Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

MELT POOL MONITORING FOR CONTROL AND DATA ANALYTICS IN LARGE-SCALE METAL ADDITIVE MANUFACTURING

Laser-wire based Directed Energy Deposition (DED) processes are being developed at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility, in collaboration with GKN Aerospace, for large volume metal additive manufacturing of metallic structures. The technology has the potential to deliver reduced costs and lead times when compared to conventional methods of manufacturing in several industries. While complex structures are being produced with relatively high deposition rates and at near-net shape, issues persist with achieving consistent geometric accuracy and thermal stability. A significant research effort is focused on developing coordinated, multi-modal sensing and control for addressing these issues. An introduction to this large-volume metal process will be provided, followed by investigations into real-time thermal monitoring capabilities that support control and data analytics frameworks. Studies focused on melt pool monitoring via infrared thermography, thermal and geometric effects on melt pool size measurement, and interactions between process variables and thermal monitoring metrics are presented.

Gibson, Brian↗

Automated Vehicle Detection in a Nuclear Facility Using Low-Frequency Acoustic Sensors

This article presents an analysis of the method of construction and results for a classifier intended to identify vehicles using low-frequency acoustic data collected by a dis-tributed sensor network. This data is collected as part of a venture intended to explore data analytics and multisensor fusion techniques for the monitoring of activities at a test bed nuclear facility located at Oak Ridge National Laboratory in Oak Ridge, Tennessee. We describe the associated target signature and design a classifier based on a multilayer perceptron, followed by an analysis of its results. We discuss how overall accuracy is not the only consideration in constructing this classifier, and how for this application, it is actually desirable to operate at a lower level of accuracy in exchange for a reduction in the false alarm rate, as well as how this relates to the actual deployment of the classifier in practical use.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

SU-E-T-50: Automatic Validation of Megavoltage Beams Modeled for Clinical Use in Radiation Therapy

Purpose: To automatically validate megavoltage beams modeled in XiO™ 4.50 (Elekta, Stockholm, Sweden) and Varian Eclipse™ Treatment Planning Systems (TPS) (Varian Associates, Palo Alto, CA, USA), reducing validation time before beam-on for clinical use. Methods: A software application that can automatically read and analyze DICOM RT Dose and W2CAD files was developed using MatLab integrated development environment.TPS calculated dose distributions, in DICOM RT Dose format, and dose values measured in different Varian Clinac beams, in W2CAD format, were compared. Experimental beam data used were those acquired for beam commissioning, collected on a water phantom with a 2D automatic beam scanning system.Two methods were chosen to evaluate dose distributions fitting: gamma analysis and point tests described in Appendix E of IAEA TECDOC-1583. Depth dose curves and beam profiles were evaluated for both open and wedged beams. Tolerance parameters chosen for gamma analysis are 3% and 3 mm dose and distance, respectively.Absolute dose was measured independently at points proposed in Appendix E of TECDOC-1583 to validate software results. Results: TPS calculated depth dose distributions agree with measured beam data under fixed precision values at all depths analyzed. Measured beam dose profiles match TPS calculated doses with high accuracy in both open and wedged beams. Depth and profile dose distributions fitting analysis show gamma values < 1. Relative errors at points proposed in Appendix E of TECDOC-1583 meet therein recommended tolerances.Independent absolute dose measurements at points proposed in Appendix E of TECDOC-1583 confirm software results. Conclusion: Automatic validation of megavoltage beams modeled for their use in the clinic was accomplished. The software tool developed proved efficient, giving users a convenient and reliable environment to decide whether to accept or not a beam model for clinical use. Validation time before beam-on for clinical use was reduced to a few hours.

60 APPLIED LIFE SCIENCES↗

A comprehensive study of relativistic gravity using PSR B1534+12

We present updated analyses of pulse profiles and their arrival times from PSR B1534+12, a 37.9 ms radio pulsar in orbit with another neutron star. A high-precision timing model is derived from 22 yr of timing data and accounts for all astrophysical processes that systematically affect pulse arrival times. Five 'post-Keplerian' parameters are measured that represent relativistic corrections to the standard Keplerian quantities of the pulsar's binary orbit. These relativistic parameters are then used to test general relativity by comparing the measurements with their predicted values. We conclude that relativity theory is confirmed to within 0.17% of its predictions. Furthermore, we derive the following astrophysical results from our timing analysis: a distance of d {sub GR} = 1.051 ± 0.005 kpc to the pulsar-binary system, by relating the 'excess' orbital decay to Galactic parameters; evidence for pulse 'jitter' in PSR B1534+12 due to short-term magnetospheric activity; and evolution in pulse-dispersion properties. As a secondary study, we also present several analyses on pulse-structure evolution and its connection to relativistic precession of the pulsar's spin axis. The precession-rate measurement yields a value of Ω{sub 1}{sup spin}=0.59{sub −0.08}{sup +0.12}° yr{sup –1} (68% confidence) that is consistent with expectations and represents an additional test of relativistic gravity.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a new generation of optical slope measuring profiler

A collaboration, including all DOE synchrotron labs, industrial vendors of x-ray optics, and with active participation of the HBZ-BESSY-II optics group has been established to work together on a new slope measuring profiler -- the optical slope measuring system (OSMS). The slope measurement accuracy of the instrument is expected to be<50 nrad for the current and future metrology of x-ray optics for the next generation of light sources. The goals were to solidify a design that meets the needs of mirror specifications and also be affordable; and to create a common specification for fabrication of a multi-functional translation/scanning (MFTS) system for the OSMS. This was accomplished by two collaborative meetings at the ALS (March 26, 2010) and at the APS (May 6, 2010).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elevation angle alignment of quasi optical receiver mirrors of collective Thomson scattering diagnostic by sawtooth measurements

Localized measurements of the fast ion velocity distribution function and the plasma composition measurements are of significant interest for the fusion community. Collective Thomson scattering (CTS) diagnostics allow such measurements with spatial and temporal resolution. Localized measurements require a good alignment of the optical path in the transmission line. Monitoring the alignment during the experiment greatly benefits the confidence in the CTS measurements. An in situ technique for the assessment of the elevation angle alignment of the receiver is developed. Using the CTS diagnostic on TEXTOR without a source of probing radiation in discharges with sawtooth oscillations, an elevation angle misalignment of 0.9 Degree-Sign was found with an accuracy of 0.25 Degree-Sign .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical Investigation of Hydrogen Adsorption and Dissociation on Iron and Iron Carbide Surfaces Using the ReaxFF Reactive Force Field Method

We have developed a ReaxFF reactive force field to describe hydrogen adsorption and dissociation on iron and iron carbide surfaces relevant for simulation of Fischer–Tropsch (FT) synthesis on iron catalysts. This force field enables large system (>>1000 atoms) simulations of hydrogen related reactions with iron. The ReaxFF force field parameters are trained against a substantial amount of structural and energetic data including the equations of state and heats of formation of iron and iron carbide related materials, as well as hydrogen interaction with iron surfaces and different phases of bulk iron. We have validated the accuracy and applicability of ReaxFF force field by carrying out molecular dynamics simulations of hydrogen adsorption, dissociation and recombination on iron and iron carbide surfaces. The barriers and reaction energies for molecular dissociation on these two types of surfaces have been compared and the effect of subsurface carbon on hydrogen interaction with iron surface is evaluated. We found that existence of carbon atoms at subsurface iron sites tends to increase the hydrogen dissociation energy barrier on the surface, and also makes the corresponding hydrogen dissociative state relatively more stable compared to that on bare iron. These properties of iron carbide will affect the dissociation rate of H{sub 2} and will retain more surface hydride species, thus influencing the dynamics of the FT synthesis process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved measurement accuracy of the quadrant detector through improvement of linearity index

This paper presents a set of formulae for estimating the beam position projected on a quadrant detector (QD). Our new formulae are designed through a systematic procedure to improve the measurement accuracy of the QD. It can be applied to different beam profiles. It is shown in simulations that our new formulae have achieved a much better measurement accuracy. It is also shown through experimental study that our approach is robust and able to achieve very good performance in practice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopy of the methane {nu}{sub 3} band with an accurate midinfrared coherent dual-comb spectrometer

We demonstrate a high-accuracy dual-comb spectrometer centered at 3.4 {mu}m. The amplitude and phase spectra of the P, Q, and partial R branches of the methane {nu}{sub 3} band are measured at 25 to 100 MHz point spacing with resolution under 10 kHz and a signal-to-noise ratio of up to 3500. A fit of the absorbance and phase spectra yields the center frequency of 132 rovibrational lines. The systematic uncertainty is estimated to be 300 kHz, which is 10{sup -3} of the Doppler width and a 10-fold improvement over Fourier transform spectroscopy. These data quantify the accuracy and resolution achievable with direct comb spectroscopy in the midinfrared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preconditioned least‐squares Petrov–Galerkin reduced order models

Abstract In this article, we introduce a methodology for improving the accuracy and efficiency of reduced order models (ROMs) constructed using the least‐squares Petrov–Galerkin (LSPG) projection method through the introduction of preconditioning. Unlike prior related work, which focuses on preconditioning the linear systems arising within the ROM numerical solution procedure to improve linear solver performance, our approach leverages a preconditioning matrix directly within the minimization problem underlying the LSPG formulation. Applying preconditioning in this way has the potential to improve ROM accuracy for several reasons. First, preconditioning the LSPG formulation changes the norm defining the residual minimization, which can improve the residual‐based stability constant bounding the ROM solution's error. The incorporation of a preconditioner into the LSPG formulation can have the additional effect of scaling the components of the residual being minimized to make them roughly of the same magnitude, which can be beneficial when applying the LSPG method to problems with disparate scales (e.g., dimensional equations, multi‐physics problems). Importantly, we demonstrate that an “ideal preconditioned” LSPG ROM (a ROM in which the preconditioner is the inverse of the Jacobian of its corresponding full order model) emulates projection of the full order model solution increment onto the reduced basis. This quantity defines a lower bound on the error of a ROM solution for a given reduced basis. By designing preconditioners that approximate the Jacobian inverse—as is common in designing preconditioners for solving linear systems—it is possible to obtain a ROM whose error approaches this lower bound. The proposed approach is evaluated on several mechanical and thermo‐mechanical problems implemented within the Albany HPC code and run in the predictive regime, with prediction across material parameter space. We demonstrate numerically that the introduction of simple Jacobi, Gauss‐Seidel, and ILU preconditioners into the proper orthogonal decomposition/LSPG formulation reduces significantly the ROM solution error, the reduced Jacobian condition number, the number of nonlinear iterations required to reach convergence, and the wall time (thereby improving efficiency). Moreover, our numerical results reveal that the introduction of preconditioning can deliver a robust and accurate solution for test cases in which the unpreconditioned LSPG method fails to converge.

Lindsay, Payton↗

Validation of the EDGES Low-band Antenna Beam Model

The response of the antenna is a source of uncertainty in measurements with the Experiment to Detect the Global Epoch of Reionization Signature (EDGES). We aim to validate the electromagnetic beam model of the low-band (50–100 MHz) dipole antenna with comparisons between models and against data. We find that simulations of a simplified model of the antenna over an infinite perfectly conducting ground plane are, with one exception, robust to changes in the numerical electromagnetic solver code or algorithm. For simulations of the antenna with the actual finite ground plane and realistic soil properties, we find that two out of three numerical solvers agree well. Applying our analysis pipeline to a simulated drift-scan observation from an early EDGES low-band instrument that had a 10 m × 10 m ground plane, we find residual levels after fitting and removing a five-term foreground model from the simulated data binned in local sidereal time (LST) average about 250 mK with ±40 mK variation between numerical solvers. A similar analysis of the primary 30 m × 30 m sawtooth ground plane reduced the LST-averaged residuals to about 90 mK with ±10 mK between the two viable solvers. More broadly we show that larger ground planes generally perform better than smaller ground planes. Simulated data have a power that is within 4% of real observations, a limitation of net accuracy of the sky and beam models. We observe that residual spectral structures after foreground model fits match qualitatively between simulated data and observations, suggesting that the frequency dependence of the beam is reasonably represented by the models. We find that a soil conductivity of 0.02 S m{sup -1} and relative permittivity of 3.5 yield good agreement between simulated spectra and observations. This is consistent with the soil properties reported by Sutinjo et al. for the Murchison Radio-astronomy Observatory, where EDGES is located.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transferability and accuracy by combining dispersionless density functional and incremental post-Hartree-Fock theories: Noble gases adsorption on coronene/graphene/graphite surfaces

The accuracy and transferability of the electronic structure approach combining dispersionless density functional theory (DFT) [K. Pernal et al., Phys. Rev. Lett. 103, 263201 (2009)] with the method of increments [H. Stoll, J. Chem. Phys. 97, 8449 (1992)], are validated for the interaction between the noble-gas Ne, Ar, Kr, and Xe atoms and coronene/graphene/graphite surfaces. This approach uses the method of increments for surface cluster models to extract intermonomer dispersion-like (2- and 3-body) correlation terms at coupled cluster singles and doubles and perturbative triples level, while periodic dispersionless density functionals calculations are performed to estimate the sum of Hartree-Fock and intramonomer correlation contributions. Dispersion energy contributions are also obtained using DFT-based symmetry-adapted perturbation theory [SAPT(DFT)]. An analysis of the structure of the X/surface (X = Ne, Ar, Kr, and Xe) interaction energies shows the excellent transferability properties of the leading intermonomer correlation contributions across the sequence of noble-gas atoms, which are also discussed using the Drude oscillator model. We further compare these results with van der Waals-(vdW)-corrected DFT-based approaches. As a test of accuracy, the energies of the low-lying nuclear bound states supported by the laterally averaged X/graphite potentials (X = {sup 3}He, {sup 4}He, Ne, Ar, Kr, and Xe) are calculated and compared with the best estimations from experimental measurements and an atom-bond potential model using the ab initio-assisted fine-tuning of semiempirical parameters. The bound-state energies determined differ by less than 6–7 meV (6%) from the atom-bond potential model. The crucial importance of including incremental 3-body dispersion-type terms is clearly demonstrated, showing that the SAPT(DFT) approach effectively account for these terms. With the deviations from the best experimental-based estimations smaller than 2.3 meV (1.9%), the accuracy of the combined DFT and post-HF incremental scheme is established for all the noble-gas atoms. With relative deviations smaller than 4% and 11%, good agreement is also achieved by applying the vdW-corrected DFT treatments PBE-D3 and vdW-DF2 for noble-gas atoms heavier than neon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accurate noncontact calibration of colloidal probe sensitivities in atomic force microscopy

The absolute force sensitivities of colloidal probes comprised of atomic force microscope, or AFM, cantilevers with microspheres attached to their distal ends are measured. The force sensitivities are calibrated through reference to accurate electrostatic forces, the realizations of which are described in detail. Furthermore, the absolute accuracy of a common AFM force calibration scheme, known as the thermal noise method, is evaluated. It is demonstrated that the thermal noise method can be applied with great success to colloidal probe calibration in air and in liquid to yield force measurements with relative standard uncertainties below 5%. Techniques to combine the electrostatics-based determination of the AFM force sensitivity with measurements of the colloidal probe's thermal noise spectrum to compute noncontact estimates of the displacement sensitivity and spring constant are also developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Limits on preserving quantum coherence using multipulse control

We explore the physical limits of pulsed dynamical decoupling methods for decoherence control as determined by finite timing resources. By focusing on a decohering qubit controlled by arbitrary sequences of {pi} pulses, we establish a nonperturbative quantitative upper bound to the achievable coherence for specified maximum pulsing rate and noise spectral bandwidth. We introduce numerically optimized control ''bandwidth-adapted'' sequences that saturate the performance bound and show how they outperform existing sequences in a realistic excitonic-qubit system where timing constraints are significant. As a by-product, our analysis reinforces the impossibility of fault-tolerance accuracy thresholds for generic open quantum systems under purely reversible error control.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water-equivalent path length calibration of a prototype proton CT scanner

Purpose: The authors present a calibration method for a prototype proton computed tomography (pCT) scanner. The accuracy of these measurements depends upon careful calibration of the energy detector used to measure the residual energy of the protons that passed through the object. Methods: A prototype pCT scanner with a cesium iodide (CsI(Tl)) crystal calorimeter was calibrated by measuring the calorimeter response for protons of 200 and 100 MeV initial energies undergoing degradation in polystyrene plates of known thickness and relative stopping power (RSP) with respect to water. Calibration curves for the two proton energies were obtained by fitting a second-degree polynomial to the water-equivalent path length versus calorimeter response data. Using the 100 MeV calibration curve, the RSP values for a variety of tissue-equivalent materials were measured and compared to values obtained from a standard depth-dose range shift measurement using a water-tank. A cylindrical water phantom was scanned with 200 MeV protons and its RSP distribution was reconstructed using the 200 MeV calibration. Results: It is shown that this calibration method produces measured RSP values of various tissue-equivalent materials that agree to within 0.5% of values obtained using an established water-tank method. The mean RSP value of the water phantom reconstruction was found to be 0.995 {+-} 0.006. Conclusions: The method presented provides a simple and reliable procedure for calibration of a pCT scanner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-72: Experimental Determination of the Positionuncertainties for ROOS Ionization Chambers in Clinical Electron Beams

Purpose: National and international dosimetry protocols assume a position accuracy for ionization chambers of less than 0.2mm. To follow this precept the manufacturer PTW-Freiburg introduced a positioning assistance system (TRUFIX) for their particular ion chambers. Aim of this study is an experimental investigation of the positioning uncertainties for ROOS-type ionization chambers. Methods: For all measurements a linear accelerator Elekta Synergie was used. The experiments were performed in a water-phantom. To collimate the electron beam a 10×10cm{sup 2} applicator was installed. All measured depth dose curves were normalized to their maximum. In all cases the TRUFIX system was applied for chamber positioning. For the first measurement series, to determine the positioning reproducibility of a ROOS chamber, one person placed the chamber three times in a 6 MeV electron beam. The mean value of this three measurements was the reference for further six random persons who repeated this procedure. The results were compared for different depths (R{sub 50}, z{sub ref} and R{sub p}). To investigate the impact of different individual chambers of the same type 10 different ROOS chambers were placed by the same person in a 6, 12 and 18MeV electron beam and the measured reference depths z{sub ref} were compared. Results: The absolute positioning reproducibility is less than 0.1mm for the same person. The positioning uncertainties are increasing up to +/−0.3mm if different persons perform the chamber’s positioning within the water phantom. The comparison of the 10 different ROOS chambers resulted in reference depths z{sub ref} with deviations in the range of +/−0.45mm for all energies. Conclusion: The position accuracy of 0.2mm can be fulfilled with the TRUFIX system. The comparison of the 10 different ROOS ionization chambers showed noticeable deviations in the determined reference depth. The impact of a positioning uncertainty of about 0.3–0.4mm on the total perturbation correction will be considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved time-frequency analysis of ASDEX Upgrade reflectometry data using the reassigned spectrogram technique

The spectrogram is one of the best-known time-frequency distributions suitable to analyze signals whose energy varies both in time and frequency. In reflectometry, it has been used to obtain the frequency content of FM-CW signals for density profile inversion and also to study plasma density fluctuations from swept and fixed frequency data. Being implemented via the short-time Fourier transform, the spectrogram is limited in resolution, and for that reason several methods have been developed to overcome this problem. Among those, we focus on the reassigned spectrogram technique that is both easily automated and computationally efficient requiring only the calculation of two additional spectrograms. In each time-frequency window, the technique reallocates the spectrogram coordinates to the region that most contributes to the signal energy. The application to ASDEX Upgrade reflectometry data results in better energy concentration and improved localization of the spectral content of the reflected signals. When combined with the automatic (data driven) window length spectrogram, this technique provides improved profile accuracy, in particular, in regions where frequency content varies most rapidly such as the edge pedestal shoulder.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vertically polarizing undulator with the dynamic compensation of magnetic forces for the next generation of light sources

A short prototype (847-mm-long) of an Insertion Device (ID) with the dynamic compensation of ID magnetic forces has been designed, built, and tested at the Advanced Photon Source (APS) of the Argonne National Laboratory. The ID magnetic forces were compensated by the set of conical springs placed along the ID strongback. Well-controlled exponential characteristics of conical springs permitted a very close fit to the ID magnetic forces. Several effects related to the imperfections of actual springs, their mounting and tuning, and how these factors affect the prototype performance has been studied. Finally, series of tests to determine the accuracy and reproducibility of the ID magnetic gap settings have been carried out. Based on the magnetic measurements of the ID B{sub eff}, it has been demonstrated that the magnetic gaps within an operating range were controlled accurately and reproducibly within ±1 μm. Successful tests of this ID prototype led to the design of a 3-m long device based on the same concept. The 3-m long prototype is currently under construction. It represents R and D efforts by the APS toward APS Upgrade Project goals as well as the future generation of IDs for the Linac Coherent Light Source (LCLS)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗