Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “design space approximation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Development of a unit cell for a Ge:Ga detector array

Two modules of gallium-doped germanium (Ge:Ga) infrared detectors with integrated multiplexing readouts and supporting drive electronics were designed and tested. This development investigated the feasibility of producing two-dimensional Ge:Ga arrays by stacking linear modules in a housing capable of providing uniaxial stress for enhanced long-wavelength response. Each module includes 8 detectors (1x1x2 mm) mounted to a sapphire board. The element spacing is 12 microns. The back faces of the detector elements are beveled with an 18 deg angle, which was proved to significantly enhance optical absorption. Each module includes a different silicon metal-oxide semiconductor field effect transistor (MOSFET) readout. The first circuit was built from discrete MOSFET components; the second incorporated devices taken from low-temperature integrated circuit multiplexers. The latter circuit exhibited much lower stray capacitance and improved stability. Using these switched-FET circuits, it was demonstrated that burst readout, with multiplexer active only during the readout period, could successfully be implemented at approximately 3.5 K.

Source record↗

Enhanced Lighting Techniques and Augmented Reality to Improve Human Task Performance

One of the most versatile tools designed for use on the International Space Station (ISS) is the Special Purpose Dexterous Manipulator (SPDM) robot. Operators for this system are trained at NASA Johnson Space Center (JSC) using a robotic simulator, the Dexterous Manipulator Trainer (DMT), which performs most SPDM functions under normal static Earth gravitational forces. The SPDM is controlled from a standard Robotic Workstation. A key feature of the SPDM and DMT is the Force/Moment Accommodation (FMA) system, which limits the contact forces and moments acting on the robot components, on its payload, an Orbital Replaceable Unit (ORU), and on the receptacle for the ORU. The FMA system helps to automatically alleviate any binding of the ORU as it is inserted or withdrawn from a receptacle, but it is limited in its correction capability. A successful ORU insertion generally requires that the reference axes of the ORU and receptacle be aligned to within approximately 0.25 inch and 0.5 degree of nominal values. The only guides available for the operator to achieve these alignment tolerances are views from any available video cameras. No special registration markings are provided on the ORU or receptacle, so the operator must use their intrinsic features in the video display to perform the pre-insertion alignment task. Since optimum camera views may not be available, and dynamic orbital lighting conditions may limit viewing periods, long times are anticipated for performing some ORU insertion or extraction operations. This study explored the feasibility of using augmented reality (AR) to assist with SPDM operations. Geometric graphical symbols were overlaid on the end effector (EE) camera view to afford cues to assist the operator in attaining adequate pre-insertion ORU alignment.

Maida, James C.↗

A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators

Purpose: Using magnetic resonance imaging (MRI) for real-time guidance during radiotherapy is an active area of research and development. One aspect of the problem is the influence of the MRI scanner, modeled here as an external magnetic field, on the medical linear accelerator (linac) components. The present work characterizes the behavior of two medical linac electron guns with external magnetic fields for in-line and perpendicular orientations of the linac with respect to the MRI scanner. Methods: Two electron guns, Litton L-2087 and Varian VTC6364, are considered as representative models for this study. Emphasis was placed on the in-line design approach in which case the MRI scanner and the linac axes of symmetry coincide and assumes no magnetic shielding of the linac. For the in-line case, the magnetic field from a 0.5 T open MRI (GE Signa SP) magnet with a 60 cm gap between its poles was computed and used in full three dimensional (3D) space charge simulations, whereas for the perpendicular case the magnetic field was constant. Results: For the in-line configuration, it is shown that the electron beam is not deflected from the axis of symmetry of the gun and the primary beam current does not vanish even at very high values of the magnetic field, e.g., 0.16 T. As the field strength increases, the primary beam current has an initial plateau of constant value after which its value decreases to a minimum corresponding to a field strength of approximately 0.06 T. After the minimum is reached, the current starts to increase slowly. For the case when the beam current computation is performed at the beam waist position the initial plateau ends at 0.016 T for Litton L-2087 and at 0.012 T for Varian VTC6364. The minimum value of the primary beam current is 27.5% of the initial value for Litton L-2087 and 22.9% of the initial value for Varian VTC6364. The minimum current is reached at 0.06 and 0.062 T for Litton L-2087 and Varian VTC6364, respectively. At 0.16 T the beam current increases to 40.2 and 31.4% from the original value of the current for Litton L-2087 and Varian VTC6364, respectively. In contrast, for the case when the electron gun is perpendicular to the magnetic field, the electron beam is deflected from the axis of symmetry even at small values of the magnetic field. As the strength of the magnetic field increases, so does the beam deflection, leading to a sharp decrease of the primary beam current which vanishes at about 0.007 T for Litton L-2087 and at 0.006 T for Varian VTC6364, respectively. At zero external field, the beam rms emittance computed at beam waist is 1.54 and 1.29{pi}-mm-mrad for Litton L-2087 and Varian VTC6364, respectively. For the in-line configuration, there are two particular values of the external field where the beam rms emittance reaches a minimum. Litton L-2087 rms emittance reaches a minimum of 0.72{pi} and 2.01{pi}-mm-mrad at 0.026 and 0.132 T, respectively. Varian VTC6364 rms emittance reaches a minimum of 0.34{pi} and 0.35{pi}-mm-mrad at 0.028 and 0.14 T, respectively. Beam radius dependence on the external field is shown for the in-line configuration for both electron guns. Conclusions: 3D space charge simulation of two electron guns, Litton L-2087 and Varian VTC6364, were performed for in-line and perpendicular external magnetic fields. A consistent behavior of Pierce guns in external magnetic fields was proven. For the in-line configuration, the primary beam current does not vanish but a large reduction of beam current (up to 77.1%) is observed at higher field strengths; the beam directionality remains unchanged. It was shown that for a perpendicular configuration the current vanishes due to beam bending under the action of the Lorentz force. For in-line configuration it was determined that the rms beam emittance reaches two minima for relatively high values of the external magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing Occupant Light Exposure in Factory and Office Spaces

There is an increasing desire to provide healthy workplace environments that better serve people while minimizing the impact on the planet. Building recommendations help designers to incorporate the latest research and best practices, but translating research studies conducted in different settings to broader recommendations is challenging. This is particularly true for lighting, with researchers continuing to learn more about circadian, neuroendocrine, and neurobehavioral responses to light. The recommendations are regularly adjusting to incorporate the latest research as well as feedback from practitioners implementing these recommendations. There remains a need to better document the actual light exposure that people experience over the course of a day and across seasons, so that researchers can better understand the influence of light on people and recommendations can be refined. Thankfully, advances in sensor technology are making this more possible than ever. PNNL collaborated with ETC Inc. to understand actual occupant light exposure in factory and office spaces at ETC’s Headquarters in Middleton, WI. The primary building at ETC headquarters opened in 2004 and houses approximately 800 employees that contribute to central business functions, customer support, research and development, as well as the company’s primary 60,000 ft2 manufacturing facility. Vertical light exposure measurements including electric light and daylight were recorded in factory, research and development, and office work areas at occupant eye height. This document will focus on lighting measurements collected in six factory and office locations across work location, season, and time of day. Ultimately, detailed lighting measurements can be coupled with employee surveys to support development of satisfactory work environments.

42 ENGINEERING↗

Developing Ultra Reliable Life Support for the Moon and Mars

Recycling life support systems can achieve ultra reliability by using spares to replace failed components. The added mass for spares is approximately equal to the original system mass, provided the original system reliability is not very low. Acceptable reliability can be achieved for the space shuttle and space station by preventive maintenance and by replacing failed units, However, this maintenance and repair depends on a logistics supply chain that provides the needed spares. The Mars mission must take all the needed spares at launch. The Mars mission also must achieve ultra reliability, a very low failure rate per hour, since it requires years rather than weeks and cannot be cut short if a failure occurs. Also, the Mars mission has a much higher mass launch cost per kilogram than shuttle or station. Achieving ultra reliable space life support with acceptable mass will require a well-planned and extensive development effort. Analysis must define the reliability requirement and allocate it to subsystems and components. Technologies, components, and materials must be designed and selected for high reliability. Extensive testing is needed to ascertain very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The systems must be designed, produced, integrated, and tested without impairing system reliability. Maintenance and failed unit replacement should not introduce any additional probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass must start soon if it is to produce timely results for the moon and Mars.

Jones, Harry W.↗

Radar Observations from the Haystack Ultrawideband Satellite Imaging Radar in 2019

The NASA Orbital Debris Program Office (ODPO) relies primarily on ground-based radar measurements to characterize the distribution of small debris, down to approximately 3 mm depending upon altitude and the sensor used, in low Earth orbit (LEO). Since the early 1990’s, the Massachusetts Institute of Technology (MIT) Lincoln Laboratory (LL) has been collecting radar measurements for the NASA ODPO under agreements with the U.S. Department of Defense. The Haystack Ultrawideband Satellite Imaging Radar (HUSIR) is the primary ground-based radar sensor used by the ODPO and provides data on orbital debris down to an approximate size of 5.5 mm below 1000km altitude using the NASA size estimation model (SEM). Since orbital debris of this size are a significant risk to both human and robotic missions in LEO, the sensitivity of this radar makes it a high-value sensor. The NASA ODPO radar measurements are conducted on a continual basis for monitoring and enabling modeling of the orbital debris environment over time. HUSIR observations from 2019 are the most recent snapshot of the environment that has been measured and analyzed to date. In recent years, HUSIR measurements indicated relatively stable populations for the orbital debris objects that it is able to detect. In 2019, several interesting events happened on-orbit, including the start of large constellation deployments into LEO, as well as the Indian anti-satellite test with Microsat-R (International Designator 2019-006A, U.S. Strategic Command Space Surveillance Network catalog number 43947). Due to these events, coupled with a general increase in the number of missions and participants launching missions in recent years, continual monitoring is necessary to determine the effects of this increased activity on the orbital debris environment. This paper will explore the results of the 2019 HUSIR radar measurements, including above-average flux measurements at lower LEO altitudes and the evolution of the flux during the time of observations.

James Murray↗

Radar Observations from the Haystack Ultrawideband Satellite Imaging Radar in 2019

The NASA Orbital Debris Program Office (ODPO) relies primarily on ground-based radar measurements to characterize the distribution of small debris, down to approximately 3 mm depending upon altitude and the sensor used, in low Earth orbit (LEO). Since the early 1990’s, the Massachusetts Institute of Technology (MIT) Lincoln Laboratory (LL) has been collecting radar measurements for the NASA ODPO under agreements with the U.S. Department of Defense. The Haystack Ultrawideband Satellite Imaging Radar (HUSIR) is the primary ground-based radar sensor used by the ODPO and provides data on orbital debris down to an approximate size of 5.5 mm below 1000km altitude using the NASA size estimation model (SEM). Since orbital debris of this size are a significant risk to both human and robotic missions in LEO, the sensitivity of this radar makes it a high-value sensor. The NASA ODPO radar measurements are conducted on a continual basis for monitoring and enabling modeling of the orbital debris environment over time. HUSIR observations from 2019 are the most recent snapshot of the environment that has been measured and analyzed to date. In recent years, HUSIR measurements indicated relatively stable populations for the orbital debris objects that it is able to detect. In 2019, several interesting events happened on-orbit, including the start of large constellation deployments into LEO, as well as the Indian anti-satellite test with Microsat-R (International Designator 2019-006A, U.S. Strategic Command Space Surveillance Network catalog number 43947). Due to these events, coupled with a general increase in the number of missions and participants launching missions in recent years, continual monitoring is necessary to determine the effects of this increased activity on the orbital debris environment. This paper will explore the results of the 2019 HUSIR radar measurements, including above-average flux measurements at lower LEO altitudes and the evolution of the flux during the time of observations.

James Murray↗

Broad band X-ray telescope (BBXRT) displacement monitor system (DMS) testing and calibration

NASA's shuttle-borne Broad Band X-Ray Telescope (BBXRT) consists of two glancing incidence imaging mirror assemblies mounted on an optical bench which is bolted to the primary structure of the instrument. The X-ray detectors are located in the focal plane of the mirror assemblies approximately 3.5 meters away. It is desirable to monitor the relative alignment of these components throughout ground testing, and to determine the magnitude of launch or thermally induced perturbations to the alignment during flight. The Displacement Monitor System (DMS) was designed to accomplish this task. This paper describes the design of the DMS, the development and optimization of the DMS calibration facility, and the characterization of the system. The characterization of the DMS includes environmental qualification, displacement vs output calibration over the operating temperature range, a detailed error analysis, and the generation of a calibration polynomial which utilizes DMS detector output and thermocouple data to optimize system performance. The DMS accuracy exceeded the requirements of a 15 arc second limit of error, and passed the stringent environmental tests. As such, the DMS is one of the first flight qualified displacement monitor systems with this accuracy to be flown in space.

Hagopian, John G.↗

Operational overview of the NASA GTE/CITE 3 airborne instrument intercomparisons for sulfur dioxide, hydrogen sulfide, carbonyl sulfide, dimethyl sulfide, and carbon disulfide

This paper reports the overall experimental design and gives a brief overview of results from the third airborne Chemical Instrumentation Test and Evaluation (CITE 3) mission conducted as part of the National Aeronautics and Space Administration's Global Tropospheric Experiment. The primary objective of CITE 3 was to evaluate the capability of instrumentation for airborne measurements of ambient concentrations of SO2, H2S, CS, dimethyl sulfide, and carbonyl sulfide. Ancillary measurements augmented the intercomparison data in order to address the secondary objective of CITE 3 which was to address specific issues related to the budget and photochemistry of tropospheric sulfur species. The CITE 3 mission was conducted on NASA's Wallops Flight Center Electra aircraft and included a ground-based intercomparison of sulfur standards and intercomparison/sulfur science flights conducted from the NASA Wallops Flight Facility, Wallops Island, Virginia, followed by flights from Natal, Brazil. Including the transit flights, CITE 3 included 16 flights encompassing approximately 96 flight hours.

Hoell, James M., Jr.↗

On the Necessity and Feasibility of an Equatorial Magnetospheric Constellation

Synthesizing multi-point in-situ observations from the magnetosphere is the only way that we can retain an accurate knowledge of the driving mechanisms of convection and energy flow while "imaging" its vast volume. In addition to measuring the wavenumber of plasma instabilities thus opening up for study a previously unexplored domain of space plasma physics the Constellation mission can afford us a view of the rapid topological reconfigurations and the energy circulation throughout the astrophysical laboratory closest to human space activity. In this paper we argue that the deployment of approximately 80 autonomous micro-satellites (probes) to monitor the Earth's magnetosphere and measure the plasma and magnetic field in the near-equatorial magnetosphere is a necessary and sufficient condition for answering long standing, high priority questions regarding magnetospheric stability and dynamics. The proposed mission concept is technically feasible and fiscally modest. The probes can be raised from a Geosynchronous Transfer orbit to their final elliptical orbits with perigee approximately 3R(sub E)and apogees ranging from 12 to 42 R(sub E) by a single dispenser propelled by an ion engine. Each probe will weigh approximately 5 kg. The mission can form a cornerstone of an incrementally deployed Solar Terrestrial Probe Line Magnetospheric Constellation, as it requires no new technologies in the areas of spacecraft subsystems and instruments, but some development in the areas of dispenser design, probe packaging, mechanical release and spin-up. The technology developed can be utilized by follow-on Constellation class missions as well.

Angelopoulos, V.↗

NASA’s Galactic Cosmic Ray Simulator at Brookhaven National Laboratory: Enabling Human Exploration Missions to the Moon and Mars

With exciting new Agency plans for a sustainable return to the moon, astronauts will once again leave earth’s protective magnetosphere only to endure higher levels of radiation from galactic cosmic rays (GCR) and the possibility of a large solar particle event (SPE). Gateway, lunar landers, and surface habitats will be designed to protect crew against SPE’s with vehicle optimization, storm shelter concepts, and/or active dosimetry; however, the ever-penetrating GCR will continue to pose the most significant health risks especially as lunar missions increase in duration and as NASA sets its aspirations on Mars. The primary risks of concern include epithelial carcinogenesis and leukemia, central nervous system effects resulting in potential in-mission cognitive or behavioral impairment and/or late neurological disorders, degenerative tissue effects including cataracts, circulatory and heart disease, as well as, potential immune system decrements impacting multiple aspects of crew health. Characterization and mitigation of these risks requires a significant reduction in the large biological uncertainties of chronic (low-dose rate) heavy ion exposures and the validation of countermeasures in a relevant space environment. NASA has developed the “GCR Simulator” at Brookhaven National Laboratory to generate a spectrum of ion beams that approximates the primary and secondary GCR field experienced at human organ locations within a deep-space vehicle. The majority of the dose is delivered from protons (~65-75%) and alpha particles (~10-20%) with heavier ions (Z≤3) contributing the remainder. The “GCR Simulator” exposes state-of-the art cellular and animal model systems to 33 sequential beams including 4 proton energies plus degrader, 4 helium energies plus degrader, and the five heavy ions of C, O, Si, Ti, and Fe. A polyethylene degrader is used with the 100 MeV/n H and He beams to provide a nearly continuous distribution of low energy particles. A 500 mGy exposure, delivering doses from each of the 33 beams, requires 75-90 minutes. To more closely simulate the low dose rates found in space, sequential field exposures can be divided into daily fractions over 2-4 weeks, with individual fractions as low as 0.1-0.2 mGy. In the large beam configuration (60 x 60 cm(exp 2)), 54 special housing cages can accommodate 2-3 mice each for a 70-75 min duration or ~15 individually housed rats. Emerging research results from our 2018 runs utilizing mixed heavy ion fields and protracted space exposures are forthcoming and deepen our understanding of the numerous health risks faced by our astronauts. This paper discusses NASA’s innovative technology solution for a ground-based GCR simulator at the NASA Space Radiation Laboratory to enable future exploration missions.

Lisa C Simonsen↗

JSC-Rocknest: A Large-Scale Mojave Mars Simulant (MMS) Based Soil Simulant for In-Situ Resource Utilization Water-Extraction Studies

The Johnson Space Center-Rocknest (JSC-RN) simulant was developed in response to a need by NASA's Advanced Exploration Systems (AES) In-Situ Resource Utilization (ISRU) project for a simulant to be used in component and system testing for water extraction from Mars regolith. JSC-RN was designed to be chemically and mineralogically similar to material from the aeolian sand shadow named Rocknest in Gale Crater, particularly the 1-3 wt.% low temperature (<450 ºC) water release as measured by the Sample Analysis at Mars (SAM) instrument on the Curiosity rover. Sodium perchlorate, goethite, pyrite, ferric sulfate, regular and high capacity granular ferric oxide, and forsterite were added to a Mojave Mars Simulant (MMS) base in order to match the mineralogy, evolved gases, and elemental chemistry of Rocknest. Mineral and rock components were sent to the United States Geological Survey (USGS) in Denver for mixing. Approximately 800 kg of JSC-RN was sent back to NASA in 5 gallon buckets, which were subsampled and characterized. All samples of the USGS-produced simulants had similar evolved gas profiles as a small prototype batch of JSC-RN made in JSC laboratories, with the exception of HCl, and were similar in terms of mineralogy and total chemistry. Also, all JSC-RN subsamples were homogenous and had similar mineralogy, total chemistry, and low-temperature evolved gas profiles as the Rocknest aeolian sand shadow examined with Curiosity’s instrument suite on Mars. In particular, the low temperature water releases were similar and the amount of water evolved from JSC-RN at <450 ºC was similar to the water content of Rocknest based on SAM water peak integrations. Overall, JSC-RN is ideally suited for ISRU studies of water extraction of global martian soil due to its excellent agreement with measured properties of martian soils and its proven feasibility for large-scale production.

Simulant↗

NDCX-II, an Induction Linac for HEDP and IFE Research

The Heavy Ion Fusion Science Virtual National Laboratory in the USA is constructing a new Neutralized Drift Compression eXperiment (NDCX-II) at LBNL. This facility is being developed for high energy density physics and inertial fusion energy research. The 12 m long induction linac in NDCX-II will produce a Li{sup +} beam pulse, at energies of 1.2-3 MeV, to heat target material to the warm dense matter regime ({approx} 1 eV). By making use of special acceleration voltage waveforms, 2.5T solenoid focusing, and neutralized drift compression, 20 - 50 nC of beam charge from the ion source will be compressed longitudinally and radially to achieve a subnanosecond pulse length and mm-scale target spot size. The original Neutralized Drift Compression Experiment (NDCX-I) has successfully demonstrated simultaneous radial and longitudinal compression by imparting a velocity ramp to the ion beam, which then drifts in a neutralizing plasma to and through the final focussing solenoid and onto the target. At higher kinetic energy and current, NDCX-II will offer more than 100 times the peak energy fluence on target of NDCX-I. NDCX-II makes use of many parts from the decommissioned Advanced Test Accelerator (ATA) at LLNL. It includes 27 lattice periods between the injector and the neutralized drift compression section (Figure 1). There are 12 energized induction cells, 9 inactive cells which provide drift space, and 6 diagnostic cells which provide beam diagnostics and pumping. Custom pulsed power systems generate ramped waveforms for the first 7 induction cells, so as to quickly compress the beam from 600 ns at the injector down to 70 ns. After this compression, the high voltages of the ATA Blumleins are then used to rapidly add energy to the beam. The Blumleins were designed to match the ferrite core volt-seconds with pulses up to 250 kV and a fixed FWHM of 70 ns. The machine is limited to a pulse repetition rate of once every 20 seconds due to cooling requirements. The NDCX-II beam is highly space-charge dominated. The 1-D ASP code was used to synthesize high voltage waveform for acceleration, while the 3-D Warp particle-in-cell code was used for detailed design of the lattice. The Li{sup +} ion was chosen because its Bragg Peak energy (at {approx} 2 MeV) coincides with the NDCX-II beam energy. The 130 keV injector will have a 10.9 cm diameter ion source. Testing of small (0.64 cm diameter) lithium doped alumino-silicate ion sources has demonstrated the current density ({approx} 1 mA/cm{sup 2}) used in the design, with acceptable lifetime. A 7.6 cm diameter source has been successfully produced to verify that the coating method can be applied to such a large emitting area. The ion source will operate at {approx} 1275 C; thus a significant effort was made in the design to manage the 4 kW heating power and the associated cooling requirements. In modifying the ATA induction cells for NDCX-II, the low-field DC solenoids were replaced with 2.5 T pulsed solenoids. The beam pipe diameter was decreased in order to reduce the axial extent of the solenoid fringe fields and to make room for water cooling. In addition, an outer copper cylinder (water-cooled) was used to exclude the solenoid magnetic flux from the ferrite cores. Precise alignment is essential because the beam has a large energy spread due to the rapid pulse compression, such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. A novel pulsed-wire measurement method is used to align the pulsed solenoid magnets. Alignment accuracy has been demonstrated to within 100 {micro}m of the induction cell axis. The neutralized drift compression region after the last induction cell is approximately 1.2 m long and includes ferroelectric plasma sources (FEPS) fabricated by PPPL similar to those successfully operating in NDCX-I. The 8-T final focus pulsed solenoid, filtered cathodic arc plasma sources (FCAPS), and target chamber from NDCX-I are to be relocated to NDCX-II. The NDCX-II project started in July 2009 and is expected to complete in fall of 2011. As future funds become available, additional induction cells and pulsed power systems will be added to increase the beam energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technologies for aerobraking

Aerobraking is one of the largest contributors to making both lunar and Mars missions affordable. The use of aerobraking/aeroassist over all propulsive approaches saves as much as 60 percent of the initial mass required in low earth orbit (LEO); thus, the number and size of earth to orbit launch vehicles is reduced. Lunar transfer vehicles (LTV), which will be used to transport personnel and materials from LEO to lunar outpost, will aerobrake into earth's atmosphere at approximately 11 km/sec on return from the lunar surface. Current plans for both manned and robotic missions to Mars use aerocapture during arrival at Mars and at return to Earth. At Mars, the entry velocities will range from about 6 to 9.5 km/sec, and at Earth the return velocity will be about 12.5 to 14 km/sec. These entry velocities depend on trajectories, flight dates, and mission scenarios and bound the range of velocities required for the current studies. In order to successfully design aerobrakes to withstand the aerodynamic forces and heating associated with these entry velocities, as well as to make them efficient, several critical technologies must be developed. These are vehicle concepts and configurations, aerothermodynamics, thermal protection system materials, and guidance, navigation, and control systems. The status of each of these technologies are described, and what must be accomplished in each area to meet the requirements of the Space Exploration Initiative is outlined.

Cooper, David M.↗

Flying the Earth Observing Constellations

Prior to the launch of the Earth Observing System (EOS) Terra and Landsat-7 satellites in 1999, the Project Scientists for the two missions and the Earth Science Data and Information System (ESDIS) Project at the Goddard Space Flight Center signed an inter-project agreement document describing their plan to fly in loose formation, approximately 20 minutes within each other. In November 2000, a technology demonstration satellite, Earth Observer-1 (EO-1), was launched into the same orbit as that of Landsat-7 and Terra, with a goal of flying within a minute from Landsat-7. The SAC-C satellite, developed and operated by the government of Argentina, was launched along with EO-1, with a goal of flying near both Terra and Landsat-7. This formation enables the scientists to make use of the scientific synergy among the instruments on the different spacecraft. This group of satellites constitutes the morning constellation, which is led by the Landsat-7, which has a mean local time (MLT) at 10:00 a.m. In May 2002, the EOS Aqua satellite was launched into an orbit with an altitude of 705 km. and a 1:30 p.m. MLT. Two smaller satellites, CALIPSO (a joint U.S./French mission), and CloudSat (a joint NASA/Colorado State University/Air Force mission), plan to fly in tight formation, within 15 seconds of each other. In addition, CALIPSO and CloudSat also plan to be within 30 to 60 seconds of the Aqua satellite. A third satellite, PARASOL, managed by the French Space Agency, CNES, will be placed within a minute of the CALIPSO satellite. In 2004, the Aura satellite will be launched and phased in relation to the Aqua satellite, such that the instruments on Aura will be able to view the same mass of air no later than 8 minutes after the instruments on Aqua have observed it. Representatives from each mission are currently documenting a plan on how they will coordinate on-orbit operations. Why are all these satellites planning to fly as a constellation? The answer is that as a constellation. the scientists will be able to acquire science data not only from their specific instruments on a single satellite, but science data from the other satellites which will have been taken at approximately the same time, thus resulting in coordinated science observation data. This leads to better quality science. This paper describes how the mission design has been driven by the science requirements. The morning and the afternoon constellations present operational challenges, which had not previously been encountered. Operations planning must address not only how the satellites of each constellation operate safely together, but also, how the two constellations fly on the same orbits without interfering with each other as they downlink data to their respective ground stations. This paper describes the operations experience gained from the morning constellation and the planning for the afternoon constellation.

Kelly, Angelita C.↗

Developmental Efforts of an Electrochemical Oxygen Recovery System for Advanced Life Support

The current State of Art (SOA) Environmental Control and Life Support System (ECLSS) oxygen recovery system onboard the International Space Station (ISS) is a complex, heavy, and power consuming system that recovers approximately 50% of the oxygen (O2) from metabolic carbon dioxide (CO2). For future long-duration missions, O2recovery systems will need to be highly reliable, efficient, and recover maximum metabolic CO2. Investigations into various technologies to help meet these requirements for exploration are ongoing; however, most of these proposed technologies ultimately result in a more complex system. A Macrofluidic Electrochemical Reactor (MFECR) is one proposed technology development effort currently underway at NASA Marshall Space Flight Center (MSFC) that has the potential to significantly reduce the complexity of ECLSSO2recovery system. The MFECR operates at standard conditions, giving it an advantage over other technologies being investigated, which require high temperatures resulting in heavy reactors and high power consumption. The MFECR would replace three pieces of hardware for future ECLSS architectures: the current Carbon Dioxide Reduction Assembly (Sabatier reactor), the Plasma Pyrolysis Assembly (PPA), and the Oxygen Generation Assembly(OGA). It is designed to interface directly with the Carbon Dioxide Removal Assembly (CDRA) and the Water Processor Assembly (WPA). This allows for a less complex system and higher reliability than the current SOA as well as reduced power, weight and H2Oconsumption of ECLSS. Here, we will discuss the current development efforts of the MFECR and how this technology may aide in the advancement of future long-duration life support systems.

Brittany R Brown↗

Can classical DEM simultaneously capture compressibility and flowability of milled biomass?

Accurate prediction of the rheological behavior of biomass is essential for the design and operation of hoppers, feeders, and storage systems in biorefineries. This study examines whether the classical, coarse-grained discrete element method (DEM) formulation can simultaneously reproduce the compressibility and flowability of milled herbaceous biomass, using Miscanthus × giganteus as a representative material. The model represents particles as rigid spheres interacting through Hertz-Mindlin elastic-frictional contacts augmented with an area-dependent cohesion term. Laboratory cyclic compression and wedge-shaped hopper discharge experiments were used as calibration benchmarks. Although the model can independently reproduce each behavior by appropriately tuning particle Young's modulus E and cohesion energy density k, an extensive parametric investigation comprising more than 600 simulations reveals that the optimal parameter regions for compression and hopper flow are distinct and non-overlapping in (E, k) space. Surrogate surface analysis further shows that the corresponding objective-function valleys exhibit similar trends but are approximately parallel and spatially offset, precluding a unified calibration within the explored domain. Sensitivity analysis indicates that compressibility is governed predominantly by stiffness and cohesion, whereas the slope of the mass flow rate-opening relation in hopper discharge is primarily controlled by tangential friction. Extensions incorporating particle size distribution and clumped-sphere representations do not eliminate the incompatibility. These results systematically reveal, for the first time, the structural limitation of simplified DEM formulations in representing biomass rheological behavior, underscoring the necessity for models incorporating additional physical mechanisms, such as particle deformability or enhanced interlocking, to achieve unified predictive capability for biomass handling behavior.

09 BIOMASS FUELS↗

Performance of DFT Methods in the Calculation of Optical Spectra of Chromophores

Organic chromophores possessing a high degree of π -conjugation are ideal materials for advanced electronic and photonic applications including optical information processing, photovoltaic cells, photodynamic therapy agents, and many other applications. These properties are due to the stable macrocyclic conjugated network of π -electrons leading to high electrical polarizability and rapid nonlinear optical response (NLO) of the charge density to the applied intense electromagnetic fields. Changing the substitutional groups and substitution pattern, conjugation and molecular electronic structure can conveniently modify the optical spectra and NLO properties of chromophores. Due to almost limitless optimization space of chromophore structures computational tools are increasingly being used to assist experimental efforts in designing the optimal chromophores. By far the most often used computational approaches are semi-empirical and DFT methods. The semiempirical computational methods, such as ZINDO/CIS are fast and accurate for chromophores similar to systems for which the method was parameterized. DFT, on the other hand, offers the best compromise between accuracy and computational performance for typical chromophores of about 100 atoms. The accuracy of the methods depends strongly on the type of chromophores. For example, the ZINDO/CIS method is excellent for polyphenylacetylene dyes, but fails for many cyano-based acceptors of chromophores; DFT may be better suited for tricyanofuranyl complexes but leads to large errors in spectra of the polyphenylacetylene dyes. The failure of DFT calculations has been associated with the incorrect asymptotic behavior of the typical exchange-correlation (XC) potential. The approximate XC potential does not posses the correct 1/r asymptotic behavior, which leads to the self-interaction error (SIE). As a result, the excited states of dyes, in particular the charge-transfer (CT) chromophores are poorly described. A variety of approaches have been developed to treat this problem. The exact (i.e., Hartree Fock (HF)) exchange is frequently added to partially remove the SIE error resulting in several hybrid methods with a constant fraction of HF contribution. The well-known models include B3LYP, PBE1PBE and BH-LYP incorporating 20, 25 and 50% of HF exchange, respectively. Recently, a new class of functionals has been proposed which includes a growing fraction of exact exchange as the distance increases. These long-range (LC) corrected functionals have been found to provide improved correlation between the calculated and experimental optical properties of several dyes. The recently proposed BNL functional, which falls into this LC-class, is of particular interest for studying the push-pull dyes because it has been shown to exactly reproduce the charge-transfer excitation for model systems. In this paper we have implemented the BNL method in the parallel NWCHEM program package and applied it to calculate the optical spectra of highly active NLO chromophores such as 2-dicyanomethylen-3-cuano-4-{2-[E-(4-N,N-di(2-acetoxyethyl)-amino)-phenylene-(3,4-dibutyl)thien-5]-E-vinyl}-5,5-dimethyl-2,5-dihydrofuran (denoted FTC) and YLD_124. Extensive validation of the BNL functional and comparison to other functionals was performed. In addition, a TCV chromophore with a strong acceptor ( tricyanovinyl) and donor (dimethylamine) was also studied. These chromophores allow for accurate validation of the method because the UV-Vis spectra in the entire visual region were recently obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗