Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

The Impact of Neutron Transfer Reactions on the Heating and Cooling of Accreted Neutron Star Crusts

Abstract Nuclear reactions heat and cool the crust of accreting neutron stars and need to be understood to interpret observations of X-ray bursts and long-term cooling in transiently accreting systems. It was recently suggested that previously ignored neutron transfer reactions may play a significant role in the nuclear processes. We present results from full nuclear network calculations that now include these reactions and determine their impact on crust composition, crust impurity, heating, and cooling. We find that a large number of neutron transfer reactions indeed occur and impact crust models. In particular, we identify a new type of reaction cycle that brings a pair of nuclei across the nuclear chart into equilibrium via alternating neutron capture and neutron release, interspersed with a neutron transfer. While neutron transfer reactions lead to changes in crust model predictions and need to be considered in future studies, previous conclusions concerning heating, cooling, and compositional evolution are remarkably robust.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Properties of the Prompt Optical Counterpart Arising from the Cooling of Electrons in Gamma-Ray Bursts

This work extends a contemporaneous effort to study the properties of the lower-energy counterpart synchrotron emission produced by the cooling of relativistic gamma-ray burst (GRB) electrons through radiation (synchrotron and self-Compton) emission and adiabatic losses. We derive the major characteristics (pulse duration, lag time after burst, and brightness relative to the burst) of the prompt optical counterpart (POC) occurring during or after the GRB. Depending on the magnetic field lifetime, duration of electron injection, and electron transit time Δt o from hard X-ray (GRB) to optical-emitting energies, a POC may appear during the GRB pulse (of duration δt γ ) or after (delayed OC). The signature of counterparts arising from the cooling of GRB electrons is that POC pulses (Δto < δtγ) last as long as the corresponding GRB pulse (δt o ≃ δt γ ), while delayed OC pulses (Δt o > δt γ ) last as long as the transit time (δt o ≃ Δt o ). If OC variability can be measured, then another signature for this OC mechanism is that the GRB variability is passed on to POCs but not to delayed OCs. Within the GRB electron cooling model for counterparts, POCs should be on average dimmer than delayed ones (consistent with the data), and harder GRB low-energy slopes β LE should be associated more often with the dimmer POCs. The latter sets an observational bias against detecting POCs from (the cooling of electrons in) GRBs with a hard slope β LE , making it more likely that the detected POCs of such bursts arise from another mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

COOL-LAMPS. II. Characterizing the Size and Star Formation History of a Bright Strongly Lensed Early-type Galaxy at Redshift 1.02

We present COOL J1323+0343, an early-type galaxy at z = 1.0153 ± 0.0006, strongly lensed by a cluster of galaxies at z = 0.353 ± 0.001. This object was originally imaged by DECaLS and noted as a gravitational lens by COOL-LAMPS, a collaboration initiated to find strong-lensing systems in recent public optical imaging data, and confirmed with follow-up data. With ground-based grzH imaging and optical spectroscopy from the Las Campanas Observatory and the Nordic Optical Telescope, we derive a stellar mass, metallicity, and star formation history from stellar-population synthesis modeling. The lens modeling implies a total magnification, summed over the three images in the arc, of μ ~ 113. The stellar mass in the source plane is M * ~ 10.64 M ⊙ and the 1σ upper limit on the star formation rate (SFR) in the source plane is SFR ~ 3.75 × 10 -2 M ⊙ yr -1 (log sSFR = -12.1 yr -1 ) in the youngest two age bins (0–100 Myr), closest to the epoch of observation. Our measurements place COOL J1323+0343 below the characteristic mass of the stellar mass function, making it an especially compelling target that could help clarify how intermediate-mass quiescent galaxies evolve. We reconstruct COOL J1323+0343 in the source plane and fit its light profile. This object is below the expected size evolution of an early-type galaxy at this mass with an effective radius r e ~ 0.5 kpc. This extraordinarily magnified and bright lensed early-type galaxy offers an exciting opportunity to study the morphology and star formation history of an intermediate-mass early-type galaxy in detail at z ~ 1.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing the Impact of Radio-mode Feedback on the Properties of the Cool Circumgalactic Medium

We explore the influence of radio-mode feedback on the properties of the cool circumgalactic medium (CGM). To this end, we assemble a statistical sample of approximately 30,000 radio galaxies with background quasars by combining optical spectroscopic measurements of luminous red galaxies and quasars from the year 1 data set of the Dark Energy Spectroscopic Instrument and radio sources from the LOw-Frequency ARray Two-metre Sky Survey (LoTSS) DR2 catalog and the Very Large Array Sky Survey (VLASS) quick-look catalog. Galaxies with similar optical properties but with no radio counterparts in LoTSS and VLASS are selected as the control group. We measure the cool CGM properties of radio galaxies and their control samples traced by Mg ii absorption lines, including covering fraction, rest equivalent width, and gas kinematics. Our results show no significant difference in the properties of gas around radio galaxies and their control sample, indicating that the operating radio-mode feedback of massive galaxies does not produce detectable effects on the properties of the cool CGM. Finally, we show that the CGM of radio galaxies contains a nonnegligible amount of cool gas with approximately 10 10 M ⊙ . This abundance can place a stringent constraint on the radio-mode feedback models.

79 ASTRONOMY AND ASTROPHYSICS↗

MESA Isochrones and Stellar Tracks (MIST). III. The White Dwarf Cooling Sequence

We present a substantial update to the MESA Isochrones and Stellar Tracks (MIST) library, extending the MIST model grids and isochrones down the white dwarf (WD) cooling sequence with realistic physics for WD cooling timescales. This work provides a large grid of MESA models for carbon–oxygen core WDs with hydrogen atmospheres (spectral type DA/DC), descended from full prior stellar evolution calculations. The model tracks, isochrones, and WD cooling timescale contours are available on the MIST project website and at doi:10.5281/zenodo.15242047. Our WD models provide a very large, publicly available grid with detailed physics for WD cooling timescales: realistic interior and envelope compositions, with element diffusion and heavy-element sedimentation, nuclear burning at the base of the WD hydrogen envelope, core crystallization, and C/O phase separation. As a large grid of open-source stellar evolution models, these WD models provide both out-of-the-box model tracks for comparison with observations and a framework for building further WD models to investigate variations in WD physics.

Astronomy and AstroPhysics↗

22 Ne Phase Separation as a Solution to the Ultramassive White Dwarf Cooling Anomaly

The precise astrometric measurements of the Gaia Data Release 2 have opened the door to detailed tests of the predictions of white dwarf cooling models. Significant discrepancies between theory and observations have been identified, the most striking affecting ultramassive white dwarfs. Cheng et al. found that a small fraction of white dwarfs on the so-called Q branch must experience an extra cooling delay of ~8 Gyr not predicted by current models. 22 Ne phase separation in a crystallizing C/O white dwarf can lead to a distillation process that efficiently transports 22 Ne toward its center, thereby releasing a considerable amount of gravitational energy. Here, using state-of-the-art Monte Carlo simulations, we show that this mechanism can largely resolve the ultramassive cooling anomaly if the delayed population consists of white dwarfs with moderately above-average 22 Ne abundances. We also argue that 22 Ne phase separation can account for the smaller cooling delay currently missing for models of white dwarfs with more standard compositions.

79 ASTRONOMY AND ASTROPHYSICS↗

On the minimum number of radiation field parameters to specify gas cooling and heating functions

Fast and accurate approximations of gas cooling and heating functions are needed for hydrodynamic galaxy simulations. We use machine learning to analyze atomic gas cooling and heating functions computed by Cloudy in the presence of a generalized incident local radiation field. We characterize the radiation field through binned radiation field intensities instead of the photoionization rates used in our previous work. We find a set of 6 energy bins whose intensities exhibit relatively low correlation. We use these bins as features to train machine learning models to predict Cloudy cooling and heating functions at fixed metallicity. We compare the relative SHapley Additive exPlanation (SHAP) value importance of the features. From the SHAP analysis, we identify a feature subset of 3 energy bins ($0.5-1, 1-4$, and $13-16 \, \mathrm{Ry}$) with the largest importance and train additional models on this subset. We compare the mean squared errors and distribution of errors on both the entire training data table and a randomly selected 20% test set withheld from model training. The machine learning models trained with 3 and 6 bins, as well as 3 and 4 photoionization rates, have comparable accuracy everywhere, with errors $\gtrsim 10$ times smaller than for the interpolation table of Gnedin and Hollon (2012). We conclude that 3 energy bins (or 3 analogous photoionization rates: molecular hydrogen photodissociation, neutral hydrogen HI, and fully ionized carbon CVI) are sufficient to characterize the dependence of the gas cooling and heating functions on our assumed incident radiation field model.

79 ASTRONOMY AND ASTROPHYSICS↗

A feasibility study of heat-pipe-cooled leading edges for hypersonic cruise aircraft

A theoretical study of the use of heat pipe structures for cooling the leading edges of hypersonic cruise aircraft was carried out over a Mach number range of 6 to 12. Preliminary design studies showed that a heat pipe cooling structure with a 33-in. chordwise length could maintain the maximum temperature of a 65 deg sweepback wing with a 0.5-in. leading edge radius below 1600 F during cruise at Mach 8. A few relatively minor changes in the steady-state design of the structure were found necessary to insure satisfactory cooling during the climb to cruise speed and altitude. It was concluded that heat pipe cooling is an attractive, feasible technique for limiting leading edge temperatures of hypersonic cruise aircraft.

Silverstein, C. C.↗

Emergency cooling analysis for the loss of coolant malfunction

This report examines the dynamic response of a conceptual space power fast-spectrum lithium cooled reactor to the loss of coolant malfunction and several emergency cooling concepts. The results show that, following the loss of primary coolant, the peak temperatures of the center most 73 fuel elements can range from 2556 K to the region of the fuel melting point of 3122 K within 3600 seconds after the start of the accident. Two types of emergency aftercooling concepts were examined: (1) full core open loop cooling and (2) partial core closed loop cooling. The full core open loop concept is a one pass method of supplying lithium to the 247 fuel pins. This method can maintain fuel temperature below the 1611 K transient damage limit but requires a sizable 22,680-kilogram auxiliary lithium supply. The second concept utilizes a redundant internal closed loop to supply lithium to only the central area of each hexagonal fuel array. By using this method and supplying lithium to only the triflute region, fuel temperatures can be held well below the transient damage limit.

Peoples, J. A.↗

Hot-gas-side heat transfer with and without film cooling on a simulated nuclear rocket thrust chamber using H2-O2

Heat-transfer coefficients were obtained on a thrust chamber which simulated the geometry of the NERVA nuclear rocket. The tests were performed with and without peripheral film cooling over a chamber pressure range of 1.05 million to 5.84 million newtons per square meter (153 to 847 psia). With no film cooling, the overall axial variation in the value of the correlation coefficient C of the equation (Stanton)* (Prandtl)* to the 0.7ths power = C(Reynolds)* to the -0.2ths power, where * indicates the reference enthalpy condition, was reduced 66 percent when the local diameter in the Reynolds number was replaced by the axial distance from the injector face. The average peak values of C were reduced 25 percent with 2 and 3.75 percent cooling and 50 percent with 7.5 percent cooling.

Quentmeyer, R. J.↗

Non-isothermal laminar flow of gases through cooled tubes.

Numerical solutions of the laminar-flow equations in differential form are presented for gas flows through cooled tubes. For nearly isothermal flow there is good agreement with available experimental data, as is also found for the case of a large amount of wall cooling. This correspondence along with a check on the satisfaction of the global momentum and energy constraints allowed an appraisal of the effect of wall cooling on flow through tubes. In general, the effect of wall cooling was to decrease the wall friction and the change in pressure along tubes, but the average heat-transfer coefficient did not vary much.

Back, L. H.↗

Cooling of dense stars

Cooling rates were calculated for neutron stars of about one solar mass and 10 km radius, with magnetic fields from zero to about 10 to the 14th power gauss, for extreme cases of maximum and zero superfluidity. The results show that most pulsars are so cold that thermal ionization of surface atoms would be negligible. Nucleon superfluidity and crystallization of heavy nuclei were treated quantitatively, and more realistic hadron star models were chosen. Cooling rates were calculated for a stable hyperon star near the maximum mass limit, a medium weight neutron star, and a light neutron star with neutron-rich heavy nuclei near the minimum mass limit. Results show that cooling rates are a sensitive function of density. The Crab and Vela pulsars are considered, as well as cooling of a massive white dwarf star.

Tsuruta, S.↗

Hydrogen film/conductive cooling

Small scale nozzle tests using heated nitrogen were run to obtain effectiveness and wall heat transfer data with hydrogen film cooling. Effectiveness data are compared with an entrainment model developed from planar, unaccelerated flow data. Results indicate significant effects due to flow turning and acceleration. With injection velocity effects accounted for explicitly, heat transfer correlation coefficients were found to be the same with and without film cooling when properties are evaluated at an appropriate reference temperature for the local gas composition defined by the coolant effectiveness. A design study for an O2/H2 application with 300 psia (207 N/sq cm) chamber pressure and 1500 lbs (6670 N) thrust indicates an adiabatic wall design requires 4 to 5 percent of the total flow as hydrogen film cooling. Internal regenerative cooling designs were found to offer no reduction in coolant requirements.

Ewen, R. L.↗

Effect of pressure on tangential-injection film cooling in a combustor exhaust stream

A tangential-injection film cooled test section was placed in the exhaust stream of a high pressure combustor. Film cooling data were taken at pressure of 1, 10, and 20 atmospheres. The film cooling effectiveness was found to be independent of pressure. The data were correlated adequately by a turbulent-mixing film cooling correlation with a turbulent-mixing coefficient of 0.05 + or - 0.02.

Marek, C. J.↗

Liquid rocket engine fluid-cooled combustion chambers

A monograph on the design and development of fluid cooled combustion chambers for liquid propellant rocket engines is presented. The subjects discussed are (1) regenerative cooling, (2) transpiration cooling, (3) film cooling, (4) structural analysis, (5) chamber reinforcement, and (6) operational problems.

Source record↗

Hydrogen film cooling investigation

Effects of flow turning, flow acceleration, and supersonic flow on film cooling were determined experimentally and correlated in terms of an entrainment film cooling model. Experiments were conducted using thin walled metal test sections, hot nitrogen mainstream gas, and ambient hydrogen or nitrogen as film coolants. The entrainment film cooling model relates film cooling effectiveness to the amount of mainstream gases entrained with the film coolant in a mixing layer. The experimental apparatus and the analytical model used are described in detail and correlations for the entrainment fraction and film coolant-to-wall heat transfer coefficient are presented.

Rousar, D. C.↗

Postponement of incipient collapse due to work-induced heat stress by limited cooling

Four subjects completed five treadmill training sessions under comfortable to cool conditions and were calibrated to find an optimum combination of speed and grade on the treadmill which would produce a metabolic rate of 2000 Btu-hr. Dressed in an Apollo liquid cooling garment, each man underwent a total of four experiments in which the rate of heat extraction from the liquid cooling garment was adjusted to an amount which would cause a storage within the body of 1000 Btu/hr. Physiological measurements included skin temperature at 9 locations, rectal and ear canal probes, and heart rate. The increases in tolerance time for the various subjects and the various methods of emergency cooling, ranged from a low of six minutes to a high of 48 minutes, or from 8 to 102% of the baseline tolerance times. The largest gains were achieved in a subject whose tolerance endpoint was atypical, and whose baseline heat tolerance was unsually low.

Blockley, W. V.↗

Comparative study of patches for liquid cooled garments.

Tests were performed on 12 cooling patches of various designs to establish criteria for the evaluation of their performance in liquid-cooled suits in industrial, military and aerospace applications. The thermal effectiveness value was 0.088 for patch designs with a double spiral flow pattern, and 0.075 for patch designs with a parallel flow pattern. The ratio of thermal energy transfer rate to cooling-medium pumping power requirement is indicated as the prime performance characteristic to be considered in the selection and rating of cooling patches.

Shitzer, A.↗