Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Errors in particle tracking velocimetry with high-speed cameras

Velocity errors in particle tracking velocimetry (PTV) are studied. When using high-speed video cameras, the velocity error may increase at a high camera frame rate. This increase in velocity error is due to particle-position uncertainty, which is one of the two sources of velocity errors studied here. The other source of error is particle acceleration, which has the opposite trend of diminishing at higher frame rates. Both kinds of errors can propagate into quantities calculated from velocity, such as the kinetic temperature of particles or correlation functions. As demonstrated in a dusty plasma experiment, the kinetic temperature of particles has no unique value when measured using PTV, but depends on the sampling time interval or frame rate. It is also shown that an artifact appears in an autocorrelation function computed from particle positions and velocities, and it becomes more severe when a small sampling-time interval is used. Schemes to reduce these errors are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of dehydration on the position of cesium cations in the structure of CsNaFAU(Y) studied by powder X-ray diffraction and magic-angle spinning NMR spectroscopy

The influence of dehydration on the position of sodium and cesium cations obtained by ion exchange in the structure of FAU(Y) was studied by powder X-ray diffraction using synchrotron radiation and {sup 23}Na and {sup 133}Cs magic-angle spinning NMR spectroscopy. The sodium and cesium cations were found to be mobile in the hydrated samples. In dehydrated zeolites CsNaFAU(Y), cesium is predominantly localized in four crystallographic ion-exchange positions located in the large cavities and sodalite cages.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An interchangeable scanning Hall probe/scanning SQUID microscope

We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE FAR-INFRARED, UV, AND MOLECULAR GAS RELATION IN GALAXIES UP TO z = 2.5

We use the infrared excess (IRX) FIR/UV luminosity ratio to study the relation between the effective UV attenuation (A {sub IRX}) and the UV spectral slope ({beta}) in a sample of 450 1 < z < 2.5 galaxies. The FIR data are from very deep Herschel observations in the GOODS fields that allow us to detect galaxies with star formation rates (SFRs) typical of galaxies with log(M {sub *}) > 9.3. Thus, we are able to study galaxies on and even below the main SFR-stellar mass relation (main sequence). We find that main-sequence galaxies form a tight sequence in the IRX-{beta} plane, which has a flatter slope than commonly used relations. This slope favors a Small-Magellanic-Cloud-like UV extinction curve, though the interpretation is model dependent. The scatter in the A {sub IRX}-{beta} plane correlates with the position of the galaxies in the SFR-M {sub *} plane. Using a smaller sample of galaxies with CO gas masses, we study the relation between the UV attenuation and the molecular gas content. We find a very tight relation between the scatter in the IRX-{beta} plane and the specific attenuation S{sub A} , a quantity that represents the attenuation contributed by the molecular gas mass per young star. S{sub A} is sensitive to both the geometrical arrangement of stars and dust and to the compactness of the star-forming regions. We use this empirical relation to derive a method for estimating molecular gas masses using only widely available integrated rest-frame UV and FIR photometry. The method produces gas masses with an accuracy between 0.12 and 0.16 dex in samples of normal galaxies between z {approx} 0 and z {approx} 1.5. Major mergers and submillimeter galaxies follow a different S{sub A} relation.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of probe sampling on reacting species measurement in diluted combustion

In-flame measurements of temperature and major species are realized with intrusive probes in a laboratory scale furnace working in diluted combustion. The shape and the position of the reaction zone are experimentally identified from the distribution of temperature and carbon monoxide in a particular symmetry plane. For this purpose, two probes were designed: the sampling probe, to measure species content of the gas sample and the suction pyrometer, for the temperature. The first is completely cooled to quench the reaction, but the second is just partly cooled for handling. However, as both probes take gas sample, the species content is available in either case. Consequently the suction pyrometer can be used to measure simultaneously temperature and species, reducing by half the length of the experimental campaign. Comparing species contents on a non-reactive mixture, it has been observed that the spatial averaging is the same with both probes. The perturbation of the flow is assessed thanks to a CFD modeling of the furnace including the probe. Even if it is significant - the differences between the computed values and the measurements are about 3-4 times the measurement error - the position and the value of the maximum is well captured as well as the opening of the jet. However, the species contents measured within a reactive mixture differ significantly. For a stable regime, the levels and the distribution of CO are similar with both probes, but the gradients at the border of the reaction zone are sharper with the suction pyrometer. For another regime, for which the reaction zone is lifted and less stable, the fields of species are completely different following the probe used. A chemical kinetic modeling has shown that the reaction inside the non-cooled part of the suction pyrometer is promoted when it is placed in particular region. The use of the suction pyrometer as sampling probe inside a reaction zone should therefore be avoided even in diluted combustion. The error made on the fields of species cannot be quantified to be taken into account a posteriori, because in certain conditions the results are completely unrealistic. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effect of litchi juice on exopolysaccharide production in milk fermented by Lactobacillus casei

Summary In this paper, Lactobacillus casei growth, sugar utilisation, exopolysaccharides ( EPS s) formation and EPS s characterisation during fermentation of milk with or without litchi juice were evaluated. During L. casei fermentation of litchi‐milk samples, the EPS s content increased with the increase of litchi juice levels (0–25%, v/v), and the both relationship appeared in S ‐type curve. The viscosity of fermented milk also significantly increased with the formation of EPS s, and which positively correlated with the EPS s content ( R 2 = 0.9782). The EPS s from the fermented litchi‐milk samples was isolated for further structural characterisation. Monosaccharide and molecular weight analysis of purified EPS s sample proved that it contained no carbohydrate other than glucose, and its molecular weight was calibrated as 3.03 × 10 6 Da. FT ‐ IR and NMR ( 1 H and 13 C) spectroscopy analysis confirmed the synthesised EPS s sample was α‐glucans (dextrans) with mainly α‐(1→6) linkages. To the best of our knowledge, this is the first study to report that litchi juice can enhance the EPS s (dextrans, mainly α‐(1→6) linkages) production in fermented milk.

Yu, Yuanshan↗

Synthesis, characterization and catalytic activity of indium substituted nanocrystalline Mobil Five (MFI) zeolite

Highlights: • In situ modification of the MFI zeolite by incorporation of indium. • The samples were characterized by XRD, FTIR, TGA, UV–vis (DRS), SAA, EDX and SEM. • The incorporation of indium was confirmed by XRD, FT-IR, UV–vis (DRS), EDX and TGA. • Hydroxylation of phenol reaction was studied on the synthesized catalysts. - Abstract: A series of indium doped Mobil Five (MFI) zeolite were synthesized hydrothermally with silicon to aluminium and indium molar ratio of 100 and with aluminium to indium molar ratios of 1:1, 2:1 and 3:1. The MFI zeolite phase was identified by XRD and FT-IR analysis. In XRD analysis the prominent peaks were observed at 2θ values of around 6.5° and 23° with a few additional shoulder peaks in case of all the indium incorporated samples suggesting formation of pure phase of the MFI zeolite. All the samples under the present investigation were found to exhibit high crystallinity (∼92%). The crystallite sizes of the samples were found to vary from about 49 to 55 nm. IR results confirmed the formation of MFI zeolite in all cases showing distinct absorbance bands near 1080, 790, 540, 450 and 990 cm{sup −1}. TG analysis of In-MFI zeolites showed mass losses in three different steps which are attributed to the loss due to adsorbed water molecules and the two types TPA{sup +} cations. Further, the UV–vis (DRS) studies reflected the position of the indium metal in the zeolite framework. Surface area analysis of the synthesized samples was carried out to characterize the synthesized samples The analysis showed that the specific surface area ranged from ∼357 to ∼361 m{sup 2} g{sup −1} and the pore volume of the synthesized samples ranged from 0.177 to 0.182 cm{sup 3} g{sup −1}. The scanning electron microscopy studies showed the structure of the samples to be rectangular and twinned rectangular shaped. The EDX analysis was carried out for confirmation of Si, Al and In in zeolite frame work. The catalytic activities of the synthesized samples were investigated with respect to hydroxylation of phenol, in which catechol and hydroquinone were found to be the major products. It is observed that under all reaction conditions catechol selectivity was higher than the hydroquinone selectivity. In-MFI zeolites were successfully synthesized and were used as an effective catalyst for the hydroxylation of phenol to synthesize catechol and hydroquinone as the major product.

36 MATERIALS SCIENCE↗

Observation of N-rich solid-electrolyte interphase by ToF-SIMS.

Formation of a stable solid electrolyte interphase (SEI) between lithium electrodes and electrolyte upon multiple charge/discharge cycles is crucial to a long-term lithium-ion battery performance. Addition of LiNO3 to lithium bis (fluorosulfonyl) imide/poly(ethylene oxide) (LiFSI/PEO) electrolyte leads to a durable SEI that is electrically insulating yet highly conductive to Li ions, chemically and electrochemically stable, physically uniform, and mechanically robust. ToF-SIMS was used here in combination with sputtering by a gaseous cluster ion beam (GCIB) to examine how the addition of a small proportion of LiNO3 to the LiFSI/PEO electrolyte affects the SEI composition. Negative ion ToF-SIMS spectra of the cycled samples display an intense m/z 26 peak associated with the SEI. Exact mass assignments and isotopic ratios indicate that this peak should be assigned as (CN-)-C-12, with little to no negative secondary ion signal arising from (LiF-)-Li-7. This CN- signal appears to arise from an N-rich portion of the SEI adjacent to the Li electrode that is depleted in LiF relative to the bulk electrolyte. The dearth of LiF- (and LiF+ from the positive ion spectra) is unexpected because LiF has been identified in the SEI in similar samples. Finally, GCIB sputtering indicates that the SEI adheres more strongly to the Li electrode than to the LiFSI/PEO electrolyte.

Shavandi, Seyedeh Reyhaneh↗

Ghost marker detection and elimination in marker-based optical tracking systems for real-time tracking in stereotactic body radiotherapy

Purpose: To propose a simple model to explain the origin of ghost markers in marker-based optical tracking systems (OTS) and to develop retrospective strategies to detect and eliminate ghost markers. Methods: In marker-based OTS, ghost markers are virtual markers created due to the cross-talk between the two camera sensors, which can lead to system execution failure or inaccuracy in patient tracking. As a result, the users have to limit the number of markers and avoid certain marker configurations to reduce the chances of ghost markers. In this work, the authors propose retrospective strategies to detect and eliminate ghost markers. The two camera sensors were treated as mathematical points in space. The authors identified the coplanar within limit (CWL) condition as the necessary condition for ghost marker occurrence. A simple ghost marker detection method was proposed based on the model. Ghost marker elimination was achieved through pattern matching: a ghost marker-free reference set was matched with the optical marker set observed by the OTS; unmatched optical markers were eliminated as either ghost markers or misplaced markers. The pattern matching problem was formulated as a constraint satisfaction problem (using pairwise distances as constraints) and solved with an iterative backtracking algorithm. Wildcard markers were introduced to address missing or misplaced markers. An experiment was designed to measure the sensor positions and the limit for the CWL condition. The ghost marker detection and elimination algorithms were verified with samples collected from a five-marker jig and a nine-marker anthropomorphic phantom, rotated with the treatment couch from −60° to +60°. The accuracy of the pattern matching algorithm was further validated with marker patterns from 40 patients who underwent stereotactic body radiotherapy (SBRT). For this purpose, a synthetic optical marker pattern was created for each patient by introducing ghost markers, marker position uncertainties, and marker displacement. Results: The sensor positions and the limit for the CWL condition were measured with excellent reproducibility (standard deviation ≤ 0.39 mm). The ghost marker detection algorithm had perfect detection accuracy for both the jig (1544 samples) and the anthropomorphic phantom (2045 samples). Pattern matching was successful for all samples from both phantoms as well as the 40 patient marker patterns. Conclusions: The authors proposed a simple model to explain the origin of ghost markers and identified the CWL condition as the necessary condition for ghost marker occurrence. The retrospective ghost marker detection and elimination algorithms guarantee complete ghost marker elimination while providing the users with maximum flexibility in selecting the number of markers and their configuration to meet their clinic needs.

60 APPLIED LIFE SCIENCES↗

Realistic application of short-lived fission product delayed neutron, gamma-ray analysis for simultaneous nondestructive trace quantification of U, Pu mixtures on cellulose swipes

Detection and characterization of fissile traces are of interest to the international nuclear nonproliferation community, including the International Atomic Energy Agency. Pre-inspection check samples are analyzed by neutron activation analysis at the High Flux Isotope Reactor operated by the Oak Ridge National Laboratory under the umbrella of the IAEA Network of Analytical Laboratories. The simultaneous quantification of U and Pu mixtures was accomplished using the combined delayed neutron (DN) delayed gamma-ray (DG) method to analyze cellulose swipes with actinide loading <1ng in a blind field trial. The total fissile quantity was measured by the DN counts and the relative proportions of U, Pu were determined by calibration of the 104 Tc / 141 Ba fission product count ratio using known mixtures. The DNDG method demonstrated high accuracy in flagging the presence of 239 Pu in uranium down to <100 pg mass loading. In conclusion, peak significance tests helped to control false positive Pu flagging and simultaneous quantification of U and Pu loading was accomplished on samples that passed the significance tests.

36 MATERIALS SCIENCE↗

Effects of thickness and orientation on the small scale fracture behaviour of additively manufactured Ti-6Al-4V

Highlights: • Miniaturized specimens successfully additively manufactured via SLM and SEBM. • Small-scale tensile testing of specimens to capture orientation/thickness effect. • Tomography characterization of defects. • Location dependence of fracture behavior. - Abstract: The effects of sample location, orientation, and thickness on the microstructure and resulting tensile properties of miniature SLM and SEBM AM samples of Ti-6Al-4V has been determined. Microstructure and mechanical property variations in the miniature samples are shown to be related to build orientation and also partly to specimen thickness and position within the build chamber. The present work is our initial attempt to develop a systematic approach for characterization of the microstructure (including defects via tomography) and mechanical properties on miniature AM test specimens that can also be used to reveal issues related to process stability (e.g. fluctuations in build conditions). The discussion is also included regarding their relevance to miniature samples that can be manufactured along with parts, excised from larger samples, and/or excised from actual manufactured components.

36 MATERIALS SCIENCE↗

Rapid sampling of stochastic displacements in Brownian dynamics simulations

Here, we present a new method for sampling stochastic displacements in Brownian Dynamics (BD) simulations of colloidal scale particles. The method relies on a new formulation for Ewald summation of the Rotne-Prager-Yamakawa (RPY) tensor, which guarantees that the real-space and wave-space contributions to the tensor are independently symmetric and positive-definite for all possible particle configurations. Brownian displacements are drawn from a superposition of two independent samples: a wave-space (far-field or long-ranged) contribution, computed using techniques from fluctuating hydrodynamics and non-uniform fast Fourier transforms; and a real-space (near-field or short-ranged) correction, computed using a Krylov subspace method. The combined computational complexity of drawing these two independent samples scales linearly with the number of particles. The proposed method circumvents the super-linear scaling exhibited by all known iterative sampling methods applied directly to the RPY tensor that results from the power law growth of the condition number of tensor with the number of particles. For geometrically dense microstructures (fractal dimension equal three), the performance is independent of volume fraction, while for tenuous microstructures (fractal dimension less than three), such as gels and polymer solutions, the performance improves with decreasing volume fraction. This is in stark contrast with other related linear-scaling methods such as the force coupling method and the fluctuating immersed boundary method, for which performance degrades with decreasing volume fraction. Calculations for hard sphere dispersions and colloidal gels are illustrated and used to explore the role of microstructure on performance of the algorithm. In practice, the logarithmic part of the predicted scaling is not observed and the algorithm scales linearly for up to 4×10 6 particles, obtaining speed ups of over an order of magnitude over existing iterative methods, and making the cost of computing Brownian displacements comparable to the cost of computing deterministic displacements in BD simulations. Finally, a high-performance implementation employing non-uniform fast Fourier transforms implemented on graphics processing units and integrated with the software package HOOMD-blue is used for benchmarking.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of portable air samplers for monitoring airborne culturable bacteria

Airborne culturable bacteria were monitored at five locations (three in an office/laboratory building and two in a private residence) in a series of experiments designed to compare the efficiency of four air samplers: the Andersen two-stage, Burkard portable, RCS Plus, and SAS Super 90 samplers. A total of 280 samples was collected. The four samplers were operated simultaneously, each sampling 100 L of air with collection on trypticase soy agar. The data were corrected by applying positive hole conversion factors for the Burkard portable, Andersen two-stage, and SAS Super 90 air samplers, and were expressed as log10 values prior to statistical analysis by analysis of variance. The Burkard portable air sampler retrieved the highest number of airborne culturable bacteria at four of the five sampling sites, followed by the SAS Super 90 and the Andersen two-stage impactor. The number of bacteria retrieved by the RCS Plus was significantly less than those retrieved by the other samplers. Among the predominant bacterial genera retrieved by all samplers were Staphylococcus, Bacillus, Corynebacterium, Micrococcus, and Streptococcus.

NASA Center JSC↗

Fatigue damage study in aluminum-2024 T3 alloys

The grain structure of aluminum 2024, a commonly used commercial alloy is investigated, and these findings are correlated with the fatigue property of the material. Samples of aluminum 2024 were polished and etched in different reagents. Optical micrographs (at 500X) of samples etched in Keller's reagent revealed grain boundaries as well as some particles present in the microstructure. Normal x-ray scans of samples etched for different intervals of time in Keller's reagent indicate no significant variations in diffraction peak positions; however, the width of the rocking curve increased with the time of etching. These results are consistent with the direct dependence of the width of the rocking curve on the range of grain orientation. Etching removes the preferred orientation layer of the sample produced by polishing; thereby, causing the width to increase.

Ferguson, Milton W.↗

Surface erythemal UV irradiance in the continental United States derived from ground-based and OMI observations: quality assessment, trend analysis and sampling issues

Surface full-sky erythemal dose rate (EDR) from the Ozone Monitoring Instrument (OMI) at both satellite overpass time and local noon time is evaluated against ground measurements at 31 sites from the US Department of Agriculture's (USDA) UV-B Monitoring and Research Program (UVMRP) over the period of 2005–2017. We find that both OMI overpass and solar noon time EDR are highly correlated with the measured counterparts (with a linear correlation coefficient of 0.90 and 0.88, respectively). Although the comparison statistics are improved with a longer time window (0.5–1.0 h) for pairing surface and OMI measurements, both OMI overpass and local noon time EDRs have 7 % overestimation that is larger than 6 % uncertainty in the ground measurements and show different levels of dependence on solar zenith angle (SZA) and to lesser extent on cloud optical depth. The ratio of EDR between local noon and OMI overpass time is often (95 % in frequency) larger than 1 with a mean of 1.18 in the OMI product; in contrast, the same ratio from surface observation is normally distributed with 22 % of the times less than 1 and a mean of 1.38. This contrast in part reflects the deficiency in the OMI surface UV algorithm that assumes constant atmospheric conditions between overpass and noon time. The probability density functions (PDFs) for both OMI and ground measurements of noontime EDR are in statistically significant agreement, showing dual peaks at ∼20 and ∼200 mW/sq. m, respectively; the latter is lower than 220 mW/ sq. m, the value at which the PDF of daily EDR from ground measurements peaks, and this difference indicates that the largest EDR value for a given day may not often occur at local noon. Lastly, statistically significant positive trends of EDR are found in the northeastern US in OMI data, but opposite trends are found within ground-based data (regardless of sampling for either noontime or daily averages). While positive trends are consistently found between OMI and surface data for EDR over the southern Great Plains (Texas and Oklahoma), their values are within the uncertainty of ground measurements. Overall, no scientifically sound trends can be found among OMI data for aerosol total and absorbing optical depth, cloud optical depth and total ozone to explain coherently the surface UV trends revealed either by OMI or ground-based estimates; these data also cannot reconcile trend differences between the two estimates (of EDR from OMI and surface observations). Future geostationary satellites with better spatiotemporal resolution data should help overcome spatiotemporal sampling issues inherent in OMI data products and therefore improve the estimates of surface UV flux and EDR from space.

Ozone Monitoring Instrument (OMI)↗

False-negative rate, limit of detection and recovery efficiency performance of a validated macrofoam-swab sampling method for low surface concentrations of Bacillus anthracis Sterne and Bacillus atrophaeus spores

The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in × 2 in) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS and 40.2% with BG) and the highest for glass (92.8% with BAS and 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG; values increased as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results will be discussed in a subsequent article.

Bacillus anthracis↗

Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in. × 2 in.) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm 2 , where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results will be discussed in a subsequent report.

59 BASIC BIOLOGICAL SCIENCES↗

Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in × 2 in) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results are discussed in a separate report.

59 BASIC BIOLOGICAL SCIENCES↗