Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

Thermal-Structural Evaluation of TD Ni-20Cr Thermal Protection System Panels

The results of a thermal-structural test program to verify the performance of a metallic/radiative Thermal Protection System (TPS) under reentry conditions are presented. This TPS panel is suitable for multiple reentry, high L/D space vehicles, such as the NASA space shuttle, having surface temperatures up to 1200 C (2200 F). The TPS panel tested consists of a corrugation-stiffened, beaded-skin TD Ni-20Cr metallic heat shield backed by a flexible fibrous quartz and radiative shield insulative system. Test conditions simulated the critical heating and aerodynamic pressure environments expected during 100 repeated missions of a reentry vehicle. Temperatures were measured during each reentry cycle; heat-shield flatness surveys to measure permanent set of the metallic components were made every 10 cycles. The TPS panel, in spite of localized surface failures, performed its designated function.

Eidinoff, H. L.↗

Long Duration Life Test of Propylene Glycol Water Based Thermal Fluid Within Thermal Control Loop

Evaluations of thermal properties and resistance to microbial growth concluded that 50% Propylene Glycol (PG)-based fluid and 50% de-ionized water mixture was desirable for use as a fluid within a vehicle s thermal control loop. However, previous testing with a commercial mixture of PG and water containing phosphate corrosion inhibitors resulted in corrosion of aluminum within the test system and instability of the test fluid. This paper describes a follow-on long duration testing and analysis of 50% Propylene Glycol (PG)-based fluid and 50% de-ionized water mixture with inorganic corrosion inhibitors used in place of phosphates. The test evaluates the long-term fluid stability and resistance to microbial and chemical changes

Le, Hung↗

Thermal Analysis of Low Layer Density Multilayer Insulation Test Results

Investigation of the thermal performance of low layer density multilayer insulations is important for designing long-duration space exploration missions involving the storage of cryogenic propellants. Theoretical calculations show an analytical optimal layer density, as widely reported in the literature. However, the appropriate test data by which to evaluate these calculations have been only recently obtained. As part of a recent research project, NASA procured several multilayer insulation test coupons for calorimeter testing. These coupons were configured to allow for the layer density to be varied from 0.5 to 2.6 layer/mm. The coupon testing was completed using the cylindrical Cryostat-l00 apparatus by the Cryogenics Test Laboratory at Kennedy Space Center. The results show the properties of the insulation as a function of layer density for multiple points. Overlaying these new results with data from the literature reveals a minimum layer density; however, the value is higher than predicted. Additionally, the data show that the transition region between high vacuum and no vacuum is dependent on the spacing of the reflective layers. Historically this spacing has not been taken into account as thermal performance was calculated as a function of pressure and temperature only; however the recent testing shows that the data is dependent on the Knudsen number which takes into account pressure, temperature, and layer spacing. These results aid in the understanding of the performance parameters of MLI and help to complete the body of literature on the topic.

Johnson, Wesley L.↗

CATHARE calculations of Phenix ultimate natural convection test

The Phenix Sodium cooled Fast Reactor (SFR) started operation in 1973 and it was stopped in 2009. Before the reactor was definitively shutdown, in order to collect experimental data for code assessments in the frame of Generation IV an intensive program of ultimate tests was set up. Among these ultimate experiments, two thermal hydraulic tests were performed: an asymmetrical test consisting in a trip on one secondary pump and a natural convection test in the primary circuit. The natural convection test has been used for an international benchmark on system codes in the frame of the IAEA. The CATHARE code - initially developed for water cooled reactors and now extended for safety analyses for other kinds of reactors, including Sodium Fast Reactor - was used by CEA for this benchmark. The paper reminds briefly the Phenix reactor with the main physical parameters and the instrumentation used during the natural convection test. Main test results are also briefly reminded including the evolution of the core and the heat exchangers inlet and outlet temperatures, and some local temperature measurements. The main developments to perform CATHARE SFR computations and the strategy of system code assessment are presented. Then the CATHARE modelling of Phenix reactor is depicted and the various assumptions are pointed out. CATHARE encountered no problem to predict the initial nominal state. Afterwards, the whole transient scenario is calculated and CATHARE calculations are compared to the Phenix measurements. The global trend is rather well predicted by the CATHARE code. Nevertheless, due to complex flow phenomena occurring in large plena and components, the system code encountered physical limitations, leading to remaining discrepancies between code prediction and plant data. Various sensitivity calculations are presented and they bring partial answers. Additional analyses are in progress to understand more deeply the complex 3D phenomena involved during the different phases of the natural convection test. Additional work for coupling CATHARE system code and TRIO-U CFD code is in progress and will bring useful information to better understand the physical phenomena involved during the natural convection test and to improve system modeling for future SFR safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of Internal Insulation Thermal Performance

A test campaign was performed to build an SRM-insulation-material thermal-performance database using MSFC’s Solid Fuel Torch that could be leveraged to enhance understanding of the relationship between ablation rates and internal-environment parameters and improve insulation performance predictions. Seven hot-fire tests were performed along with data analysis that revealed the thermal performance differences among the tested materials. Functional Data Analysis was employed to create a model of material ablation rate as a function of six covariates. The relative importance of several environmental parameters was indicated, and the gaps in the operational space covered by the database were identified.

Ablation↗

Durability Testing of Commercial Ceramic Materials

Technical efforts by AlliedSignal Engines in DOE/NASA-funded project from February, 1978 through December, 1995 are reported in the fields ceramic materials for gas turbine engines and cyclic thermal durability testing. A total of 29 materials were evaluated in 40 cyclic oxidation exposure durability tests. Ceramic test bars were cyclically thermally exposed to a hot combustion environment at temperatures up to 1371 C (2500 F) for periods of up to 3500 hours, simulating conditions typically encountered by hot flowpath components in an automotive gas turbine engine. Before and after exposure, quarter-point flexure strength tests were performed on the specimens, and fractography examinations including scanning electron microscopy (SEM) were performed to determine failure origins.

Schienle, J. L.↗

Microthruster Propulsion for the Space Technology 7 (ST7) Technology Demonstration Mission

For future applications to precision formation flying missions, NASA's New Millennium Program is scheduled to test colloid micro-Newton thrusters (CMNTs) on the ST7 technology demonstration mission. These CMNTs are part of a disturbance reduction system (DRS) on the ESA SMART-2 Spacecraft or LISA Pathfinder. The goal of the ST7 DRS is to demonstrate technologies necessary to meet the nanometer precision positioning control requirements of the LISA mission. In order to achieve these goals, the CMNTs are required to demonstrate a thrust resolution of less than 0.1 micro-N and a thrust noise of less than 0.1 micro-N/[square root]Hz for thrust levels between 5 and 30 micro-N. Developed by Busek Co. with support from JPL in testing an design, the CMNT has been developed over the last four years into a flight-ready microthrust system. The development, validation testing, and flight unit production of the CMNTs are described. Development tests and analysis include preliminary wear tests, propellant loading process verification, flow testing, and performance verification. Validation and flight unit verification includes thermal and structural analysis, life testing, thermal and dynamic load testing, and performance verification. Final delivery of the units is planned in 2007 with and planned launch and flight demonstration 2009.

microthruster↗

Evaluation of high temperature structural adhesives for extended service, phase 4

The evaluation of three phenylquinoxaline polymers as high temperature structural adhesives is presented. These included an experimental crisskubjabke oiktner (X-PQ) and two experimental materials (PPQ-2501) and (PPQ-HC). Lap shear, crack extension, and climing drum peel specimens were fabricated from all three polymers, and tested after thermal, combined thermal/humidity, and stressed Skydrol exposure. All three polymers generally performed well as adhesives at initial test temperatures from 219K (-67 F) to 505K (450 F) and after humidity exposure. The 644K (700 F) cured test specimens exhibited superior Skydrol resistance and thermal stability at 505K (450 F) when compared to the 602K (625 F) cured test specimens.

Hendricks, C. L.↗

Production and testing of the powerboard for ATLAS ITk Strip barrel modules

The upgrade of the ATLAS ITk strips detector for HL-LHC will employ a custom PCB (powerboard) for on-module DC-DC conversion, HV switching, and monitoring. Production of about 14100 of such PCBs with high reliability is a big challenge. In this paper we will present the production procedure and quality control (QC) testing system for the powerboards to be installed on ITk Strip barrel modules. During production, about 150 powerboards will be produced every week. Each powerboard will need to pass QC tests before they are assembled to module. The QC tests include thermal cycling between -35 °C and 40 °C, soak test (continuous running of DC-DC converter at high load at 20 °C), and basic functionality and characterization electrical tests of the low voltage (LV), high voltage (HV), and monitoring functions of the powerboard. A custom QC test system is described, which is based on a reusable PCB (active board) with all testing circuits, a one-time powerboard carrier card, and a Z-turn SoC board which hosts and runs the testing program. The production procedure and QC test system has been tested with 400 powerboards during pre-production, and the system has been proven ready for production with the desired testing program, speed, safety, and cost. Performance and typical failures of powerboards observed during the QC test of pre-production powerboards is also presented.

47 OTHER INSTRUMENTATION↗

Tailoring Thermal and Mechanical Performance Through Multimaterial Laser Powder Directed Energy Deposition of Copper and 17-4PH Stainless Steel

This study investigates the additive manufacturing (AM) processing, microstructural evolution, and resulting mechanical and thermal properties of multimaterial components combining 17-4PH stainless steel and pure copper (Cu) fabricated via laser powder directed energy deposition (LP-DED). Conventional tooling steels exhibit limited thermal conductivity, significantly constraining production throughput in high-volume processes. Incorporating Cu, with its superior thermal conductivity, could significantly enhance tool performance, though Cu and steel present metallurgical incompatibilities when processed via AM. A systematic investigation was conducted across compositions ranging from 0 to 100 wt% Cu, revealing critical thresholds influencing solidification behavior, defect formation, microstructure, hardness, and thermal transport. Optical microscopy, electron backscatter diffraction (EBSD), hardness testing, and thermal conductivity measurements provided comprehensive process–structure–property correlations. Severe hot cracking occurred at low-Cu contents (6–25 wt%), aligning generally well with crack susceptibility modeling, with an unexpected discrepancy at 25 wt%. Porosity remained low (≥99% dense) throughout the compositional spectrum. EBSD analysis revealed a transformation from columnar martensitic structures at low-Cu contents to equiaxed FCC Cu-dominated structures at higher Cu concentrations, highlighting the complex microstructural transitions driven by Cu-induced changes in solidification and phase stability. Hardness decreased from 330 HV (pure 17-4PH) to 62 HV (pure Cu), consistent with microstructural changes. Concurrently, thermal conductivity improved substantially from 13.5 W/m K to 367.9 W/m K, emphasizing Cu’s dominant role in thermal transport. The findings highlight the feasibility of leveraging compositional gradients between 17-4PH and Cu to achieve tailored tooling with optimized thermal and mechanical performance.

17-4PH↗

Indoor tests of a hot-air solar collector

Data taken relating indoor testing using solar simulator at Marshall Space Center has been compared with data taken during outdoor tests in previous studies. Data includes tests on thermal performance, time constance, and incidence-angle modifier tests in table/graph form.

Source record↗

Preliminary endurance tests of water vaporizers for resistojet applications

Three water vaporizers designed for resistojet applications were built and tested for periods up to 500 h and 250 thermal cycles. Two of the vaporizers were not sensitive to orientation with respect to gravity, an indication of likely compatibility with low-gravity environments. Some temperatures and pressures in the third were impacted by orientation, although operation was always stable. The pressure drop across the sand-filled version increased by 147 percent in 38 h and 19 thermal cycles. Bonding of the sand granules in the downstream end of the heat exchanger was the suspected cause of failure of this vaporizer. Pressure drops across the two sintered stainless steel-filled versions were more gradual. One, with a pore size of 60 microns, showed an 80 percent increase in 500 h and 250 thermal cycles and another, with a 10 microns poresize, showed a 29 percent increase in 350 h and 175 thermal cycles. Testing of the latter metal-filled vaporizer was ongoing as of this writing. Oxidation of the porous metal packing materials in these vaporizers, with subsequent deposition of oxide particles within the pores, was believed to have caused the observed increases in pressure drops.

Morren, W. Earl↗

Preliminary endurance tests of water vaporizers for resistojet applications

Three water vaporizers designed for resistojet applications were built and tested for periods up to 500 h and 250 thermal cycles. Two of the vaporizers were not sensitive to orientation with respect to gravity, an indication of likely compatibility with low-gravity environments. Some temperatures and pressures in the third were impacted by orientation, although operation was always stable. The pressure drop across the sand-filled version increased by 147 percent in 38 h and 19 thermal cycles. Bonding of the sand granules in the downstream end of the heat exchanger was the suspected cause of failure of this vaporizer. Pressure drops across the two sintered stainless steel-filled versions were more gradual. One, with a pore size of 60 microns, showed an 80 percent increase in 500 h and 250 thermal cycles and another, with a 10 microns poresize, showed a 29 percent increase in 350 h and 175 thermal cycles. Testing of the latter metal-filled vaporizer was ongoing as of this writing. Oxidation of the porous metal packing materials in these vaporizers, with subsequent deposition of oxide particles within the pores, was believed to have caused the observed increases in pressure drops.

Morren, W. E.↗

STS-69 Mission Highlights Resource Tape

The STS-69 mission of the Endeavour Space Shuttle and crew are highlighted in this video. The 'Dog Crew', as they called themselves, Cmdr. Dave Walker, Pilot Ken Cockrell, and Mission Specialists Mike Gernhardt, Jim Voss, and Jim Newman, are shown performing pre-launch and launch activities; the SPARTAN-201 and the Wake Shield Facility (WSF) deployments, retrievals, and berthings; physiological and other Middeck experiments; and jet thruster firing tests on the WSF. A 6 1/2 hour EVA was conducted to test the thermal properties of the new space suits and to test the tools and equipment to be used in the construction of the International Space Station. General crew activities are also shown and Earth views include cloud cover and the WSF with the Earth as the background.

Source record↗

SHARP-B2: Flight Test Objectives, Project Implementation and Initial Results

On September 28, 2000 the SHARP-B2 flight experiment was launched from Vandenberg Air Force Base, California. SHARP-B2 is the 2nd Ballistic flight test in the SHARP (Slender Hypervelocity Aerothermodynamic Research Probes) program which develops and tests new thermal protection materials and sharp body concepts. The flight tested Ultra-High Temperature Ceramics (UHTCs), which may radically change the design and performance of future aerospace vehicles. The new designs may overturn an age-old tenet of aerodynamics: that blunt-body aerospace vehicles, but not those with sharp leading edges, can survive the searing temperatures created as the vehicles tear through the atmosphere. Sharp leading edges offer numerous advantages over the blunt-body design currently in use. They could allow a space shuttle or crew return vehicle to maneuver in space more like an airplane and potentially allow astronauts to return to Earth from anywhere on orbit. They may allow improved astronaut safety by decreasing the risk of aborting into the ocean. They may reduce the electromagnetic interference that causes the communications blackouts that plague reentering blunt-body space vehicles. Reducing the amount of drag could lead to a reduction in propulsion requirements. Planetary probes could make use of sharp-body technology for aerobraking and to maximize their maneuvering capability. SHARP-B2 was a joint effort among NASA Ames, Sandia National Laboratories, the U.S. Air Force and the U.S. Army. It was funded by the Pathfinder Program at NASA's Marshall Space Flight Center. The SHARP-B2 payload was carried aboard a U.S. Air Force Minuteman III missile carrying a modified Mk 12A reentry vehicle (RV), which blasted off from Vandenberg Air Force Base near Lompoc, CA, at 3:01 a.m. PDT on Sept. 28. The RV was equipped with four 5. 1 inch-long strakes, or sharp leading edges. Each strake contained three UHTCs: ZrB2/SiC/C; ZrB2/SiC; and HfB2/SiC. Once it reached an altitude of about 400 nautical miles, the RV was released, returning through Earth's atmosphere at speeds exceeding Mach 22. One pair of strakes was designed to retract just before reaching temperatures high enough to cause the material to begin ablating. The other pair was designed to retract shortly after ablation began, at an expected temperature of nearly 5,100 degrees Fahrenheit. Sensors in the strakes measured how closely performance matched pre-flight calculations, and data was successfully collected throughout the 23-minute flight. A parachute was deployed (but not fully inflated) and the RV splashed down in a lagoon at the Kwajalein missile range in the Pacific Ocean. Within 3 hours radar track analysis showed ocean entry to be precisely at the latitude/longitude coordinates estimated during pre-flight simulation. An hour later a ship was deployed by the Army to recover the reentry vehicle, which was recovered in 165 feet of water, just 500 feet from its planned splash-down point. This is the first RV recovery in over a decade.

Salute, Joan↗