Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Static force tests of a sharp leading edge delta-wing model at ambient and cryogenic temperatures with a description of the apparatus employed

A sharp leading edge delta-wing model was tested through an angle-of-attack range at Mach numbers of 0.75, 0.80, and 0.85 at both ambient and cryogenic temperatures in the Langley 1/3-meter transonic cryogenic tunnel. Total pressure was varied with total temperature in order to hold test Reynolds number constant at a given Mach number. Agreement between the aerodynamic data obtained at ambient and cryogenic temperatures indicates that flows with leading-edge vortex effects are duplicated properly at cryogenic temperatures. The test results demonstrate that accurate aerodynamic data can be obtained by using conventional force-testing techniques if suitable measures are taken to minimize temperature gradients across the balance and to keep the balance at ambient (warm) temperatures during cryogenic operation of the tunnel.

Kilgore, R. A.↗

Error in temperature measurements due to conduction along the sensors

When a sensor is embedded in a solid body to measure its internal temperature, any conduction to or from its sensing element may cause the indicated temperature to be different from the true temperature. This paper describes an analysis of the error caused by conduction when there is an arbitrary temperature distribution in the body along the sensor. The sensor is modeled as a cylindrical fin and the appropriate conduction equation is solved. The solution gives a correction for the error which depends on such parameters as, depth of immersion, thermocouple wire and insulation properties, contact between the sensor and the body, and temperature distribution in the body. The latter may not be known, but the measured temperature distribution can be used as a first approximation. The corrected value can then be used to obtain a better estimate of the error. The results show good agreement with experimental observations.

Singh, B. S.↗

The stress corrosion resistance and the cryogenic temperature mechanical properties of annealed Nitronic 60 bar material

Ambient and cryogenic temperature mechanical properties and the ambient temperature stress corrosion properties of annealed, straightened, and centerless ground Nitronic 60 stainless steel alloy bar material are presented. The mechanical properties of longitudinal specimens were evaluated at test temperatures from ambient to liquid hydrogen. The tensile test data indicated increasing strength with decreasing temperature to -196 C. Below liquid nitrogen temperature the smooth tensile and notched tensile strengths decreased slightly while the elongation and reduction of area decreased drastically. The Charpy V-notched impact energy decreased steadily with decreasing test temperature. Stress corrosion tests were performed on longitudinal tensile specimens and transverse C-ring specimens exposed to: alternate immersion in a 3.5% NaCl bath; humidity cabinet; and a 5% salt spray atmosphere. The longitudinal tensile specimens experienced no corrosive attack. Approximately 3/4 of the transverse C-rings exposed to alternate immersion and to salt spray experienced a pitting attack on the top and bottom ends. Additional stress corrosion tests were performed on transverse tensile specimens. No failures occurred in the 90% stressed specimens exposed for 90 days in the alternate immersion and salt spray environments

Montano, J. W. L.↗

Effects of temperature transients at fan inlet of a turbofan engine

The effects of fan inlet temperature transients on the performance and stability of a turbofan engine were determined. The experiment was conducted at 90 and 74 percent of low-pressure-rotor military speed (9525 rpm) and with fan inlet temperature distortions having circumferential extents of 90 deg, 180 deg, 270 deg, and 360 deg. Temperature transients were controlled by varying the magnitude and rate of change of the inlet temperature rise. The engine response ranged from a momentary compressor pressure disturbance to low-pressure-compressor stall. The compressor distortion limits decreased with decreasing low-pressure-rotor speed and increased with increasing circumferential extent of distortion. Analysis of the data suggests strongly that the distortion limits of the compressor are a function of a critical magnitude of inlet temperature rise and are independent of the temperature rise rate.

Abdelwahab, M.↗

Soil and surface temperatures at the Viking landing sites

The annual temperature range for the Martian surface at the Viking lander sites is computed on the basis of thermal parameters derived from observations made with the infrared thermal mappers. The Viking lander 1 (VL1) site has small annual variations in temperature, whereas the Viking lander 2 (VL2) site has large annual changes. With the Viking lander images used to estimate the rock component of the thermal emission, the daily temperature behavior of the soil alone is computed over the range of depths accessible to the lander; when the VL1 and VL2 sites were sampled, the daily temperature ranges at the top of the soil were 183 to 263 K and 183 to 268 K, respectively. The diurnal variation decreases with depth with an exponential scale of about 5 centimeters. The maximum temperature of the soil sampled from beneath rocks at the VL2 site is calculated to be 230 K. These temperature calculations should provide a reference for study of the active chemistry reported for the Martian soil.

Kieffer, H. H.↗

Global exospheric temperatures and densities under active solar conditions

Temperatures measured by the OGO-6 satellite using the 6300 A airglow spectrum are compared with temperatures derived from total densities and N2 densities. It is shown that while the variation of the total densities with latitude and magnetic activity agree well with values used for CIRA (1972), the temperature behavior is very different. While the temperatures derived from the N2 density were in much better agreement there were several important differences which radically affect the pressure gradients. The variation of temperature with magnetic activity showed seasonal and local time variations. Neutral temperature, density, pressure and boundary oxygen variations for the storm of 8 March 1970 are presented.

Nisbet, J. S.↗

Effect of turbulence on line-reversal temperature measurements

The effect of turbulent temperature fluctuations on line-reversal temperature measurements is examined in the thin gas, small fluctuation limit. It is shown that in this limit the fluctuations have no effect on the time average results. Only in case of a spacially uniform temperature can the fluctuating component of the temperature be directly measured. For the case of a spacially uniform mean temperature, a spacial average of the fluctuating component can be measured. For the completely nonuniform case, only a complex spacial average of the fluctuating and mean temperatures can be measured.

Daily, J. W.↗

A global thermospheric model based on mass spectrometer and incoherent scatter data MSIS. I - N2 density and temperature

Measurements of neutral nitrogen density from mass spectrometers on five satellites (AE-B, Ogo 6, San Marco 3, Aeros A, and AE-C) and neutral temperatures inferred from incoherent scatter measurements at four ground stations are combined to produce a model of thermospheric neutral temperatures and nitrogen densities similar to the Ogo 6 empirical model (Hedin et al., 1974). This global model is designated MSIS (mass spectrometer and incoherent scatter). The global average temperature, the annual temperature variation, lower bound density, and lower bound temperature are discussed. The data set covers the time period from the end of 1965 to mid-1975 and also a wide range of solar activities. Diurnal and semidiurnal variations in lower bound density and temperature are considered, as is magnetic activity.

Hedin, A. E.↗

Evolution of the high-temperature plasma in the 15 June 1973 flare

The evolution of the high-temperature plasma in the solar flare of June 15, 1973, is analyzed using XUV spectroheliograms obtained from Skylab. Preflare enhancement of loops in the active region is discussed, and the temperature and density of the hot plasma are determined as a function of time. The turbulent velocity in the high-temperature plasma is deduced from a comparison of line widths of the Fe XXIV doublet at 192 and 255 A. The results indicate that: (1) the flare occurred in a low-lying loop or loops; (2) the large-scale magnetic-field configuration of the active region did not change significantly; (3) the hot plasma observed in Fe XXIII-XXIV showed considerable dynamic activity, including an initial upward motion of the whole plasma with a velocity of about 80 km/s; (4) large turbulent mass motions took place in the Fe XXIII-XXIV plasma with random velocities of 100 to 160 km/s; (5) the temperature of the hot plasma was 14 million K at peak X-ray intensity, decreased slightly, and then remained at 12.6 million K before dropping to below 10 million K; and (6) there was a temperature gradient along the length of the loop, with the 14 million-K plasma near the top and progressively lower-temperature plasmas on either side.

Cheng, C.-C.↗

Paleoatmospheric temperature structure

Radiative equilibrium and radiative convective temperature profiles for the earth's evolving atmosphere have been calculated. If the atmosphere evolved from one rich in carbon dioxide, and deficient in oxygen, to its present composition, the temperature structure showed considerable change. The models of 3 to 4 billion years ago display steadily decreasing temperatures with altitude, being 185 K at pressures associated with the present-day upper stratosphere. A lapse rate feature similar to the present-day tropopause is not indicated until about 1 billion years ago; but the stratospheric region is approximately 15 K colder than presently found at comparable pressures. Surface temperatures approximately 10 K warmer than at present existed until nearly 1 billion years ago. When the oxygen content exceeded roughly 0.1 times the present level, surface temperatures began to decrease. If biological processes are important to carbon dioxide - ozone variations, such as has been suggested during the Ice Ages, then estimates of surface temperature should include the effects of both gases.

Morss, D. A.↗

A numerical simulation of seasonal stratospheric climate. I - Zonal temperatures and winds

Two numerical experiments were designed to isolate the effects of seasonal and latitudinal variations in longwave radiative transfer processes. The first experiment aimed at computing the rate of temperature change in the stratosphere due to longwave radiative transfer by CO2, H2O and O3 from Ramanathan's (1976) radiative-convective model applied to the troposphere-stratosphere circulation. The second experiment employs the Newtonian cooling approximation in which the rate of temperature change in the stratosphere by longwave radiative transfer is set equal to the product of the Newtonian cooling coefficient 'h' and the departure of the local temperature from a reference temperature. It is shown that the latitudinal temperature distribution of the lower stratosphere is maintained by the combined effects of dynamics, O3 solar heating and the longwave radiative coupling between troposphere and stratosphere. The latitudinal gradient in the troposphere-stratosphere longwave radiative coupling is maximum during winter and spring. The radiative response time (1/h) of the middle and upper stratosphere undergoes significant latitudinal and seasonal variations, largely due to the temperature dependence of h.

Ramanathan, V.↗

Surface temperature measurements in rolling and sliding EHD contacts

In this study, moving surface temperature measurements in rolling and sliding EHD point contacts were made using an available infrared technique. Film thickness and traction have also been measured. Slide-to-roll ratios of -2 to +2 have been studied. By using a different kinematic configuration, stationary surface temperatures have also been measured. It has been shown that, while surface temperature rises in the low slip region are relatively small, stationary surface temperatures are significantly higher than the moving surface temperatures. Flash temperature theory has been extended to cover the combined rolling and sliding conditions. Correlation between the predicted and the measured values has also been performed.

Nagaraj, H. S.↗

High-temperature microphone system

Pressure fluctuations in air or other gases in an area of elevated temperature are measured using a condenser microphone located in the area of elevated temperature and electronics for processing changes in the microphone capacitance located outside the area the area and connected to the microphone by means of high-temperature cable assembly. The microphone includes apparatus for decreasing the undesirable change in microphone sensitivity at high temperatures. The high temperature cable assembly operates as a half-wavelength transmission line in an AM carrier system and maintains a large temperature gradient between the two ends of the cable assembly. The processing electronics utilizes a voltage controlled oscillator for automatic tuning thereby increasing the sensitivity of the measuring apparatus.

Zuckerwar, A. J.↗

Low-pressure performance of annular, high-pressure (40 atm) high-temperature (2480 K) combustion system

Experimental tests were conducted to develop a combustion system for a 40 atmosphere pressure, 2480 K exhaust gas temperature, turbine cooling facility. The tests were conducted in an existing facility with a maximum pressure capability of 10 atmospheres and where inlet air temperatures as high as 894 K could be attained. Exhaust gas temperatures were as high as 2365 K. Combustion efficiences were about 100 percent over a fuel air ratio range of 0.016 to 0.056. Combustion efficiency decreased at leaner and richer ratios when the inlet air temperature was 589 K. Data are presented that show the effect of fuel air ratio and inlet air temperature on liner metal temperature. Isothermal system pressure loss as a function of diffuser inlet Mach number is also presented. Data included exhaust gas pattern factors; unburned hydrocarbon, carbon monoxide, and oxides of nitrogen emission index values; and smoke numbers.

Wear, J. D.↗

Surface chemistry and friction behavior of the silicon carbide (0001) surface at temperatures to 1500 deg C

X-ray photoelectron and Auger electron spectroscopy analyses and friction studies were conducted with a silicon carbide (0001) surface in contact with iron at various temperatures to 1200 or 1500 C in a vacuum of 10 to the minus 8th power Pa. The results indicate that there is a significant temperature influence on both the surface chemistry and friction properties of silicon carbide. The principal contaminant of adsorbed amorphous carbon on the silicon carbide surface in the as received state is removed by simply heating to 400 C. Above 400 C, graphite and carbide type carbine are the primary species on the silicon carbide surface, in addition to silicon. The coefficients of friction of polycrystalline iron sliding against a single crystal silicon carbide (0001) surface were high at temperatures to 800 C. Similar coefficients of friction were obtained at room temperature after the silicon carbide was preheated at various temperatures up 800 C. When the friction experiments were conducted above 800 C or when the specimens were preheated to above 800 C, the coefficients of friction were dramatically lower. At 800 C the silicon and carbide type carbon are at a maximum intensity in the XPS spectra. With increasing temperature above 800 C, the concentration of the graphite increases rapidly on the surface, whereas those of the carbide type carbon and silicon decrease rapidly.

Miyoshi, K.↗

Experimental relations between airborne and ground measured wheat canopy temperatures

Experiments using ground-based measurements of canopy temperatures have shown that plant temperatures are good indicators of plant water stress, and thus are useful for assessing water requirements and predicting yields. An intensive 23-day airborne- and ground-measurement program was conducted in Phoenix, Arizona in 1977 to compare airborne-acquired wheat canopy temperatures with simultaneous ground measurements. For canopies that covered at least 85 percent of the soil surface, airborne measurements differed from ground measurements of plant temperature by less than 2 C. Regardless of the amount of plant cover, the airborne measurements were virtually identical to ground-nadir measurements, and thus represent a combination of plant temperature and solid background temperature.

Millard, J. P.↗

Ion temperature anisotropy and heat flow in the Venus lower ionosphere

Motivated by the recent observations of supersonic ion flow in the Venus ionosphere near the terminator, the paper studies the extent to which such a flow can induce an ion temperature anisotropy and a diffusion-thermal heat flow. Calculations indicate that appreciable ion temperature anisotropies can be induced at altitudes below about 220 km. The temperature anisotropy is with respect to the ion-neutral relative drift velocity vector, with the ion temperature parallel to the relative drift velocity greater than the perpendicular ion temperature. The parallel to perpendicular ion temperature ratio is likely to be in the range of from 2 to 4, depending on the ionospheric conditions. It is also found that in the same ionospheric region the ion neutral relative drift induces a diffusion-thermal heat flow that is considerably more important than ordinary ion thermal conduction.

Schunk, R. W.↗

Infrared-temperature variability in a large agricultural field

Dunnigan Agro-Meteorological Experiment airborne thermal scanner images of a large varying-terrain barley field are acquired and analyzed. Temperature variability that may occur within instantaneous fields of view (IFOV) is defined (coefficient of variation: standard deviation/mean temperature in degrees C), and the percentage of the area within various IFOV's within + or - 1, 2, 3, and 5 degrees of the mean is determined. With the exception of very rugged terrain, over 80% of the area within 4, 16, 65 and 258 ha cells was at temperatures within + or - 3 C of the mean cell temperature. Remote measurements of field temperature appeared to be slightly influenced by pixel size in the range 4 ha to 259 ha, and the area percentage within any pixel which contributes within + or - 1, 2, 3, and 5 degrees C of the mean, is nominally the same. In conclusion, no great advantage is found in utilizing a small IFOV instead of a large one for remote sensing of crop temperature.

Millard, J. P.↗