Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “currents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Search for flavor changing neutral current interactions of the top quark in final states with a photon and additional jets in proton-proton collisions at s = 13 TeV

A search for the production of a top quark in association with a photon and additional jets via flavor changing neutral current interactions is presented. The analysis uses proton-proton collision data recorded by the CMS detector at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 138 fb - 1 . The search is performed by looking for processes where a single top quark is produced in association with a photon, or a pair of top quarks where one of the top quarks decays into a photon and an up or charm quark. Events with an electron or a muon, a photon, one or more jets, and missing transverse momentum are selected. Multivariate analysis techniques are used to discriminate signal and standard model background processes. No significant deviation is observed over the predicted background. Observed (expected) upper limits are set on the branching fractions of top quark decays: B ( t → u γ ) < 0.95 × 10 - 5 ( 1.20 × 10 - 5 ) and B ( t → c γ ) < 1.51 × 10 - 5 ( 1.54 × 10 - 5 ) at 95% confidence level, assuming a single nonzero coupling at a time. The obtained limit for B ( t → u γ ) is similar to the current best limit, while the limit for B ( t → c γ ) is significantly tighter than previous results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bidirectional Three-phase Current Source Converter based Buck-boost AC/DC System using Bidirectional Switches

The 1.2 kV 4H-SiC BiDirectional Field Effect Transistor (BiDFET) is the first monolithic SiC bidirectional switch, which offers a lower voltage drop and semiconductor devices count alternative to the reverse-voltage-blocking (RB) switch used in the current-source converters (CSC). The bidirectional switch based CSC also allows DC-link current reversal for bidirectional power flow and provides multiple system-level benefits in a buck-boost AC/DC system consisting of buck-type DC/DC converter and CSC. This paper discusses the selection of buck converter duty cycle and CSC modulation index for the system’s buck-boost operation with a wide variation in DC voltage. CSC modulation schemes categorized based on the number of hard-turn-on transitions per switching cycle are also analyzed along with the three-step and four-step commutation schemes that are essential for the CSC commutation cells. Finally, the different schemes are evaluated and compared through the experimental results of a 10 kW, 480 VRMS, LL/ (400 − 800) V AC/DC system.

Bidirectional switches, four-quadrant switches, cu↗

Suppressing Screening-Current-Induced Strain in a 72-mm-Bore REBCO Insert for a 20-T Magnet: A Numerical Study

Rare-earth barium copper oxide (REBCO) high-temperature superconducting (HTS) magnets are considered a game changer for the capability of generating magnetic fields exceeding 20 T at or above liquid helium temperature, combined with the potential for substantially reduced manufacturing and operational costs. Princeton Plasma Physics Laboratory is dedicated to developing large-bore high-field superconducting magnet systems to support forefront physics research. Here, our current project focuses on a φ72-mm cold-bore REBCO insert comprising 21 dry-wound double-pancake coils, designed to generate at least 8 T when nested within a 12-T outsert magnet. A significant challenge for high-field REBCO magnets is the time-varying-magnetic-field-induced screening currents (SC) in the REBCO conductors, which can cause localized strain and stress concentrations. This paper presents a numerical study of the SC-induced strain in the REBCO insert magnet, confirming that the SC-induced strain can be substantially suppressed by energizing the REBCO insert before the outsert magnets. We discuss and reveal the mechanism behind this reduction. By applying this strategy, we expect to unleash the potential of the REBCO insert magnet to generate up to 12 T in a 12-T background field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Port Impedance Measurement and Current Injection Response Analysis for PLCs

Programmable Logic Controllers (PLCs) are used to control devices throughout the power system since they have fast control capabilities and can utilize multiple types of communication interfaces. Therefore, studying and mitigating their vulnerabilities to electromagnetic pulse is important for the reliability of PLC operations. Here, in this paper, an effective impedance measurement scheme is proposed and demonstrated for three PLCs to estimate their susceptibility to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Then different parameters of the impedance measurement setup are explored. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulsed Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of the PLC.

42 ENGINEERING↗

Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs . Current and Voltage

The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. It is important to measure and understand the dependence of the neutron production rate on the accelerator current and voltage. In this study we evaluated neutron production with an absolutely calibrated liquid scintillator neutron spectrometer (BTI N-Probe), an absolutely calibrated He-3 detector surrounded by HDPE shells (Detec Nested Neutron Spectrometer, NNS), and two uncalibrated ZnS fast neutron scintillators (EJ-410), for both A3082 and A3083 sealed tubes. Here we also modeled the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental results showed an essentially linear dependence on beam current, as expected. A 3.59 ±0.08 power law dependence on the operating voltage was measured, in effective agreement with the modeled value of 3.5. A series of absolute NNS and N-Probe measurements, matched against MCNP calculations, showed that the A3083 and A3082 tubes provide a maximum neutron yield of 8.2 × 10 8 n/s and 4.7 × 10 8 n/s respectively, with estimated uncertainty of ±10%.We showed, through modeling, that tritium decay is not a significant consideration for tubes, such as these, with lifetimes of less than 10 years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects-Based Monitoring of Geomagnetically-Induced Current Using a Convolutional Neural Network

Geomagnetically-induced current (GIC) due to space weather can flow in the power grid causing undesirable effects such as transformer overheating, misoperation of protection devices, and potential blackouts. It is therefore important to monitor GIC in the power grid to improve online situational awareness and decision-making of system operators during a geomagnetic disturbance. To avoid the costly installation of GIC monitors at transformers’ neutrals, it is desirable to find correlations between GIC and already-monitored parameters. Hence, this work proposed the use of a convolutional neural network (CNN) to compute GIC amplitudes from learned patterns in the time-series data of transformer even harmonic currents. Using an electromagnetic transient program, GIC injection simulations were performed for a modeled Dominion Energy Virginia (DEV) substation with two 504 MVA, 500/230 kV transformers. Data collected from these offline simulations were used to train the CNN to provide online GIC monitoring. Testing the CNN performance involved using real GIC measurements from published literature and from a physical GIC monitor in the DEV area. Finally, the results showed that the proposed method was able to provide GIC readings with a root mean squared error of 1.56 A/phase (equivalent to an average accuracy of 94%) for these real GIC waveforms.

42 ENGINEERING↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗

Thermal Overloading Risk Mitigation With a Semi-Analytical Probabilistic Model on Branch Current

A semi-analytical formulation is presented in this paper for the probability computation of branch current in multiphase systems. The developed formula is derived based on the linear power flow model in rectangular coordinates. The system uncertainty injections can be renewable energy resources or loads and are modeled using a Gaussian mixture model (GMM). The developed formula can be used to compute the line current violation probability as well as integrate into optimal power flow problem as chance-constraint relaxation. Here, the proposed formula is first compared with the Matlab embedded numerical integration function to show its performance. Besides, the semi-analytical formula is validated and compared with the Monte Carlo simulation method using the IEEE 123-bus system, EPRI Ckt5, and Ckt7 systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Analysis and Optimized Modeling of Geomagnetically Induced Currents in Power Transformers

In this project we aim to better understand the effect of geomagnetically induced currents (GIC) on power transformers. Expanding upon our previous work focused on producing a methodology for accuracy-enhanced computation of GIC signatures (i.e., time-domain current magnitude variation for the event duration) from a combination of physics-based and data-driven computational tools, we propose the use of these GIC signatures as inputs for a physically-detailed and optimized model of the power transformer to investigate how GIC determination and transformer modeling influence the evaluation of GIC effects on the transformer operation, as well as in its interaction with the power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Negative Medium-Voltage Direct Current Discharges in Air under Simulated Sub-Atmospheric Pressures for All-Electric Aircraft

The increase in the global temperature due to greenhouse gas emissions is a major concern to the world. To achieve the goal of zero emissions by 2050 in the USA the practical realization of all-electric vehicles, particularly all-electric aircraft (AEA), is important. For the design of electrical power systems (EPSs) in all-electric aircraft, a bipolar medium-voltage direct current (MVDC) system of ±5 kV is being investigated. However, several challenges manifest when using such voltages in a low-pressure environment. One of the main challenges is the partial discharge (PD) behavior of the insulation. It is important to study the PD behavior of the insulation by simulating the aviation environment in the lab. This work aimed to study the partial discharge behavior of air under a negative DC voltage in a needle-to-plane electrode geometry by simulating the aviation pressures in the lab. The partial discharge inception voltage (PDIV) and the breakdown voltage (BDV) show an obvious pressure-dependent variation. Regression analysis was performed to better understand the relationship between the PDIV and pressures. Plots were drawn for the average discharge current at each voltage step until breakdown. This paper’s findings can provide valuable insight into the design of EPS for an AEA. To the best of our knowledge, such a study has not been carried out to date.

air discharge↗

Numerical Modeling of a Two-Stage Ocean Current Turbine

The Equinox Ocean Turbines (EQOT) current energy converter has a unique design with power generation in two small-diameter turbines attached to the tips of a large-diameter passive rotor. This configuration offers some key advantages for capturing ocean currents. With no centrally placed generator, almost no reaction torque is required at the nacelle of the main large-diameter rotor, and the small-diameter tip turbine generators operate at a higher speed and lower torque. The physics that determine the performance and loads on the turbine are also unique. The interactions of the flow field between the two stages and the general architecture of the system cannot be captured with traditional mid-fidelity modeling tools. For design iterations and large sets of load cases, it is important to have mid-fidelity models that can capture the important phenomenon with enough accuracy to identify global trends. This work uses a limited set of high-fidelity computational fluid dynamics (CFD) simulations to help inform the selection of and construction of a custom mid-fidelity model. Mid-fidelity modeling approaches were verified by comparing key turbine performance quantities to those found with the CFD model. Hydrodynamic interactions of the two-stage rotor were identified through high-fidelity CFD modeling. This highlighted the impact of the main rotor tip vortex and wake on the secondary rotor apparent inflow. This results in a relative flow rotation and sharp deficit, that change the optimal secondary rotor rotation speed and adds unsteadiness to the blade loading respectively. Multiple mid-fidelity approaches were evaluated for their ability to capture these effects. A simple approximation of the combined-stage performance based on single-stage BEM provides a reasonable rough prediction, especially near the peak TSR values, with some larger discrepancy at higher TSRs. Predicting the combined-stage performance based on single-stage CFD data improves this prediction across the TSR range. Although the combined-stage modeling in OLAF was not successful in this stage of the project, it showed promise as a mid-fidelity method, assuming the parameters can be tuned to account for the significant differences in time and length scales between the main and secondary rotors. This may be addressed through code changes in future work. A significant finding from the OLAF work was the agreement between the vortex core radius values found independently via a parameter space search and via CFD. The technique of using single-stage secondary rotor BEM, with a custom inflow taken from single-stage main rotor CFD or OLAF, provides an efficient method to capture one-way coupled flow interactions. This method provided generally good predictions of the impact of the flow rotation on the secondary rotor but struggled to accurately predict the peaks of the unsteady load progression. Future work could include some superposition of a tuned main rotor trailing edge viscous wake into the custom inflow to better predict this interaction.

16 TIDAL AND WAVE POWER↗