Mechanics of the Ring Tension Test (RTT): A Finite Element-based Investigation

The ring tension test (RTT) is an experimental method for determining mechanical behavior in a material’s circumferential or hoop direction. It is a crucial test for testing anisotropic materials with tube geometry, such as nuclear fuel cladding or irradiated pipes. Several RTT configurations exist, each with their own advantages and disadvantages. However, this test is significantly more complex than traditional tensile testing and can be especially sensitive to small differences and inconsistencies in the test setup and geometry, ultimately affecting the derived mechanical properties. Previous research has focused on method development, and little work has been done on understanding the subtle differences between an ideal test and experiments, specifically when the tests are performed on highly irradiated materials in hot cells. In this work, a finite element-based investigation of the RTT is conducted. Two promising test configurations are investigated, comparing their ability to determine accurate material strengths through plastic deformation. Several non-ideal conditions and uncontrollable effects which are likely to occur during experimental testing such as machining tolerances, variations of specimen geometry from nominal dimensions, rotation of specimens and fixturing, and other test setup discrepancies are studied. The sensitivity of measured strengths to these conditions is presented. A mechanics-based approach to describing and correcting raw data to determine actual strengths is also included for one of the configurations, resulting in a robust correction method with highly accurate material strength measurements. Based on these analyses, the hemicylindrical mandrel configuration is recommended with a gauge region oriented at a 45° angle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Philosophy which underlies the structural tests of a supersonic transport aircraft with particular attention to the thermal cycle

The information presented is based on data obtained from the Concorde. Much of this data also applies to other supersonic transport aircraft. The design and development of the Concorde is a joint effort of the British and French, and the structural test program is shared, as are all the other activities. Vast numbers of small specimens have been tested to determine the behavior of the materials used in the aircraft. Major components of the aircraft structure, totalling almost a complete aircraft, have been made and are being tested to help the constructors in each country in the design and development of the structure. Tests on two complete airframes will give information for the certification of the aircraft. A static test was conducted in France and a fatigue test in the United Kingdom. Fail-safe tests are being made to demonstrate the crack-propagation characteristics of the structure and its residual strength. Aspects of the structural test program are described in some detail, dealing particularly with the problems associated with the thermal cycle. The biggest of these problems is the setting up of the fatigue test on the complete airframe; therefore, this is covered more extensively with a discussion about how the test time can be shortened and with a description of the practical aspects of the test.

Ripley, E. L.↗

Shuttle payload vibroacoustic test plan evaluation

Statistical decision theory is used to evaluate seven alternate vibro-acoustic test plans for Space Shuttle payloads; test plans include component, subassembly and payload testing and combinations of component and assembly testing. The optimum test levels and the expected cost are determined for each test plan. By including all of the direct cost associated with each test plan and the probabilistic costs due to ground test and flight failures, the test plans which minimize project cost are determined. The lowest cost approach eliminates component testing and maintains flight vibration reliability by performing subassembly tests at a relatively high acoustic level.

Stahle, C. V.↗

Accelerated life testing effects on CMOS microcircuit characteristics

This report covers the time period from May 1976 to December 1979 and encompasses the three phases of accelerated testing: Phase 1, the 250 C testing; Phase 2, the 200 C testing; and Phase 3, the 125 C testing. The duration of the test in Phase 1 and Phase 2 was sufficient to take the devices into the wear out region. The wear out distributions were used to estimate the activation energy between the 250 C and the 200 C test temperatures. The duration of the 125 C test, 20,000 hours, was not sufficient to bring the test devices into the wear out region; consequently the third data point at 125 C for determining the consistency of activation energy could not be obtained. It was estimated that, for the most complex of the three device types, the activation energy between 200 C and 125 C should be at least as high as that between 250 C and 200 C. The practicality of the use of high temperature for the accelerated life tests from the point of view of durability of equipment was assessed. Guidelines for the development of accelerated life test conditions were proposed. The use of the silicon nitride overcoat to improve the high temperature accelerated life test characteristics of CMOS microcircuits was explored in Phase 4 of this study and is attached as an appendix to this report.

Source record↗

Initial evaluation tests of General Electric Company 12.0 ampere hour nickel cadmium spacecraft cells with design variables

All evaluation tests were performed at room ambient pressure and temperature, with discharges at a 2 hour rate. Tests consisted of phenolphthalein leak tests, three capacity tests, an auxiliary electrode test, a charge retention test, an internal short test, a charge efficiency test, overcharge tests, and a pressure versus capacity test. Results of the tests and recommendations for improvements in manufacturing are presented.

Harkness, J. D.↗

Aerofoil testing in a self-streamlining flexible walled wind tunnel

Two-dimensional self-streamlining flexible walled test sections eliminate, as far as experimentally possible, the top and bottom wall interference effects in transonic aerofoil testing. The test section sidewalls are rigid, while the impervious top and bottom walls are flexible and contoured to streamline shapes by a system of jacks, without reference to the aerofoil model. The concept of wall contouring to eliminate or minimise test section boundary interference in two-dimensional testing was first demonstrated by the National Physical Laboratory (NPL) in England during the early 1940's. The transonic streamlining strategy proposed, developed and used by NPL has been compared with several modern strategies. The NPL strategy has proved to be surprisingly good at providing a wall interference-free test environment, giving model performance indistinguishable from that obtained when using the modern strategies over a wide range of test conditions. In all previous investigations the achievement of wall streamlining in flexible walled test sections has been limited to test conditions up to those which result in the model's shock just extending to a streamlined wall. This work, however, has also successfully demonstrated the feasibility of two-dimensional wall streamlining at test conditions where both model shocks have reached and penetrated through their respective flexible walls. Appropriate streamlining procedures have been established and are uncomplicated, enabling flexible walled test sections to easily cope with these high transonic flows.

Mark Charles Lewis↗

Comparing the effectiveness of software testing strategies

This study compares the results of code reading, functional testing, and structural testing in three aspects of software testing: fault detection effectiveness, fault detection cost, and classes of faults detected. Thirty two professional programmers and 42 advanced students applied the three techniques to four unit-sized programs in a fractional experimental design. The major results of this study are the following: (1) With the professional programmers, code reading detected more software faults and had a higher detection rate than did functional or structural testing, while functional testing detected more faults than did structural testing, but functional and structural testing were not different in fault detection rate. (2) In one advanced student subject group, code reading and functional testing were not different in faults found, but were superior to structural testing, while in the other advanced student subject group there was no difference among the techniques. (3) With the advanced student subjects, the three techniques were not different in fault deteciton rate. (4) Number of faults observed, fault detection rate, and total effort in detection depended on the type of software tested. (5) Code reading detected more interface faults than did the other methods. (6) Functional testing detected more control faults than did the other methods. (7) When asked to estimate the percentage of faults detected, code readers gave the most accurate estimates while functional testers gave the least accurate estimates. Appendix B includes the source code for the word.

Basili, Victor R.↗

Software unit testing in Ada environment

A validation procedure for the Ada binding of the Graphical Kernel System (GKS) is being developed. PRIOR Data Sciences is also producing a version of the GKS written in Ada. These major software engineering projects will provide an opportunity to demonstrate a sound approach for software testing in an Ada environment. The GKS/Ada validation capability will be a collection of test programs and data, and test management guidelines. These products will be used to assess the correctness, completeness, and efficiency of any GKS/Ada implementation. The GKS/Ada developers will be able to obtain the validation software for their own use. It is anticipated that this validation software will eventually be taken over by an independent standards body to provide objective assessments of GKS/Ada implementations, using an approach similar to the validation testing currently applied to Ada compilers. In the meantime, if requested, this validation software will be used to assess GKS/Ada products. The second project, implementation of GKS using the Ada language, is a conventional software engineering tasks. It represents a large body of Ada code and has some interesting testing problems associated with automatic testing of graphics routines. Here the normal test practices which include automated regression testing, independent quality assistance, test configuration management, and the application of software quality metrics will be employed. The software testing methods emphasize quality enhancement and automated procedures. Ada makes some aspects of testing easier, and introduces some concerns. These issues are addressed.

Warnock, Glenn↗

Orbital transfer vehicle oxygen turbopump technology. Volume 2: Nitrogen and ambient oxygen testing

The testing of a rocket engine oxygen turbopump using high pressure ambient temperature nitrogen and oxygen as the turbine drive gas in separate test series is discussed. The pumped fluid was liquid nitrogen or liquid oxygen. The turbopump (TPA) is designed to operate with 400 F oxygen turbine drive gas which will be demonstrated in a subsequent test series. Following bearing tests, the TPA was finish machined (impeller blading and inlet/outlet ports). Testing started on 15 February 1989 and was successfully concluded on 21 March 1989. Testing started using nitrogen to reduce the ignition hazard during initial TPA checkout. The Hydrostatic Bearing System requires a Bearing Pressurization System. Initial testing used a separate bearing supply to prevent a rubbing start. Two test series were successfully completed with the bearing assist supplied only by the pump second stage output which entailed a rubbing start until pump pressure builds up. The final test series used ambient oxygen drive and no external bearing assist. Total operating time was 2268 seconds. There were 14 starts without bearing assist and operating speeds up to 80,000 rpm were logged. Teardown examination showed some smearing of silverplated bearing surfaces but no exposure of the underlying monel material. There was no evidence of melting or oxidation due to the oxygen exposure. The articulating, self-centering hydrostatic bearing exhibited no bearing load or stability problems. The only anomaly was higher than predicted flow losses which were attributed to a faulty ring seal. The TPA will be refurbished prior to the 400 F oxygen test series but its condition is acceptable, as is, for continued operating. This was a highly successful test program.

Brannam, R. J.↗

Evaluation of the concept of pressure proof testing fuselage structures

The FAA and NASA have recently completed independent technical evaluations of the concept of pressure proof testing the fuselage of commercial transport airplanes. The results of these evaluations are summarized. The objectives of the evaluations were to establish the potential benefit of the pressure proof test, to quantify the most desirable proof test pressure, and to quantify the required proof test interval. The focus of the evaluations was on multiple-site cracks extending from adjacent rivet holes of a typical fuselage longitudinal lap splice joint. The FAA and NASA do not support pressure proof testing the fuselage of aging commercial transport aircraft. The argument against proof testing is as follows: (1) a single proof test does not insure an indefinite life; therefore, the proof test must be repeated at regular intervals; (2) for a proof factor of 1.33, the required proof test interval must be below 300 flights to account for uncertainties in the evaluation; (3) conducting the proof test at a proof factor of 1.5 would considerably exceed the fuselage design limit load; therefore, it is not consistent with accepted safe practices; and (4) better safety can be assured by implementing enhanced nondestructive inspection requirements, and adequate reliability can be achieved by an inspection interval several times longer than the proof test interval.

Harris, Charles E.↗

Thermal verification testing of commercial printed-circuit boards for spaceflight

A method developed to verify commercial printed-circuit boards for a Shuttle orbital flight is discussed. The test sequence is based on early fault detection, desire to test the final assembly, and integration with other verification testing. A component thermal screening test is performed first to force flaws in design, workmanship, parts, processes, and materials into observable failures. Temperature definition and vibration tests are performed next. Final assembly testing is performed to simulate the Shuttle flight. An abbreviated thermal screening test is performed as a check after the vibration test, and then a complete thermal operational test is performed. The final assembly test finishes up with a burn-in of 100 h of trouble-free operation. Verification is successful when all components and final assemblies have passed each test. This method was very successful in verifying that commercial printed-circuit boards will survive in the Shuttle environment.

Foster, William M., II↗

SITE project. Phase 1: Continuous data bit-error-rate testing

The Systems Integration, Test, and Evaluation (SITE) Project at NASA LeRC encompasses a number of research and technology areas of satellite communications systems. Phase 1 of this project established a complete satellite link simulator system. The evaluation of proof-of-concept microwave devices, radiofrequency (RF) and bit-error-rate (BER) testing of hardware, testing of remote airlinks, and other tests were performed as part of this first testing phase. This final report covers the test results produced in phase 1 of the SITE Project. The data presented include 20-GHz high-power-amplifier testing, 30-GHz low-noise-receiver testing, amplitude equalization, transponder baseline testing, switch matrix tests, and continuous-wave and modulated interference tests. The report also presents the methods used to measure the RF and BER performance of the complete system. Correlations of the RF and BER data are summarized to note the effects of the RF responses on the BER.

Fujikawa, Gene↗

Special tests and destructive physical analyses as used by the Aerospace Corporation with nickel-hydrogen cells

The destructive physical analysis (DPA) of electrochemical devices is an important part of the overall test. Specific tests were developed to investigate the degradation mode or the failure mechanism that surfaces during the course of a cell being assembled, acceptance tested, and life-cycle tested. The tests that have been developed are peculiar to the cell chemistry under investigation. Tests are often developed by an individual or group of researchers as a result of their particular interest in an unresolved failure mechanism or degradation mode. A series of production, operational, and storage issues that were addressed by the Electrochemistry Group at The Aerospace Corporation are addressed. As a result of these investigations, as well as associated research studies carried out to develop a clearer understanding of the nickel oxyhydroxide electrode, a series of unique and useful specialized tests were developed. Some of these special tests were assembled to describe the methods that were found to be particularly useful in resolving a wide spectrum of manufacturing, operational, and storage issues related to nickel-hydrogen cells. The general methodology of these tests is given here with references listed to provide the reader with a more detailed understanding of the tests. The tests are classified according to the sequencing, starting with the impregnation of the nickel plaque material and culminating with the storage of completed cells. The details of the wet chemical procedures that were found to be useful because of their accuracy and reproducibility are given. The equations used to make the appropriate calculations are listed.

Zimmerman, A. H.↗

Liquid oxygen (LO2) propellant conditioning concept testing

Testing of a simplified LO2 propellant conditioning concept for future expendable launch vehicles is discussed. Four different concepts are being investigated: no-bleed, low-bleed, use of a recirculation line, and He bubbling. A full-scale test article, which is a facsimile of a propellant feed duct with an attached section to simulate heat input from an LO2 turbopump, is to be tested at the Cold Flow Facility of the Marshall Space Flight Center West Test Area. Work to date includes: design and fabrication of the test article, design of the test facility and initial fabrication, development of a test matrix and test procedures, initial predictions of test output, and heat leak calibration and heat exchanger tests on the test articles.

Perry, Gretchen L. E.↗

Correlation between strength properties in standard test specimens and molded phenolic parts

This report describes an investigation of the tensile, flexural, and impact properties of 10 selected types of phenolic molding materials. The materials were studied to see in what ways and to what extent their properties satisfy some assumptions on which the theory of strength of materials is based: namely, (a) isotropy, (b) linear stress-strain relationship for small strains, and (c) homogeneity. The effect of changing the dimensions of tensile and flexural specimens and the span-depth ratio in flexural tests were studied. The strengths of molded boxes and flexural specimens cut from the boxes were compared with results of tests on standard test specimens molded from the respective materials. The nonuniformity of a material, which is indicated by the coefficient of variation, affects the results of tests made with specimens of different sizes and tests with different methods of loading. The strength values were found to depend on the relationship between size and shape of the molded specimen and size and shape of the fillers. The most significant variations observed within a diversified group of materials were found to depend on the orientation of fibrous fillers. Of secondary importance was the dependence of the variability of test results on the pieces of filler incorporated into the molding powder as well as on the size of the piece. Static breaking strength tests on boxes molded from six representative phenolic materials correlated well with falling-ball impact tests on specimens cut from molded flat sheets. Good correlation was obtained with Izod impact tests on standard test specimens prepared from the molding materials. The static breaking strengths of the boxes do not correlate with the results of tensile or flexural tests on standard specimens.

MATERIALS, MONSANTO RESINOX↗

Program Helps Design Tests Of Developmental Software

Computer program called "A Formal Test Representation Language and Tool for Functional Test Designs" (TRL) provides automatic software tool and formal language used to implement category-partition method and produce specification of test cases in testing phase of development of software. Category-partition method useful in defining input, outputs, and purpose of test-design phase of development and combines benefits of choosing normal cases having error-exposing properties. Traceability maintained quite easily by creating test design for each objective in test plan. Effort to transform test cases into procedures simplified by use of automatic software tool to create cases based on test design. Method enables rapid elimination of undesired test cases from consideration and facilitates review of test designs by peer groups. Written in C language.

Hops, Jonathan↗

Space Station Freedom NiH2 cell testing program

Testing for the Space Station Freedom Nickel Hydrogen Cell Test Program began in 1990 at Crave Division, Naval Surface Warfare Center. The program has included receipt inspection, random vibration, acceptance, characterization, and life cycle testing of Ni-H2 cells in accordance with the NASA LeRC Interagency Order C-31001-J. A total of 400 Ni-H2 cells have been received at NAVSURFWARCENDIV Crane from three separate manufacturers; Yardney Technical Products (Yardney), Eagle Picher Industries (Eagle Picher), and Gates Energy Products (Gates). Of those, 308 cells distributed among 39 packs have undergone life cycle testing under a test regime simulating low earth orbit conditions. As of 30 September 1993, there are 252 cells assembled into 32 packs still on life cycle test. Since the beginning of the program, failed cells have been detected in all phases of testing. The failures include the following; seven 65 AmpHr and 81 AmpHr Yardney cells were found to be leaking KOH on receipt, one 65 AmpHr Eagle Picher cell failed the acceptance test, one 65 AmpHr Gates cell failed during the characterization test, and six 65 AmpHr Gates cells failed the random vibration test. Of the 39 life cycle packs, testing on seven packs, 56 cells, has been suspended because of low end of discharge voltages. All of the failed life cycle packs were cycled at 60% depth of discharge.

Moore, Bruce↗

Correlation of finite element free vibration predictions using random vibration test data

Finite element analysis is regularly used during the engineering cycle of mechanical systems to predict the response to static, thermal, and dynamic loads. The finite element model (FEM) used to represent the system is often correlated with physical test results to determine the validity of analytical results provided. Results from dynamic testing provide one means for performing this correlation. One of the most common methods of measuring accuracy is by classical modal testing, whereby vibratory mode shapes are compared to mode shapes provided by finite element analysis. The degree of correlation between the test and analytical mode shapes can be shown mathematically using the cross orthogonality check. A great deal of time and effort can be exhausted in generating the set of test acquired mode shapes needed for the cross orthogonality check. In most situations response data from vibration tests are digitally processed to generate the mode shapes from a combination of modal parameters, forcing functions, and recorded response data. An alternate method is proposed in which the same correlation of analytical and test acquired mode shapes can be achieved without conducting the modal survey. Instead a procedure is detailed in which a minimum of test information, specifically the acceleration response data from a random vibration test, is used to generate a set of equivalent local accelerations to be applied to the reduced analytical model at discrete points corresponding to the test measurement locations. The static solution of the analytical model then produces a set of deformations that once normalized can be used to represent the test acquired mode shapes in the cross orthogonality relation. The method proposed has been shown to provide accurate results for both a simple analytical model as well as a complex space flight structure.

Chambers, Jeffrey A.↗