Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Weighing the Top Quark at CDF

The most recent measurements of the top quark mass using data collected by the Collider Detector at Fermilab are summarized. Using datasets with sensitivities as large as 3.2 fb{sup -1}, the top quark mass is determined to be m{sub t} = 172.6+-0.9(stat.)+-1.2(syst.) GeV/c{sup 2}. Prospects for improvement of this measurement and its implications are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The hunt for theta{sub 13} at the Daya Bay nuclear power plant

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is approx0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin{sup 2}2theta{sub 13}<0.01 with baseline uncertainties after 3 years of data taking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffraction news from CDF

We report updated results by the CDF II collaboration on diffractive W and Z production and preliminary results from a study of rapidity gaps between very forward jets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct production of a light CP-odd Higgs boson at the Tevatron and LHC

We show that the existing CDF L=630 pb{sup -1} Tevatron data on pp{yields}{mu}{sup +{mu}-}X places substantial limits on a light CP-odd Higgs boson a with m{sub a}<2m{sub B} produced via gg{yields}a, even for m{sub a}>2m{sub {tau}}for which BR(a{yields}{mu}{sup +{mu}-}) is relatively small. Extrapolation of this existing CDF analysis to L=10 fb{sup -1} suggests that Tevatron limits on the abb coupling strength in the region m{sub a}>8 GeV could be comparable to or better than limits from Upsilon decays in the m{sub a}<7 GeV region. We also give rough estimates of future prospects at the LHC, demonstrating that early running will substantially improve limits on a light a (or perhaps discover a signal). In particular, outside the Upsilon peak region, integrated luminosity of only 5 fb{sup -1}-20 fb{sup -1} (depending on m{sub a} and {radical}(s)) could reveal a peak in M{sub {mu}}{sup +}{sub {mu}}{sup -} and will certainly place important new limits on a light a. The importance of such limits in the context of next-to-minimal supersymmetric model Higgs discovery and (g-2){sub {mu}}are outlined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Breakdown of silicon particle detectors under proton irradiation

Silicon particle detectors made on Czochralski and float zone silicon materials were irradiated with 7 and 9 MeV protons at a temperature of 220 K. During the irradiations, the detectors were biased up to their operating voltage. Specific values for the fluence and flux of the irradiation were found to cause a sudden breakdown in the detectors. We studied the limits of the fluence and the flux in the breakdown as well as the behavior of the detector response function under high flux irradiations. The breakdown was shown to be an edge effect. Additionally, the buildup of an oxide charge is suggested to lead to an increased localized electric field, which in turn triggers a charge carrier multiplication. Furthermore, we studied the influences of the type of silicon material and the configuration of the detector guard rings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background limited mid-infrared photodetection with photovoltaic HgTe colloidal quantum dots

The photovoltaic response of thin films of HgTe colloidal quantum dots in the 3–5 μm range is observed. With no applied bias, internal quantum efficiency exceeding 40%, specific detectivity above 10{sup 10} Jones and microseconds response times are obtained at 140 K. The cooled devices detect the ambient thermal radiation. A detector with 5.25 μm cut-off achieves Background Limited Infrared Photodetection at 90 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative void fraction measurement with an eddy current flowmeter for generation IV Sodium cooled Fast Reactor

This study was carried out to understand the response of an eddy current type flowmeter in two phase liquid-metal flow. We use the technique of ellipse fit and correlate the fluctuations in the angle of inclination of this ellipse with the void fraction. The effects of physical parameters such as coil excitation frequency and flow velocity have been studied. The results show the possibility of using an eddy current flowmeter as a gas detector for large void fractions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

LHC forward physics

The goal of this report is to give a comprehensive overview of the rich field of forward physics, with a special attention to the topics that can be studied at the LHC. The report starts presenting a selection of the Monte Carlo simulation tools currently available, chapter 2, then enters the rich phenomenology of QCD at low, chapter 3, and high, chapter 4, momentum transfer, while the unique scattering conditions of central exclusive production are analyzed in chapter 5. The last two experimental topics, Cosmic Ray and Heavy Ion physics are presented in the chapter 6 and 7 respectively. Chapter 8 is dedicated to the BFKL dynamics, multiparton interactions, and saturation. The report ends with an overview of the forward detectors at LHC. Each chapter is correlated with a comprehensive bibliography, attempting to provide to the interested reader with a wide opportunity for further studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MicroBooNE, A Liquid Argon Time Projection Chamber (LArTPC) Neutrino Experiment

Liquid Argon time projection chamber (LArTPC) is a promising detector technology for future neutrino experiments. MicroBooNE is a upcoming LArTPC neutrino experiment which will be located on-axis of Booster Neutrino Beam (BNB) at Fermilab, USA. The R and D efforts on this detection method and related neutrino interaction measurements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THz Hot-Electron Photon Counter

We present a concept for the hot-electron transition-edge sensor capable of counting THz photons. The main need for such a sensor is a spectroscopy on future space telescopes where a background limited NEP approx. 10(exp -20) W/H(exp 1/2) is expected at around 1 THz. Under these conditions, the rate of photon arrival is very low and any currently imaginable detector with sufficient sensitivity will operate in the photon counting mode. The Hot-Electron Photon Counter based on a submicron-size Ti bridge has a very low heat capacity which provides a high enough energy resolution (approx.140 GHz) at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range would be approx. 30 dB. The sensor couples to radiation via a planar antenna and is read by a SQUID amplifier or by a 1-bit RSFQ ADC. A compact array of the antenna-coupled counters can be fabricated on a silicon wafer without membranes.

radiation detectors↗

Influence of Dust Loading on Atmospheric Ionizing Radiation on Mars

Measuring the radiation environment at the surface of Mars is the primary goal of the Radiation Assessment Detector on the NASA Mars Science Laboratory's Curiosity rover. One of the conditions that Curiosity will likely encounter is a dust storm. The objective of this paper is to compute the cosmic ray ionization in different conditions, including dust storms, as these various conditions are likely to be encountered by Curiosity at some point. In the present work, the Nowcast of Atmospheric Ionizing Radiation for Aviation Safety model, recently modified for Mars, was used along with the Badhwar & O'Neill 2010 galactic cosmic ray model. In addition to galactic cosmic rays, five different solar energetic particle event spectra were considered. For all input radiation environments, radiation dose throughout the atmosphere and at the surface was investigated as a function of atmospheric dust loading. It is demonstrated that for galactic cosmic rays, the ionization depends strongly on the atmosphere profile. Moreover, it is shown that solar energetic particle events strongly increase the ionization throughout the atmosphere, including ground level, and can account for the radio blackout conditions observed by the Mars Advanced Radar for Subsurface and Ionospheric Sounding instrument on the Mars Express spacecraft. These results demonstrate that the cosmic rays' influence on the Martian surface chemistry is strongly dependent on solar and atmospheric conditions that should be taken into account for future studies.

Norman, Ryan B.↗

SU-D-204-05: Quantitative Comparison of a High Resolution Micro-Angiographic Fluoroscopic (MAF) Detector with a Standard Flat Panel Detector (FPD) Using the New Metric of Generalized Measured Relative Object Detectability (GM-ROD)

Purpose: In endovascular image-guided neuro-interventions, visualization of fine detail is paramount. For example, the ability of the interventionist to visualize the stent struts depends heavily on the x-ray imaging detector performance. Methods: A study to examine the relative performance of the high resolution MAF-CMOS (pixel size 75µm, Nyquist frequency 6.6 cycles/mm) and a standard Flat Panel Detector (pixel size 194µm, Nyquist frequency 2.5 cycles/mm) detectors in imaging a neuro stent was done using the Generalized Measured Relative Object Detectability (GM-ROD) metric. Low quantum noise images of a deployed stent were obtained by averaging 95 frames obtained by both detectors without changing other exposure or geometric parameters. The square of the Fourier transform of each image is taken and divided by the generalized normalized noise power spectrum to give an effective measured task-specific signal-to-noise ratio. This expression is then integrated from 0 to each of the detector’s Nyquist frequencies, and the GM-ROD value is determined by taking a ratio of the integrals for the MAF-CMOS to that of the FPD. The lower bound of integration can be varied to emphasize high frequencies in the detector comparisons. Results: The MAF-CMOS detector exhibits vastly superior performance over the FPD when integrating over all frequencies, yielding a GM-ROD value of 63.1. The lower bound of integration was stepped up in increments of 0.5 cycles/mm for higher frequency comparisons. As the lower bound increased, the GM-ROD value was augmented, reflecting the superior performance of the MAF-CMOS in the high frequency regime. Conclusion: GM-ROD is a versatile metric that can provide quantitative detector and task dependent comparisons that can be used as a basis for detector selection. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

(Cd,Mn)Te Detectors for Characterization of X-Ray Emissions Generated During Laser-Driven Fusion Experiments

We present our measurements of (Cd,Mn)Te photoconductive detectors (PCDs), intending to characterize both the temporal and spectral dependence of X-ray emissions from laser-illuminated targets during inertial confinement fusion experiments. Our Cd_1-x Mn_x Te (x = 0.05) single crystals, doped with V,were grown using a vertical Bridgman method and annealed in Cd vapor for the highest resistivity of ~10^10 Omega cm. The 1-mm-long and 2.3-mm-long detectors were placed in the same housing as two1-mm-long diamond PCDs. Each device was preceded by a Be X-ray filter with 37%X-ray transmission at the 1 keV cutoff energy. Energy of the incident OMEGA laser pulses varied from 2.3 to 28 kJ. Using targets of empty plastic shells, we observed two X-ray emission events separated by 1.24 ns: the first event was caused by heating of the shell that created a hot corona, while the second event was an X-ray emission from the fully compressed target. Experiments with targets with steel cores enabled us to analyze the time-resolved relaxation dynamics of photo-excited carriers in the (Cd,Mn)Te crystals. According to our calculations, the (Cd,Mn)Te material can very effectively absorb X-rays with energies of up to above 100 keV and the (Cd,Mn)Te PCDs are likely to complement the diamond detectors currently used in laser-confinement fusion experiments.

CdMnTe↗

Some Recent Results with CLAS

The CLAS is a multipurpose, large acceptance magnetic spectrometer, instrumented with detector systems sensitive to charged and neutral particles. The experimental program at CLAS is aimed at furthering our understanding of hadronic and nuclear physics, through electron and photon scattering experiments, which cover a large range of topics, including meson and baryon spectroscopy, nucleon structure through elastic and deep inelastic scattering, nuclear transparency, nuclear correlations and nuclear structure. This talk will briefly describe the detector and the collaboration that uses it and will highlight some recent results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rare and Exotic Processes at CDF

We report recent results in CDF searches for rare and exotic processes. In a signature-based search, we examine the diphoton dataset for additional energetic objects. In a second signature-based search, we search for anomalous production of a photon, a b-tagged jet, and missing E{sub T}. Finally, we search for a Fermiophobic Higgs in the two-photon decay mode, and conclude this Higgs must have mass greater than 106 GeV/c{sup 2}, at 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

B{sub s}{sup 0} mixing and lifetime difference measurements at CDF

We review latest experimental results on the Bs mixing and lifetime difference measurements at CDF. We report on the latest beta{sub s} and DELTAGAMMA{sub s} results from B{sub s}->J/psiphi. We also discuss flavor specific DELTAGAMMA{sub s} measurements, including information from hadronic channels, B{sub s}->D{sub s}D{sub s} and B{sub s}->KK. We describe the new flavor tagging methodology and its calibration using the B{sub s} oscillations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-607: Performance Quantification of the Nine Detectors Used for Dosimetry Measurements in Advanced Radiation Therapy Treatments

Purpose: The purpose of this study was to quantify performance of the nine detectors used for dosimetry measurements in advanced radiation therapy treatments. Methods: The 6 MV beam was utilized for measurements of the field sizes with the lack of lateral charge particle equilibrium. For dose fidelity aspect, energy dependence was studied by measuring PDD and profiles at different depths. The volume effect and its influence on the measured dose profiles have been observed by measuring detector’s response function. Output factor measurements with respect to change in energy spectrum have been performed and collected data has been analyzed. The linearity of the measurements with the dose delivered has been evaluated and relevant comparisons were done. Results: The measured values of the output factors with respect to change in energy spectrum indicated presence of the energy dependence. The detectors with active volume size ≤ 0.3 mm3 maximum deviation from the mean is 5.6% for the field size 0.5 x 0.5 cm2 while detectors with active volume size > 0.3 mm3 have maximum deviation from the mean 7.1%. Linearity with dose at highest dose rate examined for diode detectors showed maximum deviation of 4% while ion chambers showed maximum deviation of 2.2%. Dose profiles showed energy dependence at shallow depths (surface to dmax) influenced by low energy particles with 12 % maximum deviation from the mean for 5 mm2 field size. In relation to Monte Carlo calculation, the detector’s response function σ values were between (0.42±0.25) mm and (1.2±0.25) mm. Conclusion: All the detectors are appropriate for the dosimetry measurements in advanced radiation therapy treatments. The choice of the detectors has to be determined by the application and the scope of the measurements in respect to energy dependence and ability to accurately resolve dose profiles as well as to it’s intrinsic characteristics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗