Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Application Of Laser Induced Breakdown Spectroscopy (LIBS) Technique In Investigation Of Historical Metal Threads

Analysis of the composition of an object is a necessary step in the documentation of the properties of this object for estimating its condition. Also this is an important task for establishing an appropriate conservation treatment of an object or to follow up the result of the application of the suggested treatments. There has been an important evolution in the methods used for analysis of metal threads since the second half of the twentieth century. Today, the main considerations of selecting a method are based on the diagnostic power, representative sampling, reproducibility, destructive nature/invasiveness of analysis and accessibility to the appropriate instrument. This study aims at evaluating the usefulness of the use of Laser Induced Breakdown Spectroscopy (LIBS) Technique for analysis of historical metal threads. In this study various historical metal threads collected from different museums were investigated using (LIBS) technique. For evaluating usefulness of the suggested analytical protocol of this technique, the same investigated metal thread samples were investigated with Scanning Electron Microscope (SEM) with energy-dispersive x-ray analyzer (EDX) which is reported in conservation field as the best method, to determine the chemical composition, and corrosion of investigated metal threads. The results show that all investigated metal threads in the present study are too dirty, strongly damaged and corroded with different types of corrosion products. Laser Induced Breakdown Spectroscopy (LIBS) Technique is considered very useful technique that can be used safely for investigating historical metal threads. It is, in fact, very useful tool as a noninvasive method for analysis of historical metal threads. The first few laser shots are very useful for the investigation of the corrosion and dirt layer, while the following shots are very useful and effective for investigating the coating layer. Higher number of laser shots are very useful for the main composition of the metal thread. There is a necessity to carry out further research to investigate and determine the most appropriate and effective approaches and methods for conservation of these metal threads.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Applied spectroscopy in pulsed power plasmas

Applied spectroscopy is a powerful diagnostic tool for high energy density plasmas produced with modern pulsed power facilities. These facilities create unique plasma environments with a broad range of electron densities (10{sup 13}-10{sup 23} cm{sup -3}) and temperatures (10{sup 0}-10{sup 3} eV) immersed in strong magnetic (>100 T) and electric (up to 1 GV/m) fields. This paper surveys the application of plasma spectroscopy to diagnose a variety of plasma conditions generated by pulsed power sources including: magnetic field penetration into plasma, measuring the time-dependent spatial distribution of 1 GV/m electric fields, opacity measurements approaching stellar interior conditions, characteristics of a radiating shock propagating at 330 km/s, and determination of plasma conditions in imploded capsule cores at 150 Mbar pressures. These applications provide insight into fundamental properties of nature in addition to their importance for addressing challenging pulsed power science problems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Double conical crystal x-ray spectrometer for high resolution ultrafast x-ray absorption near-edge spectroscopy of Al K edge

An x-ray spectrometer devoted to dynamical studies of transient systems using the x-ray absorption fine spectroscopy technique is presented in this article. Using an ultrafast laser-induced x-ray source, this optical device based on a set of two potassium acid phthalate conical crystals allows the extraction of x-ray absorption near-edge spectroscopy structures following the Al absorption K edge. The proposed experimental protocol leads to a measurement of the absorption spectra free from any crystal reflectivity defaults and shot-to-shot x-ray spectral fluctuation. According to the detailed analysis of the experimental results, a spectral resolution of 0.7 eV rms and relative fluctuation lower than 1% rms are achieved, demonstrated to be limited by the statistics of photon counting on the x-ray detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunable ultrafast extreme ultraviolet source for time- and angle-resolved photoemission spectroscopy

We present a laser-based apparatus suitable for visible pump/extreme UV (XUV) probe time-, energy-, and angle-resolved photoemission spectroscopy utilizing high-harmonic generation from a noble gas. Tunability in a wide range of energies (currently 20-36 eV) is achieved by using a time-delay compensated monochromator, which also preserves the ultrashort duration of the XUV pulses. Using an amplified laser system at 10 kHz repetition rate, approximately 10{sup 9}-10{sup 10} photons/s per harmonic are made available for photoelectron spectroscopy. Parallel energy and momentum detection is carried out in a hemispherical electron analyzer coupled with an imaging detector. First applications demonstrate the capabilities of the instrument to easily select the probe wavelength of choice, to obtain angle-resolved photoemission maps (GaAs and URu{sub 2}Si{sub 2}), and to trace ultrafast electron dynamics in an optically excited semiconductor (Ge).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated analysis and consistency measurement of bremsstrahlung and charge exchange spectroscopy data for the determination of the ion effective charge

In the context of Bayesian probability theory, we discuss a model for estimating the plasma ion effective charge Z{sub eff}, integrating data from both bremsstrahlung spectroscopy and individual impurity concentrations obtained via charge exchange spectroscopy (CXS). The validity of the model, taking into account statistical as well as systematic uncertainties, is shown via the deviance information criterion. The consistency of the continuum and CXS data regarding Z{sub eff} is improved, as measured by the symmetrized Kullback-Leibler divergence and the geodesic distance between the respective Z{sub eff} marginal posterior densities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An integrated charge exchange recombination spectroscopy/beam emission spectroscopy diagnostic for Alcator C-Mod tokamak

A novel integrated charge exchange recombination spectroscopy (CXRS)/beam emission spectroscopy (BES) system is proposed for C-Mod, in which both measurements are taken from a shared viewing geometry. The supplementary BES system serves to quantify local beam densities and supplants the common calculation of beam attenuation. The new system employs two optical viewing arrays, 20 poloidal and 22 toroidal channels. A dichroic filter splits the light between two spectrometers operating at different wavelengths for impurity ion and beam neutrals emission. In this arrangement, the impurity density is inferred from the electron density, measured BES and CXRS spectral radiances, and atomic emission rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution, low h{nu} photoelectron spectroscopy with the use of a microwave excited rare gas lamp and ionic crystal filters

The need for not only bulk sensitive but also extremely high resolution photoelectron spectroscopy for studying detailed electronic structures of strongly correlated electron systems is growing rapidly. Moreover, easy access to such a capability in one's own laboratory is desirable. Demonstrated here is the performance of a microwave excited rare gas (Xe, Kr, and Ar) lamp combined with ionic crystal filters (sapphire, CaF{sub 2}, and LiF), which can supply three strong lines near the photon energy of hnyu h{nu}=8.4, 10.0, and 11.6 eV, with the h{nu} resolution of better than 600 {mu}eV for photoelectron spectroscopy. Its performance is demonstrated on some materials by means of both angle-integrated and angle-resolved measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond laser-induced crystallization of amorphous Sb{sub 2}Te{sub 3} film and coherent phonon spectroscopy characterization and optical injection of electron spins

A femtosecond laser-irradiated crystallizing technique is tried to convert amorphous Sb{sub 2}Te{sub 3} film into crystalline film. Sensitive coherent phonon spectroscopy (CPS) is used to monitor the crystallization of amorphous Sb{sub 2}Te{sub 3} film at the original irradiation site. The CPS reveals that the vibration strength of two phonon modes that correspond to the characteristic phonon modes (A{sub 1g}{sup 1} and E{sub g}) of crystalline Sb{sub 2}Te{sub 3} enhances with increasing laser irradiation fluence (LIF), showing the rise of the degree of crystallization with LIF and that femtosecond laser irradiation is a good post-treatment technique. Time-resolved circularly polarized pump-probe spectroscopy is used to investigate electron spin relaxation dynamics of the laser-induced crystallized Sb{sub 2}Te{sub 3} film. Spin relaxation process indeed is observed, confirming the theoretical predictions on the validity of spin-dependent optical transition selection rule and the feasibility of transient spin-grating-based optical detection scheme of spin-plasmon collective modes in Sb{sub 2}Te{sub 3}-like topological insulators.

36 MATERIALS SCIENCE↗

Continuous-time photon-stimulated desorption spectroscopy studies on soft x-ray-induced reactions of CF{sub 3}Br adsorbed on Si(111)-7x7

Continuous-time core-level photon-stimulated desorption (PSD) spectroscopy was used to study the soft x-ray-induced reactions of CF{sub 3}Br molecules adsorbed on Si(111)-7x7 near the Si(2p) edge (98-110 eV). The monochromatic synchrotron radiation was employed as a soft x-ray light source in the photon-induced reactions and also as a probe for investigating the produced fluorination states of the bonding surface Si atom in the positive-ion PSD spectroscopy. Several different surface coverages were investigated. The PSD spectra from the low-CF{sub 3}Br-covered surfaces show the production of surface SiF species, while those from the high-CF{sub 3}Br-covered surfaces depict the formation of surface SiF, SiF{sub 2}, and SiF{sub 3} species. The photolysis cross section of the submonolayer CF{sub 3}Br-covered surface is determined as {approx}4.3x10{sup -18} cm{sup 2}. A comparison with the results on CF{sub 3}Cl/Si(111)-7x7 surface is discussed.

36 MATERIALS SCIENCE↗

Measurement of axial neutral density profiles in a microwave discharge ion thruster by laser absorption spectroscopy with optical fiber probes

In order to reveal the physical processes taking place within the ''{mu}10'' microwave discharge ion thruster, internal plasma diagnosis is indispensable. However, the ability of metallic probes to access microwave plasmas biased at a high voltage is limited from the standpoints of the disturbance created in the electric field and electrical isolation. In this study, the axial density profiles of excited neutral xenon were successfully measured under ion beam acceleration by using a novel laser absorption spectroscopy system. The target of the measurement was metastable Xe I 5p{sup 5}({sup 2}P{sup 0}{sub 3/2})6s[{sup 3}/{sub 2}]{sup 0}{sub 2} which absorbed a wavelength of 823.16 nm. Signals from laser absorption spectroscopy that swept a single-mode optical fiber probe along the line of sight were differentiated and converted into axial number densities of the metastable neutral particles in the plasma source. These measurements revealed a 10{sup 18} m{sup -3} order of metastable neutral particles situated in the waveguide, which caused two different modes during the operation of the {mu}10 thruster. This paper reports a novel spectroscopic measurement system with axial resolution for microwave plasma sources utilizing optical fiber probes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beams, brightness, and background: Using active spectroscopy techniques for precision measurements in fusion plasma research

The use of an injected neutral beam-either a dedicated diagnostic beam or the main heating beams-to localize and enhance plasma spectroscopic measurements can be exploited for a number of key physics issues in magnetic confinement fusion research, yielding detailed profile information on thermal and fast ion parameters, the radial electric field, plasma current density, and turbulent transport. The ability to make these measurements has played a significant role in much of our recent progress in the scientific understanding of fusion plasmas. The measurements can utilize emission from excited state transitions either from plasma ions or from the beam atoms themselves. The primary requirement is that the beam 'probe' interacts with the plasma in a known fashion. Advantages of active spectroscopy include high spatial resolution due to the enhanced localization of the emission and the use of appropriate imaging optics, background rejection through the appropriate modulation and timing of the beam and emission collection/detection system, and the ability of the beam to populate emitter states that are either nonexistent or too dim to utilize effectively in the case of standard or passive spectroscopy. In addition, some active techniques offer the diagnostician unique information because of the specific quantum physics responsible for the emission. This paper will describe the general principles behind a successful active spectroscopic measurement, emphasize specific techniques that facilitate the measurements and include several successful examples of their implementation, briefly touching on some of the more important physics results. It concludes with a few remarks about the relevance and requirements of active spectroscopic techniques for future burning plasma experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge exchange recombination spectroscopy on fusion devices

For fusion, obtaining reliable measurements of basic plasma parameters like ion and electron densities and temperatures is a primary goal. For theory, measurements are needed as a function of time and space to understand plasma transport and confinement with the ultimate goal of achieving economic nuclear fusion power. Electron profile measurements and plasma spectroscopy for the plasma ions are introduced. With the advent of Neutral Beam auxiliary plasma heating, Charge Exchange Recombination Spectroscopy provides accurate and time resolved measurements of the ions in large volume fusion devices. In acknowledgement of Nicol Peacock's role in the development of these techniques, still at the forefront of plasma fusion research, this paper describes the evolution of this diagnostic method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A high etendue spectrometer suitable for core charge eXchange recombination spectroscopy on ITER

A feasibility study for the use of core charge exchange recombination spectroscopy on ITER has shown that accurate measurements on the helium ash require a spectrometer with a high etendue of 1mm{sup 2}sr to comply with the measurement requirements [S. Tugarinov et al., Rev. Sci. Instrum. 74, 2075 (2003)]. To this purpose such an instrument has been developed consisting of three separate wavelength channels (to measure simultaneously He/Be, C/Ne, and H/D/T together with the Doppler shifted direct emission of the diagnostic neutral beam, the beam emission (BES) signal), combining high dispersion (0.02 nm/pixel), sufficient resolution (0.2 nm), high efficiency (55%), and extended wavelength range (14 nm) at high etendue. The combined measurement of the BES along the same sightline within a third wavelength range provides the possibility for in situ calibration of the charge eXchange recombination spectroscopy signals. In addition, the option is included to use the same instrument for measurements of the fast fluctuations of the beam emission intensity up to 2 MHz, with the aim to study MHD activity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method to obtain absolute impurity density profiles combining charge exchange and beam emission spectroscopy without absolute intensity calibration

Investigation of impurity transport properties in tokamak plasmas is essential and a diagnostic that can provide information on the impurity content is required. Combining charge exchange recombination spectroscopy (CXRS) and beam emission spectroscopy (BES), absolute radial profiles of impurity densities can be obtained from the CXRS and BES intensities, electron density and CXRS and BES emission rates, without requiring any absolute calibration of the spectra. The technique is demonstrated here with absolute impurity density radial profiles obtained in TEXTOR plasmas, using a high efficiency charge exchange spectrometer with high etendue, that measures the CXRS and BES spectra along the same lines-of-sight, offering an additional advantage for the determination of absolute impurity densities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced experimental applications for x-ray transmission gratings spectroscopy using a novel grating fabrication method

A novel fabrication method for soft x-ray transmission grating and other optical elements is presented. The method uses focused-ion-beam technology to fabricate high-quality free standing grating bars on transmission electron microscopy grids. High quality transmission gratings are obtained with superb accuracy and versatility. Using these gratings and back-illuminated CCD camera, absolutely calibrated x-ray spectra can be acquired for soft x-ray source diagnostics in the 100-3000 eV spectral range. Double grating combinations of identical or different parameters are easily fabricated, allowing advanced one-shot application of transmission grating spectroscopy. These applications include spectroscopy with different spectral resolutions, bandwidths, dynamic ranges, and may serve for identification of high-order contribution, and spectral calibrations of various x-ray optical elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved multiple probe spectroscopy

Time-resolved multiple probe spectroscopy combines optical, electronic, and data acquisition capabilities to enable measurement of picosecond to millisecond time-resolved spectra within a single experiment, using a single activation pulse. This technology enables a wide range of dynamic processes to be studied on a single laser and sample system. The technique includes a 1 kHz pump, 10 kHz probe flash photolysis-like mode of acquisition (pump-probe-probe-probe, etc.), increasing the amount of information from each experiment. We demonstrate the capability of the instrument by measuring the photolysis of tungsten hexacarbonyl (W(CO){sub 6}) monitored by IR absorption spectroscopy, following picosecond vibrational cooling of product formation through to slower bimolecular diffusion reactions on the microsecond time scale.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beta-decay spectroscopy relevant to the r-process nucleosynthesis

A scientific program of beta-decay spectroscopy relevant to r-process nucleosynthesis has been started using high intensity U-beam at the RIBF. The first results of {beta}-decay half-lives of very neutron-rich Kr to Tc nuclides, all of which lie close to the r-process path, suggest a systematic enhancement of the the {beta}-decay rates of the Zr and Nb isotopes around A110 with respect to the predictions of the deformed quasiparticle-random-phase-approximation model (FRDM + QRPA). An impact of the results on the astrophysical r-process is discussed together with the future perspective of the {beta}-decay spectroscopy with the EURICA.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

{gamma} spectroscopy around doubly magic {sup 48}Ca by heavy-ion transfer reactions

{gamma} spectroscopy of neutron-rich nuclei around {sup 48}Ca is performed by the heavy-ion transfer reaction {sup 48}Ca on {sup 64}Ni at 282 MeV, with the PRISMA-CLARA setup at Legnaro Laboratory. Angular distributions, polarizations and lifetimes analysis probe spin and parities of several excited states, shading lights on their configuration. In the one neutron transfer channels, {sup 49}Ca and {sup 47}Ca, states arising by coupling a single particle to the 3{sup -} phonon of {sup 48}Ca are observed, showing the robustness of nuclear collectivity in rather light systems. The work demonstrates the feasibility of complete in-beam {gamma}-spectroscopy with heavy-ion transfer reactions and provides a method that can be further exploited in the future with heavy targets and radioactive beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗