Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Techno-Economic Analysis of Green Hydrogen Energy Storage in a Cryogenic Flux Capacitor

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. Hydrogen storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 36% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at improved densities, but testing is ongoing. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce green GH2. The TEA compares pure hydrogen produced at a small scale for a 25 MW power system and at a large scale in a 500 MW power system. The system allowed for hydrogen imports and exports at a set price with a tank sized for 10 hours of power production. The two power producing technologies are a combined cycle gas turbine (CCGT) and hydrogen fuel cells. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), and levelized cost of storage (LCOS) are developed based on the capital cost and operating cost of the systems. The results are shown for current costs using a 2021 benchmark and DOE projections for cost improvements by 2030. The TEA showed that onsite hydrogen generation from SMR has an LCOH of about 1.4 to 2 USD per kg over the life of the plant and the PV hydrogen production LCOH is about 5.2 to 5.5 USD per kg. The LCOS of conventional GH2 systems is estimated to be $210/MWh and cost of storage for LH2 systems is $205/MWh for fuel cell systems and $249/MWh for CCGT systems. CFC improved the LCOS of all these systems to $198/MWh, $191/MWh and $233/MWh respectively. The LCOE also improved with conventional systems between $171/MWh and $228/MWh improved by CFC to between $167/MWh and $212/MWh. Using projections for improvement in costs following DOE’s goals by 2030, green hydrogen improved to as low as $78/MWh LCOS and LCOE for conventional cases. CFC improved over conventional storage with the lowest LCOS being $62/MWh and the lowest LCOE being $73/MWh. These results correspond to an LCOH of $2/kg. Finally, the TEA shows how LCOE is improved for hydrogen conditioning and storage over conventional systems and caverns in the 10 to 50 hour range.

08 HYDROGEN↗

Improvements realized on the cryogenic solution called NiThrow{sub TM}

The economic, environmental, social and societal constraints have pushed the nuclear industry to develop new dismantling and decommissioning (D and D) techniques in order to meet the current industrial requirements. Since 5 years, AREVA, in partnership with Air Liquide, has been working on a new cryogenic solution that can be used to achieve the main important D and D operations (i.e. cutting, surface decontamination and concrete scrabbling). This solution, called NiThrow{sup TM}, is based on the Nitrocision LLC concept and consists in spraying highly pressurized liquid nitrogen (3500 bar) at a very low temperature (-140 deg. C) onto a surface. The main advantage in using liquid nitrogen instead of water is due to its rapid conversion into gaseous nitrogen that will avoid the generation of liquid effluent. The preliminary trials made in France at Saint Ouen l'Aumone and at the AREVA SICN facility by using NiThrow{sup TM} appeared to be very interesting and promising in terms of effectiveness, reduction of the dosimetry (i.e. ALARA principle) and adaptability to the different types of surfaces and materials to be treated. On an other hand, they also highlighted a couple of defects like a lack of reliability that is not compatible with a safety use in a nuclear environment. In 2009, with the aim of fixing all these issues, AREVA decided to start an extensive R and D program. This work has been essentially focused on the lancing tool, the insulation and the flexibility of the liquid nitrogen distribution network, but also on the design and the manufacturing of a waste collection unit and a dedicated carrier. Today, these R and D efforts have been totally completed. and resulted to the publication of 3 patents. Also, the collaboration, with Air Liquide and the American company Conco allows AREVA to propose to its customers a safe and reliable solution for their cleaning operations in France and all over the world. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A prototype of an electric-discharge gas flow oxygen−iodine laser: I. Modeling of the processes of singlet oxygen generation in a transverse cryogenic slab RF discharge

The existing kinetic model describing self-sustained and electroionization discharges in mixtures enriched with singlet oxygen has been modified to calculate the characteristics of a flow RF discharge in molecular oxygen and its mixtures with helium. The simulations were performed in the gas plug-flow approximation, i.e., the evolution of the plasma components during their motion along the channel was represented as their evolution in time. The calculations were carried out for the O{sub 2}: He = 1: 0, 1: 1, 1: 2, and 1: 3 mixtures at an oxygen partial pressure of 7.5 Torr. It is shown that, under these conditions, volumetric gas heating in a discharge in pure molecular oxygen prevails over gas cooling via heat conduction even at an electrode temperature as low as ~100 K. When molecular oxygen is diluted with helium, the behavior of the gas temperature changes substantially: heat removal begins to prevail over volumetric gas heating, and the gas temperature at the outlet of the discharge zone drops to ~220–230 K at room gas temperature at the inlet, which is very important in the context of achieving the generation threshold in an electric-discharge oxygen−iodine laser based on a slab cryogenic RF discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cryogenic Carbon Capture™ (CCC) Status Report

The Cryogenic Carbon Capture™ (CCC) process separates CO2 from light gases in essentially any continuous process. CCC cools the gases to the frost or desublimation point of CO2 (-100 to -135 °C), separates and pressurizes the solids, and warms all streams to produce a CO2-depleted stream at ambient pressure and a pure (99+%) pressurized liquid CO2 stream typically to about 150 bar, both at ambient temperature. The process also recovers all gas moisture and most gas impurities less volatile than CO2 (NOx, SOx, Hg, PM, UHC, CCC, etc.) in separable streams. CCC nearly eliminates refrigeration energy for sensible temperature changes through heat integration. CCC does require energy to change the CO2 phase from a mixed vapor to a pressurized fluid, which represents the minimum energy required of any process for this separation. CCC uses additional energy for turbomachinery inefficiencies, heat losses, moisture removal and overall process pressure drop. Aside from these real-world energy demands, CCC operates near the minimum energy required to perform this gas separation by minimizing stream recycling. CCC compresses CO2 as a liquid, which is one of several reasons it costs about about half as much and consumes about half as much energy as an amine process when using flue gases with about 15% CO2. The process also has several major additional advantages, including (a) it is a bolt-on retrofit technology that does not need steam or any modification of existing equipment, (b) it recovers water and nearly all pollutants in addition to CO2 from the flue gas, (c) it enables highly efficient and cost effective energy storage at grid scale and on time scales of minutes, (d) it enables NG storage if the energy storage option is used, and (d) it has a small footprint and is minimally disruptive to existing plants, requiring only electrical power and a gas source to operate. Sustainable Energy Solutions (SES) has scaled this technology through several levels, the largest of which captures nominally 1 tonne of CO2/day and is called the skid system. Skid system field tests include utility-scale power plants, cement plants, heating plants, and other utility or industrial sites that burn natural gas, biomass, coal, shredded tires, municipal waste, and combinations of these fuels. These field tests produced 95-99% CO2 capture with CO2 purities of 99+% and initial CO2 contents that range from 4 to 28%. SES currently seeks to scale the system to merchant scale (10-80 tonnes of CO2 per day). In the process of doing so, SES has demonstrated the potential for CCC to contribute to energy storage and direct air capture in innovative and cost-effective ways. This presentation discusses the overall process and highlights results from field and in-house tests. These include (a) measured CO2 capture rates and operating conditions from in-house and field tests, and (b) predicted utility-scale costs and energy demands. This discussion also includes the application of the CCC technology to energy storage and direct air capture.

20 FOSSIL-FUELED POWER PLANTS↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗

Recent Cryogenic Carbon Capture™ Field Test Results

Sustainable Energy Solutions (SES) has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time, two processes have been developed, the External Cooling Loop and Compressed Flue Gas CCC processes (CCC-ECL and CCC-CFG, respectively). The CCC-ECL process cools the flue gas with an external refrigerant loop. This process currently captures up to 1 tonne of CO2 per day (TPD). SES has tested CCC-ECL on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cement kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC-CFG process has been scaled up to a 0.25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal, and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2, and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC-CFG was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC generally, the results of CCC-ECL field testing, and future steps surrounding the development of this technology. Test results that will be presented have been collected during 9 months of testing at a commercial power plant under funding from the US Department of Energy (DOE) and the host utility. Testing of one of the systems at a commercial cement plant in the United States will also be discussed. During this testing, the system captured CO2 from the cement plant and stored the CO2 in pressurized tanks. These tanks were provided to a partner company that later used the CO2 in a CO2 utilization demonstration. The CO2 was utilized to cure concrete manufactured using cement from the same plant where the CO2 was captured. This integrated capture and utilization demonstration was the first time that the cement industry has shown in the field that it can sequester its CO2 emissions in its main product stream. This represents a potential game changing solution for industrial CO2 emissions. Operational data and host-site feedback indicate that the CCC process is ideally suited for deployment into a variety of commercial environments. A few areas of de-risking remain to make sure the technology can meet very strict industrial reliability standards. These areas of de-risking are identified and discussed. The product CO2 is shown to meet specification for many uses including industrial and merchant applications. The technology is nearing readiness for deployment at commercial scale and several initial target markets have been identified.

20 FOSSIL-FUELED POWER PLANTS↗

Development of a Navigator and Imaging Techniques for the Cryogenic Dark Matter Search Detectors

This project contributes to the detection of flaws in the germanium detectors for the Cryogenic Dark Matter Search (CDMS) experiment. Specifically, after imaging the detector surface with a precise imaging and measuring device, they developed software to stitch the resulting images together, applying any necessary rotations, offsets, and averaging, to produce a smooth image of the whole detector that can be used to detect flaws on the surface of the detector. These images were also tiled appropriately for the Google Maps API to use as a navigation tool, allowing viewers to smoothly zoom and pan across the detector surface. Automated defect identification can now be implemented, increasing the scalability of the germanium detector fabrication.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparing the Calibration and Simulation Data of the Cryogenic Dark Matter Search

The Cryogenic Dark Matter Search, or CDMS, collaboration is preparing a new experiment called SuperCDMS. CDMS uses Germanium detectors to attempt the direct detection of dark matter. To do this, they measure the ionization and heat produced during an event where a WIMP scatters off of germanium crystal lattice. To prepare for the experiment the detectors are calibrated with various radioactive sources. The response of the detectors is also modeled by a Monte Carlo simulation. These simulations include modeling everything from the radiation production to the raw data collected by the detector. The experimental data will be used to validate the results of the detector simulation. This research will look only at the phonons produced during events that occur very close to the detector surface. From the raw data and simulation output three parameters will be determined: the rise time, the decay time, and time to position independence. It was found that the simulation's risetime and time to position independence was generally smaller than that of the data, while the decay time was found to be larger in the simulation than in the data. These differences show that the simulation is not complete. The difference in risetime implies that the phonons are not spread out enough when they reach the detector walls, which would be improved by a look at the Luke phonon and charge transport. The long decay time in the simulation implies that the rate phonons are being absorbed is underestimated. Finally, the small time to position independence in the simulation could be due to a low phonon scattering rate. A simple solution may be to alter the parameters that control the simulation, while still remaining physically sensible, to help match simulation and data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Techno-economic Analysis of the Cryogenic Flux Capacitor Compared to Other forms of Hydrogen Production and Storage

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. The hydrogens storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 49% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at equivalent densities. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce GH2. The TEA compares pure hydrogen burning in a combined cycle gas turbine (CCGT) to hydrogen fuel cells with an overall net power output of 650 MW. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity is developed based on the capital cost and operating cost of the systems. Sensitivities are discussed around the cost of natural gas, ranging from 1.93 USD per MMBTU to 6.75 USD per MMBTU, and carbon dioxide disposal, ranging from 7 USD per tonne to 10 USD per tonne. For comparison to the conventional CCGT baseline, a baseload scenario is adopted with 85% capacity factor. The results of the study show that onsite hydrogen generation from SMR is about 1 to 3 USD per kg over the life of the plant and the PV hydrogen production produces at 4 to 5 USD per kg. The cost of storage for CFC is compared to other systems, including high-pressure GH2 and atmospheric LH2. The system is shown to provide the lowest costs for all these options at the grid scale, due to its higher capacity than high-pressure GH2 and ability to operate at 80K, receiving refrigeration from liquid nitrogen systems reducing capital and operating costs when compared LH2 storage systems. SMR is competitive with CCGT at the gas prices, both of which have lower LCOE than the PV system. When accounting for variability in gas prices, the PV and electrolyzer system is less sensitive to these changes and provides the lowest LCOE across the whole range.

08 HYDROGEN↗

A search for particle dark matter using cryogenic germanium and silicon detectors in the one- and two- tower runs of CDMS-II at Soudan

Images of the Bullet Cluster of galaxies in visible light, X-rays, and through gravitational lensing confirm that most of the matter in the universe is not composed of any known form of matter. The combined evidence from the dynamics of galaxies and clusters of galaxies, the cosmic microwave background, big bang nucleosynthesis, and other observations indicates that 80% of the universe's matter is dark, nearly collisionless, and cold. The identify of the dar, matter remains unknown, but weakly interacting massive particles (WIMPs) are a very good candidate. They are a natural part of many supersymmetric extensions to the standard model, and could be produced as a nonrelativistic, thermal relic in the early universe with about the right density to account for the missing mass. The dark matter of a galaxy should exist as a spherical or ellipsoidal cloud, called a 'halo' because it extends well past the edge of the visible galaxy. The Cryogenic Dark Matter Search (CDMS) seeks to directly detect interactions between WIMPs in the Milky Way's galactic dark matter halo using crystals of germanium and silicon. Our Z-sensitive ionization and phonon ('ZIP') detectors simultaneously measure both phonons and ionization produced by particle interactions. In order to find very rare, low-energy WIMP interactions, they must identify and reject background events caused by environmental radioactivity, radioactive contaminants on the detector,s and cosmic rays. In particular, sophisticated analysis of the timing of phonon signals is needed to eliminate signals caused by beta decays at the detector surfaces. This thesis presents the firs two dark matter data sets from the deep underground experimental site at the Soudan Underground Laboratory in Minnesota. These are known as 'Run 118', with six detectors (1 kg Ge, 65.2 live days before cuts) and 'Run 119', with twelve detectors (1.5 kg Ge, 74.5 live days before cuts). They have analyzed all data from the two runs together in a single, combined analysis, with sensitivity to lower-energy interactions, careful control of data quality and stability, and further development of techniques for reconstructing event location and rejecting near-surface interactions from beta decays. They also present a revision to the previously published Run 119 analysis, a demonstration of the feasibility of a low-threshold (1 or 2 keV) analysis of Soudan data, and a review of the literature on charge generation and quenching relevant to the ionization signal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Online monitoring the hydrolysis of uranium hexafluoride for intermediates by cryogenic layering and FTIR

Uranium hexafluoride (UF 6 ) is a commonly utilized material feedstock in uranium enrichment processes due to its high vapor pressure and ease of sublimation. When exposed to air, UF 6 undergoes spontaneous hydrolysis to form uranyl fluoride (UO 2 F 2 ) particulates which are utilized for the detection of undeclared nuclear activities by nuclear safeguards organizations. In this study, the kinetics of the hydrolysis reaction and how they relate to particle morphology of the product are still debated in the literature. Here, we report the direct, in situ observation of UF 6 reaction intermediates by cooling the reaction to cryogenic temperatures to significantly reduce the rate of hydrolysis. The reaction is then observable by Fourier transform infrared (FTIR) spectroscopy. The conversion of UF 6 to UOF 4 is observed as well as several other bands associated with possible long lived intermediate complexes. Chemometrics are used to further elucidate the reaction pathway from UF 6 to UO 2 F 2 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of Near-Field Magnetic Responses on ZrTe 5 through Cryogenic Magneto-THz Nano-Imaging

One manifestation of light-Weyl fermion interaction is the emergence of chiral magnetic effects under magnetic fields. Probing real space magnetic responses at terahertz (THz) scales is challenging but highly desired, as the local responses are less affected by the topologically trivial inhomogeneity that is ubiquitous in spatially averaged measurements. Here, we implement a cryogenic THz microscopy instrument under a magnetic field environment—a task only recently achieved. We explore the technical approach of this system and characterize the magnetic field’s influence on our AFM operation by statistical noise analysis. We find evidence for local near-field spatial variations in the topological semimetal ZrTe 5 up to a 5-Tesla magnetic field and obtain near-field THz spectra to discuss their implications for future studies on the chiral magnetic effect.

36 MATERIALS SCIENCE↗

REPEATABILITY AND ACCURACY OF EXOPLANET ECLIPSE DEPTHS MEASURED WITH POST-CRYOGENIC SPITZER

We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5 μ m data set, consisting of 10 observations of the XO-3b system during secondary eclipse, using seven different techniques for removing correlated noise. We find that, on average, for a given technique, the eclipse depth estimate is repeatable from epoch to epoch to within 156 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 3 of the photon noise limit. All methods but one accurately assess their own errors: for these methods, the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10 epoch sample. To assess the accuracy of the techniques as well as to clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated data set of 10 visits to XO-3b, for which the eclipse depth is known. We find that three of the methods (BLISS mapping, Pixel Level Decorrelation, and Independent Component Analysis) obtain results that are within three times the photon limit of the true eclipse depth. When averaged over the 10 epoch ensemble, 5 out of 7 techniques come within 60 ppm of the true value. Spitzer exoplanet data, if obtained following current best practices and reduced using methods such as those described here, can measure repeatable and accurate single eclipse depths, with close to photon-limited results.

79 ASTRONOMY AND ASTROPHYSICS↗