Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

A Consumer-Oriented Control Framework for Performance Analysis in Hybrid Electric Vehicles

Hybrid electric vehicles (HEVs) have attracted considerable attention due to their potential to reduce fuel consumption and emissions. Our objective with this paper is to enhance our understanding of the associated tradeoffs among the HEV subsystems, e.g., the engine, the motor, and the battery, and investigate the related implications for fuel consumption and battery capacity and lifetime. Addressing this problem can provide insights on how to prioritize these objectives based on consumers needs and preferences. The results of the proposed optimization approach can also be used to investigate the implications for HEV costs related to ownership and warranty.

25 ENERGY STORAGE↗

Parallel elastic elements improve energy efficiency on the STEPPR bipedal walking robot

This study describes how parallel elastic elements can be used to reduce energy consumption in the electric motor driven, fully-actuated, STEPPR bipedal walking robot without compromising or significantly limiting locomotive behaviors. A physically motivated approach is used to illustrate how selectively-engaging springs for hip adduction and ankle flexion predict benefits for three different flat ground walking gaits: human walking, human-like robot walking and crouched robot walking. Based on locomotion data, springs are designed and substantial reductions in power consumption are demonstrated using a bench dynamometer. These lessons are then applied to STEPPR (Sandia Transmission-Efficient Prototype Promoting Research), a fully actuated bipedal robot designed to explore the impact of tailored joint mechanisms on walking efficiency. Featuring high-torque brushless DC motors, efficient low-ratio transmissions, and high fidelity torque control, STEPPR provides the ability to incorporate novel joint-level mechanisms without dramatically altering high level control. Unique parallel elastic designs are incorporated into STEPPR, and walking data shows that hip adduction and ankle flexion springs significantly reduce the required actuator energy at those joints for several gaits. These results suggest that parallel joint springs offer a promising means of supporting quasi-static joint torques due to body mass during walking, relieving motors of the need to support these torques and substantially improving locomotive energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Privacy-Assured Aggregation Protocol for Smart Metering: A Proactive Fault-Tolerant Approach [Proactive Fault-Tolerant Aggregation Protocol for Privacy-Assured Smart Metering]

Smart meters are integral to demand response in emerging smart grids, by reporting the electricity consumption of users to serve application needs. But reporting real-time usage information for individual households raises privacy concerns. Existing techniques to guarantee differential privacy (DP) of smart meter users either are not fault tolerant or achieve (possibly partial) fault tolerance at high communication overheads. In this paper, we propose a fault-tolerant protocol for smart metering that can handle general communication failures while ensuring DP with significantly improved efficiency and lower errors compared with the state of the art. Our protocol handles fail-stop faults proactively by using a novel design of future ciphertexts, and distributes trust among the smart meters by sharing secret keys among them. We prove the DP properties of our protocol and analyze its advantages in fault tolerance, accuracy, and communication efficiency relative to competing techniques. We illustrate our analysis by simulations driven by real-world traces of electricity consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Modifying Network Guided Vehicle for Repeatable EcoCAR ACC Energy Testing

The newest iteration of the Department of Energy (DOE) Advanced Vehicle Technology Competitions is the EcoCAR Mobility Challenge. In this paper, ANL and HORIBA MIRA collaborate to propose and pilot a test method that enables controlled, repeatable track-based energy consumption testing of semi-autonomous features. The testing was performed at MIRA’s proving ground facility in Nuneaton, UK, using their Network Guided Vehicle (NGV) connectivity and automation test platform. The NGV served as a repeatable lead vehicle following prescribed drive traces around two different track circuits while the host vehicle under test, a Honda Civic with full speed range Adaptive Cruise Control, followed behind. Over the course of a two day test, multiple iterations of certification and custom EPA drive traces were performed on track, demonstrating the viability of a two vehicle energy test. Results were analyzed to assess NGV lead vehicle performance in following the prescribed cycle using SAE J2951 standard calculations in an effort to quantify how repeatably and accurately the lead vehicle followed the trace. Host vehicle energy consumption was assessed using both vehicle CAN bus monitoring and an on-board fuel flow meter.

ACC↗

The hidden roots of wetland methane emissions

Abstract Wetlands are the largest natural source of methane (CH 4 ) globally. Climate and land use change are expected to alter CH 4 emissions but current and future wetland CH 4 budgets remain uncertain. One important predictor of wetland CH 4 flux, plants, play an important role in providing substrates for CH 4 ‐producing microbes, increasing CH 4 consumption by oxygenating the rhizosphere, and transporting CH 4 from soils to the atmosphere. Yet, there remain various mechanistic knowledge gaps regarding the extent to which plant root systems and their traits influence wetland CH 4 emissions. Here, we present a novel conceptual framework of the relationships between a range of root traits and CH 4 processes in wetlands. Based on a literature review, we propose four main CH 4 ‐relevant categories of root function: gas transport, carbon substrate provision, physicochemical influences and root system architecture. Within these categories, we discuss how individual root traits influence CH 4 production, consumption, and transport (PCT). Our findings reveal knowledge gaps concerning trait functions in physicochemical influences, and the role of mycorrhizae and temporal root dynamics in PCT. We also identify priority research needs such as integrating trait measurements from different root function categories, measuring root‐CH 4 linkages along environmental gradients, and following standardized root ecology protocols and vocabularies. Thus, our conceptual framework identifies relevant belowground plant traits that will help improve wetland CH 4 predictions and reduce uncertainties in current and future wetland CH 4 budgets.

54 ENVIRONMENTAL SCIENCES↗

Potential of Utilizing Thermal Energy Storage Integrated Ground Source Heat Pump System to Reshape Electricity Demand in the United States

Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Altogether, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by –12% to 2%. The nationwide total electricity consumption would be reduced by 9%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling off-highway diesel engine downsizing and performance improvement using electrically assisted turbocharging

Internal combustion engine (ICE) downsizing through various turbocharging configurations is generally known by the powertrain design community as an effective means to reduce frictional losses, increase waste heat recovery, and improve fuel efficiency while increasing engine power density. However, often is the case that turbocharging strategies, including variable geometry turbochargers, and regulated two-stage turbochargers, incur the performance tradeoff between transient response and fuel economy (pumping losses) at high engine speeds. For off-highway vehicles having particularly transient and high-powered duty cycles, efforts to improve this tradeoff and increase operational flexibility have turned to evaluating various electrified air system architectures. In this study, a 4.5 L diesel-ICE configured with an electrically driven compressor (eBooster ® ) is placed in series with a conventional turbocharger and integrated into a 48 V mild-hybrid powertrain architecture. The objective of this powertrain configuration is to enable engine downsizing by 34%, replacing the current 6.8 L ICE platform with the hybridized 4.5 L ICE concept. The commercial 1-D simulation software GT-SUITE is used for powertrain system development and system optimization. Development and validation of the GT-SUITE model and air system controls is concurrently supported through experimental data collection. The simulation model development includes using machine learning methods for optimizing exhaust gas dilution, injection timing, and eBooster ® power to improve steady-state and transient brake-specific fuel consumption while minimizing criteria pollutant emissions. It was found that total specific fluid consumption over the standardized non-road transient engine duty cycle could be reduced by 18% over the current 6.8 L engine by using an optimized eBoosted 4.5 L engine. The hybridized 4.5 L engine concept concurrently showed sufficient transient response capability and nearly an order of magnitude reduction in duty cycle total soot production.

25 ENERGY STORAGE↗

Approach for energy efficient building design during early phase of design process

Energy consumption in the building sector is about 40% of total energy consumed globally and is trending upwards, along with its contribution to greenhouse gas (GHG) emissions. Given the adverse impacts of GHG emissions, it is crucial to integrate energy efficiency into building designs. The most significant opportunities for enhancing energy performance are present during the initial phases of building design, when there is less impact of other design constraints. Various tools exist for simulating different design options and providing feedback in terms of energy consumption and comfort parameters. These simulation outputs must then be analyzed to derive design solutions. This paper presents an innovative approach that utilizes user input parameters, processes them through cloud computing, and outputs easily understandable strategies for energy-efficient building design. The methodology employs Asynchronous Distributed Task Queues (DTQ) - a more scalable and reliable alternative to conventional speedup techniques-for conducting parametric energy simulations in the cloud. The goal of this approach is to assist design teams in identifying, visualizing, and prioritizing energy-saving design strategies from a range of possible solutions for each project. Furthermore, a tool ‘eDOT’ has been developed utilizing the discussed methodology. Unlike existing tools, eDOT leverages artificial intelligence to dynamically generate and provide design strategies during the early phases of design process. By simplifying the simulation process, eDOT enables design teams to make informed, data-driven decisions without needing to interpret complex simulation outputs. A case study simulated for two locations is provided in this paper to demonstrate the effectiveness of eDOT, further underscoring its practical impact on energy-efficient building design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GridPIQ Reference Data

GridPIQ uses dozens of publicly available datasets to provide context for a user's grid project, as well as defaults for users to choose from. Users can choose to import their own data to better customize their analysis or use GridPIQ-supplied defaults. This allows users to get up and running with an analysis very quickly without having to spend significant time pulling together input data. To run an electric vehicle (EV) smart charging project, a user will need to provide or select from prepopulated values for the regional load profile shape and peak load, region of interest and closest weather station, EV charging profile, number of EVs to add for the analysis, maximum EV charging power, location of chargers relative to grid infrastructure, and allowable charging times (for coordinated charging mode). The outputs of the analysis are changes in air quality, EV energy consumption, EV peak demand, and EV hourly consumption profile—before and after project implementation." For a detailed description of the tool methodology, including all the publicly available datasets used by the tool, see the [GridPIQ documentation](https://gridpiq.pnnl.gov/v2-beta/doc/).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Analysis: Ways to Save Energy and Reduce the Emissions in Wastewater Treatment Plants

The key of this study is to explore the primary energy consumers in wastewater treatment plants, which is considered as one of the major energy consumers, and introduces the best solution to save energy and reduce emissions in these facilities. This study is based on the energy assessment and analyses of eleven wastewater treatment plants. Through the investigation, it was found that plants can save up to 44,158 MWh of the energy consumption which is 47% from the total electricity consumption with a 17% reduction in the total utility bills and that about 2.5 million dollars cost savings after reviewing the currently facilitated energy system. Additionally, an average of five years' payback period resulted in most energy-saving recommendations. A vast potential of greenhouse gas emissions can be reduced with a total range reduction between 13 to 35 million kg of CO 2 based on the speed reduction percentage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot Residential Deep Energy Retrofits and the PNNL Lab Homes

This report summarizes research investigating the technical and economic feasibility of several pilot deep energy retrofits, or retrofits that save 30% to 50% or more on a whole-house basis while increasing comfort, durability, combustion safety, and indoor air quality. The work is being conducted for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. As part of the overall program, Pacific Northwest National Laboratory (PNNL) researchers are collecting and analyzing a comprehensive dataset that describes pre- and post-retrofit energy consumption, retrofit measure cost, health and comfort impacts, and other pertinent information for each home participating in the study. The research and data collection protocol includes recruitment of candidate residences, a thorough test-in audit, home energy modeling, and generation of retrofit measure recommendations, implementation of the measures, test-out, and continued evaluation. On some homes, more detailed data will be collected to disaggregate energy-consumption information. This multi-year effort began in October 2010. To date, the PNNL team has performed test-in audits on 51 homes in the marine, cold, and hot-humid climate zones, and completed 3 retrofits in Texas, 10 in Florida, and 2 in the Pacific Northwest. Two of the retrofits are anticipated to save 50% or more in energy bills and the others - savings are in the 30% to 40% range. Fourteen other retrofits are under way in the three climate zones. Metering equipment has been installed in seven of these retrofits - three in Texas, three in Florida, and one in the Pacific Northwest. This report is an interim update, providing information on the research protocol and status of the PNNL deep energy retrofit project as of December, 2011. The report also presents key findings and lessons learned, based on the body of work to date. In addition, the report summarizes the status of the PNNL Lab Homes that are new manufactured homes procured with minimal energy-efficiency specifications typical of existing homes in the region, and sited on the PNNL campus. The Lab Homes serve as a flexible test facility (the first of its kind in the Pacific Northwest) to rapidly evaluate energy-efficient and grid-smart technologies that are applicable to residential construction.

54 ENVIRONMENTAL SCIENCES↗

Energy Efficiency Improvements to Wundar Hall, a Historic Building on the Concordia Campus, Milwaukee, Wisconsin

The Forest County Potawatomi Community (FCPC or Community) implemented energy efficiency improvements to revitalize Wundar Hall, a 34,000 square foot (SF) building that was formerly used as a dormitory and is listed on the National Registry of Historic Places, into an office building. Wundar Hall is the first of many architecturally and historically significant buildings that the Community hopes to renovate at the former Concordia College campus, property on the near west side of Milwaukee that was taken into trust for the Community by the United States on July 10, 1990 (collectively, the Concordia Trust Property). As part of this project, which was conducted with assistance from the Department of Energy's Tribal Energy Program (TEP), the Community updated and/or replaced the building envelope, mechanical systems, the plumbing system, the electrical infrastructure, and building control systems. The project is expected to reduce the building's natural gas consumption by 58% and the electricity consumption by 55%. In addition, the project was designed to act as a catalyst to further renovation of the Concordia Trust Property and the neighborhood. The City of Milwaukee has identified redevelopment of the Concordia Trust Property as a Catalytic Project for revitalizing the near west side. The Tribe envisions a revitalized, mixed-use campus of community services, education, and economic development—providing services to the Indian community and jobs to the neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Feasibility of Renewable Energy Development and Energy Efficiency Deployment on Tribal Lands

The Keweenaw Bay Indian Community (KBIC) is committed to preserving our natural environment and reducing the amount of fossil fuels consumed while developing "green" business manufacturing jobs on tribal lands. The Tribe's Comprehensive Strategic Plan seeks to diversify the Tribal Economy through the creation of alternative energy businesses, such as wind, solar and bio-mass facilities while protecting the waters of Lake Superior, tribal inland lakes and streams. In addition, the Community desired to utilize clean/green energy resources to promote the self-sufficiency of the Tribal Nation. The objective of the study is to preserve our environment and maintain our cultural goals of using the resources of the land wisely. To reduce our consumption of fossil fuels, mercury and carbon dioxide emissions, which harm our water and land; we have decided to evaluate the opportunities of utilizing wind power. Preliminary projections show that we may eliminate pollution from our land in a cost effective manner. This study will evaluate wind capacity and our current energy consumption while projecting the feasibility of converting to wind power for operations at our major facilities. This project will study the feasibility of wind power at two locations for the purpose of reducing the Tribe's reliance upon fossil fuels and creating business opportunities, jobs and revenue for the community.

17 WIND ENERGY↗

SWEIS Yearbook 2011: Comparison of 2011 Data to Projections of the Site-Wide Environmental Impact Statement for Continued Operation of the Los Alamos National Laboratory

Los Alamos National Laboratory (LANL) operations data for CY 2011 mostly fell within the 2008 SWEIS projections. Operation levels for four LANL facilities exceeded the 2008 SWEIS capability projections – Los Alamos Neutron Science Center (LANSCE), Solid Radioactive and Chemical Waste (SRCW), Materials Science Laboratory (MSL) and Radiochemistry Facilities. However, none of these capability increases caused exceedances in waste generation, radioactive air emissions, or NPDES discharge. Several facilities exceeded the SWEIS levels for waste generation quantities; however, all were one-time, non-routine events that do not reflect the day-to-day operations of the Laboratory. In addition, total site-wide waste generation quantities were below SWEIS projections for all waste types, reflecting the overall levels of operations at both the Key and Non-Key Facilities. Although gas and electricity consumption have remained within the 2008 SWEIS limits for utilities, water consumption exceeded the 2008 SWEIS projections by 10 million gallons in CY 2011.

Energy Conservation, Consumption, & Utilization(32↗

Energy Efficiency Through Lighting Upgrades

Lighting upgrades including neon to LED, incandescent to CFL's and T-12 to T-8 and T-5's were completed through this grant. A total of 16 Chickasaw nation facilities decreased their carbon footprint because of these grant funds. Calculations used were based on comparing the energy usage from the previous year's average and the current energy usage. For facilities without a full year's set of energy bills, the month after installation was compared to the same month from the previous year. Overall, the effect the lighting change-outs had for the gaming centers and casinos far exceeded expectations. For the Madill Gaming Center; both an interior and exterior upgrade was performed which resulted in a 31% decrease in energy consumption. This same reduction was seen in every facility that participated in the grant. Just by simply changing out light bulbs to newer energy efficient equivalents, a decrease in energy usage can be achieved and this was validated by the return on investment seen at Chickasaw Nation facilities. Along with the technical project tasks were awareness sessions presented at Chickasaw Head Starts. The positive message of environmental stewardship was passed down to head start students and passed along to Chickasaw employees. Excitement was created in those that learned what they could do to help reduce their energy bills and many followed through and took the idea home. For a fairy low cost, the general public can also use this technique to lower their energy consumption both at home and at work. Although the idea behind the project was somewhat simple, true benefits have been gained through environmental awareness and reductions of energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗