Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

The solubility of ErPO 4 and Er speciation in hydrothermal fluids at varying pH and salinity between 350 and 450 °C

The rare earth elements (REE) are important for the green-energy transition and can be incorporated into the REE phosphates, such as xenotime-(Y), which also hosts heavy REE (Tb– Lu). Xenotime-(Y) is a common accessory mineral in metamorphic rocks and a range of mineral deposits where it controls the mobility of heavy REE, however, the impact of high temperature aqueous fluids on the behavior of heavy REE is largely unknown. Thermodynamic modeling can be utilized as a tool to predict the mobility of REE in hydrothermal aqueous fluids, but must be supported by accurate experimental data. Here, we measured the solubility of endmember synthetic xenotime-structured ErPO4 in NaCl-HCl-NaOH-bearing aqueous solutions at 350 °C and water vapor saturation pressure, at 400 and at 450 °C and 500 bar using batch-type Inconel reactors. Erbium speciation was investigated as a function of pH from 2.8 to 8, where Er chloride species are predominant at acidic conditions (pH <3) and Er hydroxyl complexes are predominant at near- neutral to alkaline conditions (pH >3). At pH 7–9, the measured ErPO 4 solubility (-9.8 to -7.5 log m Er ) is up to 2.5 orders of magnitude lower than thermodynamic predictions (-9.4 to -6.7 log m Er ) using existing thermodynamic databases. At pH 2–3, the predicted ErPO 4 solubility is ~0.5 orders of magnitude higher at 350 °C and ~1 order of magnitude lower at 450 °C compared to experimentally measured Er concentrations. The thermodynamic properties of aqueous Er species were therefore revised in this study. The partial molal Gibbs energy of formation (Δ f G 0 T,P ) for aqueous Er hydroxyl and chloride species are optimized using GEMSFITS and the logarithmic formation constants (logβ n ( Cl,OH) ) were derived at each experimental temperature and pressure. The updated thermodynamic properties for Er hydroxyl species (Er(OH) +2 , Er(OH) 2 + , and Er(OH) 3 0 ) show that their stability shifts to more acidic conditions at and below 400 °C. The Er chloride species (ErCl +2 and ErCl 2 + ) show increased stability compared to Er hydroxyl species at temperatures of 450 °C and 0.01 mol/kg NaCl. The updated thermodynamic properties are implemented into the GEM-Selektor modeling package to investigate the mobility of Er in saline hydrothermal fluids in equilibrium with alkaline rocks. Importantly, the updated properties for Er hydroxyl species result in low Er solubility at rock equilibrated pH conditions due to an expanded hydroxyl predominance zone, but lower aqueous complex stability overall, whereas previous models suggest greater stability for aqueous Er species. Furthermore, ErPO 4 solubility increases with decreasing temperature due to the deprotonation of HCl, which increases the acidity of hydrothermal fluids and the availability of Cl - to complex with the REE. These simulations highlight how fluid-rock reaction and temperature affect the mobility of REE in hydrothermal ore-forming systems.

58 GEOSCIENCES↗

Sensitivity Effects of High Temperature Overhead Conductors to Line Rating Variables

For traditional overhead transmission lines, the maximum allowable conductor operating temperature on ASCR, AAC, or AAAC lines for determining the static line ratings can be quite low, typically well under 100 C. At these low temperatures, the primary driver for determining static line ratings are assumptions made about the wind speed and direction and the ambient temperature. Assumptions for solar loading and emitted thermal radiation, driven by line emissivity and absorptivity, are secondary factors, and only provide small changes to the static ratings. However, when considering newer high temperature conductors such as ACSS, ACCR, ZTACIR, and ACCC® the maximum allowable conductor temperatures can be significantly higher, up to 250° C. This higher temperature shifts the importance of the emissivity assumptions of the overhead transmission line, due to the nature of the T4 dependence of the radiative heat loss compared to the T1 dependence of the convective heat loss, as well as shifting the dependency on local wind conditions. Typical assumptions in the United States for the emissivity/absorptivity of overhead transmission lines in determining the static ratings are to use a value of 0.5 for both parameters or set a value in the range of 0.7 to 0.9. Recent experimental tests at EPRI have shown that higher emissivity aging assumptions may not be valid in some regions of the US, and that actual values may be much lower (0.25-0.45) than older studies have predicted (0.8-0.9). Here, the assumptions of different US Regional Transmission Operators (RTOs) and different utilities within RTOs are examined for the static ratings for traditional lower operating temperatures up to 100° C as well as with the higher maximum temperature conductors associated with newer conductor designs at 250° C. The sensitivity of the static ratings is examined at both lower and higher temperature conductors with respect to overhead line emissivity and absorptivity, wind speed, wind direction, and solar loading, and ambient temperature. It is shown that the effects of the conductor absorptivity, solar flux and ambient temperature on the static rating are increased when the transmission line has a lower maximum conductor temperature. The effects of the conductor emissivity, wind direction and wind speed have increased effects on the static rating when the transmission line has a higher maximum conductor temperature. In addition, example weather data is used to calculate the conductor temperature with different line emissivity and absorptivity assumptions. This shows the effect of assumptions made for emissivity only has a minor impact for low temperature lines, but for high temperature transmission lines can cause a 150-200° C temperature swing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated reactor physics analysis framework of High Flux Isotope Reactor low-enriched uranium silicide dispersion fuel designs

The High Flux Isotope Reactor (HFIR) is a versatile research reactor that provides one of the highest steady-state neutron fluxes of any reactor in the world. The HFIR reactor physics team investigated the conversion of the current 93 wt% highly enriched uranium U 3 O 8 -Al dispersion fuel to a 19.75% low-enriched uranium (LEU) U 3 Si 2 -Al dispersion fuel. The team continuously develops a Python module to streamline the analysis steps required for an LEU core design to ensure reproducible and agile design iteration. The Python module automates the data processing between analysis steps and automates the input perturbation for branch calculations and design changes. The automated framework has proven to significantly increase the efficiency and reproducibility of the reactor physics team to design High Flux Isotope Reactor (HFIR) LEU cores and thoroughly analyze performance metrics, safety metrics, and thermal safety margins. Consequently, the team can now respond rapidly to fuel fabrication engineer and thermal-hydraulic-structural analyst requests. Numerous combinations of LEU fuel designs are explored, of which two LEU fuel designs are presented here in this paper: a low density silicide design, and a high-density silicide design. Results show that both designs meet or exceed safety and performance metrics with exception for minor differences caused by the hardened spectrum from LEU.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dissolution of Fluoride Salts in Hanford Tank Waste

The Direct Feed High-Level Waste (DFHLW) strategy seeks to bypass the Hanford Waste Treatment and Immobilization Plant Pretreatment Facility while retaining some processing functions to maximize waste feed loading and minimize high-level waste (HLW) waste volume. The DFHLW flowsheet needs leaching, washing, and solids concentration operations either in new or existing tanks. The effectiveness and efficiency of sludge washing has a substantial impact on DST space, mission duration, and the evaporation and low-activity waste (LAW) treatment operations required by these large wash-water additions. One target species requiring washing is fluoride. The HLW glass composition limits for fluorine drive operations to dissolve fluoride-bearing salts into the LAW fraction and thereby maximize waste loading in HLW glass. The fluoride in many high-level wastes at Hanford is predominantly in the form of fluoride-salt precipitates: villiaumite (NaF), kogarkoite (Na 3 FSO 4 ), and natrophosphate (Na 7 F(PO 4 ) 2 ·19H 2 O). Fluoride produces melter off-gas that creates corrosion risk in the off-gas system piping, while the sulfate and phosphate in the fluoride double salts kogarkoite and natrophosphate can be detrimental to glass waste loading. Fluoride salts are sparingly soluble, with solubilities ranging from approximately 40 to 130 kg per kL of pure water, and the dissolution kinetics of the three fluoride salts are not well known. Unexpected delays in a tank dissolution process could be encountered as a result of the lack of information about dissolution rates. In addition, if the double salts show transient non-stoichiometric dissolution of fluoride versus phosphate or sulfate, unexpectedly high concentrations of one of these other constituents could be produced. Washington River Protection Solutions authorized Pacific Northwest National Laboratory to collect the available data for fluoride salt dissolution rate, provide a scoping estimate of dissolution time if possible, and identify gaps in the understanding and predictive capability for estimating dissolution time. Open literature and Hanford reports were reviewed to document, understand, and (where possible) evaluate limitations on fluoride salt equilibria and dissolution kinetics, including both mass transport and surface reaction rate. Scoping estimates of dissolution time were made for mass-transfer-controlled dissolution of spherical particles of fluoride salts suspended in liquid. This is not the only potential governing mechanism; dissolution could be substantially slower if the surface reaction rate (the rate of release of ions from the surface) is the controlling mechanism. When the minimum amount of water for complete dissolution is used and the slip velocity between the liquid and suspended particles is less than or equal to the terminal settling velocity, the estimated mass-transfer rates allow 0.1 mm particles of fluoride salt to dissolve in minutes at 25 °C in water containing no other dissolved salts. Much larger solids, such as the 6-mm chunks that have been seen in heels, could take a few hours to more than a week to dissolve. The actual dissolution times will depend strongly on the actual slip velocity, the extent of particle suspension, constraint by surface reaction rates, the ratio of solvent to solid, and the presence of common ions that shift the solubility equilibria to restrict dissolution of fluoride salts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Hα Dots Survey. II. A Second List of Faint Emission-line Objects

We present the second catalog of serendipitously discovered compact extragalactic emission-line sources—Hα Dots. These objects have been discovered in searches of moderately deep narrow-band images acquired for the ALFALFA Hα project. In addition to cataloging 119 new Hα Dots, we also present follow-up spectral data for the full sample. These spectra allow us to confirm the nature of these objects as true extragalactic emission-line objects, to classify them in terms of activity type (star-forming or AGN), and to identify the emission line via which they were discovered. We tabulate photometric and spectroscopic data for the all objects, and we present an overview of the properties of the full Hα Dot sample. The Hα Dots represent a broad range of star-forming and active galaxies detected via several different emission lines over a wide range of redshifts. The sample includes Hα-detected blue compact dwarf galaxies at low redshift, [O iii]-detected Seyfert 2 and Green Pea-like galaxies at intermediate redshifts, and QSOs detected via one of several UV emission lines, including Lyα. Despite the heterogeneous appearance of the resulting catalog of objects, we show that our selection method leads to well-defined samples of specific classes of emission-line objects with properties that allow for statistical studies of each class.

79 ASTRONOMY AND ASTROPHYSICS↗

A high-temperature mixed potential CO gas sensor for in situ combustion control

An in situ, accurate and robust sensor that can sustain a high temperature of above 1000 °C is needed for on-site combustion monitoring because it can give real-time and local data to the control system to adjust the overall combustion efficiency. In this work, we find that nickel oxide (NiO) is a promising sensing material for CO which is a direct indicator of the status of the combustion process of a power plant. Under the conditions of 0.5–3% O 2 and 1000 °C, the fabricated yttrium-stabilized zirconia (YSZ)-based mixed potential sensor using porous NiO demonstrates good sensitivity to CO, showing a signal as high as 36 mV to 1000 ppm CO. The effects of gas transport, structure and geometry of the NiO electrode on the sensing performance are studied. Results show that fast gas transport is much beneficial to improved sensitivity. NiO having a porous structure is much more sensitive to CO than that having a dense structure. But the t90 (time to achieve 90% final signal magnitude) of the former is much longer due to slower gas diffusion inside the pores. It's worth noting that the NiO sensor exhibits a positive relationship with the CO content, opposite to other reported results of mixed potential sensors to detect CO. We find that this might be due to the electrochemical reduction, instead of oxidation of CO during the interaction with NiO at 1000 °C. Selectivity tests on how CO 2 , CH 4 and steam affect CO sensing are also demonstrated. NiO is insensitive to even 10% CO 2 . CH 4 does not shift the average value of the CO sensing response. However, it makes the sensing signal fluctuate more intensively. 2% steam exerts a great influence on NiO sensitivity to CO: it magnifies the sensitivity of the porous NiO electrode to a low CO range of 0–100 ppm, but inhibits its sensitivity to a CO range of 100 ppm to 1000 ppm. Lastly, an 11 day stability test demonstrates the promising stability property of the proposed NiO-based YSZ sensor.

20 FOSSIL-FUELED POWER PLANTS↗

Update of Emission Factors of Greenhouse Gases and Criteria Air Pollutants, and Generation Efficiencies of the U.S. Electricity Generation Sector

The last decade has seen a steady evolution of the electricity generation sector. Fuels used for electricity generation have shifted from coal to cleaner energy sources such as natural gas and renewables including solar, wind, and other renewable sources. The share of U.S. electricity generated from coal decreased from 45% in 2010 to 24% in 2019, and is expected to decrease further to 13% by 2050. The conversion efficiency of electricity generation has also increased gradually for fuels such as natural gas due as less-efficient old generators are retired and more-efficient generators replace them. These changes in the electricity generation industry are likely to cause changes in the emissions from power generation units. Emission factors of greenhouse gases (GHG) including CO 2 , CH 4 , and N 2 O, and criteria air pollutants (CAPs) including CO, NO x , PM 10 , PM 2.5 , and SO x , from power plants are important parameters for estimating life-cycle emissions associated with vehicle electrification, energy systems, and the production of materials and chemicals. The electricity generation technologies and associated emission factors in the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model need to be updated to reflect recent developments in the electricity generation sector. The most recent update of the electricity generation emission factors in GREET adopted a mixed method. The emission factors of CH 4 , N 2 O, NO x , and SOx were estimated using a “topdown” approach by dividing the total emissions by the total net electricity generation, because emission data of these pollutants are readily available in the Emissions & Generation Resource Integrated Database (eGRID). For other CAPs such as CO, VOC, PM 10 , and PM 2.5 , emission data were not reported in eGRID. A “bottom-up” method was used to estimate the emission factors for these pollutants by considering generic uncontrolled emission factors and the pollutant removal efficiencies of emission control technologies adopted in the electricity generation sector. However, the uncontrolled emission factors and the emission removal efficiencies of various emission control technologies considered in the 2012 study came from the legacy AP-42 emission factors, and may not reflect the actual emission performances of the electricity generation sector of today. To leverage new data that recently became available, especially emission data measured from continuous emission monitoring systems (CEMS), we developed a new “top-down” approach to estimate efficiencies and GHG and CAP emission factors for electricity generation from combustion of individual fuel types by individual combustion technologies on the basis of power-generation data from U.S. Energy Information Administration’s (EIA’s) form EIA-923, and plant emission data from Environmental Protection Agency’s (EPA’s) Clean Air Markets Division (CAMD) dataset and National Emissions Inventory (NEI) dataset. Detailed discussion of the method and data used in this study can be found in Section 2.1. With this topdown approach, we aim to improve the estimates of energy efficiencies and emission factors for power plants using a more consistent methodology, and to update the emission factors, generation efficiencies, and generation technologies mixes in GREET to reflect recent technology advancements in the electricity generation sector.

20 FOSSIL-FUELED POWER PLANTS↗

Grid-Integrated Production of Fischer-Tropsch Synfuels from Nuclear Power

Idaho National Laboratory (INL) investigates the relative economic profitability of an integrated energy system (IES) coupling an NPP with a synfuel production process at selected case study locations across the United States. In the synfuel IES, a high-temperature steam electrolysis (HTSE) plant is thermally and electrically coupled with an NPP to produce zero-carbon hydrogen. The synthetic fuel is produced from this H 2 combined with a CO 2 supply using the reverse water gas shift process followed by the Fischer-Tropsch (FT) reaction. This analysis considers a system in which the CO 2 is sourced from regional CO 2 emitters via the construction and operation of pipeline-based CO 2 supply networks. Locating the FT plant at the same site as the NPP and HTSE plants enables the NPP to provide zero-carbon heat and power to the HTSE plant and zero-carbon power to the FT plant as well as avoid the requirement for long-distance H 2 product transport from the HTSE plant to the FT plant. Hydrogen storage is used to enable the NPP to dispatch power to the electrical grid (instead of the HTSE plant) when grid demand increases, thus enabling the FT plant to continue to operate in a steady-state production mode. The ability to cease hydrogen production for several hours within each day enables the NPP to provide power to the grid to balance the electricity market during peak periods and maximize revenues for the nuclear synfuel IES. The FT process design considered has a 99% carbon conversion efficiency. The use of nuclear energy and nuclear energy-derived hydrogen enables synfuel production to achieve this high level of carbon utilization. Additionally, the life-cycle carbon emissions of the nuclear-based synfuel production process are very low, with WTW emissions of approximately 25 gCO 2 e/MJ, including steam credits (generated from FT process excess heat), and approximately 7 gCO 2 e/MJ, if steam credits are excluded. This compares favorably with the WTW emissions of 90.5 gCO 2 e/MJ for a compression-ignition, direct injection (CIDI) vehicle with a fuel economy of 31.6 miles per gallon gasoline equivalent (MPGGE), using low-sulfur diesel produced using conventional petroleum production and refining processes. Several NPPs in various regions of the U.S. are considered as case study analyses. Supply locations and transportation via pipeline of the CO 2 feedstock to the NPP site are analyzed through the National Energy Technology Laboratory (NETL) CO 2 Transport Cost model. The team finds that the amount of CO 2 generated by different sectors is sufficient for the synfuel production process at all locations considered. The CO 2 transportation costs are functions of the distance of the source to the NPP location, the CO 2 capture cost at the source, and the quantity of CO 2 transported. Historical electricity prices for the NPP case study locations are collected and analyzed. Monthly average prices, price range, and duration of negative-price periods vary among these locations. For each location, an auto-regressive moving average (ARMA) model is trained on historical electricity price data. ARMA validation is done to ensure the synthetic price distributions represent one of historical prices with high fidelity. Synthetic time series from these ARMA models are used in a coupled dispatch and system optimization in the Holistic Energy Resource Optimization Network (HERON) to compute the differential net present value (NPV) of the IES. The team finds that this econometric is positive, ranging from $14M–1.3bn (2020) depending on the location. The optimal synfuel IES configuration to obtain this increase in NPV often maximizes the size of the synfuel production process with regards to the size of the NPP. However, the team shows that the NPP still plays a stabilizing role for the grid: In periods of high prices and high loads, more electricity from the NPP is sent to the grid. A high variability of electricity prices and extreme maximum prices tend to drive up electricity production. While it requires significant investment, the synfuel IES could increase the economic profitability for the existing fleet of LWRs across the country while still maintaining the grid stabilizer role of NPPs. During its lifetime, the main costs for the nuclear synfuel IES are the carbon feedstock transportation costs, followed by the capital expenses (CAPEX) and operation and maintenance (O&M) costs while the revenue comes first from the IRA H 2 production tax credit (PTC) and then from the sales of synfuel products. The profitability of the synfuel IES is most sensitive to the value of the hydrogen PTC and the synfuel products as well as the cost of the carbon feedstock, highlighting the importance of governmental incentives regarding hydrogen, carbon emissions, and synfuel in driving the deployment of future nuclear synfuel IESs.

08 HYDROGEN↗

Advanced modeling and simulation of research reactors using dynamic mode decomposition

Full text of publication follows. Due to the ever-increasing safety requirements, the current trend of nuclear reactor analysis is shifting towards high-fidelity multi-physics models, which have a very high computational cost and modelling complexity. As the cost of even a single model run makes it impossible to analyse the behaviour and performance of these models on large-scale commercial plants, it has become even more significant to provide suitable benchmarks to validate and test them extensively. In this sense, research reactors offer a promising solution for the initial validation of high-fidelity models, as they are significantly smaller than commercial reactors and their characteristics are well known. In particular, the reactors of the TRIGA family have been used to assess and validate models and methods for Generation-IV designs, as they have some similar features (such as the dominance of natural convection as cooling mechanism and the difficulties in performing sub-channel analysis using standard codes). Still, the computational requirements of high-fidelity models make them unsuitable for real-time analysis, even following their assessment on research reactors. In this sense, Model Order Reduction (MOR) techniques give an additional strategy to reduce the computational cost of high-fidelity models (whilst preserving sufficient accuracy). In particular, this work focuses on Dynamic Mode Decomposition (DMD), a non-intrusive MOR technique that aims at representing models with explicit temporal dynamics by extracting the time-varying characteristics and the governing structures based only on a set of available data, thus without needing any underlying knowledge of the governing equations. In addition, DMD also computes a low-dimensional surrogate of the dynamic matrix of the system, making it suited for stability analysis and real-time evaluations. This work focuses on the application and validation of the DMD method on the Computational Fluid-Dynamics (CFD) model TRIGA Mark II reactor, also discussing in detail the potentiality of this algorithm as an advanced modelling tool for nuclear reactor analysis. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Harmonising the land-use flux estimates of global models and national inventories for 2000–2020

As the focus of climate policy shifts from pledges to implementation, there is a growing need to track progress on climate change mitigation at the country level, particularly for the land-use sector. Despite new tools and models providing unprecedented monitoring opportunities, striking differences remain in estimations of anthropogenic land-use CO 2 fluxes between, on the one hand, the national greenhouse gas inventories (NGHGIs) used to assess compliance with national climate targets under the Paris Agreement and, on the other hand, the Global Carbon Budget and Intergovernmental Panel on Climate Change (IPCC) assessment reports, both based on global bookkeeping models (BMs). Recent studies have shown that these differences are mainly due to inconsistent definitions of anthropogenic CO 2 fluxes in managed forests. Countries assume larger areas of forest to be managed than BMs do, due to a broader definition of managed land in NGHGIs. Additionally, the fraction of the land sink caused by indirect effects of human-induced environmental change (e.g. fertilisation effect on vegetation growth due to increased atmospheric CO 2 concentration) on managed lands is treated as non-anthropogenic by BMs but as anthropogenic in most NGHGIs. We implement an approach that adds the CO 2 sink caused by environmental change in countries' managed forests (estimated by 16 dynamic global vegetation models, DGVMs) to the land-use fluxes from three BMs. This sum is conceptually more comparable to NGHGIs and is thus expected to be quantitatively more similar. Our analysis uses updated and more comprehensive data from NGHGIs than previous studies and provides model results at a greater level of disaggregation in terms of regions, countries and land categories (i.e. forest land, deforestation, organic soils, other land uses). Our results confirm a large difference (6.7 GtCO 2 yr —1 ) in global land-use CO 2 fluxes between the ensemble mean of the BMs, which estimate a source of 4.8 GtCO 2 yr —1 for the period 2000–2020, and NGHGIs, which estimate a sink of —1.9 GtCO 2 yr —1 in the same period. Most of the gap is found on forest land (3.5 GtCO 2 yr —1 ), with differences also for deforestation (2.4 GtCO 2 yr —1 ), for fluxes from other land uses (1.0 GtCO 2 yr —1 ) and to a lesser extent for fluxes from organic soils (0.2 GtCO 2 yr —1 ). By adding the DGVM ensemble mean sink arising from environmental change in managed forests (—6.4 GtCO 2 yr —1 ) to BM estimates, the gap between BMs and NGHGIs becomes substantially smaller both globally (residual gap: 0.3 GtCO 2 yr —1 ) and in most regions and countries. However, some discrepancies remain and deserve further investigation. For example, the BMs generally provide higher emissions from deforestation than NGHGIs and, when adjusted with the sink in managed forests estimated by DGVMs, yield a sink that is often greater than NGHGIs. In summary, this study provides a blueprint for harmonising the estimations of anthropogenic land-use fluxes, allowing for detailed comparisons between global models and national inventories at global, regional and country levels. This is crucial to increase confidence in land-use emissions estimates, support investments in land-based mitigation strategies and assess the countries' collective progress under the Global Stocktake of the Paris Agreement.

54 ENVIRONMENTAL SCIENCES↗

Impact of Harvest on Switchgrass Leaf Microbial Communities

Switchgrass is a promising feedstock for biofuel production, with potential for leveraging its native microbial community to increase productivity and resilience to environmental stress. Here, we characterized the bacterial, archaeal and fungal diversity of the leaf microbial community associated with four switchgrass (Panicum virgatum) genotypes, subjected to two harvest treatments (annual harvest and unharvested control), and two fertilization levels (fertilized and unfertilized control), based on 16S rRNA gene and internal transcribed spacer (ITS) region amplicon sequencing. Leaf surface and leaf endosphere bacterial communities were significantly different with Alphaproteobacteria enriched in the leaf surface and Gammaproteobacteria and Bacilli enriched in the leaf endosphere. Harvest treatment significantly shifted presence/absence and abundances of bacterial and fungal leaf surface community members: Gammaproteobacteria were significantly enriched in harvested and Alphaproteobacteria were significantly enriched in unharvested leaf surface communities. These shifts were most prominent in the upland genotype DAC where the leaf surface showed the highest enrichment of Gammaproteobacteria, including taxa with 100% identity to those previously shown to have phytopathogenic function. Fertilization did not have any significant impact on bacterial or fungal communities. We also identified bacterial and fungal taxa present in both the leaf surface and leaf endosphere across all genotypes and treatments. These core taxa were dominated by Methylobacterium, Enterobacteriaceae, and Curtobacterium, in addition to Aureobasidium, Cladosporium, Alternaria and Dothideales. Local core leaf bacterial and fungal taxa represent promising targets for plant microbe engineering and manipulation across various genotypes and harvest treatments. Our study showcases, for the first time, the significant impact that harvest treatment can have on bacterial and fungal taxa inhabiting switchgrass leaves and the need to include this factor in future plant microbial community studies.

59 BASIC BIOLOGICAL SCIENCES↗

Global spatially explicit carbon emissions from land-use change over the past six decades (1961–2020)

Land-use change (LUC) is a major source of global anthropogenic carbon emissions that contribute to climate change. However, current estimates of LUC-induced emissions vary widely with differences in data and models, making it challenging to identify and manage emissions hotspots by location and LUC activity. Here, we estimated spatially explicit carbon fluxes associated with global major gross land-use transitions based on a new bookkeeping model (i.e., LUCE). Between 1961 and 2020, LUC induced 215 and 142 Pg C of global carbon emissions and removals, respectively, resulting in average net emissions (E LUC ) of 1.21 Pg C year −1 . Latin America, Southeast Asia, and Sub-Saharan Africa dominated global E LUC with 69% of 60-year cumulative emissions, or about 86% between 2001 and 2020. Forest-related LUC activities (e.g., deforestation, reforestation) contributed largely to both regional and global carbon fluxes. Our findings shed new light on identifying LUC-induced emissions hotspots and managing land for climate mitigation and conservation.

bookkeeping model↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

First measurements of N -subjettiness in central Pb-Pb collisions at $\sqrt{s{NN}}$= 2.76 TeV

The ALICE Collaboration reports the first fully-corrected measurements of the N-subjettiness observable for track-based jets in heavy-ion collisions. This study is performed using data recorded in pp and Pb-Pb collisions at centre-of-mass energies of $\sqrt{s}$= 7 TeV and $\sqrt{s{NN}}$ = 2.76 TeV, respectively. In particular the ratio of 2-subjettiness to 1-subjettiness, τ 2 /τ 1 , which is sensitive to the rate of two-pronged jet substructure, is presented. Energy loss of jets traversing the strongly interacting medium in heavy-ion collisions is expected to change the rate of two-pronged substructure relative to vacuum. The results are presented for jets with a resolution parameter of R = 0.4 and charged jet transverse momentum of 40 ≤ pτ, jet ≤ 60 GeV/c, which constitute a larger jet resolution and lower jet transverse momentum interval than previous measurements in heavy-ion collisions. This has been achieved by utilising a semi-inclusive hadron-jet coincidence technique to suppress the larger jet combinatorial background in this kinematic region. No significant modification of the τ 2 /τ 1 observable for track-based jets in Pb-Pb collisions is observed relative to vacuum PYTHIA6 and PYTHIA8 references at the same collision energy. The measurements of τ 2 /τ 1 , together with the splitting aperture angle ΔR, are also performed in pp collisions at $\sqrt{s}$ = 7 TeV for inclusive jets. These results are compared with PYTHIA calculations at $\sqrt{s}$ = 7 TeV, in order to validate the model as a vacuum reference for the Pb-Pb centre-of-mass energy. The PYTHIA references for τ 2 /τ 1 are shifted to larger values compared to the measurement in pp collisions. This hints at a reduction in the rate of two-pronged jets in Pb-Pb collisions compared to pp collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Examining the effects of chemical cleaning, leaching, and partial dissolution on zinc and cadmium isotope fractionation in marine carbonates

The application of zinc (Zn) and cadmium (Cd) isotopes as palaeo-proxies in carbonate sediment is rapidly expanding due to their potential for tracing changes in biological productivity in the modern and past oceans. However, there are limited investigations into the chemical cleaning methods required to produce the most consistent and accurate data for these novel isotope systems. This could impact their use as palaeo-proxies to reconstruct ocean-atmosphere-climate interactions throughout Earth's history. To address this concern and expand the utility of the Zn and Cd stable isotope systems as palaeo-productivity tracers, the performance of two standard chemical cleaning protocols for acquiring robust and reliable Zn and Cd isotope datasets were assessed. These include (i) the Cd-cleaning method that uses a reductive step to selectively leach contaminating secondary iron (Fe)-manganese (Mn) (oxyhydr)oxide coatings from the carbonate surface, and an oxidative step that is used to remove post-depositional organic matter and sulphide precipitates; and (ii) the magnesium/calcium cleaning protocol that includes an oxidative step only, leaving secondary Fesingle bondMn (oxyhydr)oxide coatings largely intact. Well-preserved Holocene-, and Mesozoic-aged carbonate sediments were used to test the reliability of these two chemical cleaning methods. The Holocene samples comprised not only aliquots of bulk sediment, but also individual species of planktic and benthic foraminifera. Our results show that the best practice chemical cleaning method for retrieving consistent and accurate Zn and Cd isotope, and Zn/Ca and Cd/Ca datasets for carbonate sediments, requires both reductive and oxidative cleaning following the Cd-cleaning method. This differs from most methodological approaches applied to date that remove the reductive step from the chemical cleaning protocol and apply an oxidative step only, or no chemical cleaning at all. Inclusion of the reductive step in the chemical cleaning method typically shifts δ 66 Zn by ~0.1‰ lower and δ 114 Cd by 0.3‰ higher in the solid phase, while Zn/Ca and Cd/Ca typically decrease 2-fold. The benthic foraminifera, C. wuellerstorfi, that live in ocean bottom waters where the seawater Zn and Cd isotope composition is homogeneous display evidence of Zn and Cd isotope fractionation between seawater and carbonate on the order of 0.08 ± 0.08‰ (2SE, n = 4) and -0.25 ± 0.13‰ (2SE, n = 4), respectively, in agreement with experimental constraints. Furthermore, evidence of Zn isotope fractionation effects are recorded in a naturally-dissolved carbonate sediment, together with laboratory-controlled carbonate dissolution experiments. Based on these results, we recommend the Cd-cleaning method and the application of Zn and Cd isotope fractionation factors to accurately reconstruct past seawater Zn and Cd isotope compositions from carbonate sediments.

58 GEOSCIENCES↗

Hyaloscypha finlandica Metabolome Repository

This repository provides the curated data tables, manuscript figure and table exports, dependency records, and workflow scripts supporting an integrated comparative genomics and untargeted LC-MS/MS metabolomics analysis of Hyaloscypha finlandica strain PMI 746, a root-associated dark septate endophyte of poplar. The repository includes genome-mining summaries from antiSMASH, FunBGCeX, BGC-Prophet, and BiG-SCAPE; processed metabolomics inputs; metabolite annotation evidence; statistical outputs; and publication-facing figures and tables. Raw LC-MS/MS spectra, full genome/protein downloads, and large generated tool outputs are referenced through public archive/accession records and are not stored in Git.

59 BASIC BIOLOGICAL SCIENCES↗

Transition Core Planning and Safety Analyses in Support of LEU Fuel Conversion of the University of Missouri Research Reactor (MURR)

The University of Missouri Research Reactor (MURR®) is one of six U.S. High Performance Research Reactors (USHPRR), including one critical facility, that is working with the National Nuclear Security Administration (NNSA) Office of Material Management and Minimization (M3) Reactor Conversion Program to convert from highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel. The M3 Reactor Conversion USHPRR Project objectives include the development of LEU fuel element designs that will ensure safe reactor operations and to maintain the existing experimental performance of each facility. The work is being conducted through many inter-related activities being completed by four Project Pillars: Fuel Qualification (FQ), Fuel Fabrication (FF), Reactor Conversion (RC), and Cross Cutting (CC). A new type of LEU fuel based on an alloy of uranium-10 wt% molybdenum (U-10Mo) is expected to allow the conversion of those USHPRR, like MURR, requiring higher density fuels. The very-high-density LEU U-10Mo monolithic fuel is currently undergoing irradiation testing and post-irradiation examination under a planned and documented fuel qualification effort. The FQ Pillar will document fuel property and fuel performance data and qualify the fuel for use in these reactors. The FF Pillar is fabricating fuel for ongoing and future irradiation tests, as well as conducting fabrication demonstrations to validate or update preliminary fabrication assumptions. The FF Pillar is also working to develop and install commercial manufacturing capacity with the U-10Mo monolithic fuel to produce prototypic fuel. Working with the RC Pillar at Argonne, MURR has progressed through a preliminary fuel element design using preliminary data for the proposed monolithic alloy of U-10Mo. Analyses were completed in previous work that found for typical equilibrium operations with the preliminary LEU fuel element design, in conjunction with a power uprate to 12 MW and appropriate changes to the MURR Limiting safety system settings (LSSS), MURR will have adequate margins to safety for steady-state operations and postulated transient accidents and will have experimental performance in key locations that meets or exceeds current operations with HEU fuel. The purpose of this work is to develop a sequence of transition cycles that will enable MURR to transition from operation with the reactor core loaded with fresh LEU fuel elements only to typical equilibrium operations with mixed-burnup cores following conversion while meeting operational requirements on safety and experimental performance. It is expected that the use of fresh LEU fuel at conversion and subsequent low burnup of the LEU fuel elements that will initially be available for use following conversion will result in critical control blade positions that will substantially change the axial power distribution in the core and the neutron flux available in key experimental locations relative to equilibrium LEU operations. Given the constraints of MURR safety margins, operational practices, and production and research, a novel method has been developed to identify a transition sequence that minimizes the time MURR operates atypically compared to the current prototypic cycles using HEU fuel. The proposed transition sequence moves quickly to the same sort of equilibrium cycles for the LEU fuel that have already been evaluated in documented preliminary safety analyses. Although shifting the neutron flux peak to the lower half of the core during initial cycles with LEU at 12 MW reduces the experiment performance in some key locations relative to current HEU operations at 10 MW, all LEU cores provide an average performance that meets or exceeds that of HEU. An LEU cycle is reached that meets or exceeds the level of experimental performance predicted for current HEU and equilibrium LEU operations in more than 450 key locations identified by a reactor specialist at MURR by the 23rd cycle following conversion and that afterwards will enable MURR to consistently meet its experimental performance requirements. The proposed transition sequence only requires the fabrication of 34 fresh LEU elements in the first year of operation and does not exceed the anticipated availability of fresh elements that can be produced by the fuel fabricator. By the third year after conversion, 22 fresh LEU elements will be required each year, which is the same as expected for equilibrium LEU operations and the same as current operations with HEU fuel. The proposed transition sequence thus combines a relatively short time period before equilibrium burnup is achieved, a temporary increase of fuel elements needed annually relative to typical operations that are within the production capabilities of the fuel fabricator, and demonstrates comparable experimental performance of the LEU cores relative to current HEU operations. Further measures may be taken to reduce any initial experimental performance penalty even further, where possible, by repositioning certain experiments to leverage the increased performance in the lower axial experimental positions in the initial cycles following conversion or leaving the experiments in the irradiation facilities longer in order to achieve the required neutron fluence. This analysis may require refinement depending on the experimental facilities in use at the time of conversion. Nonetheless, the results presented here, including the experimental performance, core burnup, and critical control blade positions throughout the transition cycles, show that the proposed transition cycle fuel management patterns are consistent with what is expected and desired for MURR operation with LEU U-10Mo fuel. Detailed core power distributions from the neutronics models were also used to evaluate safety margins during steady-state operations for the selected transition cycles and the equilibrium LEU core. It is shown that there are adequate safety margins for both steady-state operations and postulated accident scenarios. For the steady-state operations with the preliminary LEU fuel element design the analysis predicts at least 2.49 MW margin to the onset of flow instability at the LSSS power of 15 MW. Considering the LSSS power is 125% of full license power, the margin to OFI is sufficient. In addition, the critical heat flux ratio at LSSS power is well above the requirement of CHFR > 2.0 from NUREG-1537 for all considered cases. For postulated transient accidents, the minimum margin to the fuel temperature safety limit is at least 109 °C. In summary, the proposed sequence of core loadings for MURR operations following conversion to LEU fuel and a power uprate to 12 MW provides sufficient safety margins for both steady-state operations and postulated transient accidents during a proposed sequence of transition cycles to equilibrium operations. Analysis has shown that there are some local experimental performance penalties during the initial cycles. Although there are local shifts in the experimental performance, on average all LEU cores at 12 MW have equal or higher performance than HEU at 10 MW. Temporary adjustments are being planned that will produce suitable experimental performance during these cycles. The results indicate that for the equilibrium LEU core the experimental performance exceeds that of current HEU operations in all key locations while also demonstrating sufficient safety margins.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗