Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Structural evaluation of candidate space shuttle thermal protection systems

The characteristics and development of a lightweight reusable thermal protection system for the space shuttle are discussed. The test articles consisted of metallic substrates with upper surfaces covered with all-silica, reusable, surface insulation material. The material is processed in the form of tiles. The external surfaces of the tiles are provided with a coating system which consists of a borosilicate coating with a silicon carbide emittance agent and impregnation with a hydrophobic agent. The finished tiles are attached to the metal substrate by adhesive bonding. Charts and graphs of the properties of the material are provided.

Burns, A. B.↗

Contributions to the acoustic protection of civil buildings taking into account the use of light prefabs

Usually it is expensive to obtain suitable damping coefficients for exterior and interior walls made up of light materials. Hence, acoustic protection problems must be tackled in parallel with the design and introduction of new types of elements. A comparison of classical solutions shows that interior separating walls raise the most difficult problems. In order to reduce building costs it is necessary to make a careful study of architectural solutions and to provide for wall structures with characteristics that vary with the particular case.

Smigelschi, M.↗

Development and Design Application of Rigidized Surface Insulation Thermal Protection Systems, Volume 1

Materials and design technology of the all-silica LI-900 rigid surface insulation (RSI) thermal protection system (TPS) concept for the shuttle spacecraft is presented. All results of contract development efforts are documented. Engineering design and analysis of RSI strain arrestor plate material selections, sizing, and weight studies are reported. A shuttle prototype test panel was designed, analyzed, fabricated, and delivered. Thermophysical and mechanical properties of LI-900 were experimentally established and reported. Environmental tests, including simulations of shuttle loads represented by thermal response, turbulent duct, convective cycling, and chemical tolerance tests are described and results reported. Descriptions of material test samples and panels fabricated for testing are included. Descriptions of analytical sizing and design procedures are presented in a manner formulated to allow competent engineering organizations to perform rational design studies. Results of parametric studies involving material and system variables are reported. Material performance and design data are also delineated.

Source record↗

Techniques for aerothermal tests of large, flightweight thermal protection panels in a Mach 7 wind tunnel

Thermal performance and structural integrity are experimentally evaluated in the Langley 8-ft high temperature structures tunnel, which uses a combustion products test medium to provide realistic combinations of aerodynamic heating and loading. Recently developed techniques provide independent control of rate and magnitude of surface heating and differential pressure, protection against adverse acoustics buffeting during facility starting and stopping, programed radiant heating before exposing test panels to the high energy stream, and infrared radiometry for detailed surface temperatures. These techniques were verified repeatedly by return of useful data on metallic and nonmetallic panel concepts of reusable surface insulation.

Deveikis, W. D.↗

Final analysis and design of a thermal protection system for 8-foot HTST combustor

The cylindrical shell combustor with T-bar supports in the 8-foot HTST at the NASA-Langley Research Center encountered vibratory fatigue cracking over a period of 50-250 tunnel tests within a limited range of the required operating envelope. A preliminary design study provided several suitable thermal protection system designs for the combustor, one of which was a two-pass regenerative type air-cooled omega-shaped segment liner. A final design layout of the omega segment liner was prepared and analyzed for steady-state and transient conditions. The design of a support system for the fuel spray bar assembly was also included. Detail drawings suitable for fabrication purposes were also prepared. Liner design problems defined during the preliminary study included (1) the ingress of gas into the attachment bulb section of the omega segment, (2) the large thermal gradient along the leg of the omega bulb attachment section and, (3) the local peak metal temperature at the radius between the liner ID and the leg of the bulb attachment. These were resolved during the final design task. Analyses of the final design of the omega segment liner indicated that all design goals were met and the design provided the capability of operating over the required test envelope with a life expectancy substantially above the goal of 1500 cycles.

Moskowitz, S.↗

Environmental protection of titanium alloys at high temperatures

Various concepts were evaluated for protecting titanium alloys from oxygen contamination at 922 K (1200 F) and from hot-salt stress-corrosion at 755 K (900 F). It is indicated that oxygen-contamination resistance can be provided by a number of systems, but for hot-salt stress-corrosion resistance, factors such as coating integrity become very important. Titanium aluminides resist oxygen ingress at 922 K through the formation of alumina (on TiAl3) or modified TiO2 (on Ti3Al, TiAl) scales. TiAl has some resistance to attack by hot salt, but has limited ductility. Ductile Ti-Ni and Ti-Nb-Cr-Al alloys provide limited resistance to oxygen ingress, but are not greatly susceptible to hot-salt stress-corrosion cracking.

Wright, I. G.↗

Thermal-Structural Evaluation of TD Ni-20Cr Thermal Protection System Panels

The results of a thermal-structural test program to verify the performance of a metallic/radiative Thermal Protection System (TPS) under reentry conditions are presented. This TPS panel is suitable for multiple reentry, high L/D space vehicles, such as the NASA space shuttle, having surface temperatures up to 1200 C (2200 F). The TPS panel tested consists of a corrugation-stiffened, beaded-skin TD Ni-20Cr metallic heat shield backed by a flexible fibrous quartz and radiative shield insulative system. Test conditions simulated the critical heating and aerodynamic pressure environments expected during 100 repeated missions of a reentry vehicle. Temperatures were measured during each reentry cycle; heat-shield flatness surveys to measure permanent set of the metallic components were made every 10 cycles. The TPS panel, in spite of localized surface failures, performed its designated function.

Eidinoff, H. L.↗

Evaluation of coated columbium alloy heat shields for space shuttle thermal protection system application. Volume 3, phase 3: Full size TPS evaluation

The thermal protection system (TPS), designed for incorporation with space shuttle orbiter systems, consists of one primary heat shield thermally and structurally isolated from the test fixture by eight peripheral guard panels, all encompassing an area of approximately 12 sq ft. TPS components include tee-stiffened Cb 752/R-512E heat shields, bi-metallic support posts, panel retainers, and high temperature insulation blankets. The vehicle primary structure was simulated by a titanium skin, frames, and stiffeners. Test procedures, manufacturing processes, and methods of analysis are fully documented. For Vol. 1, see N72-30948; for Vol. 2, see N74-15660.

Baer, J. W.↗

Thermoacoustic fatigue testing facility for space shuttle thermal protection system

The development of a reusable space shuttle by NASA in the next decade depends in part on the design of a satisfactory thermal protection system (TPS). The booster and orbiter parts of the shuttle require TPS panels which will withstand thermoacoustic fatigue. The Langley Research Center has begun tests on early panel designs in a new acoustic fatigue facility which is capable of simulating the combined elevated temperature and acoustic environments which these panels are expected to experience. The capabilities of the facility and computer system are outlined, and problems encountered in establishing the test methods are discussed. Tests of a Haynes 25 TPS panel are described, and representative data from tests of the panel at 650 C are included.

Rucker, C. E.↗

Ablative thermal protection for space tug multipass, aerobraking entry

Analytical studies had found the employment of an aerobraking trajectory for return of a reusable Space Tug from geosynchronous missions to be feasible and practical. To establish the minimum-weight ablative dome heat shield, trajectories involving 2 and 30 perigee passes were investigated both analytically and by plasma arc testing. Silicone-base ablators with densities of 15, 30, and 50 lb/cu ft were selected for evaluation. All models withstood the multipass exposures without deleterius surface recession or char erosion. Dome heat shield weights based on optimum ablative compositions indicated that ablators are a highly efficient thermal protection system for these missions.

Strauss, E. L.↗

Thermal and heat flow instrumentation for the space shuttle Thermal Protection System

The 100 mission lifetime requirement for the space shuttle orbiter vehicle dictates a unique set of requirements for the Thermal Protection System (TPS) thermal and heat flow instrumentation. This paper describes the design and development of such instrumentation with emphasis on assessment of the accuracy of the measurements when the instrumentation is an integral part of the TPS. The temperature and heat flow sensors considered for this application are described and the optimum choices discussed. Installation techniques are explored and the resulting impact on the system error defined.

Hartman, G. J.↗

Development of a fused slurry silicide coating for the protection of tantalum alloys

Results are reported of a research program to develop a reliable high-performance, fused slurry silicide protective coating for a tantalum-10 tungsten alloy for use at 1427 to 1538 C at 0.1 to 10 torr air pressure under cyclic temperature conditions. A review of silicide coating performance under these conditions indicated that the primary wear-out mode is associated with widening of hairline fissures in the coating. Consideration has been given to modifying the oxidation products that form on the coating surface to provide a seal for these fissures and to minimize their widening. On the basis of an analysis of the phase relationships between silica and various other oxides, a coating having the slurry composition 2.5Mn-33Ti-64.5Si was developed that is effective in the pressure range from 1 to 10 torr.

Packer, C. M.↗

Fiber-modified polyurethane foam for ballistic protection

Closed-cell, semirigid, fiber-loaded, self-extinguishing polyurethane foam material fills voids around fuel cells in aircraft. Material prevents leakage of fuel and spreading of fire in case of ballistic incendiary impact. It also protects fuel cell in case of exterior fire.

Fish, R. H.↗

Tests of protective clothing for the safe handling of pressurized lamps

Tests were made to find a clothing material combination for use in handling high-pressure lamps. Monofilament nylon, ballistic nylon, and ballistic felt grouped into various multilayer combinations and chromed leather were positioned around and 30 cm (12 in.) away from exploding high-pressure lamps of different manufacturers and wattages. The results are: (1) 5024 nylon/ballistic felt/5024 nylon in a layered configuration was not penetrated by fragments of lamps as large as 6.5 kW; (2) this layered combination is lightweight and pliable and offers greater mobility and comfort to the user than previous protective clothing; and (3) Lexan plastic 1.6 mm (1/6 in.) thick to be used for face shield material showed no penetration for lamps as large as 20 kW.

Ewashinka, J. G.↗

Prediction and verification of creep behavior in metallic materials and components, for the space shuttle thermal protection system. Volume 1, phase 1: Cyclic materials creep predictions

Cyclic creep response was investigated and design methods applicable to thermal protection system structures were developed. The steady-state (constant temperature and load) and cyclic creep response characteristics of four alloys were studied. Steady-state creep data were gathered through a literature survey to establish reference data bases. These data bases were used to develop empirical equations describing creep as a function of time, temperature, and stress and as a basis of comparison for test data. Steady-state creep tests and tensile cyclic tests were conducted. The following factors were investigated: material thickness and rolling direction; material cyclic creep response under varying loads and temperatures; constant stress and temperature cycles representing flight conditions; changing stresses present in a creeping beam as a result of stress redistribution; and complex stress and temperature profiles representative of space shuttle orbiter trajectories. A computer program was written, applying creep hardening theories and empirical equations for creep, to aid in analysis of test data. Results are considered applicable to a variety of structures which are cyclicly exposed to creep producing thermal environments.

Davis, J. W.↗

Prediction and verification of creep behavior in metallic materials and components for the space shuttle thermal protection system. Volume 2: Phase 2 subsize panel cyclic creep predictions

A method for predicting permanent cyclic creep deflections in stiffened panel structures was developed. The resulting computer program may be applied to either the time-hardening or strain-hardening theories of creep accumulation. Iterative techniques were used to determine structural rotations, creep strains, and stresses as a function of time. Deflections were determined by numerical integration of structural rotations along the panel length. The analytical approach was developed for analyzing thin-gage entry vehicle metallic-thermal-protection system panels subjected to cyclic bending loads at high temperatures, but may be applied to any panel subjected to bending loads. Predicted panel creep deflections were compared with results from cyclic tests of subsize corrugation and rib-stiffened panels. Empirical equations were developed for each material based on correlation with tensile cyclic creep data and both the subsize panels and tensile specimens were fabricated from the same sheet material. For Vol. 1, see N75-21431.

Cramer, B. A.↗

The relative effects of entry parameters on thermal protection system weight

Shielding a spacecraft from the severe thermal environment of an atmospheric entry requires a sophisticated thermal protection system (TPS). Thermal computer program models were developed for two such TPS designs proposed for the space shuttle orbiter. The multilayer systems, a reusable surface insulation TPS, and a re-radiative metallic skin TPS, were sized for a cross-section of trajectories in the entry corridor. This analysis indicates the relative influence of the entry parameters on the weight of each TPS concept. The results are summarized graphically. The trajectory variables considered were down-range, cross-range, orbit inclination, entry interface velocity and flight path angle, maximum heating rate level, angle of attack, and ballistic coefficient. Variations in cross-range and flight path angle over the ranges considered had virtually no effect on the required entry TPS weight. The TPS weight was significantly more sensitive to variations in angle of attack than to dispersions in the other trajectory considered.

Hirasaki, P. N.↗

Prediction and verification of creep behavior in metallic materials and components for the space shuttle thermal protection system. Volume 3, phase 3: Full size heat shield data correlation and design criteria

Analysis methods for predicting cyclic creep deflection in stiffened metal panel structures, were applied to full size panels. Results were compared with measured deflections from cyclic tests of thin gage L605, Rene' 41, and TDNiCr full size corrugation stiffened panels. A design criteria was then formulated for metallic thermal protection panels subjected to creep. A computer program was developed to calculate creep deflections.

Cramer, B. A.↗