Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Dynamically Polarized Sample for Neutron Scattering At the Spallation Neutron Source

The recently constructed Spallation Neutron Source at the Oak Ridge National Laboratory is quickly becoming the world s leader in neutron scattering sciences. In addition to the world s most intense pulsed neutron source, we are continuously constructing state of the art neutron scattering instruments as well as sample environments to address today and tomorrow s challenges in materials research. The Dynamically Polarized Sample project at the SNS is aimed at taking maximum advantage of polarized neutron scattering from polarized samples, especially biological samples that are abundant in hydrogen. Polarized neutron scattering will allow us drastically increase the signal to noise ratio in experiments such as neutron protein crystallography. The DPS project is near its completion and all key components have been tested. Here we report the current status of the project.

Pierce, Josh↗

Rapid Analysis of Carbohydrates in Bioprocess Samples: An Evaluation of the CarboPac SA10 for HPAE-PAD Analysis by Interlaboratory Comparison

A technique for carbohydrate analysis for bioprocess samples has been developed, providing reduced analysis time compared to current practice in the biofuels R&D community. The Thermofisher CarboPac SA10 anion-exchange column enables isocratic separation of monosaccharides, sucrose and cellobiose in approximately 7 minutes. Additionally, use of a low-volume (0.2 mL) injection valve in combination with a high-volume detection cell minimizes the extent of sample dilution required to bring sugar concentrations into the linear range of the pulsed amperometric detector (PAD). Three laboratories, representing academia, industry, and government, participated in an interlaboratory study which analyzed twenty-one opportunistic samples representing biomass pretreatment, enzymatic saccharification, and fermentation samples. The technique's robustness, linearity, and interlaboratory reproducibility were evaluated and showed excellent-to-acceptable characteristics. Additionally, quantitation by the CarboPac SA10/PAD was compared with the current practice method utilizing a HPX-87P/RID. While these two methods showed good agreement a statistical comparison found significant quantitation difference between them, highlighting the difference between selective and universal detection modes.

09 BIOMASS FUELS↗

Surface sampling concentration and reaction probe

A method of analyzing a chemical composition of a specimen is described. The method can include providing a probe comprising an outer capillary tube and an inner capillary tube disposed co-axially within the outer capillary tube, where the inner and outer capillary tubes define a solvent capillary and a sampling capillary in fluid communication with one another at a distal end of the probe; contacting a target site on a surface of a specimen with a solvent in fluid communication with the probe; maintaining a plug volume proximate a solvent-specimen interface, wherein the plug volume is in fluid communication with the probe; draining plug sampling fluid from the plug volume through the sampling capillary; and analyzing a chemical composition of the plug sampling fluid with an analytical instrument. A system for performing the method is also described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SURFACE CHARACTERIZATION OF NIOBIUM SAMPLES ELECTRO-POLISHED TOGETHER WITH REAL CAVITIES

We report the results of surface characterizations of niobium samples electropolished together with single cell cavities. These witness samples were located in three regions of the cavity, namely at the equator, the iris and the beam-pipe. Auger electron spectroscopy (AES) was utilized to probe the chemical composition of the topmost four atomic layers. Scanning electron microscopy with energy dispersive x-ray for elemental analysis (SEM/EDX) was used to observe the surface topography and chemical composition at the micrometer scale. A few atomic layers of sulphur (S) were found covering the samples non-uniformly. Niobium oxide granules with a sharp geometry were observed on every sample. Some Nb-O granules appeared to also contain sulphur.

36 MATERIALS SCIENCE↗

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System and method for measuring fluorescence of a sample

The present disclosure provides a system and a method for measuring fluorescence of a sample. The sample may be a polymerase-chain-reaction (PCR) array, a loop-mediated-isothermal amplification array, etc. LEDs are used to excite the sample, and a photodiode is used to collect the sample's fluorescence. An electronic offset signal is used to reduce the effects of background fluorescence and the noises from the measurement system. An integrator integrates the difference between the output of the photodiode and the electronic offset signal over a given period of time. The resulting integral is then converted into digital domain for further processing and storage.

47 OTHER INSTRUMENTATION↗

Method and system having ultrasonic sensor movable by translation device for ultrasonic profiling of weld samples

A system for ultrasonic profiling of a weld sample includes a carriage movable in opposite first and second directions. An ultrasonic sensor is coupled to the carriage to move over the sample as the carriage moves. An encoder determines the position of the carriage to determine the position of the sensor. A spring is connected at one end of the carriage. Upon the carriage being moved in the first direction toward the spring such that the carriage and the sensor are at a beginning position and the spring is compressed the spring decompresses to push the carriage back along the second direction to move the carriage and the sensor from the beginning position to an ending position. The encoder triggers the sensor to take the ultrasonic measurements of the sample when the sensor is at predetermined positions while the sensor moves over the sample between the beginning and positions.

47 OTHER INSTRUMENTATION↗

Sparse sampling and reconstruction for electron and scanning probe microscope imaging

Systems and methods for conducting electron or scanning probe microscopy are provided herein. In a general embodiment, the systems and methods for conducting electron or scanning probe microscopy with an undersampled data set include: driving an electron beam or probe to scan across a sample and visit a subset of pixel locations of the sample that are randomly or pseudo-randomly designated; determining actual pixel locations on the sample that are visited by the electron beam or probe; and processing data collected by detectors from the visits of the electron beam or probe at the actual pixel locations and recovering a reconstructed image of the sample.

74 ATOMIC AND MOLECULAR PHYSICS↗

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

47 OTHER INSTRUMENTATION↗

Capillary absorption spectrometer and process for isotopic analysis of small samples

A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The method also permits sampling in vivo permitting real-time ambient studies of microbial communities.

47 OTHER INSTRUMENTATION↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate, the first volumetric flow rate exceeding the second volumetric flow rate, wherein liquid at the open end will receive sample, liquid containing sample material will be drawn into and through the liquid exhaust conduit, and liquid will overflow from the open end.

36 MATERIALS SCIENCE↗

System and method for measuring fluorescence of a sample

The present disclosure provides a system and a method for measuring fluorescence of a sample. The sample may be a polymerase-chain-reaction (PCR) array, a loop-mediated-isothermal amplification array, etc. LEDs are used to excite the sample, and a photodiode is used to collect the sample's fluorescence. An electronic offset signal is used to reduce the effects of background fluorescence and the noises from the measurement system. An integrator integrates the difference between the output of the photodiode and the electronic offset signal over a given period of time. The resulting integral is then converted into digital domain for further processing and storage.

47 OTHER INSTRUMENTATION↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate, the first volumetric flow rate exceeding the second volumetric flow rate, wherein liquid at the open end will receive sample, liquid containing sample material will be drawn into and through the liquid exhaust conduit, and liquid will overflow from the open end.

36 MATERIALS SCIENCE↗

Capillary absorption spectrometer and process for isotopic analysis of small samples

A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The process also permits sampling in vivo permitting real-time ambient studies of microbial communities.

47 OTHER INSTRUMENTATION↗

Spatially-resolved HPGe Gamma-ray Spectroscopy of Swipe Samples

Measurement of swipe samples is a critical element of the National Technical Nuclear Forensics (NTNF) mission. A unique, portable, germanium gamma imager (GeGI-s) from PHDS Co may provide complementary information to current techniques for swipe sample screening. The GeGI-s is a modified version of the commercial GeGI-4, a planar HPGe detector, capable of several million counts per second across the whole detector. The GeGI-s detector is a prototype of a commercial off-the-shelf high rate GeGI. The high rate capability allows high-activity samples be placed directly on the face of the detector. Utilizing the high energy resolution and pixelization of the detector, the GeGI-s can generate isotope specific spatial maps of the materials on the swipe sample. To prove this technology is viable for such mapping, the GeGI-s detector response to spatially distributed events must be well characterized. The detection efficiency as a function of location has been characterized to understand the non-uniformities presented as a collimated photon beam was rastered vertically and horizontally across the face of the detector. The detection efficiency as a function of location has been characterized to understand the non-uniformities presented as a collimated photon beam was rastered vertically and horizontally across the face of the detector. The response was found to be primarily uniform and symmetric, however two causes of non-uniformity were found. Both of these causes can ultimately be corrected for in off-line data analysis.

germanium gamma imager↗

Laser-Induced Breakdown Spectroscopy: Application to Powder Samples

Laser-induced breakdown spectroscopy (LIBS) is an atomic emission spectroscopy technique which with the help of a broad band spectrometer can simultaneously perform multi-elemental and in situ analysis of various samples (solid, liquid, powder or gaseous) and various environments which are sometimes difficult to access with standard chemical analytical techniques. In this chapter, we focus on some applications of LIBS on powder samples with varying concentration and how to reduce the matrix effects. By “matrix effect,” we refer to the influence of the physical and chemical properties of the sample on the plasma excitation. The possibility of developing a LIBS based sensor system for total carbon quantification in soil samples is discussed and the feasibility of laser-induced breakdown spectroscopy for the analysis of gasification slag is investigated. The results of these two analyses are compared with those obtained from a carbon analyzer and inductively coupled plasma-optical emission spectroscopy (ICP-OES).

36 MATERIALS SCIENCE↗

Open port sampling interface

A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from the liquid exhaust conduit at a second volumetric flow rate. A droplet dispenser can dispense drops of a sample or a sample-containing solvent into the open end of the housing. A sensor and a processor can be provided to monitor and maintain a liquid dome present at the open end.

Van Berkel, Gary J.↗