Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Equipment for subcriticality monitoring by pulse method - 240

At the present time methods and means of determining, evaluating, and monitoring the effective neutron multiplication factor or the subcriticality are becoming very important for validating and monitoring nuclear safety in connection with the accumulation of a large number of spent fuel assemblies and the transition to a more tight mode of their storage arrangement in the spent-fuel pools of NPP. Pulse method is an effective subcriticality monitoring tool for subcritical reactors and spent nuclear fuel storages. This method is based on the use neutron generator, fission chambers and instrumentation for data acquisition and processing. The measurement and control equipment was designed. It allows: neutron pulses generation with specified parameters; neutron flux response monitoring by measuring the count rate at predetermined set of sequential time intervals; data transmitting to the personal computer; data processing and subcriticality calculation; self diagnostics and health monitoring; data recording, archiving and storage. The special device is proposed to check the electronic equipment. This device simulates a signal of a neutron detector counting rate after neutron generator pulses appear. The paper presents hardware structure and composition, specification and software of the control unit, which provides neutron generator operation, data acquisition and processing. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LabVIEW-based control software for para-hydrogen induced polarization instrumentation

The elucidation of cell metabolic mechanisms is the modern underpinning of the diagnosis, treatment, and in some cases the prevention of disease. Para-Hydrogen induced polarization (PHIP) enhances magnetic resonance imaging (MRI) signals over 10 000 fold, allowing for the MRI of cell metabolic mechanisms. This signal enhancement is the result of hyperpolarizing endogenous substances used as contrast agents during imaging. PHIP instrumentation hyperpolarizes Carbon-13 ({sup 13}C) based substances using a process requiring control of a number of factors: chemical reaction timing, gas flow, monitoring of a static magnetic field (B{sub o}), radio frequency (RF) irradiation timing, reaction temperature, and gas pressures. Current PHIP instruments manually control the hyperpolarization process resulting in the lack of the precise control of factors listed above, resulting in non-reproducible results. We discuss the design and implementation of a LabVIEW based computer program that automatically and precisely controls the delivery and manipulation of gases and samples, monitoring gas pressures, environmental temperature, and RF sample irradiation. We show that the automated control over the hyperpolarization process results in the hyperpolarization of hydroxyethylpropionate. The implementation of this software provides the fast prototyping of PHIP instrumentation for the evaluation of a myriad of {sup 13}C based endogenous contrast agents used in molecular imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Optical Sensors to Minimize Energy Consumption in Polymer Extrusion Processes (Final Technical Report)

Project Objective: The objectives of this study are to develop an accurate and stable on-line sensor system to monitor color and composition on-line in polymer melts, to develop a scheme for using the output to control extruders to eliminate the energy, material and operational costs of off-specification product, and to combine or eliminate some extrusion processes. Background: Polymer extrusion processes are difficult to control because the quality achieved in the final product is complexly affected by the properties of the extruder screw, speed of extrusion, temperature, polymer composition, strength and dispersion properties of additives, and feeder system properties. Extruder systems are engineered to be highly reproducible so that when the correct settings to produce a particular product are found, that product can be reliably produced time after time. However market conditions often require changes in the final product, different products or grades may be processed in the same equipment, and feed materials vary from lot to lot. All of these changes require empirical adjustment of extruder settings to produce a product meeting specifications. Optical sensor systems that can continuously monitor the composition and color of the extruded polymer could detect process upsets, drift, blending oscillations, and changes in dispersion of additives. Development of an effective control algorithm using the output of the monitor would enable rapid corrections for changes in materials and operating conditions, thereby eliminating most of the scrap and recycle of current processing. This information could be used to identify extruder systems issues, diagnose problem sources, and suggest corrective actions in real-time to help keep extruder system settings within the optimum control region. Using these advanced optical sensor systems would give extruder operators real-time feedback from their process. They could reduce the amount of off-spec product produced and significantly reduce energy consumption. Also, because blending and dispersion of additives and components in the final product could be continuously verified, we believe that, in many cases, intermediate compounding steps could be eliminated (saving even more time and energy).

47 OTHER INSTRUMENTATION↗

Composition-tailored synthesis of gradient transition metal precursor particles for lithium-ion battery cathode materials.

We report the tailored synthesis of particles with internal gradients in transition metal composition aided by the use of a general process model. Tailored synthesis of transition metal particles was achieved using a coprecipitation reaction with tunable control over the process conditions. Gradients in the internal composition of the particles was monitored and confirmed experimentally by analysis of particles collected during regularly timed intervals. Particles collected from the reactor at the end of the process were used as the precursor material for the solid-state synthesis of Li{sub 1.2}(Mn{sub 0.62}Ni{sub 0.38}){sub 0.8}O{sub 2}, which was electrochemically evaluated as the active cathode material in a lithium battery. The Li{sub 1.2}(Mn{sub 0.62}Ni{sub 0.38}){sub 0.8}O{sub 2} material was the first example of a structurally integrated multiphase material with a tailored internal gradient in relative transition metal composition as the active cathode material in a lithium-ion battery. We believe our general synthesis strategy may be applied to produce a variety of new cathode materials with tunable interior, surface, and overall relative transition metal compositions.

25 ENERGY STORAGE↗

Qualified display system architecture - 246

There is a need in the nuclear industry for a Qualified Display System (QDS) architecture as described in this paper. The function of the QDS is to process and display Regulatory Guide 1.97 post accident monitoring parameters. The QDS is implemented on the Lockheed Martin Field-Programmable Gate Array (FPGA) based Nuclear Protection and Control (NuPAC) digital platform, coupled with a Qualified Display Controller (QDC) and a Safety Display Unit (SDU). The QDS is designed to meet the requirements of IEEE 603-1991 (endorsed by Regulatory Guide 1.153, Rev. 1), IEEE 497-2002 (endorsed by Regulatory Guide 1.97, Rev. 4), and IEEE 7-4.3.2- 2003 (endorsed by Regulatory Guide 1.152, Rev. 3). The QDS is designed with flexibility such that it can be implemented in an advanced reactor design, Small Modular Reactor (SMR) with any cooling medium, or digital upgrade project for an operating nuclear plant. The QDS has four independent and redundant divisions. Each division has five layers in the architecture: Process variable input signals; Process Protection Logic (PPL); Algorithm Logic (AL), Interface Panel (IP); and Safety Display Unit (SDU). The QDS meets the following design criteria: redundancy, independence, predictability and repeatability, and diversity capability. The QDS architecture also meets the simplicity design principle. The QDS architecture design provides flexibility in the implementation in a plant. The QDS can be implemented in the design of a new advanced plant or as a digital upgrade in an operating plant. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development and validation of instantaneous risk model in nuclear power plant's risk monitor

The instantaneous risk model is the fundament of calculation and analysis in a risk monitor. This study focused on the development and validation of an instantaneous risk model. Therefore the principles converting from the baseline risk model to the instantaneous risk model were studied and separated trains' failure modes modeling method was developed. The development and validation process in an operating nuclear power plant's risk monitor were also introduced. Correctness of instantaneous risk model and rationality of converting method were demonstrated by comparison with the result of baseline risk model. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Long-Range Order of Cylinders in Diblock Copolymer Thin Films Using Graphoepitaxy

Topographically patterned substrates are known to induce long-range lateral order in spherical diblock copolymers, but it is not clear that similar confinement will also order cylindrical diblock copolymers across the whole surface. The role of graphoepitaxial parameters including trough width and mesa height on the ordering process of cylindrical domains in diblock copolymers thin films is monitored in this study. The quantification of order was achieved by the calculation of an order parameter of the hexagonally packed cylinders. These results demonstrate that graphoepitaxy is an effective method to induce long-range order in cylindrical domain diblock copolymer systems. An increase in order was observed in samples prepared on the mesas and in troughs of widths up to 20 m, and mesa heights greater than 1.0 but less than 5.0 L0 The role of molecular weight on the kinetics of the ordering process of cylindrical domains in diblock copolymers thin films is also monitored in this study, where ordering is readily observed for lower molecular weight copolymers (number average molecular weight, Mn=63,000), but not for larger copolymers (Mn=230,000). The reduction of the rate of formation of long-range order is attributed to the impeded diffusion of higher molecular weight polymers. These results demonstrate that there will exist upper limits on the molecular weights of diblock copolymers that can be used to create nanoscale templates with longrange order, which also translates to an upper limit in pore size and spacing in these templates.

36 MATERIALS SCIENCE↗

R and D on Proton Extinction Monitor for COMET Project

The COMET experiment searches for a muon to electron conversion process that is one of the lepton flavor violation processes. We use an 8-GeV pulsed proton beam. The proton extinction ratio is an important parameter. In order to measure this ratio pulse-by-pulse, we are developing a monitoring device. This device is called Proton Extinction Monitor and is a gas Cerenkov detector with gating photomultiplier tubes(PMT). The result of the investigation is that ethane is a promising gas for the Cerenkov radiator gas. A gating PMT is under development. We fabricated a divider circuit which switches at 10-kHz and has a cutoff ratio of 10{sup -6}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing a strategy for the national coordinated soil moisture monitoring network

Soil moisture is a critical land surface variable, affecting a wide variety of climatological, agricultural, and hydrological processes. Determining the current soil moisture status is possible via a variety of methods, including in situ monitoring, remote sensing, and numerical modeling. Although all of these approaches are rapidly evolving, there is no cohesive strategy or framework to integrate these diverse information sources to develop and disseminate coordinated national soil moisture products that will improve our ability to understand climate variability. The National Coordinated Soil Moisture Monitoring Network initiative has developed a national strategy for network coordination with NOAA's National Integrated Drought Information System. The strategy is currently in review within NOAA, and work is underway to implement the initial milestones of the strategy. This update reviews the goals and steps being taken to establish this national-scale coordination for soil moisture monitoring in the United States.

54 ENVIRONMENTAL SCIENCES↗

Recursive Gaussian Process over graphs for Integrating Multi-timescale Measurements in Low-Observable Distribution Systems

The transition to a smarter grid is empowered by enhanced sensor deployments and smart metering infrastructure in the distribution system. Measurements from these sensors and meters can be used for many applications, including distribution system state estimation (DSSE). However, these measurements are typically sampled at different rates and could be intermittent due to losses during the aggregation process. These multi timescale measurements should be reconciled in real-time to perform accurate grid monitoring. This paper tackles this problem by formulating a recursive multi-task Gaussian process (RGP-G) approach that sequentially aggregates sensor measurements. Specifically, we formulate a recursive multi-task GP with and without network connectivity information to reconcile the multi time-scale measurements in distribution systems. Here, the proposed framework is capable of aggregating the multi-time scale measurements batch-wise or in real-time. Following the aggregation of the multi time-scale measurements, the spatial states of the consistent time-series are estimated using matrix completion based DSSE approach. Simulation results on IEEE 37 and IEEE 123 bus test systems illustrate the efficiency of the proposed methods from the standpoint of both multi time-scale data aggregation and DSSE.

42 ENGINEERING↗

DOE Hydrogen Sorption Center of Excellence: Synthesis and Processing of Single-Walled Carbon Nanohorns for Hydrogen Storage and Catalyst Supports

The objective of the project was to exploit the unique morphology, tunable porosity and excellent metal supportability of single-walled carbon nanohorns (SWNHs) to optimize hydrogen uptake and binding energy through an understanding of metal-carbon interactions and nanoscale confinement. SWNHs provided a unique material to understand these effects because they are carbon nanomaterials which are synthesized from the 'bottom-up' with well-defined, sub-nm pores and consist of single-layer graphene, rolled up into closed, conical, horn-shaped units which form ball-shaped aggregates of {approx}100-nm diameter. SWNHs were synthesized without metal catalysts by the high-temperature vaporization of solid carbon, so they can be used to explore metal-free hydrogen storage. However, SWNHs can also be decorated with metal nanoparticles or coatings in post-processing treatments to understand how metals augment hydrogen storage. The project first explored how the synthesis and processing of SWNHs could be modified to tailor pore sizes to optimal size ranges. Nanohorns were rapidly synthesized at 20g/hr rates by high-power laser vaporization enabling studies such as neutron scattering with gram quantities. Diagnostics of the synthesis process including high-speed videography, fast pyrometry of the graphite target, and differential mobility analysis monitoring of particle size distributions were applied in this project to provide in situ process control of SWNH morphology, and to understand the conditions for different pore sizes. We conclude that the high-temperature carbon-vaporization process to synthesize SWNHs is scalable, and can be performed by electric arc or other similar techniques as economically as carbon can be vaporized. However, the laser vaporization approach was utilized in this project to permit the precise tuning of the synthesis process through adjustment of the laser pulse width and repetition rate. A result of this processing control in the project was to eliminate the large (2-3 nm) internal pores of typical SWNHs which were found not to store hydrogen effectively. Post processing treatments of the as-synthesized SWNHs focused on pore size, surface area, and metal decoration in order to understand the effects of each on measured hydrogen uptake. Wet chemistry and gas-phase oxidation treatments were developed throughout the life of the project to adjust the interstitial and slit pore sizes of the as-produced SWNHs, and increase the surface area to a maximum value of 2200 m2/g. In addition, wet chemistry approaches were used to develop methods to decorate the nanohorns with small Pt and Pd nanoparticles for metal-assisted hydrogen storage. Finally, oxygen-free decoration of SWNHs with alkaline earth metals (Ca) was developed using pulsed laser deposition and vacuum evaporation in order to produce surface coatings with high static electric fields sufficient to polarize and bind dihydrogen. Decoration of SWNHs with Pt and Pd nanoparticles resulted in enhanced binding energy (NREL, 36 kJ/mol), as well as enhancement in the room temperature uptake of 0.6 wt.% (for undecorated, oxidized, pure-C SWNHs at 20 bar), to 1.6 wt% for Pt- and Pd-decorated SWNHs at 100 bar, comparable to MOF-177 materials. NIST neutron scattering on gram quantity Pt- and Pd-decorated SWNHs showed clear evidence for 'spillover' type losses of molecular hydrogen and determined the onset temperature for this effect to be between 150K < T < 298K.High (2142 m2/g) surface area SWNH materials with variable pore sizes and metal-decorated SWNHs were demonstrated with metals (Pt, Pd) resulting in increased excess storage (3.5 wt. % at 77K). Compression results in bulk SWNH samples with density 1.03 g/cm3, and 30 g/L volumetric capacity. In summary, SWNHs were found to be unique carbon nanomaterials which can be produced continuously at high rates from vaporization of pure carbon. Their inherent pore structure exhibits significant room temperature hydrogen storage in sub-nm pores, and their morphology serves as an excellent metal catalyst support for small (2-3 nm nanoparticles). Pt- and Pd-nanoparticle-decorated SWNHs exhibit clear evidence for metal-assisted hydrogen storage which is activated at T>150 K, permitting additional room-temperature storage up to 1.8 wt.% at 100 bar. One of the key results of the project were theoretical predictions for doped, decorated, and filled nanostructures with distributed charge to maintain high static electric fields sufficient to polarize and bind hydrogen. This concept indicates a promising new direction for hydrogen storage materials.

08 HYDROGEN↗

Applications of Antineutrino Monitoring to Nonproliferation

Antineutrinos are highly penetrating particles emitted by the fission process in operating nuclear power and research reactors. Their rate of emission and energy spectrum can provide useful information about reactor operations, including the existence of the reactor, its power level, and the fissile mass inventories in the core. Because the signal cannot be attenuated or masked, this information can be gathered at long standoff outside the core. Building on our group’s successful experimental demonstrations of plutonium content monitoring at 25 meters from a reactor core, the goal of this project is to demonstrate detectors for reactor monitoring and discovery detectors at increasing standoffs, out to a practical limit of about 1000 kilometers. Our two main goals for FY16 and 17 are: 1) design a detector capable of monitoring nuclear reactor operations at 25 kilometer standoff, and 2) engage in a cooperative effort to monitor a former plutonium production reactor in India (at close range).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Bayesian inference for high confidence signal validation and sensor calibration assessment - 328

Online Monitoring (OLM) systems has been investigated for applications in the nuclear industry for the past two decades. These systems offer economic and technological advantages over the currently implemented time based testing methods for sensors and associated instrumentations. The advantages offered not only augment economic viability of current nuclear reactors but will be an inevitable change called for to suit the technologies of the advanced reactors (Gen III+). Irrespective, the acceptance of OLM into the regulatory structure in the U.S. is still hindered by technical and structural clarity on uncertainty quantification used by these systems. A Bayesian inference technique is implemented in the form of a residual model to quantify uncertainty in OLM predictions. The developed system used Gaussian processes to represent the OLM predictions and model inadequacy, the stationary representation of model based uncertainty. In addition, model selection techniques are used in conjunction with numerical methods such as Genetic Algorithm (GA) and Gibb's sampler to add robustness to the estimation model inadequacy, particularly in the presence of drifts and faulted conditions. The prediction model developed herein find applicability in fault detection, obtaining real values of processes after the onset of faults etc. Further development looks into the extension of current method for a multiple output scale implementation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

From Solidification Processing to Microstructure to Mechanical Properties: A Multi-scale X-ray Study of an Al-Cu Alloy Sample

We follow an Al-12 at. pct Cu alloy sample from the liquid state to mechanical failure, using in situ X-ray radiography during directional solidification and tensile testing, as well as three-dimensional computed tomography of the microstructure before and after mechanical testing. The solidification processing stage is simulated with a multi-scale dendritic needle network model, and the micromechanical behavior of the solidified microstructure is simulated using voxelized tomography data and an elasto-viscoplastic fast Fourier transform model. This study demonstrates the feasibility of direct in situ monitoring of a metal alloy microstructure from the liquid processing stage up to its mechanical failure, supported by quantitative simulations of microstructure formation and its mechanical behavior.

36 MATERIALS SCIENCE↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 2. Quantitative Moisture Dynamics Estimation Model

Abstract The long‐term containment of high‐level radioactive waste in geological disposal repositories relies on Engineered Barrier Systems (EBS), with bentonite clay emerging as a candidate material due to its unique properties. Understanding moisture dynamics within bentonite buffers is crucial for EBS performance, as it directly influences the material's swelling capacity, thermal and hydraulic conductivity, mechanical properties, and long‐term evolution under complex thermal‐hydrological‐mechanical (THM) processes. This study develops an advanced Electrical Resistivity Tomography (ERT)‐based framework to quantitatively monitor moisture dynamics under THM conditions. Our framework extends the Waxman‐Smits model to incorporate the coupled effects of temperature, water content, fluid chemistry, and mechanical changes on bentonite's electrical properties. Utilizing HotBENT‐Lab data from our companion paper, which includes electrical conductivity, CT density, and thermocouple measurements, this study offers a novel methodological framework bridging different scales of the model. Our results show that the extended model can estimate water content from ERT data, capturing spatial and temporal variations in moisture distribution within bentonite columns. However, the model tends to overestimate water content compared to CT density‐derived measurements. We address this discrepancy by incorporating a simplified swelling effect model, which improves agreement between ERT and CT density‐based water content estimates. We also discuss model limitations, including simplified treatment of swelling and micropore effects, and propose a conceptual framework for transitioning from laboratory to field applications, addressing challenges such as parameter scalability, field validation methods, and integration of diverse data sources. This ERT‐based framework can potentially advance real‐world moisture monitoring of bentonite‐based EBS in nuclear waste repositories. Plain Language Summary Safely containing high‐level radioactive waste depends on barriers made from materials like bentonite clay, which is effective because it swells and seals in the waste. To ensure these barriers work well over time, it's important to understand how moisture moves through the clay. Our study developed a new method using ERT to monitor moisture levels in bentonite under conditions that mimic those in actual storage sites, including changes in temperature, water content, and mechanical stress. This study improved an existing model to better account for how these factors affect the clay, allowing us to create more accurate moisture maps. Initially, the proposed model overestimated the amount of water in the clay, but its accuracy was improved by factoring in how the clay swells when wet. This study also identified some limitations of the model and suggested ways to adapt it for use in real‐world waste storage sites. This new approach could lead to better monitoring and safety checks for nuclear waste storage systems, helping to ensure long‐term containment. Key Points This work develops an ERT‐based framework extending the Waxman‐Smits model to monitor bentonite moisture dynamics during coupled THM processes The extended model accurately estimates water content from Electrical Resistivity Tomography data, incorporating swelling effects to improve precision This work proposes a conceptual framework for transitioning from laboratory to field applications, advancing EBS monitoring in nuclear waste repositories

Chen, Hang↗

SU-G-TeP4-07: Automatic EPID-Based 2D Measurement of MLC Leaf Offset as a Quality Control Tool

Purpose: The MLC dosimetric leaf gap (DLG) and transmission are measured parameters which impact the dosimetric accuracy of IMRT and VMAT plans. This investigation aims to develop an efficient and accurate routine constancy check of the physical DLG in two dimensions. Methods: The manufacturer’s recommended DLG measurement method was modified by using 5 fields instead of 11 and by utilizing the Electronic Portal Imaging Device (EPID). Validations were accomplished using an ion chamber (IC) in solid water and a 2D IC array. EPID data was collected for 6 months on multiple TrueBeam linacs using both Millennium and HD MLCs at 5 different clinics in an international consortium. Matlab code was written to automatically analyze the images and calculate the 2D results. Sensitivity was investigated by introducing deliberate leaf position errors. MLC calibration and initialization history was recorded to allow quantification of their impact. Results were analyzed using statistical process control (SPC). Results: The EPID method took approximately 5 minutes. Due to detector response, the EPID measured DLG and transmission differed from the IC values but were reproducible and consistent with changes measured using the ICs. For the Millennium MLC, the EPID measured DLG and transmission were both consistently lower than IC results. The EPID method was implemented as leaf offset and transmission constancy tests (LOC and TC). Based on 6 months of measurements, the initial leaf-specific action thresholds for changes from baseline were set to 0.1 mm. Upper and lower control limits for variation were developed for each machine. Conclusion: Leaf offset and transmission constancy tests were implemented on Varian HD and Millennium MLCs using an EPID and found to be efficient and accurate. The test is effective for monitoring MLC performance using dynamic delivery and performing process control on the DLG in 2D, thus enhancing dosimetric accuracy. This work was supported by a grant from Varian Medical Systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

CoDCon Project: FY 2019 Status Report

The co-decontamination (CoDCon) project was established in FY 2016 with the objectives of (a) evaluating the uncertainty in the uranium (U)/plutonium (Pu) ratio in a mixed U/Pu product from a tributyl phosphate (TBP)–based solvent extraction flowsheet and (b) developing and demonstrating on-line optical spectroscopy for real-time monitoring of key components (e.g., Pu, U, and HNO 3 concentrations) in the process solutions. We are interested in establishing the accuracy and precision to which a specific uranium-to-plutonium (U/Pu) ratio can be achieved, which for the purposes of this project is set at a U/Pu mass ratio of 7/3. The uncertainty associated with achieving this specific target U/Pu ratio is being established through multiple flowsheet tests using laboratory-scale solvent extraction equipment. In addition, optical spectroscopic techniques have been incorporated into the CoDCon solvent extraction testing system, allowing real time monitoring of all input and output process streams. Two CoDCon flowsheet tests were successfully performed in FY 2018. In FY 2019, two additional flowsheet tests were performed. For the first of these (CoDCon Run 3), the dissolved fuel simulant was similar to that used in the first two tests, with the inclusion of 1 mM neptunium (Np). The second test conducted in FY 2019 (CoDCon Run 4) used a more representative dissolved fuel simulant, including addition of non-radioactive fission product elements. All tests used a bank of sixteen 2 cm centrifugal contactors. The tests involved first loading the solvent (30 vol% TBP dissolved in n-dodecane) with U and Pu, then the Pu was stripped from the loaded solvent with a U(IV) solution (~50 mM) and the flowsheet conditions were adjusted such that some U partitioned into the Pu-containing product stream. The amount of U accompanying the Pu was monitored in real time using optical spectroscopic techniques coupled with chemometric modeling. Based on the real-time spectroscopic measurement of the U/Pu ratio, adjustments were made to the flowrate of the fresh TBP solvent phase used to scrub U from the aqueous Pu-containing product. This proved to be a very effective way to control the U/Pu mass ratio in the product.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗