Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Window”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Novel Linac Structures For Low-Beta Ions And For Muons

Development of two innovative linacs is discussed. (1)High-efficiency normal-conducting accelerating structures for ions with beam velocities in the range of a few percent of the speed of light. Two existing accelerator technologies - the H-mode resonator cavities and transverse beam focusing by permanent-magnet quadrupoles (PMQ) - are merged to create efficient structures for light-ion beams of considerable currents. The inter-digital H-mode accelerator with PMQ focusing (IH-PMQ) has the shunt impedance 10-20 times higher than the standard drift-tube linac. Results of the combined 3-D modeling for an IH-PMQ accelerator tank - electromagnetic computations, beam-dynamics simulations, and thermal-stress analysis - are presented. H-PMQ structures following a short RFQ accelerator can be used in the front end of ion linacs or in stand-alone applications like a compact mobile deuteron-beam accelerator up to a few MeV. (2)A large-acceptance high-gradient linac for accelerating low-energy muons in a strong solenoidal magnetic field. When a proton beam hits a target, many low-energy pions are produced almost isotropically, in addition to a small number of high-energy pions in the forward direction. We propose to collect and accelerate copious muons created as the low-energy pions decay. The acceleration should bring muons to a kinetic energy of {approx}200 MeV in about 10 m, where both an ionization cooling of the muon beam and its further acceleration in a superconducting linac become feasible. One potential solution is a normal-conducting linac consisting of independently fed 0-mode RF cavities with wide apertures closed by thin metal windows or grids. The guiding magnetic field is provided by external superconducting solenoids. The cavity choice, overall linac design considerations, and simulation results of muon acceleration are presented. Potential applications range from basic research to homeland defense to industry and medicine.

43 PARTICLE ACCELERATORS↗

Compact Permanent Magnet Microwave-Driven Neutron Generator

Permanent magnet microwave-driven neutron generators have been developed at Lawrence Berkeley National Laboratory. The 2.45 GHz microwave signal is directly coupled into the plasma chamber via a microwave window. Plasma is confined in an axial magnetic field produced by the permanent magnets surrounding the plasma chamber. The source chamber is made of aluminum with a diameter of 4 cm and length of 5 cm. A stack of five alumina discs, which are 3 cm in diameter and total length of 3 cm, works as microwave window. Three permanent ring magnets are used to generate the axial magnetic field required for the microwave ion source. Both hydrogen and deuterium plasma have been successfully ignited. With 330W of microwave power, source chamber pressure of 5 mTorr, and an extraction aperture of 2 mm in diameter, the deuterium ion beam measured on the target was approximately 2.5 mA. Over 90% of the ions are atomic. With the ion source at ground potential and titanium target at -40 kV, the analysis of the activated gold foil and calibrated neutron dose monitor both indicated that roughly 10{sup 7} n/s of D-D neutrons have been produced. The D-D neutron yield can be easily scaled up to 10{sup 8} n/s when the titanium target is biased at -100 kV.

43 PARTICLE ACCELERATORS↗

A compact digital time differential perturbed angular correlation-spectrometer using field programmable gate arrays and various timestamp algorithms

A user-friendly fully digital time differential perturbed angular correlation (TDPAC)-spectrometer with six detectors and fast digitizers using field programmable gate arrays (FPGA) is described and performance data are given. The new spectrometer has an online data analysis feature, a compact size, and a time resolution such as conventional analog spectrometers. Its calculation intensive part was implemented inside the digitizer. This gives the possibility to change parameters (energy windows, constant fraction trigger delay) and see their influence immediately in the {gamma}-{gamma} correlation diagrams. Tests were performed which showed that the time resolution using a {sup 60}Co source with energy window set at 1.17 MeV and 1.33 MeV is 265 ps with LaBr{sub 3}(Ce) scintillators and 254 ps with BaF{sub 2} scintillators. A true constant fraction algorithm turned out to be slightly better than the constant fraction of amplitude method. The spectrometer performance was tested with a TDPAC measurement using a {sup 44}Ti in rutile source and a positron lifetime measurement using {sup 22}Na. The maximum possible data rate of the spectrometer is 1.1 x 10{sup 6} {gamma} quanta per detector and second.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of metal nano layer thickness on tunneling oxide and memory performance of core-shell iridium-oxide nanocrystals

The impact of iridium-oxide (IrO{sub x}) nano layer thickness on the tunneling oxide and memory performance of IrO{sub x} metal nanocrystals in an n-Si/SiO{sub 2}/Al{sub 2}O{sub 3}/IrO{sub x}/Al{sub 2}O{sub 3}/IrO{sub x} structure has been investigated. A thinner (1.5 nm) IrO{sub x} nano layer has shown better memory performance than that of a thicker one (2.5 nm). Core-shell IrO{sub x} nanocrystals with a small average diameter of 2.4 nm and a high density of {approx}2 x 10{sup 12}/cm{sup 2} have been observed by scanning transmission electron microscopy. The IrO{sub x} nanocrystals are confirmed by x-ray photoelectron spectroscopy. A large memory window of 3.0 V at a sweeping gate voltage of {+-}5 V and 7.2 V at a sweeping gate voltage of {+-} 8 V has been observed for the 1.5 nm-thick IrO{sub x} nano layer memory capacitors with a small equivalent oxide thickness of 8 nm. The electrons and holes are trapped in the core and annular regions of the IrO{sub x} nanocrystals, respectively, which is explained by Gibbs free energy. High electron and hole-trapping densities are found to be 1.5 x 10{sup 13}/cm{sup 2} and 2 x 10{sup 13}/cm{sup 2}, respectively, due to the small size and high-density of IrO{sub x} nanocrystals. Excellent program/erase endurance of >10{sup 6} cycles and good retention of 10{sup 4} s with a good memory window of >1.2 V under a small operation voltage of {+-} 5 V are obtained. A large memory size of >10 Tbit/sq. in. can be designed by using the IrO{sub x} nanocrystals. This study is not only important for the IrO{sub x} nanocrystal charge-trapping memory investigation but it will also help to design future metal nanocrystal flash memory.

36 MATERIALS SCIENCE↗

Phoswich scintillator for proton and gamma radiation of high energy

We present here a Phoswich scintillator design to achieve both high resolution gamma ray detection, and good efficiency for high energy protons. There are recent developments of new high resolution scintillator materials. Especially the LaBr3(Ce) and LaCl3(Ce) crystals have very good energy resolution in the order of 3% for 662 keV gamma radiation. In addition, these materials exhibit a very good light output (63 and 32 photons/keV respectively).A demonstrator detector in the form of an Al cylinder of 24 mm diameter and a total length of 80 mm with 2 mm wall thickness, containing a LaBr3(Ce) crystal of 20 mm diameter and 30 mm length directly coupled to a LaCl3(Ce) crystal of 50 mm length, and closed with a glass window of 5 mm, was delivered by Saint Gobain. To the glass window a Hamamatsu R5380 Photomultiplier tube (PMT) was coupled using silicon optical grease.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and operation of the wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source

The wide angular-range chopper spectrometer ARCS at the Spallation Neutron Source (SNS) is optimized to provide a high neutron flux at the sample position with a large solid angle of detector coverage. The instrument incorporates modern neutron instrumentation, such as an elliptically focused neutron guide, high speed magnetic bearing choppers, and a massive array of {sup 3}He linear position sensitive detectors. Novel features of the spectrometer include the use of a large gate valve between the sample and detector vacuum chambers and the placement of the detectors within the vacuum, both of which provide a window-free final flight path to minimize background scattering while allowing rapid changing of the sample and sample environment equipment. ARCS views the SNS decoupled ambient temperature water moderator, using neutrons with incident energy typically in the range from 15 to 1500 meV. This range, coupled with the large detector coverage, allows a wide variety of studies of excitations in condensed matter, such as lattice dynamics and magnetism, in both powder and single-crystal samples. Comparisons of early results to both analytical and Monte Carlo simulation of the instrument performance demonstrate that the instrument is operating as expected and its neutronic performance is understood. ARCS is currently in the SNS user program and continues to improve its scientific productivity by incorporating new instrumentation to increase the range of science covered and improve its effectiveness in data collection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion irradiation tolerance of graphene as studied by atomistic simulations

As impermeable to gas molecules and at the same time transparent to high-energy ions, graphene has been suggested as a window material for separating a high-vacuum ion beam system from targets kept at ambient conditions. However, accumulation of irradiation-induced damage in the graphene membrane may give rise to its mechanical failure. Using atomistic simulations, we demonstrate that irradiated graphene even with a high vacancy concentration does not show signs of such instability, indicating a considerable robustness of graphene windows. We further show that upper and lower estimates for the irradiation damage in graphene can be set using a simple model.

36 MATERIALS SCIENCE↗

Streaked x-ray spectrometer having a discrete selection of Bragg geometries for Omega

The streaked x-ray spectrometer (SXS) is used with streak cameras [D. H. Kalantar, P. M. Bell, R. L. Costa, B. A. Hammel, O. L. Landen, T. J. Orzechowski, J. D. Hares, and A. K. L. Dymoke-Bradshaw, in 22nd International Congress on High-Speed Photography and Photonics, edited by D. L. Paisley and A. M. Frank (SPIE, Bellingham, WA, 1997), Vol. 2869, p. 680] positioned with a ten-inch manipulator on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] and OMEGA EP [L. J. Waxer et al., Presented at CLEO/QELS 2008, San Jose, CA, 4-9 May 2008 (Paper JThB1)] for time-resolved, x-ray spectroscopy of laser-produced plasmas in the 1.4- to 20-keV photon-energy range. These experiments require measuring a portion of this photon-energy range to monitor a particular emission or absorption feature of interest. The SXS relies on a pinned mechanical reference system to create a discrete set of Bragg reflection geometries for a variety of crystals. A wide selection of spectral windows is achieved accurately and efficiently using this technique. It replaces the previous spectrometer designs that had a continuous Bragg angle adjustment and required a tedious alignment calibration procedure. The number of spectral windows needed for the SXS was determined by studying the spectral ranges selected by OMEGA users over the last decade. These selections are easily configured in the SXS using one of the 25 discrete Bragg reflection geometries and one of the six types of Bragg crystals, including two curved crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solving seismological problems using SGRAPH program: I-source parameters and hypocentral location

SGRAPH program is considered one of the seismological programs that maintain seismic data. SGRAPH is considered unique for being able to read a wide range of data formats and manipulate complementary tools in different seismological subjects in a stand-alone Windows-based application. SGRAPH efficiently performs the basic waveform analysis and solves advanced seismological problems. The graphical user interface (GUI) utilities and the Windows facilities such as, dialog boxes, menus, and toolbars simplified the user interaction with data. SGRAPH supported the common data formats like, SAC, SEED, GSE, ASCII, and Nanometrics Y-format, and others. It provides the facilities to solve many seismological problems with the built-in inversion and modeling tools. In this paper, I discuss some of the inversion tools built-in SGRAPH related to source parameters and hypocentral location estimation. Firstly, a description of the SGRAPH program is given discussing some of its features. Secondly, the inversion tools are applied to some selected events of the Dahshour earthquakes as an example of estimating the spectral and source parameters of local earthquakes. In addition, the hypocentral location of these events are estimated using the Hypoinverse 2000 program operated by SGRAPH.

58 GEOSCIENCES↗

A New Control System Software for SANS BATAN Spectrometer in Serpong, Indonesia

The original main control system of the 36 meter small‐angle neutron scattering (SANS) BATAN Spectrometer (SMARTer) has been replaced with the new ones due to the malfunction of the main computer. For that reason, a new control system software for handling all the control systems was also developed in order to put the spectrometer back in operation. The developed software is able to control the system such as rotation movement of six pinholes system, vertical movement of four neutron guide system with the total length of 16.5 m, two‐directional movement of a neutron beam stopper, forward‐backward movement of a 2D position sensitive detector (2D‐PSD) along 16.7 m, etc. A Visual Basic language program running on Windows operating system was employed to develop the software and it can be operated by other remote computers in the local area network. All device positions and command menu are displayed graphically in the main monitor or window and each device control can be executed by clicking the control button. Those advantages are necessary required for developing a new user‐friendly control system software. Finally, the new software has been tested for handling a complete SANS experiment and it works properly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charged electret deposition for the manipulation of high power microwave flashover delay times

A quasi-permanent charged electret is embedded into the radiation window of a high power microwave system. It was experimentally observed that the additional electrostatic field introduced by the electret alters the delay times associated with the development of plasma at the window surface, resulting from high power microwave excitation. The magnitudes of both the statistical and formative delay times are investigated in detail for different pressures. Experimental observations are related to calculated discharge parameters using known E/p dependent properties.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elimination of ghosting artifacts from wavelength-shifting fiber neutron detectors

Misassignment of neutron position (ghosting) produces artifacts, which have been observed in wavelength-shifting (WLS) fiber detectors developed for time-of-flight (TOF) neutron powder diffraction. In position-sensitive detectors (PSDs) with WLS fiber encoding, thermal and cold neutrons interact with a monolithic 6LiF/ZnS:Ag scintillator screen, and scintillation photons are generated and transported through the crossed fibers to photomultipliers (PMTs). The neutron position is determined by photon counts in PMTs within a preset time window. Ghosting occurs when neutrons hit the group boundaries of two neighboring PMTs for x-position multiplexing, which is modeled as resulting from a long travel length (about 3-5 mm) of a small number of scintillation photons. This model is supported by the change observed in aperture images when the threshold number for photon-pulses was adjusted for a neutron event determination. When the threshold number of photon-pulses was set above 10 for each PMT, the ghost peaks in the aperture images and TOF spectra of powder diffraction were strongly suppressed or completely eliminated, and the intrinsic background levels of the WLS detectors were significantly reduced. Our result indicates that WLS fiber detector is a promising alternative for 3He PSDs for neutron scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New tandem type ion source based on electron cyclotron resonance for universal source of synthesized ion beams

A new tandem type source has been constructed on the basis of electron cyclotron resonance (ECR) plasma for producing synthesized ion beams. We investigate feasibility and hope to realize the device which has wide range operation window in a single device to produce many kinds of ion beams based on ECR ion source (ECRIS). It is considered that ECR plasmas are necessary to be available to individual operations with different plasma parameters. Both of analysis of ion beams and investigation of plasma parameters are conducted on produced plasmas. We describe construction of the new tandem type ion source based on ECRIS with wide operation window for aiming at producing synthesized ion beams as this new source can be a universal source.

43 PARTICLE ACCELERATORS↗

A novel facility for 3D micro-irradiation of living cells in a controlled environment by MeV ions

We present a novel facility for micro-irradiation of living targets with ions from a 1.7 MV tandem accelerator. We show results using 1 MeV protons and 2 MeV He{sup 2+}. In contrast to common micro-irradiation facilities, which use electromagnetic or electrostatic focusing and specially designed vacuum windows, we employ a tapered glass capillary with a thin end window, made from polystyrene with a thickness of 1–2 μm, for ion focusing and extraction. The capillary is connected to a beamline tilted vertically by 45°, which allows for easy immersion of the extracted ions into liquid environment within a standard cell culture dish. An inverted microscope is used for simultaneously observing the samples as well as the capillary tip, while a stage-top incubator provides an appropriate environment for the samples. Furthermore, our setup allows to target volumes in cells within a μm{sup 3} resolution, while monitoring the target in real time during and after irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustical “transparency” induced by local resonance in Bragg bandgaps

We show that sound waves can resonantly transmit through Bragg bandgaps in an acoustical duct periodically attached with an array of Helmholtz resonators, forming within the normally forbidden band a transparency window with group velocity smaller than the normal speed of sound. The transparency occurs for the locally resonant frequency so much close to the Bragg one that both the local-resonance-induced bandgap and the Bragg one heavily overlap with each other. The phenomenon seems an acoustical analog of the well-known electromagnetically induced transparency by quantum interference. Different from the Fano-like interference explanation, we also provide a mechanism for the transparency window phenomenon which makes it possible to extend the phenomenon in general.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantification of residual stress from photonic signatures of fused silica

A commercially available grey-field polariscope (GFP) instrument for photoelastic examination is used to assess impact damage inflicted upon the outer-most pane of Space Shuttle windows made from fused silica. A method and apparatus for calibration of the stress-optic coefficient using four-point bending is discussed. The results are validated on known material (acrylic) and are found to agree with literature values to within 6%. The calibration procedure is then applied to fused-silica specimens and the stress-optic coefficient is determined to be 2.43 ± 0.54 × 10{sup −12} Pa{sup −1}. Fused silica specimens containing impacts artificially made at NASA’s Hypervelocity Impact Technology Facility (HIT-F), to simulate damage typical during space flight, are examined. The damage sites are cored from fused silica window carcasses and examined with the GFP. The calibrated GFP measurements of residual stress patterns surrounding the damage sites are presented.

42 ENGINEERING↗

X-ray source considerations in operation of digital detector arrays

Digital Detector Arrays (DDA) are increasingly replacing film in radiography applications. Standards exist for characterizing the performance of these detectors, and for using them in specific inspections. We have observed that the selection of the x-ray source to use with these detectors can also have a significant influence on the performance. We look at differences between standard, and micro-focus x-ray tubes, and end-window vs. side-window micro-focus tubes. We find that for best results, one must calibrate the DDA for the source settings used during an inspection. This is particularly true for variable-focus sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Phase retrieval method for analyzing single-phase displacement interferometry data

We present a phase retrieval method (PRM) for analyzing single-phase displacement interferometry measurements on rapidly changing velocity histories, including photon Doppler velocimetry (PDV). PRM identifies the peaks and valleys as well as zero-crossing points in a PDV time series, performs normalization and extracts point-by-point phase and thus velocity information. PRM does not require a wide time window as in sliding window Fourier transformation, and thus improves the effective temporal resolution. This method is implemented in analyzing PDV data obtained from gas gun experiments, and validated against simultaneous measurements with velocity interferometer system for any reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗