Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Solar concentrator protective system

A mechanism that blocks concentrated sunlight from reaching a receiver, in the event of a tracking failure or loss of coolant is described. Sunlight is normally concentrated by a dish reflector onto the opening of a receiver. A faceplate surrounds the opening, and coolant carrying tubes, line the receiver. If the concentrated sunlight wanders so it begins to fall on the faceplate, then the sunlight will melt a portion of a fuse wire portion will break. The wire is attached to a flange on a shutter frame, and breaking of the fuse wire allows the frame to fall. Normally, the shutter frame supports shutter elements that are held open by cam followers that bear against cams.

Selcuk, M. K.↗

Concentrator Development

During the years of technology development by the Parabolic Dish program, the problems peculiar to tracking dishes have been explored in depth with particular emphasis on economics. Starting with the Precursor Concentrator, testing techniques and apparatus such as calorimeters and the flux mapper were developed. At the same time, mirrors were developed to have a long operating life as well as high performance. Commercially available equipment was evaluated as well. Building on all these elements, the Test Bed Concentrators were designed and built. With a peak intensity in the focal plane of over 17,500 suns and an average concentrator ratio over 3000 on an eight inch diameter aperture, they have proven to be the work horses of the technology. With a readily adjustable mirror array, they have proved to be an essential tool in the development of dish components, receivers, heat transport systems, instrumentation, controls, engines, and materials - all necessary to cost effective modules and plants. Utilizing the lessons learned from this technology, most cost effective systems were designed. These included Parabolic Dish Number 1 (PDC-1) and PDC-2 currently in final design by Acurex Corporation. Even more advanced concepts are being worked on, such as the Cassegranian systems by BDM Corporation.

Owen, W. A.↗

Sensitivity of airborne fluorosensor measurements to linear vertical gradients in chlorophyll concentration

A semianalytic Monte Carlo radiative transfer simulation model for airborne laser fluorosensors has been extended to investigate the effects of inhomogeneities in the vertical distribution of phytoplankton concentrations in clear seawater. Simulation results for linearly varying step concentrations of chlorophyll are presented. The results indicate that statistically significant differences can be seen under certain conditions in the water Raman-normalized fluorescence signals between nonhomogeneous and homogeneous cases. A statistical test has been used to establish ranges of surface concentrations and/or verticl gradients in which calibration by surface samples would by inappropriate, and the results are discussed.

Venable, D. D.↗

The effect of concentrator field layout on the performance of point-focus distributed receiver systems

The effect of concentrator field layout on the technical-economic performance of a point-focusing distributed receiver (PFDR) solar thermal power plant is presented. The plant design is based on the small community prototype system currently under development for JPL/DOE; parabolic dish concentrators are employed, and small heat engines are used to generate electricity at each dish. The effect of field size, array proportions, dish-to-dish spacing and packing fraction (concentrator-land area ratio) are presented for typical PFDR layouts. Economic analyses are carried out to determine optimum packing fraction as a function of site cost.

Pons, R. L.↗

Nebulization Reflux Concentrator

Nebulization reflux concentrator extracts and concentrates trace quantities of water-soluble gases for subsequent chemical analysis. Hydrophobic membrane and nebulizing nozzles form scrubber for removing trace quantities of soluble gases or other contaminants from atmosphere. Although hydrophobic membrane virtually blocks all transport of droplets, it offers little resistance to gas flow; hence, device permits relatively large volumes of gas scrubbed efficiently with very small volumes of liquid. This means analyzable quantities of contaminants concentrate in extracting solutions in much shorter times than with conventional techniques.

Cofer, Wesley R., III↗

Concentrator optical characterization using computer mathematical modelling and point source testing

The optical characteristics of a paraboloidal solar concentrator are analyzed using the intercept factor curve (a format for image data) to describe the results of a mathematical model and to represent reduced data from experimental testing. This procedure makes it possible not only to test an assembled concentrator, but also to evaluate single optical panels or to conduct non-solar tests of an assembled concentrator. The use of three-dimensional ray tracing computer programs to calculate the mathematical model is described. These ray tracing programs can include any type of optical configuration from simple paraboloids to array of spherical facets and can be adapted to microcomputers or larger computers, which can graphically display real-time comparison of calculated and measured data.

Dennison, E. W.↗

Evaluation of atmospheric particulate concentrations derived from analysis of ratio Thematic Mapper data

An approach for atmospheric particulate concentration evaluation above urban areas using ratio Thematic Mapper (TM) data is discussed. October 25, 1982 TM data over Chicago, IL are analyzed using TM band ratios of 1/2, 1/3, 1/4, 1/5, and 1/6 and particulate concentration estimates derived from TM ratios are tested over low reflective turbid water sites and highly reflective concrete highways. From analysis of the data it is evident that for water, the pattern of increasing particulate concentration is associated with decreasing ratio values in all band combinations used. Over concrete features, the TM band 1/4 ratio values follow the predicted pattern, while the TM band 1/6 has ratios which are reversed from anticipated values.

Carnahan, W. H.↗

Performance of Hughes GaAs concentrator cells under 1-MeV electron irradiation

Several Hughes gallium arsenide (GaAs) concentrator cells were exposed to 1-MeV electrons at fluences up to 1x10 to the 15th power electrons/sq cm. Performance data were taken after several fluences, at two temperatures, and at concentration levels from 1 to approx. 150x AMO. Data at 1 sun and 25 deg C were taken with an X-25 xenon-lamp solar simulator. Data at concentration were taken using a pulsed solar simulator with the assumption of a linear relationship between short-circuit current and irradiance. The cells are 5 by 5 mm with a 4-mm diameter illuminated area.

Curtis, H. B.↗

Preliminary results of measurements by automated probes Vega 1 and 2 or particle concentration in clouds of Venus at heights 47-63 KM

Results of the preliminary processing of the Vega 1 and 2 descender data on the cloud layer structure of the Venusian atmosphere are discussed. A photoelectric counter for aerosol particles is described together with its optical and pneumatic circuits and operation algorithm. Vertical profiles of concentrations of particles with a diameter of 0.4 microns agree quantitatively with the Pioneer-Venus and Venera 9 and 10 data. Concentrations of these particles are: in the B layer, up to 190/cu cm; in the C layer, up to 10/cu cm; and in the D layer, up to 130/cu cm. Layers have sharp boundaries with a significant vertical heterogeneity of the aerosol concentration field inside them.

Zhulanov, Y. V.↗

Concentration distributions in cylindrical combustors

Experimental studies have been conducted with the aim to obtain a better understanding of the fluid dynamics of mixing in gas turbine combustors, and solid fuel ramjet combustors subject to spin. The present investigation represents a continuation of studies conducted by So et al. (1984). It is also concerned with the verification of some conclusions reported by Ahmed et al. (1984). Attention is given to the experimental facility and instrumentation, centerline concentration measurements, mean concentration profiles, and a comparison of concentration and axial velocity results in the case of swirling flow.

Ahmed, S. A.↗

KOH concentration effect on the cycle life of nickel-hydrogen cells

Effects of KOH concentration on the cycle life of a sintered-type nickel electrode were studied in a boiler plate nickel-hydrogen cell at 23 C using an accelerated 45-min cycle regime at 80 percent depth of discharge. The cycle life improved greatly as the KOH concentration decreased, although the initial capacity of the cell decreased slightly. The cycle life improved by a factor of two or more when the KOH concentration was reduced from 36 to 31 percent and by a similar factor from reductions of 31 to 26 percent. For many applications, this life improvement may outweigh the initial capacity decrease.

Lim, H. S.↗

Effect of silane concentration on the supersonic combustion of a silane/methane mixture

A series of direct connect combustor tests was conducted to determine the effect of silane concentration on the supersonic combustion characteristics of silane/methane mixtures. Shock tube ignition delay data indicated more than an order of magnitude reduction in ignition delay times for both 10 and 20 percent silane/methane mixtures as compared to methane. The ignition delay time of the 10 percent mixture was only a factor of 2.3 greater than that of the 20 percent mixture. Supersonic combustion tests were conducted with the fuel injected into a model scramjet combustor. The combustor was mounted at the exit of a Mach 2 nozzle and a hydrogen fired heater was used to provide a variation in test gas total temperature. Tests using the 20 percent silane/methane mixture indicated considerable combustion enhancement when compared to methane alone. This mixture had an autoignition total temperature of 1650 R. This autoignition temperature can be contrasted with 2330 R for hydrogen and 1350 R for a 20 percent silane/hydrogen mixture in similar hardware. Methane without the silane additive did not autoignite in this configuration at total temperatures as high as 3900 R, the maximum temperature at which tests were conducted. Supersonic combustion tests with the silane concentration reduced to 10 percent indicated little improvement in combustion performance over pure methane. The addition of 20 percent silane to methane resulted in a pyrophoric fuel with good supersonic combustion performance. Reducing the silane concentration below this level, however, yielded a less pyrophoric fuel that exhibited poor supersonic combustion performance.

Northam, G. B.↗

The determination of the global average OH concentration using a deuteroethane tracer

It is proposed to measure the decreasing global concentration of an OH reactive isotopic tracer, G sub 2 D sub 6, after its introduction into the troposphere in a manner to facilitate uniform global mixing. Analyses at the level of 2 x 10 to the -19th power fraction, corresponding to one kg uniformly distributed globally, should be possible by a combination of cryogenic absorption techniques to separate ethane from air and high sensitivity isotopic analysis of ethane by mass spectrometry. Aliquots of C sub 2 D sub 6 totaling one kg would be introduced to numerous southern and northern latitudes over a 10 day period in order to achieve a uniform global concentration within 3 to 6 months by the normal atmospheric circulation. Then samples of air of 1000 l (STP) would be collected periodically at a tropical and temperate zone location in each hemisphere and spiked with a known amount of another isotopic species of ethane, C-13 sub 2 H sub 6, at the level of 10 to the -11th power mole fraction. After separation of the ethanes from air, the absolute concentration of C sub 2 D sub 6 would be analyzed using the Argonne 100-inch radius mass spectrometer.

Stevens, Charles M.↗

Elastic-plastic stress concentrations around crack-like notches in continuous fiber reinforced metal matrix composites

Continuous fiber silicon-carbide/aluminum composite laminates with slits were tested statically to failure. Five different layups were examined: (0) sub 8, (0 sub 2/ + or - 45) sub s, (0/90) sub 2s), (0/ + or - 45/90 sub s), and (+ or - 45) sub 2s. Either a 9.5 or a 19 mm slit was machined in the center of each specimen. The strain distribution ahead of the slit tip was found experimentally with a series of strain gages bonded ahead of the slit tip. A three-dimensional finite element program (PAFAC) was used to predict the strain distribution ahead of the slit tip for several layups. For all layups, except the (0) sub 8, the yielding of the metal matrix caused the fiber stress concentration factor to increase with increasing load. This is contrary to the behavior seen in homogeneous materials where yielding causes the stress concentration to drop. For the (0) sub 8 laminate, yielding of the matrix caused a decrease in the fiber stress concentration. The finite element analysis predicted these trends correctly.

Johnson, W. S.↗

Development of an advanced photovoltaic concentrator system for space applications

Recent studies indicate that significant increases in system performance (increased efficiency and reduced system mass) are possible for high power space based systems by incorporating technological developments with photovoltaic power systems. The Advanced Photovoltaic Concentrator Program is an effort to take advantage of recent advancements in refractive optical elements. By using a domed Fresnel lens concentrator and a prismatic cell cover, to eliminate metallization losses, dramatic reductions in the required area and mass over current space photovoltaic systems are possible. The advanced concentrator concept also has significant advantages when compared to solar dynamic Organic Rankine Cycle power systems in Low Earth Orbit applications where energy storage is required. The program is currently involved in the selection of a material for the optical element that will survive the space environment and a demonstration of the system performance of the panel design.

Piszczor, Michael F., Jr.↗

Concentration of carbon dioxide by a high-temperature electrochemical membrane cell

The performance of a molten carbonate carbon dioxide concentrator (MCCDC) cell, as a device for removal of CO2 from manned spacecraft cabins without fuel expenditure, is investigated. The test system consists of an electrochemical cell (with an Li2CO3-38 mol pct K2CO3 membrane contained in a LiAlO2 matrix), a furnace, and a flow IR analyzer for monitoring CO2. Operation of the MCCDC-driven cell was found to be suitable for the task of CO2 removal: the cell performed at extremely low CO2 partial pressures (at or above 0.1 mm Hg); cathode CO2 efficiencies of 97 percent were achieved with 0.25 CO2 inlet concentration at 19 mA sq cm, at temperatures near 873 K. Anode concentrations of up to 5.8 percent were obtained. Simple cathode and anode performance equations applied to correlate cell performance agreed well with those measured experimentally. A flow diagram for the process is included.

Kang, M. P.↗

Effects of varying environmental parameters on trace contaminant concentrations in the NASA Space Station Reference Configuration

An evaluation is made of the NASA Space Station Reference Configuration trace contaminant production and depletion level effects of CO2, O2, humidity, temperature, and pressure variations, on the basis of a computer model of the Reference Configuration's chemical reactions and physical processes as functions of time. The effects of changes in the initial concentrations of such contaminants as nonmethane hydrocarbons and nitrogen oxides are also examined, and these are found to result in more significant changes in the concentration levels of trace contaminants than pressure and humidity variations. O2 and CO2 changes are found to have negligible effects on trace contaminant concentrations.

Brewer, Dana A.↗

Multisensor comparison of ice concentration estimates in the marginal ice zone

Aircraft remote sensing data collected during the 1984 summer Marginal Ice Zone Experiment in the Fram Strait are used to compare ice concentration estimates derived from synthetic aperture radar (SAR) imagery, passive microwave imagery at several frequencies, aerial photography, and spectral photometer data. The comparison is carried out not only to evaluate SAR performance against more established techniques but also to investigate how ice surface conditions, imaging geometry, and choice of algorithm parameters affect estimates made by each sensor.Active and passive microwave sensor estimates of ice concentration derived using similar algorithms show an rms difference of 13 percent. Agreement between each microwave sensor and near-simultaneous aerial photography is approximately the same (14 percent). The availability of high-resolution microwave imagery makes it possible to ascribe the discrepancies in the concentration estimates to variations in ice surface signatures in the scene.

Burns, B. A.↗