Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current conservation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Movement Models to Predict Low‐Altitude Flight of Soaring Birds Using Look‐Ahead Environmental Factors

Advances in fine-scale movement modeling of soaring birds can aid efforts to understand and resolve the impacts of anthropogenic activities on such birds. Soaring birds often rely on underlying terrain and low-altitude updrafts to govern their flights at rotor-swept altitudes (≤ 200 m above ground level), which puts them at risk of collision with wind turbines. We developed a data-driven Markov model at 1-s resolution that predicts the fine-scale flight behavior of golden eagles (Aquila chrysaetos) as a function of ecological covariates at the current location as well as those within an eagle's line of sight. We only considered ecological covariates that are readily available in real-time (ground elevation and wind conditions). Latent factors (age, sex, species, behavioral intent, migratory status) were intentionally left out of the model. We calibrated the model using golden eagle telemetry data collected in two different ecoregions of the United States. Given a starting location, the calibrated model simulates multiple stochastic 3D paths to produce a time-explicit and spatially explicit risk map of turbine collisions. We discovered an empirical relation between the rate of change of heading and the orographic updraft conditions within an eagle's line of sight. Our model performed most effectively when predicting predominantly-soaring flights at rotor-swept altitudes during wind conditions in which turbines are likely to be operational. The calibrated model could be used in concert with automated eagle detection and turbine curtailment technologies. Specifically, once an eagle is detected by those systems, our model could then provide accurate predictions of turbines the eagle is likely to interact with in the near term.

17 WIND ENERGY↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Economics of electric vehicle corridor fast charging in the United States

Corridor direct-current fast charging (DCFC) stations enable long-distance electric vehicle travel, yet their economics remain uncertain due to high capital costs, low initial utilization, and exposure to utility demand charges. This study evaluates the long-term economics of corridor DCFC across the United States, incorporating capital and operating expenses-including charging equipment and real-world utility tariffs-alongside modeled station utilization, financial incentives, and ancillary retail revenue. In the Baseline scenario, modeled breakeven costs for corridor DCFC average $\$$0.42/kWh over 20 years, yet fewer than half of stations reach cost parity with gasoline on a per-mile basis. Utilization is the primary driver of cost variation, with low-utilization stations costing roughly six times more per kilowatt-hour than the national average. Excluding stations that fail to reach cost parity reduces National Highway System coverage within 50 miles from 94% to 67%, underscoring the trade-off between market-driven deployment and comprehensive network coverage. These results provide guidance for charging providers, utilities, planners, and policymakers seeking to develop and sustain a financially viable national corridor charging network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design, Development and Testing Plan for Energy Efficiency Algorithms Related to Building-Integrated Cooling, Heating, and Power Systems

Building-integrated cooling, heating and power (CHP) systems are more efficient than conventional systems at providing local power and thermal energy, and favorable fuel prices are bound to spur their increased adoption. It is estimated that the total CHP technical potential in the commercial building sector is approximately 76 GW, but only a small fraction of it is actually deployed. Advanced control and monitoring systems that realize the full potential of these CHP systems can transform this capacity into an asset for both the owner and the grid and also accelerate the adoption of these systems in the building sector. However, to realize the full benefit of the CHP systems, we must ensure persistence of energy efficient operations. It has been demonstrated by several studies that as much as 30% of building energy use is wasted. Much of the waste results from the inability to anticipate load variations (design day vs. non-design day operations; diurnal variation of loads), identify improper operation, and efficiently operate, control and maintain building systems. Moreover, many buildings, even those with adequate control infrastructure, lack knowledgeable staff to operate and maintain energy systems. Operators of buildings with CHP systems will constantly need to make tradeoffs (economic dispatch) between onsite power generation and purchasing power, between onsite heat production from distributed generation versus heating/cooling from conventional systems, and different passive and active load management measures. Much of the inefficiency in the current building operations can be eliminated by use of automated performance monitoring (PM), real-time commissioning verification (CxV) and automated fault detection and diagnostic (AFDD) tools. Automation can help system operators make intelligent decisions. Remote and continuous monitoring of system conditions and performance will enable better management and integration of CHP with existing building systems. Continuous PM, real-time CxV and AFDD could alleviate burdens for operations staff, enhance operations and maintenance (O&M), and improve reliability of building and CHP systems. To address the O&M challenges and to provide a means to maximize the rate-of-return of building-integrated CHP systems, the Building Technologies Office (BTO) within the U.S. Department of Energy’s (DOE’s) Office of Energy Efficiency and Renewable Energy (EERE) initiated a project to design, develop, and field test a VOLTTRON™-based supervisory controller and associated open-source algorithms. These algorithms will ensure real-time optimal operation of a building-integrated CHP system, support electric grid reliability, and lead to achieving the goal of a clean, efficient, reliable and affordable next-generation integrated energy systems. This report lists the components for which PM, real-time CxV and AFDD algorithms will be developed, how the algorithms will be tested, and metrics that will be used to validate the algorithms and easy of deployment. Deployment of these algorithms in the field will result in savings reduction in energy consumption of between 10% and 20%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Space Radiation Cancer, Circulatory Disease and CNS Risks for Near Earth Asteroid and Mars Missions: Uncertainty Estimates for Never-Smokers

The uncertainties in estimating the health risks from galactic cosmic rays (GCR) and solar particle events (SPE) are a major limitation to the length of space missions and the evaluation of potential risk mitigation approaches. NASA limits astronaut exposures to a 3% risk of exposure induced cancer death (REID), and protects against uncertainties in risks projections using an assessment of 95% confidence intervals after propagating the error from all model factors (environment and organ exposure, risk coefficients, dose-rate modifiers, and quality factors). Because there are potentially significant late mortality risks from diseases of the circulatory system and central nervous system (CNS) which are less well defined than cancer risks, the cancer REID limit is not necessarily conservative. In this report, we discuss estimates of lifetime risks from space radiation and new estimates of model uncertainties are described. The key updates to the NASA risk projection model are: 1) Revised values for low LET risk coefficients for tissue specific cancer incidence, with incidence rates transported to an average U.S. population to estimate the probability of Risk of Exposure Induced Cancer (REIC) and REID. 2) An analysis of smoking attributable cancer risks for never-smokers that shows significantly reduced lung cancer risk as well as overall cancer risks from radiation compared to risk estimated for the average U.S. population. 3) Derivation of track structure based quality functions depends on particle fluence, charge number, Z and kinetic energy, E. 4) The assignment of a smaller maximum in quality function for leukemia than for solid cancers. 5) The use of the ICRP tissue weights is shown to over-estimate cancer risks from SPEs by a factor of 2 or more. Summing cancer risks for each tissue is recommended as a more accurate approach to estimate SPE cancer risks. 6) Additional considerations on circulatory and CNS disease risks. Our analysis shows that an individual s history of smoking exposure has a larger impact on GCR risk estimates than amounts of radiation shielding or age at exposure (amongst adults). Risks for never-smokers compared to the average U.S. population are estimated to be reduced between 30% and 60% dependent on model assumptions. Lung cancer is the major contributor to the reduction for never-smokers, with additional contributions from circulatory diseases and cancers of the stomach, liver, bladder, oral cavity and esophagus, and leukemia. The relative contribution of CNS risks to the overall space radiation detriment is potentially increased for never-smokers such as most astronauts. Problems in estimating risks for former smokers and the influence of second-hand smoke are discussed. Compared to the LET approximation, the new track structure derived radiation quality functions lead to a reduced risk for relativistic energy particles and increased risks for intermediate energy particles. Revised estimates for the number of safe days in space at solar minimum for heavy shielding conditions are described for never-smokers and the average U.S. population. Results show that missions to near Earth asteroids (NEA) or Mars violate NASA's radiation safety standards with the current levels of uncertainties. Greater improvements in risk estimates for never-smokers are possible, and would be dependent on improved understanding of risk transfer models, and elucidating the role of space radiation on the various stages of disease formation (e.g. initiation, promotion, and progression).

Cucinotta, Francis A.↗

Catalytic Bio-crude Production in a Novel, Short-Contact Time Reactor

RTI has developed a catalytic fast pyrolysis (CFP) process to produce biomass-based hydrocarbon replacement fuels. From a technology perspective, this advanced biofuels process produces liquid transportation fuels that can leverage capital expenditures in the existing petroleum distribution infrastructure. From a business perspective, this technology does not face potential market limitations caused by oxygenate blend limitations for light duty vehicle applications. A promising catalyst has been developed with excellent potential for deoxygenation to produce a hydrocarbon-rich biocrude that is more suitable for upgrading with traditional hydroprocessing technology. The role of the catalyst is to control the chemistry during biomass pyrolysis to produce a biocrude in a single step that has lower oxygen content and is more thermally stable than conventional biomass fast pyrolysis oil. Catalyst properties are optimized to minimize gas and coke production and improve catalytic deoxygenation and biocrude yields. Results from this project have demonstrated that biocrudes from catalytic fast pyrolysis contain <20 wt% oxygen, with the organic fraction as low as 12% oxygen. These oxygen numbers are > 50% lower compared to traditional fast pyrolysis oils. The biocrude produced from our CFP process can be upgraded to gasoline range hydrocarbons. A very conservative approach for upgrading included a preliminary stabilization step followed by a hydroprocessing step. The oxygen content in the upgraded product was decreased by 97% (to less than 3wt %) from the oxygen content of the biocrude sample. Additionally, the acid content was reduced by 99% from the acid content of the biocrude sample. In an optimized integrated process, the CFP step and the hydroprocessing (upgrading) step need to be carefully balanced to maximize the input biomass energy that is recovered in the finished biofuels. Hydrogen utilization and carbon recovery during both catalytic biomass pyrolysis and biocrude upgrading need to be optimized to maximize energy recovery in the finished biofuel. A nominal 1 ton per day (TPD) catalytic biomass pyrolysis system was designed based on the laboratory experimental data. The system was designed to achieve the short residence times (0.5–2 sec) and high heat transfer rates required for maximum liquid biocrude yields while optimizing process integration to maintain catalyst activity by continuous regeneration. The catalytic biomass pyrolysis reactor is a continuously circulating single-loop transport reactor design that is flexible enough to allow sensitivity studies around temperature, residence time, biomass feed rate, and catalyst-to-biomass ratio (i.e., catalyst circulation rate) for process optimization. For a nominal 100 lb/hr feed rate of dry biomass, the products include ~25 lb/hr char and coke, ~20 lb/hr permanent gases, and ~55 lb/hr condensable vapors. Pyrolysis temperatures are 350–600°C, and the system is operated close to ambient pressure. Production of the catalyst developed within the project was scaled up to provide enough material (200kg) for bench-scale testing. The 1TPD bench-scale unit was fabricated, installed and commissioned with this project. Biocrude samples from wood were produced in this unit with the CFP catalyst with material balance > 90%. The intermediate biocrude yields and chemical composition compare well with previous laboratory results and a hydroprocessing strategy for upgrading the resulting biocrude was developed. The experimental results obtained within this project were used to develop a process model for a 2000 TPD commercial facility. Detailed flow sheets were developed for all major unit operations in the process and provided a basis for an economic analysis to develop capital and operating costs. Estimates of the biofuel production costs were used to develop internal rates of return for the yields and compositions measured for the current state of technology at the end of this project and for the yields anticipated for an optimized (nth plant) scenario as additional process improvements are made.

09 BIOMASS FUELS↗

Plant Water Profiler: A Water Balance and True Cost of Water Calculator for Manufacturing Plants

As the uncertainty of a sustained water supply, regulatory constraints, competition among end users, and public scrutiny increases, a growing number of manufacturing sectors are adapting to current and emerging water-related risks by optimizing productivity and reducing waste. As a step toward increasing water use efficiency and making informed business decisions, corporations must make an effort to understand and track their water demands, losses, and costs associated with each subsystem within their facilities. Manufacturers are often unaware of the “true cost of water” (i.e., the total costs associated with procurement, treatment, and consumption of water, and wastewater disposal), which reduces the visibility of the actual impact of water-saving measures. To help manufacturers account for water procurement and use in manufacturing operations, quantify the true cost of water, and identify potential areas for water and associated energy cost savings, an open access tool—Plant Water Profiler (PWP)—was developed. The tool is based on water mass balance analysis and has been adopted as the core analysis tool for plant water use assessments, Water In-Plant Training (Water INPLT), as part of the US Department of Energy’s Better Plants program. During three pilot INPLTs conducted in 2019 at three manufacturing facilities, the PWP tool allowed users to understand water flows within the facilities and provided additional capabilities to analyze their water use. This paper describes the methodology behind the PWP tool and its implementation through pilot Water INPLT trainings delivered in three manufacturing facilities in the United States. The three case studies demonstrate opportunities to improve water efficiency and reduce associated costs and the challenges encountered in three different manufacturing sectors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant-driven end use load models for demand response and flexibility service participation of residential grid-interactive buildings

As demand response becomes increasingly used as a tool to support improved grid flexibility, it is important to consider that there are many potential types of energy end uses that may be used to support such flexibility. Residential appliances, often accounting for 30 % or more of residential energy use, are a currently untapped source of demand flexibility, particularly when aggregated together across homes. To date there has been very limited analysis of residential appliances for use as grid-interactive loads. As such, this research uses disaggregated energy end use data for 564 households, to model the electricity demand flexibility potential of the use of residential dishwashers, clothes washers, clothes dryers, ovens, and ranges (oven + stovetop) on both weekdays and weekends. This includes both at the building level, as well as aggregated to the grid level, specifically the Midcontinent Independent System Operator (MISO) region. This study was divided into two parts. Part 1 focuses on determining appliance-level loads, and Part 2, which involves aggregation to the grid. Findings suggest that among the studied appliances, clothes dryers provide the greatest demand reduction potential for most times of the day, followed by dishwashers and clothes washers. The maximum potential reduction for clothes dryers is found to be approximately at 11:00 a.m. and this potential sustains throughout most of the daytime period. When considering the willingness of households to participate, based on a survey of households in the Midwest region, clothes dryers still have the most potential for demand reduction. The availability of appliances for load modulation on weekdays and weekends indicates similar load reduction potential for all appliances. Overall, the results of this study suggest that there is an opportunity for shifting appliance usage to optimize grid efficiency and enhance demand response strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental and Numerical Study on the Effect of Nitric Oxide on Autoignition and Knock in a Direct-Injection Spark-Ignition Engine

We report Nitric Oxide (NO) can significantly influence the autoignition reactivity and this can affect knock limits in conventional stoichiometric SI engines. Previous studies also revealed that the role of NO changes with fuel type. Fuels with high RON (Research Octane Number) and high Octane Sensitivity (S = RON – MON (Motor Octane Number)) exhibited monotonically retarding knocklimited combustion phasing (KL-CA50) with increasing NO. In contrast, for a high-RON, low-S fuel, the addition of NO initially resulted in a strongly retarded KL-CA50 but beyond the certain amount of NO, KL-CA50 advanced again. The current study focuses on same high-RON, low-S Alkylate fuel to better understand the mechanisms responsible for the reversal in the effect of NO on KLCA50 beyond a certain amount of NO. Experiments were conducted to measure the responses of KL-CA50 and trace-autoignition CA50, the latter being indicative of CA50 at which end-gas autoignition starts to become measurable from the apparent heat-release rate. Chemical-kinetics simulations were conducted to reveal the role of NO for end-gas autoignition, with a specific focus on sequential autoignition in a thermally stratified end-gas. The simulation results reveal that the magnitude of low-temperature heat release (LTHR) generally increases with NO. However, the relative importance of NO for enhancing LTHR diminishes when the LTHR inherent to a fuel’s chemistry is strong, such as at lower temperatures in a thermal boundary layer. This rendered more uniform LTHR within a hypothetical thermal boundary and led to a more sequential (i.e. slower) autoignition event. It was also revealed that a change in compression ratio influences the importance of intermediate-temperature heat release (ITHR) due to changes of the temperature-pressure history of the end-gas. Together with the condition where end-gas autoignition occurs more sequentially, the shorter time spent in LTHR and ITHR regime can counter the increase in autoignition reactivity at high NO levels and allow KLCA50 to advance

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probabilistic Modeling of Commercial Building Occupancy Patterns Using Location-Based Map Data: Preprint

Considering occupancy patterns is crucial to simulate buildings' energy use. Current energy models use inputs that simplify the actual diversity in occupancy into static occupancy patterns and are not able to represent the numerous variations in occupancy patterns between buildings and across different locations. Recently, inferring occupancy schedules from metered electricity consumption data was used to model occupancy in commercial buildings. However, the translation from metered data to occupancy schedules requires many assumptions that might not capture the reality, and the process is hindered by the availability of data from advanced metering infrastructure. With the development of information technologies, occupancy modeling should not be limited to traditional approaches. The prevalence of social networks and location services with real-time user feedback provides publicly accessible data via Maps Application Programming Interfaces (APIs) such as Google Maps, SafeGraph, Mapbox, Foursquare, etc. This paper presents an automated framework for modeling parametric occupancy patterns using such APIs to calibrate commercial district buildings' energy models. This process includes three main steps: data extraction and processing, parametric schedules generation, and schedules integration. We demonstrated this framework in districts where we used maps API to generate more accurate behavioral patterns for operations and electric vehicle charging events. We used these patterns to determine differences in energy use across key sociodemographic and spatial parameters. The presented method has the potential for worldwide applications. Users can utilize this framework to extract data for selected locations of interest to create more realistic behavioral patterns for commercial facilities across different districts.

building energy modeling↗

Combined Nitrogen and Phosphorous Recovery via Electrochemical Technology Integration into Municipal Wastewater Treatment Plants

This project developed electroN-P, an electrochemical technology for recovering nitrogen and phosphorus as a fertilizer product from anaerobic digester centrate, targeting an advancement from TRL 4 to 6. The reactor was scaled 220× from a 250 mL batch cell to a continuous 4-channel system treating 55 L of wastewater, recovering >80% of phosphorus. Energy consumption under constant-voltage operation was lower than the embedded energy of conventional fertilizers, while constant-current operation produced a cost-competitive product with a smaller reactor footprint. TEA and LCA outcomes were highly sensitive to the magnesium source; alternative magnesium salt configurations projected reduced costs and embedded energy compared to sacrificial rods, but at the expense of significantly longer operation times. The recovered fertilizer performed comparably to diammonium phosphate and triple superphosphate in soil and plant trials. Integrating the technology into a whole-plant model reduced aeration energy by nearly 50%, lowering the levelized cost of water treatment from $0.668/m 3 to $0.648/m 3 . Results support targeting commercialization at smaller (≤1 MGD) facilities with high-strength digester streams. Further investigation into the transport and corrosion kinetics governing sacrificial anode wear is recommended to support continuous, longer-term operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct-DC Power in Buildings: Identifying the Best Applications Today for Tomorrow’s Building Sector

Driven by the increased use of direct current (DC) sources (photovoltaics, battery storage) and DC end-use devices (electronics, solid-state lighting, efficient motors), DC power distribution in buildings and DC microgrids have been proposed as a way to achieve greater efficiency, cost savings, and resiliency in a transitioning building sector. Despite these important benefits, several market and technological barriers inhibit the development of DC distribution, and the market for DC in buildings is still largely in the demonstration phase. Therefore, to jumpstart this technology, a clear path forward must emerge at this early stage of deployment. The goal of this paper is to define specific end-use cases for which DC distribution in buildings is a value proposition today by defining clear efficiency and resiliency benefits while addressing barriers to implementation. The paper begins with a technology and market assessment of DC distribution equipment, end uses, and technology standards. That is followed by results from an expert elicitation of DC power and building end-use professionals (e.g., electrical designers, building operators, engineers) and reports on-site visits and lessons learned from successful (and less successful) field deployments of DC distribution projects in North America. We present specific adoption pathways at the community and building level that can be implemented today, and evaluate them using qualitative and quantitative metrics, such as technology and market readiness, energy savings, and resiliency.

building-level electrical distribution↗

Putting Our Industry's Data to Work: A Case Study of Large-Scale Data Aggregation: Preprint

With increasing deployment of Advanced Metering Infrastructure (AMI), Building Automation System (BAS) controls, Internet of Things (IoT) network devices, and data-driven evaluation, measurement, and verification studies, the building sector is currently generating a staggering amount of energy-related data. In the right hands, these data sets can contribute to increased comfort and energy savings for building occupants and a more reliable electrical grid; however, due to a combination of factors, including significant privacy concerns, much of the data that are presently generated and stored are not used outside of basic operational applications. In the past year, our team has dedicated over 2,000 person-hours to accessing building energy data for a project funded by the U.S. Department of Energy (DOE) Building Technologies Office. We sought whole-building or end-use (e.g., lighting) timeseries data at the individual-building or equipment level where possible or aggregated information, such as timeseries averages and quartiles by building type (e.g., office, retail, hospital), where sharing individual building information was not an option. We are additionally working with IoT and BAS data sets to derive information important to the project. We have assembled an extensive data set that will enable the development of publicly available end-use load profiles to benefit the U.S. building and electricity industries. Here we present an overview of the data set that we have assembled to date, the motivators and approaches that got us here, and the lessons we learned through our efforts. We also discuss work underway that presents additional options for future data access.

building energy data↗

An Open-Source Framework for Characterizing Urban Energy Models: Integrating Top-Down and Bottom-Up Methods to Predict Residential Buildings Characteristics: Preprint

Bottom-up urban energy models are crucial for understanding current energy use patterns and informing design strategies. However, accurately characterizing these models to represent different communities remains a challenge due to the extensive data needed for simulating existing energy use behavior. This data includes information related to human activities and building characteristics, all of which correlate with socioeconomic factors. To overcome this challenge, we developed an automated framework that utilizes both top-down and bottom-up data, to predict unknown building and occupant characteristics that are needed for more accurate and equitable modeling and analytics. Our framework, integrated into the URBANopt district energy modeling platform, uses statistical data models from ResStock. URBANopt models co-located buildings and neighborhoods. At this scale there are data gaps in building characteristic data, such as materials, insulation, occupancy, income, and energy usage of the buildings. To address this data gap, we use ResStock data, representative at the census tract scale, and develop machine-learning and deeplearning techniques to disaggregate it to individual buildings. By mapping unique occupant, building and economic properties to URBANopt energy models, we gain detailed insights into the variability of building energy use across different neighborhoods. This insight helps deploy technologies for co-located buildings and supports targeted upgrades for communities with unique economic and demographic characteristics, ensuring energy equity. Accurate characterization of energy models allows us to develop equitable strategies tailored to diverse neighborhoods, whether underserved or affluent. Our automated framework streamlines energy modeling and provides a reliable tool for building energy characterization.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Operating Hardware Impact on the Heat Transfer Properties of Windows

Despite significant advancements in fenestration technology in the last two decades, the thermal transmittance of fenestration products is still significantly higher than that of walls. This corresponds to 60% of the total energy loss of a modern building envelope through the windows. Hence, further development and improvements of fenestration products are necessary. Increasingly stringent codes and standards for fenestration stimulate industry to work on improved solutions. Thus, it is crucial that assessment techniques are able to account for innovations accurately. The thermal effects of non-continuous hardware in window frames are currently ignored by international rating procedures. A preliminary investigation conducted by our team showed significant performance degradation in two of the three out-opening casement profiles caused by the presence of operating hardware. Frames with the structure made of vinyl and fiberglass consist of many air cavities that are penetrated by operating hardware made of highly conductive materials. In these frames, in order to have an accurate assessment, it may be required to employ three-dimensional modeling due to the convective nature of heat transfer within the cavities. However, in this study, we demonstrate that the three-dimensional (3D) effects of non-continuous hardware can be approximated accurately with simpler two-dimensional (2D) simulations. We then develop a simplified model based on weighted average capable of replacing the time- and computation-intensive 3D simulations with 2D simulations and validate it against market available frames and their corresponding hardware. Validation results show that our approximation technique results in discrepancies lower than 0.05 W/(m2K), or 3% of the total thermal transmittance. Thus, we conclude that simplified 2D simulation models may be used for predicting hardware impact in window frames with reasonable accuracy. As windows and glazing structures are becoming ever better thermally insulated, it is becoming even more important to be able to model the impact of the operating hardware on the total thermal performance in order to design the best windows possible and not let the operating hardware ruin an otherwise well-proven design, which is hence addressed in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗