Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Sky Residual Correction

The near-infrared is populated by numerous emission lines radiated from the Earth’s atmosphere, and these emission lines are often several orders of magnitude brighter in intensity than the typical astrophysical science target. The subtraction of these emission lines, sky subtraction, can create large systematic errors in ground-based astronomical spectra effectively limiting the number of usable resolution elements. A more effective sky subtraction, and the reduction of the systematic errors due to the sky subtraction process, is a major hurdle which ground-based astronomy must overcome to increase the amount of usable spectrum, and to be able to observe fainter scientific targets. Large high-quality data sets such as the Sloan Digital Sky Survey (SDSS) in themselves present opportunities for a reduction of the systematic sky subtraction errors through self-calibration. The sky residual correction method of Wild and Hewett is one such self-calibration technique which uses principal component analysis to reduce the systematic sky residual errors present in SDSS spectra. We apply sky residual corrections to the SDSS, Baryon Oscillation Spectroscopic Survey, and Apache Point Observatory Galactic Evolution Experiment data sets to optimize the number of subtraction components, and to quantify the reduction of the systematic errors in the science spectra. Finally as a proof of concept we use the sky-residual-corrected SDSS luminous red galaxy spectra to search for gravitationally lensed emission line Galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

An F1 Schmidt satellite camera and the methods of plate measurement and reduction

The f1 Hewitt camera is a field flattened Schmidt system of 60cm aperture. The salient features of this equipment are briefly described. Details of the methods of plate measurement are then given. The plate reduction is carried out in two stages. The plate is first calibrated using the photogrammetric method. The formulae usually quoted have been extended to take account of the large distortion introduced by the field flattening lens. In the second stage, the satellite measurements are reduced to satellite positions corrected for refraction, aberration, and when necessary, phase.

Hewitt, J.↗

High Accuracy In-Flight Wavelength Calibration of Imaging Spectrometry Data

Accurate wavelength calibration of imaging spectrometer data is essential if proper atmospheric transmission corrections are to be made to obtain apparent surface reflectance. Accuracies of 0.1 nm are necessary for a 10 nm-sampling instrument in order to match the slopes of the deep atmospheric water vapor features that dominate the 0.7-2.3 micrometer regions. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is calibrated in the laboratory to determine the wavelength position and full-width-half-maximum (FWHM) response for each of the 224 channels. The accuracies are limited by the quality of the monochromator used as a source. The accuracies vary from plus or minus to plus or minus 1.5 nm depending on the wavelength region, in general decreasing with increasing wavelength. Green et al. make corrections to the wavelength calibrations by using the known positions of 14 atmospheric absorption features throughout the 0.4-2.5 micrometer wavelength region. These features, having varying width and intensity, were matched to the MODTRAN model with a non-linear least squares fitting algorithm. A complete calibration was developed for all 224 channels by interpolation. Instrument calibration cannot be assumed to be stable to 0.1 nm over a flight season given the rigors of thermal cycling and launch and landing loads. The upcoming sensor HYDICE will require a means for in-flight spectral calibration of each scene because the calibration is both temperature and pressure sensitive. In addition, any sensor using a two-dimensional array has the potential for systematic wavelength shifts as a function of cross-track position, commonly called 'smile'. Therefore, a rapid means for calibrating complete images will be required. The following describes a method for determining instrument wavelength calibration using atmospheric absorption features that is efficient enough to be used for entire images on workstations. This study shows the effect of the surface reflectance on the calibration accuracy and the calibration history for the AVIRIS B spectrometer over the 1992 flight season.

Goetz, Alexander F. H.↗

Conservative self-force correction to the innermost stable circular orbit: Comparison with multiple post-Newtonian-based methods

Barack and Sago [Phys. Rev. Lett. 102, 191101 (2009)] have recently computed the shift of the innermost stable circular orbit (ISCO) of the Schwarzschild spacetime due to the conservative self-force that arises from the finite-mass of an orbiting test-particle. This calculation of the ISCO shift is one of the first concrete results of the self-force program, and provides an exact (fully relativistic) point of comparison with approximate post-Newtonian (PN) computations of the ISCO. Here this exact ISCO shift is compared with nearly all known PN-based methods. These include both 'nonresummed' and 'resummed' approaches (the latter reproduce the test-particle limit by construction). The best agreement with the exact (Barack-Sago) result is found when the pseudo-4PN coefficient of the effective-one-body (EOB) metric is fit to numerical relativity simulations. However, if one considers uncalibrated methods based only on the currently known 3PN-order conservative dynamics, the best agreement is found from the gauge-invariant ISCO condition of Blanchet and Iyer [Classical Quantum Gravity 20, 755 (2003)], which relies only on the (nonresummed) 3PN equations of motion. This method reproduces the exact test-particle limit without any resummation. A comparison of PN methods with the ISCO in the equal-mass case (computed via sequences of numerical relativity initial-data sets) is also performed. Here a (different) nonresummed method also performs very well (as was previously shown). These results suggest that the EOB approach - while exactly incorporating the conservative test-particle dynamics and having several other important advantages - does not (in the absence of calibration) incorporate conservative self-force effects more accurately than standard PN methods. I also consider how the conservative self-force ISCO shift, combined in some cases with numerical relativity computations of the ISCO, can be used to constrain our knowledge of (1) the EOB effective metric, (2) phenomenological inspiral-merger-ringdown templates, and (3) 4PN- and 5PN-order terms in the PN orbital energy. These constraints could help in constructing better gravitational-wave templates. Lastly, I suggest a new method to calibrate unknown PN terms in inspiral templates using numerical-relativity calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VALIDATION, VERIFICATION, AND CALIBRATION THROUGH A CAUSAL LENS

This paper presents an alternative method based on causal inference to perform validation, verification, and calibration of simulation models. While classical validation and verification approaches focus on the identification of the associations between data elements using statistical and machine learning methods, the novel methods in this paper focus instead on the identification of causal relationships between data elements. Statistical and machine learning-based approaches are strictly data-driven, meaning that they provide quantitative comparison measures between datasets without explicitly considering the hypotheses behind them. This can lead to the erroneous conclusion that, if two data sets are close enough, then the models that generated them are similar. In addition, when experimental and simulated data differ to an extent that fails to meet the acceptance criteria, calibration techniques are used to tweak simulation model parameters to reduce the gap between the two types of data. This produces the false expectation that a simulation model will match reality. The methods presented in this paper move away from these strictly data-driven methods for validation and calibration toward more robust, model-driven methods based on causal inference. Causal inference aims to identify the possible mechanisms that might have generated data. Thus, this analysis targets the prediction of the effects when one (or more) of the identified mechanisms are altered. There are many approaches to identify, quantify and illustrate causal relationships. For the scope of this paper, directed graphs are employed as causal models. If the directed graph lacks cycles it is known as a directed acyclic graph (DAG). A node in such a graph represents an observed data element while a directed edge connecting two nodes represents a causal relationship between two variables. The developed causal methods are designed to extract causal models from simulation models and from experimental data. Causal models capture the causal relationships between data elements (e.g., simulated and experimental data). In this context, validation and verification are performed by comparing causal models. The proposed approach does not only inform system analysts on how a simulation model matches real-world data, but also identifies elements of the simulation model that should be revised when discrepancies between simulation and experimental data are observed. Through these causal methods, analysts have a means to identify the portion of the model equation(s) that are behind an edge connecting two variables. Hence, once the structural differences between causal models have been determined, model calibration can occur by changing only those model parameters that impact the identified causal relationships.

97 MATHEMATICS AND COMPUTING↗

Auto-calibrated scanning-angle prism-type total internal reflection microscopy for nanometer-precision axial position determination and optional variable-illumination-depth pseudo total internal reflection microscopy

A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.

36 MATERIALS SCIENCE↗

SU-E-J-122: The CBCT Dose Calculation Using a Patient Specific CBCT Number to Mass Density Conversion Curve Based On a Novel Image Registration and Organ Mapping Method in Head-And-Neck Radiation Therapy

Purpose: To develop a CBCT HU correction method using a patient specific HU to mass density conversion curve based on a novel image registration and organ mapping method for head-and-neck radiation therapy. Methods: There are three steps to generate a patient specific CBCT HU to mass density conversion curve. First, we developed a novel robust image registration method based on sparseness analysis to register the planning CT (PCT) and the CBCT. Second, a novel organ mapping method was developed to transfer the organs at risk (OAR) contours from the PCT to the CBCT and corresponding mean HU values of each OAR were measured in both the PCT and CBCT volumes. Third, a set of PCT and CBCT HU to mass density conversion curves were created based on the mean HU values of OARs and the corresponding mass density of the OAR in the PCT. Then, we compared our proposed conversion curve with the traditional Catphan phantom based CBCT HU to mass density calibration curve. Both curves were input into the treatment planning system (TPS) for dose calculation. Last, the PTV and OAR doses, DVH and dose distributions of CBCT plans are compared to the original treatment plan. Results: One head-and-neck cases which contained a pair of PCT and CBCT was used. The dose differences between the PCT and CBCT plans using the proposed method are −1.33% for the mean PTV, 0.06% for PTV D95%, and −0.56% for the left neck. The dose differences between plans of PCT and CBCT corrected using the CATPhan based method are −4.39% for mean PTV, 4.07% for PTV D95%, and −2.01% for the left neck. Conclusion: The proposed CBCT HU correction method achieves better agreement with the original treatment plan compared to the traditional CATPhan based calibration method.

60 APPLIED LIFE SCIENCES↗

Mapping variations of redshift distributions with probability integral transforms

We present a method for mapping variations between probability distribution functions and apply this method within the context of measuring galaxy redshift distributions from imaging survey data. This method, which we name PITPZ for the probability integral transformations it relies on, uses a difference in curves between distribution functions in an ensemble as a transformation to apply to another distribution function, thus transferring the variation in the ensemble to the latter distribution function. This procedure is broadly applicable to the problem of uncertainty propagation. In the context of redshift distributions, for example, the uncertainty contribution due to certain effects can be studied effectively only in simulations, thus necessitating a transfer of variation measured in simulations to the redshift distributions measured from data. We illustrate the use of PITPZ by using the method to propagate photometric calibration uncertainty to redshift distributions of the Dark Energy Survey Year 3 weak lensing source galaxies. For this test case, we find that PITPZ yields a lensing amplitude uncertainty estimate due to photometric calibration error within 1 per cent of the truth, compared to as much as a 30 per cent underestimate when using traditional methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep Convective Cloud Calibration Sensitivity Studies in Support of Radiometrically Scaling GEO Imagers With VIIRS

The NASA CERES SYN1deg product provides the scientific community regional hourly TOA and surface broadband fluxes and clouds. For consistent geostationary (GEO) derived fluxes and clouds the GEO imagers are radiometrically scaled to the Aqua-MODIS calibration reference. The CERES project utilizes GEO and MODIS analogous channel coincident, collocated, and co-angled radiance pairs as the primary method to inter-calibrate the GEO imagers. Deep convective clouds (DCC) are bright tropical, near Lambertian, top of atmosphere pseudo invariant Earth targets that do not rely on coincident radiance pairs to radiometrically scale sensors to a common calibration reference. DCC pixels are identified by cold IR window channel brightness temperatures (BT). Successful DCC inter-calibration relies on sufficient sampling of comparable identified DCC pixels between sensors. The DCC identification thresholds, pixel resolution, local time, and geographical sampling should be consistent between sensors. Over 20 GEO imagers during the span of the CERES record have various visible and IR pixel resolutions. Unlike the MODIS and VIIRS imagers, where the visible and IR pixel resolutions are similar, the GEO visible pixel resolution is much finer than the IR pixel resolution. The study will examine the pixel resolution impact on the DCC calibration methodology. The resulting DCC calibration coefficients can be validated against the sensor pair calibration methodology. Accounting for the DCC calibration imager resolution differences will allow the CERES project to utilize the future CLARREO observations as the calibration reference for all GEO, MODIS, and VIIRS imagers across the CERES record.

Conor Haney↗

Solar Resource Calibration, Measurement, and Dissemination: Final Report FY 2016-FY 2018

The Solar Resource Calibration, Measurement, and Dissemination project supports the U.S. Department of Energy's Solar Energy Technologies Office (SETO) initiative to make solar energy cost-competitive with other forms of electricity by improving the tools and methods to measure and model solar radiation and therefore reduce uncertainty in predicting solar output and improve the bankability of solar projects. This project has three tasks that conduct research on advancing solar resource measurements and modeling: Task 1: Applied solar Radiation Measurements. Task 2: National Solar Radiation Data Base (NSRDB). Task 3: Knowledge Sharing. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory (SRRL) activities ensure traceable solar measurements throughout the United States that are essential for project feasibility, due diligence, financing, and plant operations. The SRRL houses NREL's Baseline Measurement System (BMS), which provides a platform for improving the accuracy of solar measurements through research to improve the calibration and characterization of instruments and enable the development of new measurement technology and standards. The platform contains a variety of instruments measuring solar radiation and other meteorological parameters. Following best practices, BMS instruments are calibrated to ensure traceability to the World Radiometric Reference in compliance with ISO/IEC 17025 accreditation requirements. The BMS data sets are quality-controlled and made publicly available through the Measurement and Instrumentation Data Center website. The NSRDB is the most accessed public database of solar irradiance and associated weather parameters for use in energy modeling. It supports SETO's goals of reducing barriers to high penetrations of solar technologies by providing easy access to high-quality, foundational data essential for innovative product development and downstream modeling through the NSRDB website. Data are currently available for the contiguous United States and beyond for 20 years covering 1998-2017. The Physical Solar Model (PSM) that underpins the current NSRDB data sets is a unique physics-based model that has been developed at NREL and has opened the door to the use of next-generation satellite data sets for solar resource assessment and forecasting. Through the American Society for Testing Materials (ASTM) International and other international standards organizations, NREL continues to provide leadership in the development of standards that are relevant to the measurement and modeling of solar radiation for solar energy applications. Standards developed cover the calibration method of pyrheliometers (direct normal irradiance measurements), pyranometers (global horizontal irradiance measurements), spectroradiometers, ultraviolet radiometers, correct field deployment of these instruments, spectral distribution reference tables for photovoltaic modeling, and transfer of indoor calibrations. Further, NREL leads the International Energy Agency (IEA) Photovoltaic Power Systems Programme Task 16: Subtask 1, which focuses on the evaluation of current and emerging resource assessment methodologies. NREL and the IEA updated the Best Practices Handbook for the Collection and Use of Solar Resource Data for Solar Energy Applications, which is widely used by the solar industry.

14 SOLAR ENERGY↗

Poster - 53: Improving inter-linac DMLC IMRT dose precision by fine tuning of MLC leaf calibration

Purpose: To develop a method to improve the inter-linac precision of DMLC IMRT dosimetry. Methods: The distance between opposing MLC leaf banks (“gap size”) can be finely tuned on Varian linacs. The dosimetric effect due to small deviations from the nominal gap size (“gap error”) was studied by introducing known errors for several DMLC sliding gap sizes, and for clinical plans based on the TG119 test cases. The plans were delivered on a single Varian linac and the relationship between gap error and the corresponding change in dose was measured. The plans were also delivered on eight Varian 2100 series linacs (at two institutions) in order to quantify the inter-linac variation in dose before and after fine tuning the MLC calibration. Results: The measured dose differences for each field agreed well with the predictions of LoSasso et al. Using the default MLC calibration, the variation in the physical MLC gap size was determined to be less than 0.4 mm between all linacs studied. The dose difference between the linacs with the largest and smallest physical gap was up to 5.4% (spinal cord region of the head and neck TG119 test case). This difference was reduced to 2.5% after fine tuning the MLC gap calibration. Conclusions: The inter-linac dose precision for DMLC IMRT on Varian linacs can be improved using a simple modification of the MLC calibration procedure that involves fine adjustment of the nominal gap size.

60 APPLIED LIFE SCIENCES↗

Calibration of multisite raters for prospective visual reads of amyloid PET scans

Abstract INTRODUCTION In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non‐elevated per tracer‐specific criteria. Inter‐ and intra‐rater agreement was assessed. RESULTS Inter‐rater agreement was substantial (Fleiss’κ = 0.78), with full consensus on 69% of scans. Inter‐rater reliability was substantial to perfect across tracers (Fleiss’κ = 0.70–0.87). Intra‐rater agreement was substantial to perfect (Cohen'sκ = 0.79‐1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.

Neurosciences & Neurology↗

Calibration of measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy using a contact detection method

An accurate experimental method is proposed for on-spot calibration of the measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy. One of the key techniques devised for this method is a reliable contact detection mechanism that detects the tip-surface contact instantly. At the contact instant, the oscillation amplitude of the tip deflection, converted to that of the deflection signal in laser reading through the measurement sensitivity, exactly equals to the distance between the sample surface and the cantilever base position. Therefore, the proposed method utilizes the recorded oscillation amplitude of the deflection signal and the base position of the cantilever at the contact instant for the measurement sensitivity calibration. Experimental apparatus along with various signal processing and control modules was realized to enable automatic and rapid acquisition of multiple sets of data, with which the calibration of a single dynamic mode could be completed in less than 1 s to suppress the effect of thermal drift and measurement noise. Calibration of the measurement sensitivities of the first and second dynamic modes of three micro-cantilevers having distinct geometries was successfully demonstrated. The dependence of the measurement sensitivity on laser spot location was also experimentally investigated. Finally, an experiment was performed to validate the calibrated measurement sensitivity of the second dynamic mode of a micro-cantilever.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray diffraction measurements and pressure determination in nanosecond compression of solids up to 600 GPa

X-ray diffraction measurements under laser-driven dynamic compression now allow us to investigate the atomic structure of matter at TPa pressures and thousands of degree temperatures with broad implications for condensed matter physics, planetary science and astronomy. Furthermore, pressure determination in these experiments often relies on velocimetry measurements coupled with modeling that requires accurate knowledge of the optical and thermo-mechanical properties of a window material, resulting in significant systematic uncertainty. Here we demonstrate different approach applicable to X-ray diffraction experiments under quasi-isentropic ramp-compression based on the use of in-situ pressure calibrants, similar to the methods often adopted in static-compression experiments with diamond anvil cells. Focusing on experiments using a diamond window, we discuss challenges and mitigation strategies for the novel approach. Our study, in addition to providing new structural information of 5 metals up to hundreds of GPa, provides validation to the currently used methods based on time-resolved measurement of the diamond free-surface velocity, and reveals that the use of in-situ calibrants enables a factor of four reduction in the pressure uncertainty in these experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

From Low-Cost Sensors to High-Quality Data: A Review of Challenges and Summary of Best Practices for Effectively Using Low-Cost Particulate Matter Mass Sensors

Low-cost sensors for particulate matter mass (PM) enable spatially dense, high temporal resolution measurements of air quality that traditional reference monitoring cannot. Low-cost PM sensors are especially beneficial in low and middle-income countries where few, if any, reference grade measurements exist and in areas where the concentration fields of air pollutants have significant spatial gradients. Unfortunately, low-cost PM sensors also come with a number of challenges that must be addressed if their data products are to be used for anything more than a qualitative characterization of air quality. The various PM sensors used in low-cost monitors are all subject to biases and calibration dependencies, corrections for which range from relatively straightforward(e.g. meteorology, age of sensor) to complex (e.g. aerosol source, composition, refractive index). The methods for correcting and calibrating these biases and dependencies that have been used in the literature likewise range from simple linear and quadratic models to complex machine learning algorithms. Here we review the needs and challenges when trying to get high-quality data from low-cost sensors. We also present a set of best practices to follow to obtain high-quality data from these low-cost sensors.

low-cost sensors↗

Leveraging Calibration Transfer Techniques for Remote Monitoring of Samarium and Europium in LiCl Using Laser-Induced Florescence Spectroscopy for Radioisotope Production Applications

Radioisotope production relies on complex chemical processes that must be performed in radiological hot cells or glove boxes because of the radioactive and otherwise hazardous materials being used. In these situations, optical sensors can provide real-time monitoring to users, which is unobtainable by more traditional methods. This study explores the use of calibration transfer methods to train a model on one instrument and date and then transfer it to another instrument of the same or different configuration on a different date. By performing laser-induced fluorescence measurements of Eu(III) and Sm(III) in 10 M LiCl over the course of 6 months using two disparate spectrometers and two different training sets, a strategy for calibrating and deploying models for online monitoring was established. Three transfer techniques were compared: direct standardization (DS), piecewise direct standardization (PDS), and external parameter orthogonalization (EPO). DS and PDS outperformed EPO for day-to-day transfers, and EPO was not effective for instrument-to-instrument transfers. Transferring the initial date’s full factorial model provided better prediction performance compared with retraining models the day of measurements using a D-optimal designed calibration set. For both day-to-day and instrument-to-instrument transfers, five Kennard–Stone selected samples were sufficient. Based on this choice, the initial-date, high-resolution spectrometer model was transferred to a lower-resolution, compact spectrometer 6 months later to monitor a simulated, real-time demonstration. Here, the combined predictions of the DS and PDS transferred models were able to accurately track the anticipated concentration profiles, maintaining root-mean-square error of prediction values below 10 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗