Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

In‐situ Analysis of Paste Properties in Resonant Acoustic Mixers for Quality Monitoring

Formulation control is key to achieving consistent target properties of energetic materials, as feedstock variations and slight deviations in the ratios of different ingredients can have major effects on final product properties, particularly in dense pastes with high particle loading >65 vol.%. In large‐scale operations, it is imperative to either correct or remove batches of material that perform outside baseline property specifications as early as possible to avoid unnecessary processing of suboptimal material. Quality monitoring is the practice of measuring material properties during processing using process analytical technologies as opposed to only testing the properties of the final product; it is a key principle in the quality‐by‐design frameworks used for designing formulations and manufacturing processes. Herein, a process analytical technology method for correlating material properties of dense pastes directly after mixing in a Resonant Acoustic Mixer to motor data is developed and used to detect differences in the particle content of dense paste formulations. This method was also capable of detecting variations in powder feedstock properties, such as particle packing efficiency, and is sensitive enough to detect changes of 2 wt.% in the total solids content of the formulation. The techniques presented herein show excellent promise for use as a process analytical technology capable of quantifying formulation effects on material movement modes during resonant acoustic mixing.

Materials science↗

Pretreatment Quality of Life Predicts for Locoregional Control in Head and Neck Cancer Patients: A Radiation Therapy Oncology Group Analysis

Purpose: To analyze the prospectively collected health-related quality-of-life (HRQOL) data from patients enrolled in two Radiation Therapy Oncology Group randomized Phase III head and neck cancer trials (90-03 and 91-11) to assess their value as an independent prognostic factor for locoregional control (LRC) and/or overall survival (OS). Methods and Materials: HRQOL questionnaires, using a validated instrument, the Functional Assessment of Cancer Therapy-Head and Neck (FACT-H and N), version 2, were completed by patients before the start of treatment. OS and LRC were the outcome measures analyzed using a multivariate Cox proportional hazard model. Results: Baseline FACT-H and N data were available for 1,093 patients and missing for 417 patients. No significant difference in outcome was found between the patients with and without baseline FACT-H and N data (p = 0.58). The median follow-up time was 27.2 months for all patients and 49 months for surviving patients. Multivariate analyses were performed for both OS and LRC. Beyond tumor and nodal stage, Karnofsky performance status, primary site, cigarette use, use of concurrent chemotherapy, and altered fractionation schedules, the FACT-H and N score was independently predictive of LRC (but not OS), with p = 0.0038. The functional well-being component of the FACT-H and N predicted most significantly for LRC (p = 0.0004). Conclusions: This study represents, to our knowledge, the largest analysis of HRQOL as a prognostic factor in locally advanced head and neck cancer patients. The results of this study have demonstrated the importance of baseline HRQOL as a significant and independent predictor of LRC in patients with locally advanced head and neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrating biomass quality variability in stochastic supply chain modeling and optimization for large-scale biofuel production

The production of biofuels using second-generation feedstocks has been recognized as an important alternative source of sustainable energy and its demand is expected to increase due to regulations such as the Renewable Fuel Standard. However, the pathway to biofuel industry maturity faces unique, unaddressed challenges. Here, to address this challenges, this article presents an optimization model which quantifies and controls the impact of biomass quality variability on supply chain related decisions and technology selection. We propose a two-stage stochastic programming model and associated efficient solution procedures for solving large-scale problems to (1) better represent the random nature of the biomass quality (defined by moisture and ash contents) in supply chain modeling, and (2) assess the impact of these uncertainties on the supply chain design and planning. The proposed model is then applied to a case study in the state of Tennessee. Results show that high moisture and ash contents negatively impact the unit delivery cost since poor biomass quality requires the addition of quality control activities. Experimental results indicate that supply chain cost could increase as much as 27%–31% when biomass quality is poor. We assess the impact of the biomass quality on the topological supply chain. Our case study indicates that biomass quality impacts supply chain costs; thus, it is important to consider the impact of biomass quality in supply chain design and management decisions.

09 BIOMASS FUELS↗

Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation

Purpose: Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol.Methods: A previously designed flow phantom, capable of producing predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared.Results: The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2 ± 1.1% (total calculated output contrast mass error) with a goodness of fit (R{sup 2}) of greater than 0.99 ± 0.0035 (n= 10). The DCE-CT QA protocol was capable of detecting significant deviations from the expected phantom result when scanning at low mAs and low kVp in terms of quantitative metrics (Injected Mass Error 15.4%), goodness of fit (R{sup 2}) of 0.91, and ROI sensitivity (increase in minimum input function ROI radius by 146 ± 86%). These tests also confirmed that the ASIR reconstruction process was beneficial in reducing noise without substantially increasing partial volume effects and that vendor specific modes (e.g., axial shuttle) did not significantly affect the phantom results. The phantom and QA protocol were finally able to quickly (<90 min) and successfully validate the DCE-CT imaging protocol utilized at the three separate institutions of a multicenter clinical trial; thereby enhancing the confidence in the patient data collected.Conclusions: A DCE QA protocol was developed that, in combination with a dynamic multimodality flow phantom, allows the intrascanner variability to be separated from other sources of variability such as the impact of injection protocol and ROI selection. This provides a valuable resource that can be utilized at various clinical trial institutions to test conformance with imaging protocols and accuracy requirements as well as ensure that the scanners are performing as expected for dynamic scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-136: Assessment of Seasonal Linear Accelerator Output Variations and Associated Impacts

Purpose: Application of process control theory in quality assurance programs promises to allow earlier identification of problems and potentially better quality in delivery than traditional paradigms based primarily on tolerances and action levels. The purpose of this project was to characterize underlying seasonal variations in linear accelerator output that can be used to improve performance or trigger preemptive maintenance. Methods: Review of runtime plots of daily (6 MV) output data acquired using in house ion chamber based devices over three years and for fifteen linear accelerators of varying make and model were evaluated. Shifts in output due to known interventions with the machines were subtracted from the data to model an uncorrected scenario for each linear accelerator. Observable linear trends were also removed from the data prior to evaluation of periodic variations. Results: Runtime plots of output revealed sinusoidal, seasonal variations that were consistent across all units, irrespective of manufacturer, model or age of machine. The average amplitude of the variation was on the order of 1%. Peak and minimum variations were found to correspond to early April and September, respectively. Approximately 48% of output adjustments made over the period examined were potentially avoidable if baseline levels had corresponded to the mean output, rather than to points near a peak or valley. Linear trends were observed for three of the fifteen units, with annual increases in output ranging from 2–3%. Conclusion: Characterization of cyclical seasonal trends allows for better separation of potentially innate accelerator behaviour from other behaviours (e.g. linear trends) that may be better described as true out of control states (i.e. non-stochastic deviations from otherwise expected behavior) and could indicate service requirements. Results also pointed to an optimal setpoint for accelerators such that output of machines is maintained within set tolerances and interventions are required less frequently.

07 ISOTOPE AND RADIATION SOURCES↗

Statistical process control for IMRT dosimetric verification

Patient-specific measurements are typically used to validate the dosimetry of intensity-modulated radiotherapy (IMRT). To evaluate the dosimetric performance over time of our IMRT process, we have used statistical process control (SPC) concepts to analyze the measurements from 330 head and neck (H and N) treatment plans. The objectives of the present work are to: (i) Review the dosimetric measurements of a large series of consecutive head and neck treatment plans to better understand appropriate dosimetric tolerances; (ii) analyze the results with SPC to develop action levels for measured discrepancies; (iii) develop estimates for the number of measurements that are required to describe IMRT dosimetry in the clinical setting; and (iv) evaluate with SPC a new beam model in our planning system. H and N IMRT cases were planned with the PINNACLE{sup 3} treatment planning system versions 6.2b or 7.6c (Philips Medical Systems, Madison, WI) and treated on Varian (Palo Alto, CA) or Elekta (Crawley, UK) linacs. As part of regular quality assurance, plans were recalculated on a 20-cm-diam cylindrical phantom, and ion chamber measurements were made in high-dose volumes (the PTV with highest dose) and in low-dose volumes (spinal cord organ-at-risk, OR). Differences between the planned and measured doses were recorded as a percentage of the planned dose. Differences were stable over time. Measurements with PINNACLE{sup 3} 6.2b and Varian linacs showed a mean difference of 0.6% for PTVs (n=149, range, -4.3% to 6.6%), while OR measurements showed a larger systematic discrepancy (mean 4.5%, range -4.5% to 16.3%) that was due to well-known limitations of the MLC model in the earlier version of the planning system. Measurements with PINNACLE{sup 3} 7.6c and Varian linacs demonstrated a mean difference of 0.2% for PTVs (n=160, range, -3.0%, to 5.0%) and -1.0% for ORs (range -5.8% to 4.4%). The capability index (ratio of specification range to range of the data) was 1.3 for the PTV data, indicating that almost all measurements were within {+-}5%. We have used SPC tools to evaluate a new beam model in our planning system to produce a systematic difference of -0.6% for PTVs and 0.4% for ORs, although the number of measurements is smaller (n=25). Analysis of this large series of H and N IMRT measurements demonstrated that our IMRT dosimetry was stable over time and within accepted tolerances. These data provide useful information for assessing alterations to beam models in the planning system. IMRT is enhanced by the addition of statistical process control to traditional quality control procedures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Role of biogeochemistry in efficient shale oil and gas production

The advent and advancement in hydraulic fracturing techniques have resulted in the rapid growth of unconventional shale oil and gas production over the last couple of decades. Unlike conventional hydrocarbon systems, these shale formations serve as both the source and reservoir and therefore are directly drilled into for hydrocarbon production. Studies in different shale basins have revealed that these reservoirs are geologically complex, heterogeneous, and every play is unique. Therefore, for efficient hydrocarbon recovery, physicochemical, and mechanical attributes of individual shale reservoir need to be taken into account. Even after significant technological advancements, we are still struggling to understand the spatiotemporal variations in type and amount of hydrocarbon produced within a single basin, rapid declines in hydrocarbon production, and the low fracturing fluid recovery rates. In this review article, we briefly summarize how biogeochemical tools can be used to 1) understand variations in the quantity of organic matter (OM) that ultimately controls production of hydrocarbon, 2) determine variations in the quality of OM that ultimately controls the quality and type of hydrocarbons generated, 3) predict the fracturing potential of rock, and 4) increase efficiency of hydrocarbon production by controlling the water-rock-microbe interactions that ensue after hydraulic fracturing fluids are injected into the shale reservoirs. A better understanding and utilization of these biogeochemical processes and tools will help identify sweet spots for shale gas drilling, increase hydrocarbon recovery and open up the possibility of engineering the hydraulic fracturing fluids to enhance recovery and life of these shale reservoirs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Crystalline InGaAs/InP Dense Micro-Pillar Forest on Poly-Silicon Substrates for Low-Cost High-Efficiency Solar Cells

The ultimate goal of this project is to develop a photovoltaic system high conversion efficiency (>20%) using high quality III-V compound-based three-dimensional micro-structures on silicon and poly-silicon. Such a PV-system could be of very low cost due to minimum usages of III-V materials. This project will address the barriers that currently hamper the performance of solar cells based on three-dimensional micro-structures. To accomplish this goal the project is divided into 4 tasks, each dealing with a different aspect of the project: materials quality, micropillar growth control, light management, and pillar based solar cells. Materials Quality: the internal quantum efficiency (IQE) - by which is meant here the internal fluorescence yield - of the micro-pillars has to be increased. We aim at achieving an IQE of 45% by the end of the first year. By the end of the second year there will be a go-no-go milestone of 65% IQE. By the end of year 3 and 4 we aim to achieve 75% and 90% IQE, respectively. Micropillar growth control: dense forests of micropillars with high fill ratios need to be grown. Pillars within forests should show minimum variations in size. We aim at achieving fill ratios of 2%, 10%, >15%, >20% in years 1, 2, 3, and 4, respectively. Variations in dimension should be minimized by site-controlled growth of pillars. By the end of year 1 we will aim at achieving site-controlled growth with > 15% yield. By end of year 2 the variation of critical pillar dimensions should be less than 25%. Light management: high light absorption in the spectral range of the sun has been to be demonstrated for the micropillar forests. By the end of year 1 we will employ FDTD simulation techniques to demonstrate that pillar forests with fill ratios <20% can achieve 99% light absorption. By end of year 2 our original goal was to demonstrate >85% absorption. By end of year 3 > 90% absorption should be demonstrated. Pillar based solar cells: devices will be studied to explore ways to achieve high open-circuit voltages which will lead to high efficiency micropillar-based solar cells. We will start on single pillar devices and the findings in these studies should pave the way for devices based on forests/ arrays of pillars. By the end of the second year we aim to demonstrate a single pillar device with an open-circuit voltage of 0.7 V, as well as a pillar-forest based device with 8% conversion efficiency. By the end of year 3 these numbers should be improved to 0.9 V open-circuit voltage for single pillar devices and >15% efficiency for forest/array-based devices. We will aim to realize a device with 20% efficiency by the end of the project period.

Chang-Hasnain, Constance↗

Randomized Comparison of Whole Brain Radiotherapy, 20 Gy in Four Daily Fractions Versus 40 Gy in 20 Twice-Daily Fractions, for Brain Metastases

Purpose: The present study compared the intracranial control rate and quality of life for two radiation fractionation schemes for cerebral metastases. Methods and Materials: A total of 113 patients with a Eastern Cooperative Oncology Group performance status <3; and stable (>2 months), absent, or concurrent presentation of extracranial disease were randomized to 40 Gy in 20 twice-daily fractions (Arm A) or 20 Gy in four daily fractions (Arm B), stratified by resection status. The European Organization for Research and Treatment of Cancer Quality of Life 30-item questionnaire was administered monthly during Year 1, bimonthly during Year 2, and then every 6 months to Year 5. Results: The patient age range was 28-83 years (mean 62). Of the 113 patients, 41 had undergone surgical resection, and 74 patients had extracranial disease (31 concurrent and 43 stable). The median survival time was 6.1 months in Arm A and 6.6 months in Arm B, and the overall 5-year survival rate was 3.5%. Intracranial progression occurred in 44% of Arm A and 64% of Arm B patients (p = .03). Salvage surgery or radiotherapy was used in 4% of Arm A patients and 21% of Arm B patients (p = .004). Death was attributed to central nervous system progression in 32% of patients in Arm A and 52% of patients in Arm B (p = .03). The toxicity was minimal, with a minor increase in short-term cutaneous reactions in Arm A. The patients' quality of life was not impaired by the more intense treatment in Arm A. Conclusion: Intracranial disease control was improved and the quality of life was maintained with 40 Gy in 20 twice-daily fractions. This schema should be considered for better prognosis subgroups of patients with cerebral metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effective Materials Property Information Management for the 21st Century

This paper discusses key principles for the development of materials property information management software systems. There are growing needs for automated materials information management in various organizations. In part these are fuelled by the demands for higher efficiency in material testing, product design and engineering analysis. But equally important, organizations are being driven by the needs for consistency, quality and traceability of data, as well as control of access to proprietary or sensitive information. Further, the use of increasingly sophisticated nonlinear, anisotropic and multi-scale engineering analyses requires both processing of large volumes of test data for development of constitutive models and complex materials data input for Computer-Aided Engineering (CAE) software. And finally, the globalization of economy often generates great needs for sharing a single gold source of materials information between members of global engineering teams in extended supply-chains. Fortunately material property management systems have kept pace with the growing user demands and evolved to versatile data management systems that can be customized to specific user needs. The more sophisticated of these provide facilities for: (i) data management functions such as access, version, and quality controls; (ii) a wide range of data import, export and analysis capabilities; (iii) data pedigree traceability mechanisms; (iv) data searching, reporting and viewing tools; and (v) access to the information via a wide range of interfaces. In this paper the important requirements for advanced material data management systems, future challenges and opportunities such as automated error checking, data quality characterization, identification of gaps in datasets, as well as functionalities and business models to fuel database growth and maintenance are discussed.

36 MATERIALS SCIENCE↗

Using an oxygen content indicator in a coal-dust boiler fuel controller

The results of installing a circuit for regulating the fuel input to the 300 MW coal-dust power plant at the Novocherkassk State Regional Electric Power Plant (Novocherkasskaya GRES) based on an indicator of the oxygen content in the flue gases are described. The goal is to improve the quality of the controller response to perturbations in the fuel channel. The system and its structure are described, as well as transient control processes in the original and new systems in response to standard perturbations. The regulation quality is at least twice as good in the new scheme.

01 COAL, LIGNITE, AND PEAT↗

STRONG LENS TIME DELAY CHALLENGE. II. RESULTS OF TDC1

We present the results of the first strong lens time delay challenge. The motivation, experimental design, and entry level challenge are described in a companion paper. This paper presents the main challenge, TDC1, which consisted of analyzing thousands of simulated light curves blindly. The observational properties of the light curves cover the range in quality obtained for current targeted efforts (e.g., COSMOGRAIL) and expected from future synoptic surveys (e.g., LSST), and include simulated systematic errors. Seven teams participated in TDC1, submitting results from 78 different method variants. After describing each method, we compute and analyze basic statistics measuring accuracy (or bias) A, goodness of fit χ{sup 2}, precision P, and success rate f. For some methods we identify outliers as an important issue. Other methods show that outliers can be controlled via visual inspection or conservative quality control. Several methods are competitive, i.e., give |A| < 0.03, P < 0.03, and χ{sup 2} < 1.5, with some of the methods already reaching sub-percent accuracy. The fraction of light curves yielding a time delay measurement is typically in the range f = 20%-40%. It depends strongly on the quality of the data: COSMOGRAIL-quality cadence and light curve lengths yield significantly higher f than does sparser sampling. Taking the results of TDC1 at face value, we estimate that LSST should provide around 400 robust time-delay measurements, each with P < 0.03 and |A| < 0.01, comparable to current lens modeling uncertainties. In terms of observing strategies, we find that A and f depend mostly on season length, while P depends mostly on cadence and campaign duration.

79 ASTRONOMY AND ASTROPHYSICS↗

Quality of Radiotherapy Reporting in Randomized Controlled Trials of Hodgkin's Lymphoma and Non-Hodgkin's Lymphoma: A Systematic Review

Purpose: Standards for the reporting of radiotherapy details in randomized controlled trials (RCTs) are lacking. Although radiotherapy (RT) is an important component of curative therapy for Hodgkin's lymphoma (HL) and non-Hodgkin's lymphoma (NHL), we postulated that RT reporting may be inadequate in Phase III HL and NHL trials. Methods and Materials: We searched PubMed and the Cochrane registry for reports of RCTs involving RT and either HL or NHL published between 1998 and 2007. We screened 133 titles and abstracts to identify relevant studies. We included a total of 61 reports. We assessed these reports for the presence of six quality measures: target volume, radiation dose, fractionation, radiation prescription, quality assurance (QA) process use, and adherence to QA (i.e., reporting of major or minor deviations). Results: Of 61 reports, 23 (38%) described the target volume. Of the 42 reports involving involved-field RT alone, only 8 (19%) adequately described the target volume. The radiation dose and fractionation was described in most reports (54 reports [89%] and 39 reports [64%], respectively). Thirteen reports specified the RT prescription point (21%). Only 12 reports (20%) described using a RT QA process, and 7 reports (11%) described adherence to the QA process. Conclusion: Reporting of RT in HL and NHL RCTs is deficient. Because the interpretation, replication, and application of RCT results depend on adequate description and QA of therapeutic interventions, consensus standards for RT reporting should be developed and integrated into the peer-review process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Hotelling’s T{sup 2} charts in monitoring quality parameters in a drinking water supply system

In water supply systems with distribution networkthe most critical aspects of control and Monitoring of water quality, which generates crises system, are the effects of cross-contamination originated by the network typology. The classics of control of quality systems through the application of Shewhart charts are generally difficult to manage in real time due to the high number of charts that must be completed and evaluated. As an alternative to the traditional control systems with Shewhart charts, this study aimed to apply a simplified methodology of a monitoring plan quality parameters in a drinking water distribution, by applying Hotelling’s T{sup 2} charts and supplemented with Shewhart charts with Bonferroni limits system, whenever instabilities with processes were detected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of a Single-Power Two-Circuit ESR Process with Current-Carrying Mold: Mathematical Simulation of the Process and Experimental Verification

A novel single-power two-circuit ESR process (ESR-STCCM) with current-carrying mold has been investigated via numerical simulation and experimental research in this paper. A 2D quasi-steady-state mathematical model is developed to describe ESR-STCCM. The electromagnetic field, flow field, slag pool temperature distribution, and the shape of a molten steel pool in ESR-STCCM have been investigated by FLUENT software as well as user-defined functions (UDF). The results indicate that ESR-STCCM is different from the conventional ESR process. The maximum electromagnetic force, current density, Joule heat, and slag pool flow velocity are located in the lower part of the conductor in the ESR-STCCM process. The direction of the maximum electromagnetic force inclines upward. There are two distinct vortices in the slag pool. The larger swirl rotates counterclockwise near the conductor, with a value of 0.0263 m s{sup −1} due to the interaction of the electromagnetic force and gravity. The maximum temperature of the slag pool is 2070 K (1797 °C) and is located in the center of the swirl with a filling ratio of 0.6 and a 20 mm electrode immersion depth. The depth of a molten steel pool is shallower, which is conducive to improving solidification quality. In addition, the filling ratio of 0.6 is conducive to controlling steel solidification quality. Some experiments have been done, and the numerical model is confirmed by experimental results.

36 MATERIALS SCIENCE↗

Defining a Use Case for ADMS Testbed: Data Quality Requirements for ADMS Deployment

Advanced distribution management systems (ADMS) provide a suite of tools to meet the needs of a modern grid: increased reliability and power quality, improved resiliency and security, reduced costs, and enhanced customer participation. A critical challenge that utilities face with adoption of ADMS is the quality of models and data that the ADMS uses for making control decisions. Data quality has a two-fold impact on ADMS adoption: 1. Data quality improvement might constitute up to 25% of ADMS deployment costs. 2. The accuracy of data and models used by the ADMS affects the utility's ability to meet its operational objectives. Thus, quantifying the data quality requirements and its impact on performance is critical to reducing the overall cost of deployment, enabling increased adoption and ensuring that the ADMS performs as specified. This paper offers the motivation, methodology, and evaluation strategy to fill this critical gap.

24 POWER TRANSMISSION AND DISTRIBUTION↗