Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scale analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Noise Scaling and Community Noise Metrics for the Hybrid Wing Body Aircraft

An aircraft system noise assessment was performed for the hybrid wing body aircraft concept, known as the N2A-EXTE. This assessment is a result of an effort by NASA to explore a realistic HWB design that has the potential to substantially reduce noise and fuel burn. Under contract to NASA, Boeing designed the aircraft using practical aircraft design princip0les with incorporation of noise technologies projected to be available in the 2020 timeframe. NASA tested 5.8% scale-mode of the design in the NASA Langley 14- by 22-Foot Subsonic Tunnel to provide source noise directivity and installation effects for aircraft engine and airframe configurations. Analysis permitted direct scaling of the model-scale jet, airframe, and engine shielding effect measurements to full-scale. Use of these in combination with ANOPP predictions enabled computations of the cumulative (CUM) noise margins relative to FAA Stage 4 limits. The CUM margins were computed for a baseline N2A-EXTE configuration and for configurations with added noise reduction strategies. The strategies include reduced approach speed, over-the-rotor line and soft-vane fan technologies, vertical tail placement and orientation, and modified landing gear designs with fairings. Combining the inherent HWB engine shielding by the airframe with added noise technologies, the cumulative noise was assessed at 38.7 dB below FAA Stage 4 certification level, just 3.3 dB short of the NASA N+2 goal of 42 dB. This new result shows that the NASA N+2 goal is approachable and that significant reduction in overall aircraft noise is possible through configurations with noise reduction technologies and operational changes.

Burley, Casey L.↗

Analysis of wear debris from full-scale bearing fatigue tests using the Ferrograph

The Ferrograph was used to determine the types of quantities of wear particles generated during full-scale bearing fatigue tests. Deep-groove ball bearings made from AISI 52100 steel were used. A MIL-L-23699 tetraester lubricant was used in a recirculating lubrication system containing a 49-micron absolute filter. Test conditions included a maximum Hertz stress of 2.4 GPa, a shaft speed of 15,000 rpm and a lubricant supply temperature of 74 C (165 F). Four fatigue failures were detected by accelerometers in this test set. In general, the Ferrograph was more sensitive (up to 23 h) in detecting spall initiation than either accelerometers or the normal spectrographic oil analysis (SOAP). Four particle types were observed: normal rubbing wear particles, spheres, nonferrous particles, and severe wear (spall) fragments.

Jones, W. R., Jr.↗

On the significance of power asymmetries in Planck CMB data at all scales

We perform an analysis of the CMB temperature data taken by the Planck satellite investigating if there is any significant deviation from cosmological isotropy. We look for differences in the spectrum between two opposite hemispheres and also for dipolar modulations. We propose a new way to avoid biases due to partial-sky coverage by producing a mask symmetrized in antipodal directions, in addition to the standard smoothing procedure. We also properly take into account both Doppler and aberration effects due to our peculiar velocity and the anisotropy of the noise, since these effects induce a significant hemispherical asymmetry. We are thus able to probe scales all the way to ℓ = 2000. After such treatment we find no evidence for significant hemispherical anomalies along any of the analyzed directions (i.e. deviations are less than 1.5σ when summing over all scales). Although among the larger scales there are sometimes higher discrepancies, these are always less than 3σ. We also find results on a dipolar modulation of the power spectrum. Along the hemispheres aligned with the most asymmetric direction for 2 ≤ ℓ ≤ 2000 we find a 3.3σ discrepancy when comparing to simulations. However, if we do not restrict ourselves to Planck's maximal asymmetry axis, which can only be known a posteriori, and compare Planck data with the modulation of simulations along their respective maximal asymmetry directions, the discrepancy goes down to less than 1σ (with, again, almost 3σ discrepancies in some low-ℓ modes). We thus conclude that no significant power asymmetries seem to be present in the full data set. Interestingly, without proper removal of Doppler and aberration effects one would find spurious anomalies at high ℓ, between 3σ and 5σ. Even when considering only ℓ < 600 we find that the boost is non-negligible and alleviates the discrepancy by roughly half-σ.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Speed Friction-Stir Welding To Enable Aluminum Tailor-Welded Blanks

Current joining technologies for automotive aluminum alloys are utilized in low-volume and niche applications, and have yet to be scaled for the high-volume vehicle market. This study targeted further weight reduction, part reduction, and cost savings by enabling tailor-welded blank technology for aluminum alloys at high-volumes. While friction stir welding has been traditionally applied at linear velocities less than one meter per minute, high volume production applications demand the process be extended to higher velocities more amenable to cost sensitive production environments. Unfortunately, weld parameters and performance developed and characterized at low to moderate welding velocities do not directly translate to high speed linear friction stir welding. Therefore, in order to facilitate production of high volume aluminum welded components, parameters were developed with a minimum welding velocity of three meters per minute. With an emphasis on weld quality, welded blanks were evaluated for post-weld formability utilizing a combination of numerical and experimental methods. Evaluation across scales was ultimately validated by stamping full-size production door inner panels made from dissimilar thickness aluminum tailor-welded blanks, which provided validation of the numerical and experimental analysis of laboratory scale tests.

aluminum↗

Testing- and Model- Based Optimization of Coal-fired Primary Heater Design for Indirect Supercritical CO 2 Power Cycles (Final Scientific and Technical Report)

The overall objective of this project was to perform the R&D necessary to mitigate the risk associated with the design of a primary heat exchanger for a solid-fired combustion system coupled with an indirect-fired closed-loop Brayton Cycle utilizing supercritical CO 2 . The key technological hurdle was the coupling of a solid-fuel firing system with the primary heater, which poses a singular challenge, which is the management of burner performance and operational conditions in a way to manage heat exchanger tube metal temperatures and temperature ramp rates in the absence of fluid phase change on the inside of the tubes. We designed and built the first ever pseudo power system employing a simple recuperated supercritical CO 2 closed-loop Brayton Cycle coupled to a solid-fuel fired system. Advanced coupled CFD and process modeling were used to design the primary heat exchanger (PHX), which consisted of both radiative and convective sections, to limit tube metal temperatures resulting from the heat release profile of the solid fuel flame near the radiative tubes. The heat exchanger was designed to produce finished CO 2 temperatures of 600 °C a pressure of 20.7 MPa and CO 2 flow of 5.5 kg/s. The constructed PHX was capable of 1.2 MWth heat uptake. During design of the PHX, the modeling showed that most variables influencing flame shape (burner stoichiometric ratio and register velocities and swirl) were not suitable to manage heat flux to the metal surfaces. This is because they substantially increased adiabatic flame temperature through the influence of localized stoichiometric ratio. Excess air and firing rate were the two most powerful variables that could be used to control tube surface temperatures. The coupled system was operated for a total of 407 hours, with the longest continuous run of 248 hours. For 62% of the operational time, the unit was unmanned and in automatic control. The fuels used for the testing included natural gas, two Utah Bituminous coals, woody biomass, and bagasse. During the testing we were able to verify the 1.2 MWth heat uptake and we operated at a finished CO 2 temperature of 607 °C and a pressure of 20.3 MPa simultaneously. The real-time corrosion rate of the Super 304H tube CO 2 surface in the region of the radiative section of the PHX were measured, at an approximate temperature of 550 °C. The two key variables related to corrosion rate are the pressure and flow rate of the CO 2 . A technoeconomic analysis was performed at a scale of 120 MWE. The updated analysis showed that the efficiency of an sCO 2 power producing plant will be related to the pressure drop of the PHX.

01 COAL, LIGNITE, AND PEAT↗

Integrated Molten Salt Reactor Modeling Capabilities in NEAMS Thermal Hydraulics Tools

The DOE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program supports a full range of computational thermal fluids analysis capabilities and code developments for a broad range of advanced reactor concepts. The research and development approach under the thermal fluids technical area synergistically combines three length and time scales in a hierarchical multi-scale approach. To enable multi-scale thermal fluids capability using these codes, a key joint effort has been underway to develop an integrated system- and engineering-scale thermal fluids analysis capability, through integration of SAM and Pronghorn codes, both based on the MOOSE framework.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Independent Analyses of Antares R1 Core Design

This report summarizes the reactor analysis work performed by Oak Ridge National Laboratory (ORNL) for Antares Nuclear Incorporated's R1 Mark-1 heat pipe reactor design. The work was performed under a collaboration through the Department of Energy GAIN Nuclear Energy Voucher program. The purpose of this work is to perform an independent reactor analysis of the Antares reactor design and, where possible, compare ORNL's results with the results obtained by Antares. The overarching goal is to provide Antares with an independent review and calculation of their design, thereby contributing to Antares' mission to further their reactor design concept. A report with all ORNL technical results and proprietary details was provided to Antares Nuclear Incorporated separately; the present report provides a summary of the work completed, and all proprietary information is omitted. The independent reactor analysis was performed using both the SCALE code system for neutronics analysis and Flownex for thermal hydraulics analysis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Predictability of Seasonal Means in the NSIPP-1 AGCM

The predictability of seasonal means during 1980-99 is examined from 720 seasonal integrations with version 1 of NASA's Seasonal to Interanual Prediction Project (NSIPP-1) atmospheric general circulation model (AGCM). The AGCM is the atmospheric (and land) component of the NSIPP fully-coupled atmosphere-land-ocean model. For these runs, the initial atmospheric conditions are taken from the National Centers for Environmental Prediction/National Center for Atmospheric Research (NCEP/NCAR) reanalyses, and sea surface temperatures and sea ice are specified from observations. Results from the northern winter integrations show that the model has a very realistic El Nino/Southern Oscillation (ENSO) response in both the tropics and extratropics. Early results from the northern summer runs show a robust extratropical ENSO response in the Southern Hemisphere Pacific, as well as, a pronounced zonally-symmetric component to the ENSO response in both hemispheres. Results will be presented at the meeting highlighting the seasonal evolution in predictability and skill of the NSIPP model on both global and regional scales. A further analysis of the zonally-symmetric response will be discussed in terms of its potential impact on the predictability of middle-latitude climate variability on seasonal to interannual time scales.

Schubert, Siegfried↗

The impact of the fiducial cosmology assumption on BAO distance scale measurements

ABSTRACT Standard analysis pipelines for measurements of Baryon Acoustic Oscillations (BAO) in galaxy surveys make use of a fiducial cosmological model to guide the data compression required to transform from observed redshifts and angles to the measured angular and radial BAO peak positions. In order to remove any dependence on the fiducial cosmology from the results, all models compared to the data should mimic the compression and its dependence on the fiducial model. In practice, approximations are made when testing models: (1) There is assumed to be no residual dependence on the fiducial cosmology after reconstruction, (2) differences in the distance–redshift relationship are assumed to match a linear scaling, and (3) differences in clustering between true and fiducial models are assumed to be removed by the free parameters used to null the non-BAO signal. We test these approximations using the current standard measurement procedure with a set of halo catalogues from the aemulus suite of N-body simulations, which span a range of wCDM cosmological models. We focus on reconstruction of the primordial BAO and locating the BAO. For the range of wCDM cosmologies covered by the aemulus suite, we find no evidence for systematic errors in the measured BAO shift parameters α∥ and α⊥ to $\lt 0.1\%$. However, the measured errors $\sigma _{\alpha _{\parallel }}$ and $\sigma _{\alpha _{\bot }}$ show a notable absolute increase by up to +0.001 and +0.002, respectively, in the case that the fiducial cosmology does not match the truth. These effects on the inferred BAO scale will be important, given the precision of measurements expected from future surveys including DESI, Euclid, and WFIRST.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis on the Heat Transfer Phenomena Inside the Scaled-Down VHTR RCCS Riser Experiment

Very High Temperature gas-cooled Reactor (VHTR) that is one of GEN-IV reactors has been developed for the purpose of hydrogen production. VHTR is characterized by high operating temperature and stepped-up inherent safety given by passive safety systems such as Reactor Cavity Cooling System (RCCS). In case the active heat removal system losses its capability, RCCS significantly contributes to the inherent safety of VHTR by removing the decay heat transferred from the reactor core to the reactor vessel. Therefore, the performance of RCCS is the key parameter to ensure the safety of the reactor. Several computation and experiment researches on the performance of RCCS have been conducted. There are two types of RCCS depending on its coolant; one is the air-cooled type and the other is water-cooled type. This study focused on the former type. Due to the excessive height of the prototype RCCS, experiment facilities were constructed in reduced scale. Korea Atomic Energy Research Institute (KAERI) constructed the quarter-scale RCCS experiment facility, NACEF and Argonne National Laboratory (ANL) has constructed half-scale experiment facility, NSTF. University of Wisconsin (UW) also has the quarter-scale experiment facility and Texas A and M University has conducted separate effect test on the jet effect at the upper plenum of RCCS. From the reduced scale experiment result, the performance of RCCS such as a heat removal rate of RCCS and a peak temperature of reactor vessel were evaluated. When the reduced-scale result is applied to the prototype, however, a distortion could be brought about due to the reduced height of RCCS in the experiments. Especially, if the heat transfer regime inside the riser which roles as a heat exchanger to discharge the decay heat into the atmosphere is not identical, the riser wall temperature and the consequent reactor vessel temperature of the prototype could be incorrectly predicted. Thus, the convective heat transfer phenomena inside the riser duct both in the reduced scale and in the prototype is necessary to be investigated. In this study, the preliminary analysis on the heat transfer phenomena inside the RCCS riser was conducted. The subjects of the analysis were the prototype RCCS riser of PMR 200, and its scaled-down experiment facilities, NACEF. First, the geometry, flow and thermal conditions of the riser in PMR200 RCCS and NACEF were introduced with a scaling method. And then, the heat transfer regimes and the heat transfer coefficient corresponding to each condition were predicted using correlation and CFD calculation. Finally, planned activities including the experiment was introduced. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Additive Manufacturing for Cost Efficient Production of Compact Ceramic Heat Exchangers and Recuperators

An additive manufacture technique known as laminated object manufacturing (LOM) was used to fabricate compact ceramic heat exchanger prototypes. LOM uses precision CO2 laser cutting of ceramic green tapes, which are then precision stacked to build a 3D object with fine internal features. Modeling was used to develop prototype designs and predict the thermal response, stress, and efficiency in the ceramic heat exchangers. Build testing and materials analyses were used to provide feedback for the design selection. During this development process, laminated object manufacturing protocols were established. This included laser optimization, strategies for fine feature integrity, lamination fluid control, green handling, and firing profile. Three full size prototypes were fabricated using two different designs. One prototype was selected for performance testing. During testing, cross talk leakage prevented the application of a high pressure differential, however, the prototype was successful at withstanding the high temperature operating conditions (1300 °F). In addition, analysis showed that the bulk of the part did not have cracks or leakage issues. This led to the development of a module method for next generation LOM heat exchangers. A scale-up cost analysis showed that given a purpose built LOM system, these ceramic heat exchangers would be affordable for the applications.

01 COAL, LIGNITE, AND PEAT↗

Transitional Bubble in Periodic Flow Phase Shift

One particular characteristic observed in unsteady shear layers is the phase shift relative to the main flow. In attached boundary layers this will have an effect both on the instantaneous skin friction and heat transfer. In separation bubbles the contribution to the drag is dominated by the pressure distribution. However, the most significant effect appears to be the phase shift on the transition process. Unsteady transition behaviour may determine the bursting of the bubble resulting in an un-recoverable full separation. An early analysis of the phase shift was performed by Stokes for the incompressible boundary layer of an oscillating wall and an oscillating main flow. An amplitude overshoot within the shear layer as well as a phase shift were observed that can be attributed to the relatively slow diffusion of viscous stresses compared to the fast change of pressure. Experiments in a low speed facility with the boundary layer of a flat plate were evaluated in respect to phase shift. A pressure distribution similar to that on the suction surface of a turbomachinery aerofoil was superimposed generating a typical transitional separation bubble. A periodically unsteady main flow in the suction type wind tunnel was introduced via a rotating flap downstream of the test section. The experiments covered a range of the three similarity parameters of momentum-loss-thickness Reynolds-number of 92 to 226 and Strouhal-number (reduced frequency) of 0.0001 to 0.0004 at the separation point, and an amplitude range up to 19 %. The free stream turbulence level was less than 1% .Upstream of the separation point the phase shift in the laminar boundary layer does not appear to be affected significantly bay either of the three parameters. The trend perpendicular to the wall is similar to the Stokes analysis. The problem scales well with the wave velocity introduced by Stokes, however, the lag of the main flow near the wall is less than indicated analytically. The separation point comes closest to the Stokes analysis but the phase is still 20 degrees lower at the wall.

Talan, M.↗

Scaling craters in carbonates: Electron paramagnetic resonance analysis of shock damage

Carbonate samples from the 8.9-Mt nuclear (near-surface explosion) crater, OAK, and a terrestrial impact crater, Meteor Crater, were analyzed for shock damage using electron paramagnetic resonance (EPR). Samples from below the OAK apparent crater floor were obtained from six boreholes, as well as ejecta recovered from the crater floor. The degree of shock damage in the carbonate material was assessed by comparing the sample spectra to the spectra of Solenhofen and Kaibab limestone, which had been skocked to known pressures. Analysis of the OAK Crater borehole samples has identified a thin zone of allocthonous highly shocked (10-13 GPa) carbonate material underneath the apparent crater floor. This approx. 5- to 15-m-thick zone occurs at a maximum depth of approx. 125 m below current seafloor at the borehole, sited at the initial position of the OAK explosive, and decreases in depth towards the apparent crater edge. Because this zone of allocthonous shocked rock delineates deformed rock below, and a breccia of mobilized sand and collapse debris above, it appears to outline the transient crater. The transient crater volume inferred in this way is found to by 3.2 +/- 0.2 times 10(exp 6)cu m, which is in good agreement with a volume of 5.3 times 10(exp 6)cu m inferred from gravity scaling of laboratory experiments. A layer of highly shocked material is also found near the surface outside the crater. The latter material could represent a fallout ejecta layer. The ejecta boulders recovered from the present crater floor experienced a range of shock pressures from approx. 0 to 15 GPa with the more heavily shocked samples all occurring between radii of 360 and approx. 600 m. Moreover, the fossil content, lithology and Sr isotopic composition all demonstrate that the initial position of the bulk of the heavily shocked rock ejecta sampled was originally near surface rock at initial depths in the 32 to 45-m depth (below sea level) range. The EPR technique is also sensitive to prehistoric shock damage. This is demonstrated by our study of shocked Kaibab limestone from the 49,000-year-old Meteor (Barringer) Crater Arizona.

Polanskey, Carol A.↗

Variational encoder geostatistical analysis (VEGAS) with an application to large scale riverine bathymetry

Estimation of riverbed profiles, also known as bathymetry, plays a vital role in many applications, such as safe and efficient inland navigation, prediction of bank erosion, land subsidence, and flood risk management. The high cost and complex logistics of direct bathymetry surveys, i.e, depth imaging, have encouraged the use of indirect measurements such as surface flow velocities. However, estimating high-resolution bathymetry from indirect measurements is an inverse problem that can be computationally challenging. Here, we propose a reduced-order model (ROM) based approach that utilizes a variational autoencoder (VAE), a type of deep neural network with a narrow layer in the middle, to compress bathymetry and flow velocity information and accelerate bathymetry inverse problems from flow velocity measurements. In our application, the shallow-water equations (SWE) with appropriate boundary conditions (BCs), e.g., the discharge and/or the free surface elevation, constitute the forward problem, to predict flow velocity. Then, ROMs of the SWEs are constructed on a nonlinear manifold of low dimensionality through a variational encoder and the bathymetry inversion problem is derived on the low-dimensional latent space in a Hierarchical Bayesian setting. Further, the reformulation allows variational inference with a small number (e.g., $\mathscr{O}$ (100) of ROM runs and efficient uncertainty quantification. We have tested our inversion approach on a one-mile reach of the Savannah River, GA, USA. Once the neural network is trained (offline stage), the proposed technique can perform the inversion operation orders of magnitude faster than traditional inversion methods that are commonly based on linear projections, such as principal component analysis (PCA), or the principal component geostatistical approach (PCGA). Furthermore, tests show that the algorithm can estimate the bathymetry with good accuracy even with sparse flow velocity measurements.

54 ENVIRONMENTAL SCIENCES↗

Cost Scaling of a Real-World Exhaust Waste Heat Recovery Thermoelectric Generator: A Deeper Dive

Cost is equally important to power density or efficiency for the adoption of waste heat recovery thermoelectric generators (TEG) in many transportation and industrial energy recovery applications. In many cases the system design that minimizes cost (e.g., the $/W value) can be very different than the design that maximizes the system's efficiency or power density, and it is important to understand the relationship between those designs to optimize TEG performance-cost compromises. Expanding on recent cost analysis work and using more detailed system modeling, an enhanced cost scaling analysis of a waste heat recovery thermoelectric generator with more detailed, coupled treatment of the heat exchangers has been performed. In this analysis, the effect of the heat lost to the environment and updated relationships between the hot-side and cold-side conductances that maximize power output are considered. This coupled thermal and thermoelectric treatment of the exhaust waste heat recovery thermoelectric generator yields modified cost scaling and design optimization equations, which are now strongly dependent on the heat leakage fraction, exhaust mass flow rate, and heat exchanger effectiveness. This work shows that heat exchanger costs most often dominate the overall TE system costs, that it is extremely difficult to escape this regime, and in order to achieve TE system costs of $1/W it is necessary to achieve heat exchanger costs of $1/(W/K). Minimum TE system costs per watt generally coincide with maximum power points, but Preferred TE Design Regimes are identified where there is little cost penalty for moving into regions of higher efficiency and slightly lower power outputs. These regimes are closely tied to previously-identified low cost design regimes. This work shows that the optimum fill factor Fopt minimizing system costs decreases as heat losses increase, and increases as exhaust mass flow rate and heat exchanger effectiveness increase. These findings have profound implications on the design and operation of various thermoelectric (TE) waste heat 3 recovery systems. This work highlights the importance of heat exchanger costs on the overall TEG system costs, quantifies the possible TEG performance-cost domain space based on heat exchanger effects, and provides a focus for future system research and development efforts.

cost analysis↗

Machine Learning for Synchrophasor Analysis

The report presents results from the development of a cloud-based, Big Data analysis framework for power systems. The computational pipeline uses the Apache Spark framework running in an OpenStack cloud infrastructure. A real-world phasor measurement unit (PMU) dataset has been used to carry out the analysis. Several Machine Learning (ML) methods have been developed and implemented for event and anomaly detection and classification. Actual examples of power system events detection and analysis using synchrophasor data are presented. It has been shown that applications of the cloud-based computing environment and the Apache Spark framework enable a significant increase in the computational efficiency of large-scale PMU data analysis.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis of Community Detection Algorithms for Large Scale Cyber Networks

The aim of this project is to use existing community detection algorithms on an IP network dataset to create supernodes within the network. This study compares the performance of different algorithms on the network in terms of running time. The paper begins with an introduction to the concept of clustering and community detection followed by the research question that the team aimed to address. Further the paper describes the graph metrics that were considered in order to shortlist algorithms followed by a brief explanation of each algorithm with respect to the graph metric on which it is based. The next section in the paper describes the methodology used by the team in order to run the algorithms and determine which algorithm is most efficient with respect to running time. Finally, the last section of the paper includes the results obtained by the team and a conclusion based on those results as well as future work.

algorithms↗