobserver agreement (κ = 0.54) and a median time to detection of recurrence of 15.5 months. When determining the early prediction of recurrence within <6 months after SABR, physicians assessed the majority of images as benign injury/no recurrence, with a mean error of 35%, false positive rate (FPR) of 1%, and false negative rate (FNR) of 99%. At the same time point, a radiomic signature consisting of 5 image-appearance features demonstrated excellent discrimination, with an area under the receiver operating characteristic curve of 0.85, classification error of 24%, FPR of 24%, and FNR of 23%. Conclusions: These results suggest that radiomics can detect early changes associated with local recurrence that are not typically considered by physicians. This decision support system could potentially allow for early salvage therapy of patients with local recurrence after SABR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-Choline Positron Emission Tomography/Computed Tomography and Multiparametric Magnetic Resonance Imaging for the Detection of Early Local Recurrence of Prostate Cancer Initially Treated by Radiation Therapy: Comparison With Systematic 3-Dimensional Transperineal Mapping Biopsy

Purpose: To compare the diagnostic performance of {sup 18}F-fluorocholine positron emission tomography/computed tomography (FCH-PET/CT), multiparametric prostate magnetic resonance imaging (mpMRI), and a combination of both techniques for the detection of local recurrence of prostate cancer initially treated by radiation therapy. Methods and Materials: This was a retrospective, single-institution study of 32 patients with suspected prostate cancer recurrence who underwent both FCH-PET/CT and 3T mpMRI within 3 months of one another for the detection of recurrence. All included patients had to be cleared for metastatic recurrence. The reference procedure was systematic 3-dimensional (3D)-transperineal prostate biopsy for the final assessment of local recurrence. Both imaging modalities were analyzed by 2 experienced readers blinded to clinical data. The analysis was made per-patient and per-segment using a 4-segment model. Results: The median prostate-specific antigen value at the time of imaging was 2.92 ng/mL. The mean prostate-specific antigen doubling time was 14 months. Of the 32 patients, 31 had a positive 3D-transperineal mapping biopsy for a local relapse. On a patient-based analysis, the detection rate was 71% (22 of 31) for mpMRI and 74% (23 of 31) for FCH-PET/CT. On a segment-based analysis, the sensitivity and specificity were, respectively, 32% and 87% for mpMRI, 34% and 87% for FCH-PET/CT, and 43% and 83% for the combined analysis of both techniques. Accuracy was 64%, 65%, and 66%, respectively. The interobserver agreement was κ = 0.92 for FCH-PET/CT and κ = 0.74 for mpMRI. Conclusions: Both mpMRI and FCH-PET/CT show limited sensitivity but good specificity for the detection of local cancer recurrence after radiation therapy, when compared with 3D-transperineal mapping biopsy. Prostate biopsy still seems to be mandatory to diagnose local relapse and select patients who could benefit from local salvage therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Present and future potential of krypton-85 for the detection of clandestine reprocessing plants for treaty verification

Burnup calculations are applied to determine the amount of krypton-85 that is produced during the irradiation of nuclear fuel. Since krypton-85 is most likely released into the atmosphere during reprocessing to separate plutonium, atmospheric transport modeling is used to calculate the worldwide distribution of krypton-85 concentrations stemming from emissions from declared reprocessing plants. Our results are the basis for scenarios in which emissions from clandestine reprocessing facilities have to be detected against various background levels. We conclude that today’s background imposes heavily on the ability to detect small and medium plutonium separation rates; only high separation rates of 1 SQ per week and higher have a chance to be detected with feasible outlay. A fixed network of monitoring stations seems too costly; instead the high number of samples that are required rather calls for mobile sampling procedures, where air samples are collected at random locations over the world and are analyzed in regional laboratories for their krypton-85 concentration. Furthermore, it is argued that krypton-85 emissions from declared reprocessing activities have to be significantly lowered to enable a worldwide verification of the absence of even smaller clandestine reprocessing. For each scenario the number of samples that have to be taken for probable detection is calculated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of threshold parameters on infrared segmentation methods for porosity detection in electron beam powder bed fusion

In-situ process monitoring has seen significant interest in additive manufacturing to address qualification and certification goals. This is especially prevalent in metal powder bed fusion processes such as electron beam powder bed fusion (PBF-EB), with layer-wise infrared imaging being commonly used to detect defects. Here, this work compares two different segmentation methods (static thresholding and statistical thresholding) used for detecting porosity from in-situ infrared imaging data for PBF-EB. Samples were manufactured at a variety of focus offset values to induce porosity. Then, the segmented infrared images were compared to ex-situ X-ray computed tomography scans, which served as a ground-truth reference for objective evaluation. Through this analysis framework, the influential parameters, static threshold and N-value (number of standard deviations above the mean pixel value), respectively, for both image segmentation methods were analyzed and compared for their effects on porosity detection. With optimal parameter settings, the two methods had similar porosity detection performance, but the statistical method performed better under a larger variety of parameter settings.

Infrared imaging↗

A correlation based fault detection method for short circuits in battery packs

Here this paper presents a fault detection method for short circuits based on the correlation coefficient of voltage curves. The proposed method utilizes the direct voltage measurements from the battery cells, and does not require any additional hardware or effort in modeling during fault detection. Moreover, the inherent mathematical properties of the correlation coefficient ensure the robustness of this method as the battery pack ages or is imbalanced in real applications. In order to apply this method online, the recursive moving window correlation coefficient calculation is adopted to maintain the detection sensitivity to faults during operation. An additive square wave is designed to prevent false positive detections when the batteries are at rest. The fault isolation can be achieved by identifying the overlapped cell in the correlation coefficients with fault flags. Simulation and experimental results validated the feasibility and demonstrated the advantages of this method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Avoiding thermal runaway in lithium-ion batteries using ultrasound detection of early failure mechanisms

Thermal runaway leading to catastrophic failure has slowed the adoption of lithium-ion batteries, highlighting the need for early warning systems. In this work, ultrasound is used to detect physical changes in 0.950 Ah Li-ion battery cells by inducing conditions associated with thermal runaway. Ultrasound signal features are extracted as the batteries are cycled under baseline conditions and subsequently subjected to constant current and voltage overcharges. Two conditions identifying failure are defined: a warning to detect the start of overcharge and an emergency stop (E-stop), to immediately take the battery out of service. Using changes in ultrasound signal features, consistent warning and stopping classifications are applied to all failure experiments. On average, a warning notification was issued after 15% of the overcharge time and an E-stop was triggered after 35% of total overcharge duration before failure. Further testing suggests that it is possible to avoid thermal runaway by reacting to intermediate, warning notifications prior to an immediate E-stop. In other words, not only can detection derived by ultrasound identify battery failure before a catastrophic event, but can also provide early, actionable warnings so that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.

25 ENERGY STORAGE↗

Three luminescent d{sup 10} metal coordination polymers assembled from a semirigid V-shaped ligand with high selective detecting of Cu{sup 2+} ion and nitrobenzene

Three 2D luminescent coordination polymers with helical frameworks, [ZnL{sub 2}]{sub n} (1) and ([ML{sub 2}]·(H{sub 2}O)){sub n} (M=Zn (2), Cd (3)) (HL=4-((2-methyl-1 H-imidazol-1-yl)methyl)benzoic acid), have been assembled under hydro(solvo)thermal conditions. Complex 1 is in chiral space group and displays a rare 2D→2D 2-fold parallel interpenetrated layer network with two types of chiral double helixes. Interestingly, the single crystal structure analyses indicate the coexistence of enantiomers la and 1b in one pot, while the bulk crystallization of 1 are racemic mixtures based on the CD measurement. 2 and 3 are isostructural, in the structure, there are two kinds of 2D chiral helical-layers which stack in an -ABAB- sequence leading to the overall structure are mesomer and achiral. All compounds display intense luminescence in solid state at room temperature with high chemical and thermal stability. More importantly, 1 has been successfully applied in the detection of Cu{sup 2+} ions in aqueous media and nitrobenzene and the probable detecting mechanism was also discussed. - Graphical abstract: Three luminescent d{sup 10} metal coordination polymers with helical-layer based on 4-((2-methyl-1H-imidazol-1-yl)methyl)benzoic acid have been obtained. Compound 1 shows high selective detecting for Cu{sup 2+} ion in aqueous and nitrobenzene. - Highlights: • Three coordination polymers with chiral helical-layer have been obtained. • 1 Can luminescent detect Cu{sup 2+} ion in aqueous media and nitrobenzene. • Racemic mixture or mesomer compounds can be obtained by controlling the reaction conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of secondary phases in duplex stainless steel by magnetic force microscopy and scanning Kelvin probe force microscopy

The secondary phase transformations in a commercial super duplex stainless steel were investigated by micro-chemical analyses and high resolution scanning probe microscopy. Energy dispersive X-ray and electron probe detected ferrite and austenite as well as secondary phases in unetched aged duplex stainless steel type 25Cr-7Ni-3Mo. Volta potential indicated that nitride and sigma appeared more active than ferrite, while secondary austenite and austenite presented a nobler potential. Reversal order in nobility is thought to be attributable to the potential ranking provided by oxide nature diversity as a result of secondary phase surface compositions on steel. After eutectoid transformation, secondary austenite was detected by electron probe microanalysis, whereas atomic force microscopy distinguished this phase from former austenite by image contrast. Magnetic force microscopy revealed a “ghosted” effect on the latter microstructure probably derived from metal memory reminiscence of mechanical polishing at passivity and long range magnetic forces of ferrite phase. - Highlights: • Nobility detection of secondary phases by SKPFM in DSS particles is not a straightforward procedure. • As Volta potential and contrast are not always consistent SKPFM surface oxides is thought played an important role in detection. • AFM distinguished secondary austenite from former austenite by image contrast though SEM required EPMA.

36 MATERIALS SCIENCE↗

Monitoring and flaw detection during wire-based directed energy deposition using in-situ acoustic sensing and wavelet graph signal analysis

The goal of this work is to detect flaw formation in the wire-based directed energy deposition (W-DED) process using in-situ sensor data. The W-DED studied in this work is analogous to metal inert gas electric arc welding. The adoption of W-DED in industry is limited because the process is susceptible to stochastic and environmental disturbances that cause instabilities in the electric arc, eventually leading to flaw formation, such as porosity and suboptimal geometric integrity. Moreover, due to the large size of W-DED parts, it is difficult to detect flaws post-process using non-destructive techniques, such as X-ray computed tomography. Accordingly, the objective of this work is to detect flaw formation in W-DED parts using data acquired from an acoustic (sound) sensor installed near the electric arc. To realize this objective, we develop and apply a novel wavelet integrated graph theory approach. The approach extracts a single feature called graph Laplacian Fiedler number from the noise-contaminated acoustic sensor data, which is subsequently tracked in a statistical control chart. Using this approach, the onset of various types of flaws are detected with a false alarm rate less-than 2%. This work demonstrates the potential of using advanced data analytics for in-situ monitoring of W-DED.

42 ENGINEERING↗

K-region tetrasubstituted deep-blue pyrene-based luminogens: Visual detection of trace nitroaniline

In recent years, fluorescence sensors have been widely used in explosive detection due to their portability and high efficiency. Here, in the present work, two K-region tetrasubstituted deep-blue pyrene-based luminogens were designed and synthesized by introducing electron-donating groups. The optical properties were investigated by experimental and density functional theory (DFT) methods. Reasonable luminescence efficiency and electron rich characteristic allowed for the possible detection of nitro-explosives. Both luminogens, especially TFPy, exhibit a sensitive response towards nitroanilines (NA), with a limit of detection (LOD) for p-NA as low as 2.75 × 10 –8 M, which is mainly attributed to the electron-donating substituents on the periphery of the pyrene core and the extended π-conjugated structure. These research results establish a low-cost and simple strategy for the detection of trace nitroaniline.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗