Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Calibration of the Forward Scattering Spectrometer Probe used on the ER-2 during the Airborne Antarctic Ozone Experiment

The Particle Measuring Systems (PMS) Forwared Scattering Spectrometer Probe (FSSP-100) which was flown on the ER-2 during the Airborne Antarctic Ozone Experiment for the measurement of particles in polar stratospheric clouds has been evaluated and calibrated. The sample volume of the probe per 10-s sampling period increases from 257 cu cm for 1-micron particles to 412 for 15-micron particles, but there is substantial uncertainty in this value. Limitations in the measurements from this instrument and possible corrections are discussed. The uncertainty in the total particle mass measured by the probe may be as large as + or - 100 percent. Recommendations are given for the processing of data from the FSSP used in this project.

Baumgardner, Darrel↗

Development of a phase Doppler based probe for icing cloud droplet characterization

The development and evaluation of a compact optical fiber probe (OFP) for airborne and wind tunnel icing cloud characterizations is described. This probe was based upon the proven phase Doppler technique for measuring the size and velocity of spherical drops. Direct comparisons of the size distributions from the standard PDPA with the OFP were used to confirm the reliability of the probe. After some improvements in the fiber coupling efficiency, the number density and liquid water content data agreed to within 15 percent.

Rudoff, R. C.↗

Solar probe mission status

The penetration of coronal regions by a solar probe employing planetary gravity-assist trajectories to attain perihelia of only a few solar radii will allow unique in situ experiments to be conducted. The trajectory design options will fundamentally impact solar probe spacecraft design criteria. The aerogravity-assist method, which requires the bending of a trajectory in the vicinity of a planet by passing through a portion of its atmosphere will yield large changes in direction and velocity. This option would in the case of a solar probe mission involve the use of either the earth or Venus as a target for a specially aerodynamically configured 'waverider' spacecraft with L/D of the order of 10.

Randolph, J. E.↗

The extension of the Cassini spacecraft/Titan probe to the exploration of Neptune/Triton

NASA and ESA are planning a mission named 'Cassini' to place a spacecraft in Saturn orbit and deposit an atmospheric probe into the atmosphere of Titan. It is expected that the upcoming close flyby of Neptune and Triton by Voyager 2 will increase future scientific interest in more intensive exploration of that system. The purpose of this paper is to examine the feasibility of the extension of the Cassini spacecraft and Titan Probe designs to this expected future scientific need for longer-term orbital observations of Neptune and its satellites and for in situ exploration of the suspected Triton atmosphere with a probe vehicle.

Wercinski, Paul F.↗

Contact Probe With Pivoting Tip

Sensor probe follows curved contours, always keeping sensor in contact with contoured surface. Includes freely pivoting tip, which contains sensor. Spring holds tip in contact with surface being scanned. As user moves probe along surface, force of contact keeps tip oriented along local perpendicular to surface. Slopes of up to 90 degrees from axis of probe accommodated.

Amos, Jay M.↗

Probe insertion apparatus with inflatable seal

A sealing apparatus is disclosed for inserting a probe into a pressure vessel having an elongated opening includes a pair of resiliently deformable seals opposingly disposed in sealing engagement with each other. A retainer is connected to the pressure vessel around the elongated opening and holds the pair of seals rigidly to the pressure vessel. A wedge is engageable with the pair of seals and carries the probe, for longitudinally translating the probe in pressure vessel.

Trimarchi, Paul A.↗

Air deployed expendable probes in oceanographic research

Physical oceanographic instrumentation is both nonexpendable and expendable. Expendable instruments for both shipboard and aircraft use were developed which yield moderate accuracy and precision at a low or moderate unit cost and which may be deployed by less trained personnel on less specialized platforms both in more extreme environmental conditions and while underway. While shipboard expendables are familiar to many researchers, most are not familiar with the variety of air deployable expendables available, although the quasi-synoptic, 3-D view of the ocean that aerial studies yield can be very valuable in oceanographic research. As well as acoustic oriented probes, air deployed sensors exist for the measurement of temperature, sound speed, currents, and optical properties, and work is underway to develop probes measuring simultaneous conductivity and temperature. In addition, low cost drifting buoys with both oceanographic and meteorological sensors are available, and ice penetrating probes are being developed for arctic research. Characteristics of these instruments are presented, along with examples of their use and a discussion of some of their not so well publicized shortcomings.

Boyd, Janice D.↗

Laser transit anemometer and Pitot probe comparative measurements in a sharp cone boundary layer at Mach 4

Laser transit anemometer (LTA) measurements of a 7 degree sharp cone boundary layer were conducted in the Air Force/AEDC Supersonic Tunnel A Mach 4 flow field. These measurements are compared with Pitot probe measurements and tricone theory provided by AEDC staff. Measurements were made both in laminar and turbulent boundary layers of the model. Comparison of LTA measurements with theory showed agreement to better than 1 percent for the laminar boundary layer cases. This level of agreement was obtained after small position corrections, 0.01 to 0.6 mm, were applied to the experimental data sets. Pitot probe data when compared with theory also showed small positioning errors. The Pitot data value was also limited due to probe interference with the flow near the model. The LTA turbulent boundary layer data indicated a power law dependence of 6.3 to 6.9. The LTA data was analyzed in the time (Tau) domain in which it was obtained and in the velocity domain. No significant differences were noted between Tau and velocity domain results except in one turbulent boundary layer case.

Hunter, W. W., Jr.↗

A probe for real-time images of particle beams and their analyses in a merged-beams apparatus

A real-time charged particle beam probe was developed, which can be used both as a beam diagnostic (beam tuning) and to quantitatively determine the three-dimensional density distribution of a beam. The probe consists of a microchannel plate, an aluminized phosphor screen deposited on a fiber-optic faceplate, a flexible fiber-optic bundle, and a charge injection device (CID) in tandem. Digital or analog video output of the CID is fed into a computer or oscilloscope, respectively, for analysis or observation. The probe can be moved continuously along the beams' paths to obtain 'pictures' of the beam at any desired interval, thus giving three-dimensional form factors. The beams, singly or simultaneously, may be observed on the monitor facilitating the task of beam adjustment for optimum overlap. The digital output is used for quantitative computation of the beam overlaps. The device is linear with beam intensity, but the performance degrades with time due to beam damage of the microchannel plate.

Forand, J. L.↗

Experimental and theoretical comparison of the Probe Thrust Vector Control concept

A concept that offers an alternate method for thrust vector control of liquid or solid propellant rockets is the use of a solid body or probe that is inserted on demand through the wall of the rocket nozzle. This Probe Thrust Vector Control (PTVC) concept is an alternative to that of a gimbaled nozzle or a Liquid Injection Thrust Vector control system. The viability of the PTVC concept can be assessed either experimentally and/or with the use of CFD. A purely experimental assessment is time consuming and expensive, whereas a CFD assessment is time- and cost-effective. Two key requirements of the concept are PTVC vectoring performance and active cooling requirements for the probe to maintain its thermal and structural integrity. The objective of the work reported here is presentation of experimental subscale cold flow tests and comparison of these tests with CFD predictions and the response time of the PTVC system.

Cavalleri, Robert↗

Fiber-Optic Probe For Laser Velocimetry

Size and weight of optics reduced considerably. Proposed fiber-optic probe in laser velocimeter smaller (and, therefore, lighter in weight and more maneuverable) than previous probe. Proposed configuration is product of calculations and experiments showing virtual waists serve same purpose. Laser-velocimeter lens brought close to transfer lenses to focus on virtual waists, thereby shortening probe head considerably.

Lynch, Dana H.↗

Probe shapes for streamwise momentum and cross-stream turbulence intensity

When the highly turbulent flowfields at the edges of jets, in augmentors, and in other jet-mixing devices are surveyed with conventional pitot probes, the values indicated by the instruments may contain a significant increment brought about by the dynamics of the eddies. Although the influence of turbulence on the measurements is usually negligible in streams where the turbulence level is 1 percent or less, the effect of turbulence on static and total pressure measurements can be around 20 percent when the turbulence level exceeds 40 percent. This paper describes a theoretical study that develops probe shapes that directly measure the time-averaged total pressure based on the streamwise component of the velocity vector to obtain a direct measurement of the streamwise momentum. The difference between the time-averaged pressure indicated by such a probe and one that measures the total head based on the entire velocity vector yields the cross-stream turbulence intensity.

Rossow, Vernon, J.↗

Possible wave amplitudes in shocks in the solar corona - Predictions for Solar Probe

Terrestrial shock measurements are scaled to coronal parameters to demonstrate the need for improvements for the Solar Probe instrumentation. A model of coronal shock is presented to estimate corresponding shock parameters, and a comparison is made with ISEE 3 crossings to examine terrestrial bow shock and wave activity downstream. The turbulence in the magnetosheath is scaled to predict the specific range of amplitudes and frequencies of wave regions that the Solar Probe can encounter. The high velocity of the spacecraft at perihelion constrains the potential application of present instrumentation. In order to properly characterize the coronal shocks the Solar Probe requires instrumentation that can detect shock-generated Alfven waves Doppler-shifted to frequencies of a few kHz.

Moses, S. L.↗

Measuring ionospheric electron density using the plasma frequency probe

During the past decade, the plasma frequency probe (PFP) has evolved into an accurate, proven method of measuring electron density in the ionosphere above about 90 km. The instrument uses an electrically short antenna mounted on a sounding rocket that is immersed in the plasma and notes the frequency where the antenna impedance is large and nonreactive. This frequency is closely related to the plasma frequency, which is a direct function of free electron concentration. The probe uses phase-locked loop technology to follow a changing electron density. Several sections of the plasma frequency probe circuitry are unique, especially the voltage-controlled oscillator that uses both an electronically tuned capacitor and inductor to give the wide tuning range needed for electron density measurements. The results from two recent sounding rocket flights (Thunderstorm II and CRIT II) under vastly different plasma conditions demonstrate the capabilities of the PFP and show the importance of in situ electron density measurements of understanding plasma processes.

Jensen, Mark D.↗

Neptune atmospheric probe mission

A feasibility study of a 'Galileo-like' atmospheric probe mission to Neptune aimed at obtaining in situ measurements of atmospheric and cloud composition and structure is presented. The main scientific desire is to obtain in situ measurements down to a pressure level of 75-100 bars to completely penetrate the CH4, NH3, H2S, NH4SH, and H2O clouds. The probe mission should be based on a Galileo complement of instruments with the addition of a gas chromatograph. Particular attention is given to the deployment design, and operation of the atmospheric entry probe system to accomplish the above mission objective.

Swenson, Byron L.↗

Correction analysis for a supersonic water cooled total temperature probe tested to 1370 K

The authors address the thermal analysis of a water cooled supersonic total temperature probe tested in a Mach 2 flow, up to 1366 K total temperature. The goal of this experiment was the determination of high-temperature supersonic jet mean flow temperatures. An 8.99 cm exit diameter water cooled nozzle was used in the tests. It was designed for exit Mach 2 at 1366 K exit total temperature. Data along the jet centerline were obtained for total temperatures of 755 K, 1089 K, and 1366 K. The data from the total temperature probe were affected by the water coolant. The probe was tested through a range of temperatures between 755 K and 1366 K with and without the cooling system turned on. The results were used to develop a relationship between the indicated thermocouple bead temperature and the freestream total temperature. The analysis and calculated temperatures are presented.

Lagen, Nicholas T.↗

A fine-wire thermocouple probe for measurement of stagnation temperatures in real gas hypersonic flows of nitrogen

A fine-wire thermocouple probe was used to determine freestream stagnation temperatures in hypersonic flows. Data were gathered in a N2 blowdown wind tunnel with runtimes of 1-5 s. Tests were made at supply pressures between 30 and 1400 atm and supply temperatures between 700 and 1900 K, with Mach numbers of 14 to 16. An iterative procedure requiring thermocouple data, pilot pressure measurements, and supply conditions was used to determine test cell stagnation temperatures. Probe conduction and radiation losses, as well as real gas behavior of N2, were accounted for during analysis. Temperature measurement error was found to be 5 to 10 percent. A correlation was drawn between thermocouple diameter Reynolds number and temperature recovery ratio. Transient probe behavior was studied and was found to be adequate in temperature gradients up to 1000 K/s.

Hollis, Brian R.↗

A Fiber Optic Probe for the Detection of Cataracts

A compact fiber optic probe developed for on-orbit science experiments was used to detect the onset of cataracts, a capability that could eliminate physicians' guesswork and result in new drugs to 'dissolve' or slow down the cataract formation before surgery is necessary. The probe is based upon dynamic light scattering (DLS) principles. It has no moving parts, no apertures, and requires no optical alignment. It is flexible and easy to use. Results are presented for excised but intact human eye lenses. In a clinical setting, the device can be easily incorporated into a slit-lamp apparatus (ophthalmoscope) for complete eye diagnostics. In this set-up, the integrated fiber optic probe, the size of a pencil, delivers a low power cone of laser light into the eye of a patient and guides the light which is backscattered by the protein molecules of the lens through a receiving optical fiber to a photo detector. The non-invasive DLS measurements provide rapid determination of protein crystalline size and its size distribution in the eye lens.

Ansari, Rafat R.↗