Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Measurement of Local Heat Transfer Coefficients for Flow of Hydrogen and Helium in a Smooth Tube at High Surface to Fluid Bulk Temperature Ratios

Local values of heat transfer coefficients have been measured experimentally for helium and hydrogen gas flowing through an electrically heated inconel tube. The experiment was conducted pri­marily to determine the effect on the heat transfer coefficient of a large density change, radially, in the heat transfer fluid. This large density change was accomplished with relatively high surface temperatures as compared to fluid bulk temperatures or more commonly referred to as high surface to fluid bulk tempera­ture ratio. The large temperature ratio was achieved by precooling the gas with liquid nitrogen. Data were measured for local values of surface to fluid bulk temperature ratios up to 4.5, Reynolds numbers in the turbulent flow region, surface temperatures up to 2300° R, heat flux up to 1,600,000 Btu/(hr)(sq ft) and length to diameter ratio of 250. A comparison of this data with the conventional heat transfer· correlation equation (Dittus-Boelter eq.) is shown on a curve of Nusselt number divided by Prandtl number versus the Reynolds number. The gas properties were evaluated at the film temperature and the Reynolds number was modified by evaluating the velocity term at the fluid bulk temperature and the density at the film temperature.

Weiland, Walter F.↗

Earned Value Management (EVM) Implementation Handbook

The purpose of this handbook is to provide Earned Value Management (EVM) guidance for the effective application, implementation, and utilization of EVM on NASA programs, projects, major contracts and subcontracts in a consolidated reference document. EVM is a project management process that effectively integrates a project?s scope of work with schedule and cost elements for optimum project planning and control. The goal is to achieve timely and accurate quantification of progress that will facilitate management by exception and enable early visibility into the nature and the magnitude of technical problems as well as the intended course and success of corrective actions.

Planning Package↗

Two-stage ignition behavior and octane sensitivity of toluene reference fuels as gasoline surrogate

Current approaches to improve the efficiency of Spark-Ignition (SI) gasoline engines have been focusing on turbocharging, increasing the compression ratio, and pursuing advanced low-temperature combustion concepts. In order to maximize these strategies, it is important to optimize the knock resistance of the fuel, and therefore knowledge of the sensitivity of the ignition process under a wide range of engine operating conditions is required. Octane sensitivity (OS), which is defined as the difference between Research Octane Number (RON) and Motored Octane Number (MON), has been introduced to represent how fuel's ignition reactivity changes relative to the primary reference fuels (n-heptane/iso-octane) within RON/MON conditions. Previous works have indicated that OS is intimately related to low temperature reactivity of the fuel, which can be revealed as two-stage heat release characteristics during an ignition event. Prompted by these findings, in this paper, we investigate the relationship between two-stage ignition behavior and OS, using chemical kinetic simulations of 24 Toluene Reference Fuels (TRFs)/ethanol blends. TRFs are ternary mixtures of n-heptane/iso-octane/toluene, which is capable of capturing aromatic content and positive values of OS of real gasoline fuels. Simulation results show that fuels with weak or no two-stage ignition behavior tend to have high OS, due to their lack of Negative Temperature Coefficient (NTC) effect and high sensitivity in ignition delay time. Leveraging such observations, we develop a correlation between two-stage behavior and OS as an OS prediction method. Two metrics that represent the strength of the two-stage ignition behavior are proposed and used as OS predictors, which are Low Temperature Heat Release percentage (LTHR%) and Heat Release Rate at the end of first stage (HRR inf ) calculated from a simple kinetic simulation. Regression analysis shows a clear trend between decreases in the proposed two-stage behavior metrics and increases in the value of OS of the fuel. We also test the new metric (LTHR%) using simulation results of 0-D reactors with imposed pressure time histories obtained from engine experiments, as well as using different TRF kinetic mechanisms. Here, the results demonstrate the effectiveness of the metric as a representation of the two-stage ignition behavior in practical combustion systems, highlighting the importance of the proposed relationship, and its potential as a simple and effective OS predictor.

30 DIRECT ENERGY CONVERSION↗

IRDFF-II: A New Neutron Metrology Library

High quality nuclear data is the most fundamental underpinning for all neutron metrology applications. This paper describes the release of version II of the International Reactor Dosimetry and Fusion File (IRDFF-II) that contains a consistent set of nuclear data for fission and fusion neutron metrology applications up to 60 MeV neutron energy. The library is intended to support: a) applications in research reactors; b) safety and regulatory applications in the nuclear power generation in commercial fission reactors; and c) material damage studies in support of the research and development of advanced fusion concepts. The paper describes the contents of the library, documents the thorough verification process used in its preparation, and provides an extensive set of validation data gathered from a wide range of neutron benchmark fields. The new IRDFF-II library includes 119 metrology reactions, four cover material reactions to support self-shielding corrections, five metrology metrics used by the dosimetry community, and cumulative fission products yields for seven fission products in three different neutron energy regions. In support of characterizing the measurement of the residual nuclei from the dosimetry reactions and the fission product decay modes, the present document lists the recommended decay data, particle emission energies and probabilities for 68 activation products. It also includes neutron spectral characterization data for 29 neutron benchmark fields for the validation of the library contents. Additional six reference fields were assessed (four from plutonium critical assemblies, two measured fields for thermal-neutron induced fission on 233U and 239Pu targets) but not used for validation due to systematic discrepancies in C/E reaction rate values or lack of reaction-rate experimental data. Another ten analytical functions are included that can be useful for calculating average cross sections, average energy, thermal spectrum average cross sections and resonance integrals. The IRDFF-II library and comprehensive documentation is available online at www-nds.iaea.org/IRDFF/. Evaluated cross sections can be compared with experimental data and other evaluations at www-nds.iaea.org/exfor/endf.htm. The new library is expected to become the international reference in neutron metrology for multiple applications.

IAEA IRDFF↗

Transgenic Sugarcane–Oilcane: An Alternative Feedstock for the Production of Drop-in Fuel and Value-Added Bioproducts

The utilization of plants and other agricultural produce can partly offset petroleum dependency for energy requirements and can potentially provide sustainable solutions to global environmental problems. To this end, synthetic biology has shown great potential in developing transgenic bioenergy grasses such as sugarcane, sorghum, miscanthus, and energy cane that hyperaccumulate energy-rich lipid molecules in their vegetative tissues, such as leaves, stems, and roots. These perennial high-biomass transgenic C4 grasses are not targeted to grow on prime agricultural land and can be dedicatedly used to produce biofuels and other value-added bioproducts. Recently, sugarcane has been metabolically engineered to sequestrate carbon from juice towards biosynthesis of lipid molecules in the vegetative tissues. Transgenic sugarcane is referred to as “oilcane.” Transgenic sugarcane–oilcane has improved energy density due to an elevated lipid content in the vegetative tissues. Transgenic bioenergy crops cater to both cellulosic sugars and vegetative lipids, hence resulting in higher biofuel yield (biodiesel/renewable diesel and bioethanol) per unit area of cultivable land. In this book chapter, the genetic engineering of sugarcane and its bioprocessing are discussed to illustrate its development and use as an alternative feedstock for the production of biofuels (bio-jet fuel, biodiesel, and bioethanol) and value-added bioproducts.

Maitra, Shraddha↗

Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Background: To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI). Methods and Results: This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. Conclusions: CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Group additivity values for the heat of formation of C 2 –C 8 alkanes, alkyl hydroperoxides, and their radicals

A set of 58 group additivity values (GAV) for the calculation of the heat of formation is derived from an extensive and accurate database of 192 ab initio heats of formation. The ab initio values are from companion calculations at the CCSD(T)–F12/cc-pVTZ-F12//B2PLYPD3/cc-pVTZ level of theory employing second order connectivity based hierarchy reference reactions with ANL energies for the reference species. This database of 192 species consists of alkanes (RH), alkyl radicals ($\dot{\text {R}}$), alkyl hydroperoxides (RO 2 H), alkyl-peroxy (R$\dot{\text {O}}$ 2 ) radicals, and hydroperoxy-alkyl ($\dot{\text {Q}}$OOH) radicals of all of the isomers of C 2 –C 5 alkane fuels and a select set of C 6 –C 8 isomers. The GAV and ab initio based enthalpies for this dataset show excellent agreement, with an estimated 2σ uncertainty of 0.9 kcal mol –1 . Among the 58 GAV terms, 40 are refinements of previously reported terms, while 18 are newly developed. These new GAV terms are mainly non-next-nearest neighbor interactions (NNI) and β-corrections. The inclusion of these new groups significantly improves the accuracy of the GAV estimates of the heats of formation. Finally, the updated GAVs can be used with increased confidence to estimate the heats of formation of combustion relevant hydrocarbons and oxygenated hydrocarbons and their corresponding radicals, which are important in predicting low-temperature chemistry and are critical in the development of accurate chemical kinetic models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multibiomarker assessment of three Brazilian estuaries using oysters as bioindicators

Oysters have been largely employed as bioindicators of environmental quality in biomonitoring studies. Crassostrea rhizophorae was selected to evaluate the health status of three estuarine areas impacted by anthropogenic activities along the Brazilian coast, in three estuarine complexes, ranging in latitude from 7 to 25 deg. S. In each estuary three sites were sampled in Winter and in Summer: a site considered as reference, and two sites next to contamination sources. Condition index was similar at all sites and estuaries, with the highest values found for Itamaraca oysters in Summer. Necrosis, hyperplasia, mucocyte hypertrophy and fusion of ordinary filaments were the main histopathological lesions observed. Muscle cholinesterase activity was overall similar, but with a strong seasonal effect. Inhibition or activation of branchial total ATPase and Na,K-ATPase activities at the contaminated sites was observed. The health status of these estuarine areas is quite similar, and the combined use of biomarkers is recommended.

60 APPLIED LIFE SCIENCES↗

Thickness-based adaptive mesh refinement methods for multi-phase flow simulations with thin regions

In numerical simulations of multi-scale, multi-phase flows, grid refinement is required to resolve regions with small scales. A notable example is liquid-jet atomization and subsequent droplet dynamics. It is essential to characterize the detailed flow physics with variable length scales with high fidelity, in order to elucidate the underlying mechanisms. In this paper, two thickness-based mesh refinement schemes are developed based on distance- and topology-oriented criteria for thin regions with confining wall/plane of symmetry and in any situation, respectively. Both techniques are implemented in a general framework with a volume-of-fluid formulation and an adaptive-mesh-refinement capability. The distance-oriented technique compares against a critical value, the ratio of an interfacial cell size to the distance between the mass center of the cell and a reference plane. The topology-oriented technique is developed from digital topology theories to handle more general conditions. The requirement for interfacial mesh refinement can be detected swiftly, without the need of thickness information, equation solving, variable averaging or mesh repairing. The mesh refinement level increases smoothly on demand in thin regions. The schemes have been verified and validated against several benchmark cases to demonstrate their effectiveness and robustness. These include the dynamics of colliding droplets, droplet motions in a microchannel, and atomization of liquid impinging jets. Overall, the thickness-based refinement technique provides highly adaptive meshes for problems with thin regions in an efficient and fully automatic manner.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Helical Tomotherapy of Nasopharyngeal Carcinoma-Any Advantages Over Conventional Intensity-Modulated Radiotherapy?

Helical tomotherapy uses different planning algorithm and dose delivery method from the linear accelerator (linac)-based intensity-modulated radiotherapy (IMRT). This study compared the dosimetric outcomes between the tomotherapy plans and conventional linac-based IMRT plans in the treatment of nasopharyngeal carcinoma (NPC). Fifteen stage II-III cancer (American Joint Committee on Cancer) NPC patients treated by tomotherapy were conveniently recruited. Apart from the tomotherapy plans, a 7-field 6-MV photon conventional IMRT plan was computed for each patient with the same CT dataset and reference from the dose constraints and target dose prescriptions of the tomotherapy plans using the XiO treatment planning system. Average values of the dose parameters including the conformity index (CI), homogeneity index (HI), maximum and minimum doses of the target volumes, and the maximum and mean doses of the organs at risk (OAR) were compared between the two treatment methods. Better dose coverage of the planning target volume (PTV) was demonstrated in the tomotherapy plans, in which the differences in the maximum and mean doses reached statistical significance (p < 0.05). Besides, the CI of the tomotherapy plans were significantly higher than the conventional linac-based plans for the nasopharynx PTV (NP-PTV) and neck lymphatics PTV (LN-PTV) (p = 0.017 and 0.010, respectively). The HI was significantly smaller in both NP-PTV and LN-PTV (p = 0.024 and < 0.001, respectively). Among the OAR, the brain stem and spinal cord doses in the tomotherapy plans were lower than that of the conventional IMRT plans. However, the doses to the other OAR did not show significant dosimetric differences. In the treatment of nasopharyngeal carcinoma, tomotherapy plans were superior to the 7-field conventional IMRT plans in PTV dose conformity and homogeneity and the sparing of the brain stem and spinal cord. However, no significant advantages were observed for the rest of the OAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculating the momentum enhancement factor for asteroid deflection studies

The possibility of kinetic-impact deflection of threatening near-Earth asteroids will be tested for the first time in the proposed AIDA (Asteroid Impact Deflection Assessment) mission, involving NASAs DART (Double Asteroid Redirection Test). The impact of the DART spacecraft onto the secondary of the binary asteroid 65803 Didymos at a speed of 5 to 7 km/s is expected to alter the mutual orbit by an observable amount. Furthermore, the velocity transferred to the secondary depends largely on the momentum enhancement factor, typically referred to as beta. Here, we use two hydrocodes developed at Los Alamos, RAGE and PAGOSA, to calculate an approximate value for beta in laboratory-scale benchmark experiments. Convergence studies comparing the two codes show the importance of mesh size in estimating this crucial parameter.

79 ASTRONOMY AND ASTROPHYSICS↗

Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry

RATIONALE: The field of highly accurate and precise isotope ratio (IR) analysis has been dominated by inductively coupled plasma and thermal ionization mass spectrometers. While these instruments are considered the gold standard for IR analysis, the International Atomic Energy Agency desires a field deployable instrument capable of accurately and precisely measuring U isotope ratios. METHODS: The proposed system interfaces the liquid sampling – atmospheric pressure glow discharge (LS-APGD) ion source with a high resolution Exactive Orbitrap mass spectrometer. With this experimental setup certified U isotope standards and unknown samples were analyzed. The accuracy and precision of the system were then determined. RESULTS: The LS-APGD /Exactive instrument measures a certified reference material of natural U (235U/238U = 0.007258) as 0.007041 with a relative standard deviation of 0.158% meeting the International Target Values for Uncertainty for the destructive analysis of U. Additionally, when three unknowns measured and compared to the results from an ICP multi collector instrument, there is no statistical difference between the two instruments. CONCLUSIONS: The LS-APGD / Orbitrap system, while still in the preliminary stages of development, offers highly accurate and precise IR analysis that suggest a paradigm shift in the world of IR analysis. Furthermore, the portability of the LS-APGD as an elemental ion source combined with the low overhead and small size of the Orbitrap suggest that the instrumentation is capable of being field deployable. With liquid sampling glow discharge-Orbitrap MS, isotope ratio and precision performance improves with rejection of concomitant ion species.

atmospheric pressure sampling↗

High-throughput bend-strengths of ultra-small polysilicon MEMS components

The strength distribution of polysilicon bend specimens, approximately 10 μm in size, is measured using a high-throughput microelectromechanical system fabrication and testing method. The distribution is predicted from reference tests on tensile specimens and finite element analysis of the bend specimen geometry incorporated into a stochastic extreme-value strength framework. Agreement between experiment and prediction suggests that the ultra-small specimens may be at the limit of extreme-value scaling and contain only one strength-controlling flaw/specimen.

Cook, Robert F. (ORCID:0000000304228881)↗

A small-volume, high-throughput approach for surface tension and viscosity measurements of liquid fuels

An ongoing effort looking at bioblendstocks to function as drop-in replacements or blending components for gasoline has identified a large number of candidate fuels. This work documents an approach for rapid screening of candidate fuels using relatively small sample sizes ($\mathcal{O}(\mu\,{\rm l})$) that targets two key physical properties of liquid fuels—surface tension and viscosity. The approach utilizes shape oscillation dynamics of single droplets generated by a piezo-electric device and their decay over time. Strobed imaging of the oscillation process is used along with image processing, edge detection, and data analysis to capture the decay of the oscillation over time. The time constant of the decay process along with oscillation frequency are then used to estimate viscosity and surface tension using a theory for small amplitude droplet oscillations. Measurements are obtained for primary reference fuels (isooctane and n-heptane) as well as candidate fuels from four bio-derived functional groups of interest. Measurement results for surface tension and viscosity are correlated with literature data as well as measurements from standard reference instruments. The measurement results show that the droplet oscillation based approach is capable of reproducing surface tension and viscosity values for the tested fuels within deviations of 7% and 13% respectively from literature data. Results are obtained using an average of 5 µl per fuel within about 20 s, thus demonstrating a small-volume, high-throughput approach that can be used for screening of candidate bioblendstock fuels.

09 BIOMASS FUELS↗

Emulation of seismic-phase traveltimes with machine learning

SUMMARY We present a machine learning (ML) method for emulating seismic-phase traveltimes that are computed using a global-scale 3-D earth model and physics-based ray tracing. Accurate traveltime predictions based on 3-D earth models are known to reduce the bias of event location estimates, increase our ability to assign phase labels to seismic detections and associate detections to events. However, practical use of 3-D models is challenged by slow computational speed and the unwieldiness of pre-computed lookup tables that are often large and have prescribed computational grids. In this work, we train a ML emulator using pre-computed traveltimes, resulting in a compact and computationally fast way to approximate traveltimes that are based on a 3-D earth model. Our model is trained using approximately 850 million P-wave traveltimes that are based on the global LLNL-G3D-JPS model, which was developed for more accurate event location. The training-set consists of traveltimes between 10 393 global seismic stations and randomly sampled event locations that provide a prescribed, distance-dependent geographic sample density for each station. Prediction accuracy is dependent on event-station distance and whether the station was included in the training set. For stations included in the training set the mean absolute deviation (MAD) of the difference between traveltimes computed using ray tracing through the 3-D model and the ML emulator for local, regional, and teleseismic distances are 0.090, 0.125 and 0.121 s, respectively. For tested station locations not included in the training set, MAD values for the three distance ranges increase to 0.173, 0.219 and 0.210 s, respectively. Empirical traveltime residuals for a global reference data are indistinguishable when ML emulation or the 3-D model is used to compute traveltimes. This result holds regardless of whether the recording station is used in ML training or not.

58 GEOSCIENCES↗

A global calibration model for a-Si EPIDs used for transit dosimetry

Electronic portal imaging devices (EPIDs) are not only applied for patient setup verification and detection of organ motion but are also increasingly used for dosimetric verification. The aim of our work is to obtain accurate dose distributions from a commercially available amorphous silicon (a-Si) EPID for transit dosimetry applications. For that purpose, a global calibration model was developed, which includes a correction procedure for ghosting effects, field size dependence and energy dependence of the a-Si EPID response. In addition, the long-term stability and additional buildup material for this type of EPID were determined. Differences in EPID response due to photon energy spectrum changes have been measured for different absorber thicknesses and field sizes, yielding off-axis spectrum correction factors based on transmission measurements. Dose measurements performed with an ionization chamber in a water tank were used as reference data, and the accuracy of the dosimetric calibration model was determined for a large range of treatment conditions. Gamma values using 3% as dose-difference criterion and 3 mm as distance-to-agreement criterion were used for evaluation. The field size dependence of the response could be corrected by a single kernel, fulfilling the gamma evaluation criteria in case of virtual wedges and intensity modulated radiation therapy fields. Differences in energy spectrum response amounted up to 30%-40%, but could be reduced to less than 3% using our correction model. For different treatment fields and (in)homogeneous phantoms, transit dose distributions satisfied in almost all situations the gamma criteria. We have shown that a-Si EPIDs can be accurately calibrated for transit dosimetry purposes.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-303-13: Initial Evaluation of Four Dimensional Diffusion- Weighted MRI (4D-DWI) and Its Effect On Apparent Diffusion Coefficient (ADC) Measurement

Purpose: Diffusion-weighted imaging(DWI) has been shown to have superior tumor-to-tissue contrast for cancer detection.This study aims at developing and evaluating a four dimensional DWI(4D-DWI) technique using retrospective sorting method for imaging respiratory motion for radiotherapy planning,and evaluate its effect on Apparent Diffusion Coefficient(ADC) measurement. Materials/Methods: Image acquisition was performed by repeatedly imaging a volume of interest using a multi-slice single-shot 2D-DWI sequence in the axial planes and cine MRI(served as reference) using FIESTA sequence.Each 2D-DWI image were acquired in xyz-diffusion-directions with a high b-value(b=500s/mm2).The respiratory motion was simultaneously recorded using bellows.Retrospective sorting was applied in each direction to reconstruct 4D-DWI.The technique was evaluated using a computer simulated 4D-digital human phantom(XCAT),a motion phantom and a healthy volunteer under an IRB-approved study.Motion trajectories of regions-of-interests(ROI) were extracted from 4D-DWI and compared with reference.The mean motion trajectory amplitude differences(D) between the two was calculated.To quantitatively analyze the motion artifacts,XCAT were controlled to simulate regular motion and the motions of 10 liver cancer patients.4D-DWI,free-breathing DWI(FB- DWI) were reconstructed.Tumor volume difference(VD) of each phase of 4D-DWI and FB-DWI from the input static tumor were calculated.Furthermore, ADC was measured for each phase of 4D-DWI and FB-DWI data,and mean tumor ADC values(M-ADC) were calculated.Mean M-ADC over all 4D-DWI phases was compared with M-ADC calculated from FB-DWI. Results: 4D-DWI of XCAT,the motion phantom and the healthy volunteer demonstrated the respiratory motion clearly.ROI D values were 1.9mm,1.7mm and 2.0mm,respectively.For motion artifacts analysis,XCAT 4D-DWI images show much less motion artifacts compare to FB-DWI.Mean VD for 4D-WDI and FB-DWI were 8.5±1.4% and 108±15%,respectively.Mean M-ADC for ADC measured from 4D-DWI and M-ADC measured from FB-DWI were (2.29±0.04)*0.001*mm2/s and (3.80±0.01)*0.001*mm2/s,respectively.ADC value ground-truth is 2.24*0.001*mm2/s from the input of the simulation. Conclusion: A respiratory correlated 4D-DWI technique has been initially evaluated in phantoms and a human subject.Comparing to free breathing DWI,4D-DWI can lead to more accurate measurement of ADC.

60 APPLIED LIFE SCIENCES↗

Towards a Validation Protocol for Satellite-Based Solar Resource Data

Satellite-based solar resource data are valued for their spatial extensiveness and long temporal record. Validation of such data, including accurate assessment of their uncertainties against reference datasets, is essential to give users confidence in and maximum benefit from the data. More broadly, the international Earth observation from space community estimates many geophysical parameters from satellite data, such as, to name just a few, precipitation, sea surface temperature and atmospheric aerosol amount. This community has made considerable progress in developing standard validation protocols for numerous satellite-derived parameters, protocols that recommend best practices to support benchmarking and comparison of satellite datasets. This paper explores some of the elements that could be included in a validation protocol for satellite solar resource data. The elements are illustrated using satellite and surface based solar data over Australia. Keywords: solar resource, satellite, validation, protocol

POWER TRANSMISSION AND DISTRIBUTION,SOLAR ENERGY↗