Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Probability distributions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Probabilistic Zonal Reserve Requirements for Improved Energy Deliverability with Wind Power

In power systems with high penetration of renewable energy resources, uncertainty and variability of these stochastic resources introduce additional challenges for the operation of power systems. To improve the power system's reliability in the face of uncertainty, reserves are required as additional generation capacity to rebalance the power system following random disturbances. However, reserve deliverability is not guaranteed, because it may encounter potential transmission line congestion. Zonal reserve requirements can address this issue, but operators lack efficient ways to allocate reserves to zones while accounting for wind power forecast uncertainty. Herein we propose a methodology for probabilistic zonal reserve requirements to address wind power forecast uncertainties. This method estimates the probability distribution of line flows based on the system generation margin and injection shift factor. This estimate is then used to construct pre-defined and post-zonal reserve requirements. Case studies demonstrate that the proposed method efficiently schedules energy and reserves to balance energy and manage deliverability with wind power forecast uncertainty.We also discuss operational implications of the proposed method.

17 WIND ENERGY↗

A Machine Learning-based Reliability Evaluation Model for Integrated Power-Gas Systems

This article proposes a hybrid machine learning method for the reliability evaluation of integrated power-gas systems (IPGS) under the uncertain component failure probability distributions. The Random Forest (RF) method is designed to select important features to solve the insufficient quantity of data and the curse of dimensionality problems. The Extreme Gradient Boosting (XGBoost) regression algorithm is developed to quantify the relationship between the uncertain parameters and reliability metrics. Moreover, a ten-fold cross-validation method is employed to further improve the accuracy of the regression model. Simulation results on three test systems show that the proposed method can achieve high accuracy for the reliability evaluation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Wind Power Uncertainty Intervals for Electricity Market Operation

It is important to select an appropriate uncertainty level of the wind power forecast for power system scheduling and electricity market operation. Traditional methods hedge against a predefined level of wind power uncertainty, such as a specific confidence interval or uncertainty set, which leaves the questions of how to best select the appropriate uncertainty levels. To bridge this gap, this paper proposes a model to optimize the forecast uncertainty intervals of wind power for power system scheduling problems, with the aim of achieving the best trade-off between economics and reliability. Then we reformulate and linearize the models into a mixed integer linear programming (MILP) without strong assumptions on the shape of the probability distribution. In order to invest the impacts on cost, reliability, and prices in a electricity market, we apply the proposed model on a twosettlement electricity market based on a six-bus test system and on a power system representing the U.S. state of Illinois. The results show that the proposed method can not only help to balance the economics and reliability of the power system scheduling, but also help to stabilize the energy prices in electricity market operation.

electricity market↗

Changes in geophysical properties caused by fluid injection into porous rocks: analytical models: Geophysical changes in porous rocks

Analytical models are provided that describe how the elastic compliance, electrical conductivity, and fluid-flow permeability of rocks depend on stress and fluid pressure. In order to explain published laboratory data on how seismic velocities and electrical conductivity vary in sandstones and granites, the models require a population of cracks to be present in a possibly porous host phase. The central objective is to obtain a consistent mean-field analytical model that shows how each modeled rock property depends on the nature of the crack population. We describe the crack populations by a crack density, a probability distribution for the crack apertures and radii, and the averaged orientation of the cracks. The possibly anisotropic nature of the elasticity, conductivity, and permeability tensors is allowed for; however, only the isotropic limit is used when comparing to laboratory data. For the transport properties of conductivity and permeability, the percolation effect of the crack population linking up to form a connected path across a sample is modeled. But, this effect is important only in crystalline rock where the host phase has very small conductivity and permeability. In general, the importance of the crack population to the transport properties increases as the host phase becomes less conductive and less permeable.

58 GEOSCIENCES↗

Investment risk in bioenergy crops

Here, perennial, cellulosic bioenergy crops represent a risky investment. The potential for adoption of these crops depends not only on mean net returns, but also on the associated probability distributions and on the risk preferences of farmers. Using 6-year observed crop yield data from highly productive and marginally productive sites in the southern Great Lakes region and assuming risk neutrality, we calculate expected breakeven biomass yields and prices compared to corn ( Zea mays L.) as a benchmark. Next we develop Monte Carlo budget simulations based on stochastic crop prices and yields. The crop yield simulations decompose yield risk into three components: crop establishment survival, time to maturity, and mature yield variability. Results reveal that corn with harvest of grain and 38% of stover (as cellulosic bioenergy feedstock) is both the most profitable and the least risky investment option. It dominates all perennial systems considered across a wide range of farmer risk preferences. Although not currently attractive for profit-oriented farmers who are risk neutral or risk averse, perennial bioenergy crops.

09 BIOMASS FUELS↗

Thermophysical modeling of raw glaze liquidus temperature and viscosity

Raw glazes, which do not contain pre-melted glass frits, are widely used due to their low cost. The natural variability of the mineral compositions used in raw glazes affects their viscosity during firing. Molten glaze viscosity plays an important role in determining the final surface quality; therefore, it is important to determine how raw glaze composition and firing conditions affect viscosity. Thermophysical modeling provides a way to evaluate the liquidus temperature and viscosity of molten glazes as a function of composition and oxygen activity. Equilibrium phase volume fraction and composition of 242 raw glaze recipes were evaluated under oxidizing and reducing conditions. Undissolved or precipitation of solid phases explain the secondary flux transition from anti-fluxing to fluxing near the liquidus temperature. The liquidus temperature and viscosity of iron glazes decrease as a function of increasing iron content under a reducing atmosphere. The empirical probability distribution of molten glaze viscosity follows a lognormal distribution, with lead glazes having significantly lower viscosity compared with glazes without lead. Here, the peak firing temperature viscosity of lead-free glazes is near the working point of glass. Multiple linear regression analysis shows that the peak firing temperature viscosity and liquidus temperature significantly predict the viscosity factor.

36 MATERIALS SCIENCE↗

Self-calibration of photometric redshift scatter in weak-lensing surveys

Photo-z errors, especially catastrophic errors, are a major uncertainty for precision weak lensing cosmology. We find that the shear-(galaxy number) density and density-density cross correlation measurements between photo-z bins, available from the same lensing surveys, contain valuable information for self-calibration of the scattering probabilities between the true-z and photo-z bins. The self-calibration technique we propose does not rely on cosmological priors nor parameterization of the photo-z probability distribution function, and preserves all of the cosmological information available from shear-shear measurement. We estimate the calibration accuracy through the Fisher matrix formalism. We find that, for advanced lensing surveys such as the planned stage IV surveys, the rate of photo-z outliers can be determined with statistical uncertainties of 0.01-1% for z < 2 galaxies. Among the several sources of calibration error that we identify and investigate, the galaxy distribution bias is likely the most dominant systematic error, whereby photo-z outliers have different redshift distributions and/or bias than non-outliers from the same bin. This bias affects all photo-z calibration techniques based on correlation measurements. As a result, galaxy bias variations of O(0.1) produce biases in photo-z outlier rates similar to the statistical errors of our method, so this galaxy distribution bias may bias the reconstructed scatters at several-σ level, but is unlikely to completely invalidate the self-calibration technique.

79 ASTRONOMY AND ASTROPHYSICS↗

A Bayesian Approach for Extracting Fluorescence Lifetimes from Sparse Data Sets and Its Significance for Imaging Experiments

The measurement of fluorescence lifetimes, especially in small sample volumes, presents the dual challenge of probing a small number of fluorophores and fitting the concomitant sparse data set to the appropriate excited-state decay function. A common method of analysis, such as the maximum likelihood (ML) technique, assumes a uniform probability distribution of the parameters describing the fluorescence decay function. An improvement is thus suggested by implementing a suitable nonuniform distribution, as is provided by a Bayesian framework, where the distribution of parameters is obtained from both their prior knowledge and the evidence-based likelihood of an event for a given set of parameters. We have also considered the Dirichlet prior distribution, whose mathematical form enables analytical solutions of the fitting parameters to be rapidly obtained. If Gaussian and exponential prior distributions are judiciously chosen, they reproduce the experimental target lifetime to within 20% with as few as 20 total photon counts for the data set, as does the Dirichlet prior distribution. But because of the analytical solutions afforded by the Dirichlet prior distribution, it is proposed to employ a Dirichlet prior to search parameter space rapidly to provide, if necessary, appropriate parameters for subsequent employment of a Gaussian or exponential prior distribution

97 MATHEMATICS AND COMPUTING↗

A Bayesian nonparametric analysis for zero-inflated multivariate count data with application to microbiome study

High-throughput sequencing technology has enabled researchers to profile microbial communities from a variety of environments, but analysis of multivariate taxon count data remains challenging. Here, we develop a Bayesian nonparametric (BNP) regression model with zero inflation to analyse multivariate count data from microbiome studies. A BNP approach flexibly models microbial associations with covariates, such as environmental factors and clinical characteristics. The model produces estimates for probability distributions which relate microbial diversity and differential abundance to covariates, and facilitates community comparisons beyond those provided by simple statistical tests. We compare the model to simpler models and popular alternatives in simulation studies, showing, in addition to these additional community-level insights, it yields superior parameter estimates and model fit in various settings. The model's utility is demonstrated by applying it to a chronic wound microbiome data set and a Human Microbiome Project data set, where it is used to compare microbial communities present in different environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of residual target motion for image-tracked spine radiosurgery

A quality assurance method was developed to investigate the effects of residual target motion for hypofractionated spine radiosurgery. The residual target motion (target movement between successive image-guided corrections) was measured on-line via dual x-ray imagers for patients treated with CyberKnife (Accuray, Inc., Sunnyvale, CA), a robotic linear accelerator with intrafractional image-tracking capability. The six degree-of-freedom characteristics of the residual target motion were analyzed, the effects of such motion on patient treatment delivery were investigated by incorporating the probability distribution of the residual motion into the treatment planning dose calculations, and deviations of the doses from those originally planned were calculated. Measurements using a programmable motion phantom were also carried out and compared with the static treatment plan calculations. It was found that the residual target motions were patient specific and typically on the order of 2 mm. The measured dose distributions incorporating the residual target motion also exhibited 2.0 mm discrepancy at the prescription isodose level when compared with the static treatment plan calculations. For certain patients, residual errors introduced significant uncertainties ({approx}1 Gy) for the dose delivered to the spinal cord, especially at the high dose levels covering a small volume of the spinal cord (e.g., 0.1 cc). In such cases, stringent cord constraints and frequent monitoring of the target position should be implemented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel method to calibrate DOI function of a PET detector with a dual-ended-scintillator readout

The detection of depth-of-interaction (DOI) is a critical detector capability to improve the PET spatial resolution uniformity across the field-of-view and will significantly enhance, in particular, small bore system performance for brain, breast, and small animal imaging. One promising technique of DOI detection is to use dual-ended-scintillator readout that uses two photon sensors to detect scintillation light from both ends of a scintillator array and estimate DOI based on the ratio of signals (similar to Anger logic). This approach needs a careful DOI function calibration to establish accurate relationship between DOI and signal ratios, and to recalibrate if the detection condition is shifted due to the drift of sensor gain, bias variations, or degraded optical coupling, etc. However, the current calibration method that uses coincident events to locate interaction positions inside a single scintillator crystal has severe drawbacks, such as complicated setup, long and repetitive measurements, and being prone to errors from various possible misalignments among the source and detector components. This method is also not practically suitable to calibrate multiple DOI functions of a crystal array. To solve these problems, a new method has been developed that requires only a uniform flood source to irradiate a crystal array without the need to locate the interaction positions, and calculates DOI functions based solely on the uniform probability distribution of interactions over DOI positions without knowledge or assumption of detector responses. Simulation and experiment have been studied to validate the new method, and the results show that the new method, with a simple setup and one single measurement, can provide consistent and accurate DOI functions for the entire array of multiple scintillator crystals. This will enable an accurate, simple, and practical DOI function calibration for the PET detectors based on the design of dual-ended-scintillator readout. In addition, the new method can be generally applied to calibrating other types of detectors that use the similar dual-ended readout to acquire the radiation interaction position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Segmenting CT prostate images using population and patient-specific statistics for radiotherapy

Purpose: In the segmentation of sequential treatment-time CT prostate images acquired in image-guided radiotherapy, accurately capturing the intrapatient variation of the patient under therapy is more important than capturing interpatient variation. However, using the traditional deformable-model-based segmentation methods, it is difficult to capture intrapatient variation when the number of samples from the same patient is limited. This article presents a new deformable model, designed specifically for segmenting sequential CT images of the prostate, which leverages both population and patient-specific statistics to accurately capture the intrapatient variation of the patient under therapy. Methods: The novelty of the proposed method is twofold: First, a weighted combination of gradient and probability distribution function (PDF) features is used to build the appearance model to guide model deformation. The strengths of each feature type are emphasized by dynamically adjusting the weight between the profile-based gradient features and the local-region-based PDF features during the optimization process. An additional novel aspect of the gradient-based features is that, to alleviate the effect of feature inconsistency in the regions of gas and bone adjacent to the prostate, the optimal profile length at each landmark is calculated by statistically investigating the intensity profile in the training set. The resulting gradient-PDF combined feature produces more accurate and robust segmentations than general gradient features. Second, an online learning mechanism is used to build shape and appearance statistics for accurately capturing intrapatient variation. Results: The performance of the proposed method was evaluated on 306 images of the 24 patients. Compared to traditional gradient features, the proposed gradient-PDF combination features brought 5.2% increment in the success ratio of segmentation (from 94.1% to 99.3%). To evaluate the effectiveness of online learning mechanism, the authors carried out a comparison between partial online update strategy and full online update strategy. Using the full online update strategy, the mean DSC was improved from 86.6% to 89.3% with 2.8% gain. On the basis of full online update strategy, the manual modification before online update strategy was introduced and tested, the best performance was obtained; here, the mean DSC and the mean ASD achieved 92.4% and 1.47 mm, respectively. Conclusions: The proposed prostate segmentation method provided accurate and robust segmentation results for CT images even under the situation where the samples of patient under radiotherapy were limited. A conclusion that the proposed method is suitable for clinical application can be drawn.

60 APPLIED LIFE SCIENCES↗

Statistical analysis of dose heterogeneity in circulating blood: Implications for sequential methods of total body irradiation

Purpose: Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these ''sequential'' techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Methods: Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. Results: The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than {+-}10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times. However, the EUD was unaffected (within 10%) for perfusion periods of less than 150 s or treatment times of 20 min or greater. Treatment over six fractions improved the EUD per fraction such that all parametric combinations resulted in unaffected EUD. The stochastic models confirmed these results. Conclusions: Dose heterogeneity in circulating blood cells is clinically acceptable for typical treatment times, perfusion rates, and cell types. Development of conformal, sequential TBI treatment techniques should not be withheld based on concerns over circulating blood dose heterogeneity.

60 APPLIED LIFE SCIENCES↗

4D tumor centroid tracking using orthogonal 2D dynamic MRI: Implications for radiotherapy planning

Purpose: Current pretreatment, 4D imaging techniques are suboptimal in that they sample breathing motion over a very limited “snapshot” in time. Heretofore, long-duration, 4D motion characterization for radiotherapy planning, margin optimization, and validation have been impractical for safety reasons, requiring invasive markers imaged under x-ray fluoroscopy. To characterize 3D tumor motion and associated variability over durations more consistent with treatments, the authors have developed a practical dynamic MRI (dMRI) technique employing two orthogonal planes acquired in a continuous, interleaved fashion.Methods: 2D balanced steady-state free precession MRI was acquired continuously over 9–14 min at approximately 4 Hz in three healthy volunteers using a commercial 1.5 T system; alternating orthogonal imaging planes (sagittal, coronal, sagittal, etc.) were employed. The 2D in-plane pixel resolution was 2 × 2 mm{sup 2} with a 5 mm slice profile. Simultaneous with image acquisition, the authors monitored a 1D surrogate respiratory signal using a device available with the MRI system. 2D template matching-based anatomic feature registration, or tracking, was performed independently in each orientation. 4D feature tracking at the raw frame rate was derived using spline interpolation.Results: Tracking vascular features in the lung for two volunteers and pancreatic features in one volunteer, the authors have successfully demonstrated this method. Registration error, defined here as the difference between the sagittal and coronal tracking result in the SI direction, ranged from 0.7 to 1.6 mm (1σ) which was less than the acquired image resolution. Although the healthy volunteers were instructed to relax and breathe normally, significantly variable respiration was observed. To demonstrate potential applications of this technique, the authors subsequently explored the intrafraction stability of hypothetical tumoral internal target volumes and 3D spatial probability distribution functions. The surrogate respiratory information allowed the authors to show how this technique can be used to study correlations between internal and external (surrogate) information over these prolonged durations. However, compared against the gold standard of the time stamps in the dMRI frames, the temporal synchronization of the surrogate 1D respiratory information was shown to be likely unreliable.Conclusions: The authors have established viability of a novel and practical pretreatment, 4D tumor centroid tracking method employing a commercially available dynamic MRI sequence. Further developments from the vendor are likely needed to provide a reliably synchronized surrogate 1D respiratory signal, which will likely broaden the utility of this method in the pretreatment radiotherapy planning context.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose impact in radiographic lung injury following lung SBRT: Statistical analysis and geometric interpretation

Purpose: To demonstrate a new method of evaluating dose response of treatment-induced lung radiographic injury post-SBRT (stereotactic body radiotherapy) treatment and the discovery of bimodal dose behavior within clinically identified injury volumes. Methods: Follow-up CT scans at 3, 6, and 12 months were acquired from 24 patients treated with SBRT for stage-1 primary lung cancers or oligometastic lesions. Injury regions in these scans were propagated to the planning CT coordinates by performing deformable registration of the follow-ups to the planning CTs. A bimodal behavior was repeatedly observed from the probability distribution for dose values within the deformed injury regions. Based on a mixture-Gaussian assumption, an Expectation-Maximization (EM) algorithm was used to obtain characteristic parameters for such distribution. Geometric analysis was performed to interpret such parameters and infer the critical dose level that is potentially inductive of post-SBRT lung injury. Results: The Gaussian mixture obtained from the EM algorithm closely approximates the empirical dose histogram within the injury volume with good consistency. The average Kullback-Leibler divergence values between the empirical differential dose volume histogram and the EM-obtained Gaussian mixture distribution were calculated to be 0.069, 0.063, and 0.092 for the 3, 6, and 12 month follow-up groups, respectively. The lower Gaussian component was located at approximately 70% prescription dose (35 Gy) for all three follow-up time points. The higher Gaussian component, contributed by the dose received by planning target volume, was located at around 107% of the prescription dose. Geometrical analysis suggests the mean of the lower Gaussian component, located at 35 Gy, as a possible indicator for a critical dose that induces lung injury after SBRT. Conclusions: An innovative and improved method for analyzing the correspondence between lung radiographic injury and SBRT treatment dose has been demonstrated. Bimodal behavior was observed in the dose distribution of lung injury after SBRT. Novel statistical and geometrical analysis has shown that the systematically quantified low-dose peak at approximately 35 Gy, or 70% prescription dose, is a good indication of a critical dose for injury. The determined critical dose of 35 Gy resembles the critical dose volume limit of 30 Gy for ipsilateral bronchus in RTOG 0618 and results from previous studies. The authors seek to further extend this improved analysis method to a larger cohort to better understand the interpatient variation in radiographic lung injury dose response post-SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An analysis of the uncertainty and bias in DCE-MRI measurements using the spoiled gradient-recalled echo pulse sequence

Purpose: The pharmacokinetic parameters derived from dynamic contrast-enhanced (DCE) MRI have been used in more than 100 phase I trials and investigator led studies. A comparison of the absolute values of these quantities requires an estimation of their respective probability distribution function (PDF). The statistical variation of the DCE-MRI measurement is analyzed by considering the fundamental sources of error in the MR signal intensity acquired with the spoiled gradient-echo (SPGR) pulse sequence. Methods: The variance in the SPGR signal intensity arises from quadrature detection and excitation flip angle inconsistency. The noise power was measured in 11 phantoms of contrast agent concentration in the range [0–1] mM (in steps of 0.1 mM) and in onein vivo acquisition of a tumor-bearing mouse. The distribution of the flip angle was determined in a uniform 10 mM CuSO{sub 4} phantom using the spin echo double angle method. The PDF of a wide range of T1 values measured with the varying flip angle (VFA) technique was estimated through numerical simulations of the SPGR equation. The resultant uncertainty in contrast agent concentration was incorporated in the most common model of tracer exchange kinetics and the PDF of the derived pharmacokinetic parameters was studied numerically. Results: The VFA method is an unbiased technique for measuringT1 only in the absence of bias in excitation flip angle. The time-dependent concentration of the contrast agent measured in vivo is within the theoretically predicted uncertainty. The uncertainty in measuring K{sup trans} with SPGR pulse sequences is of the same order, but always higher than, the uncertainty in measuring the pre-injection longitudinal relaxation time (T1{sub 0}). The lowest achievable bias/uncertainty in estimating this parameter is approximately 20%–70% higher than the bias/uncertainty in the measurement of the pre-injection T1 map. The fractional volume parameters derived from the extended Tofts model were found to be extremely sensitive to the variance in signal intensity. The SNR of the pre-injection T1 map indicates the limiting precision with which K{sup trans} can be calculated. Conclusions: Current small-animal imaging systems and pulse sequences robust to motion artifacts have the capacity for reproducible quantitative acquisitions with DCE-MRI. In these circumstances, it is feasible to achieve a level of precision limited only by physiologic variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT

Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for clinical CT. The photon energies measured by PCDs can be distorted due to the interactions of a photon with the detector and the interaction of multiple coincident photons. These effects result in distorted recorded x-ray spectra which may lead to artifacts in reconstructed CT images and inaccuracies in tissue identification. Model-based compensation techniques have the potential to account for the distortion effects. This approach requires only a small number of parameters and is applicable to a wide range of spectra and count rates, but it needs an accurate model of the spectral distortions occurring in PCDs. The purpose of this study was to develop a model of those spectral distortions and to evaluate the model using a PCD (model DXMCT-1; DxRay, Inc., Northridge, CA) and various x-ray spectra in a wide range of count rates. Methods: The authors hypothesize that the complex phenomena of spectral distortions can be modeled by: (1) separating them into count-rate independent factors that we call the spectral response effects (SRE), and count-rate dependent factors that we call the pulse pileup effects (PPE), (2) developing separate models for SRE and PPE, and (3) cascading the SRE and PPE models into a combined SRE+PPE model that describes PCD distortions at both low and high count rates. The SRE model describes the probability distribution of the recorded spectrum, with a photo peak and a continuum tail, given the incident photon energy. Model parameters were obtained from calibration measurements with three radioisotopes and then interpolated linearly for other energies. The PPE model used was developed in the authors’ previous work [K. Taguchi et al., “Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects,” Med. Phys. 38(2), 1089–1102 (2011)]. The agreement between the x-ray spectra calculated by the cascaded SRE+PPE model and the measured spectra was evaluated for various levels of deadtime loss ratios (DLR) and incident spectral shapes, realized using different attenuators, in terms of the weighted coefficient of variation (COV{sub W}), i.e., the root mean square difference weighted by the statistical errors of the data and divided by the mean. Results: At low count rates, when DLR < 10%, the distorted spectra measured by the DXMCT-1 were in agreement with those calculated by SRE only, with COV{sub W}'s less than 4%. At higher count rates, the measured spectra were also in agreement with the ones calculated by the cascaded SRE+PPE model; with PMMA as attenuator, COV{sub W} was 5.6% at a DLR of 22% and as small as 6.7% for a DLR as high as 55%. Conclusions: The x-ray spectra calculated by the proposed model agreed with the measured spectra over a wide range of count rates and spectral shapes. The SRE model predicted the distorted, recorded spectra with low count rates over various types and thicknesses of attenuators. The study also validated the hypothesis that the complex spectral distortions in a PCD can be adequately modeled by cascading the count-rate independent SRE and the count-rate dependent PPE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-191: Automated Detection of Anatomic Changes in H'N Patients

Purpose: To develop a novel statistics-based method for automated detection of anatomical changes using cone-beam CT data. A method was developed that can provide a reliable and automated early warning system that enables a “just-in-time” adaptation of the treatment plan. Methods: Anatomical changes were evaluated by comparing the original treatment planning CT with daily CBCT images taken prior treatment delivery. The external body contour was computed on a given CT slice and compared against the corresponding contour on the daily CBCT. In contrast to threshold-based techniques, a statistical approach was employed to evaluate the difference between the contours using a given confidence level. The detection tool used the two-sample Kolmogorov-Smirnov test, which is a non-parametric technique that compares two samples drawn from arbitrary probability distributions. 11 H'N patients were retrospectively selected from a clinical imaging database with a total of 186 CBCT images. Six patients in the database were confirmed to have anatomic changes during the course of radiotherapy. Five of the H'N patients did not have significant changes. The KS test was applied to the contour data using a sliding window analysis. The confidence level of 0.99 was used to moderate false detection. Results: The algorithm was able to correctly detect anatomical changes in 6 out of 6 patients with an excellent spatial accuracy as early as at the 14th elapsed day. The algorithm provided a consistent and accurate delineation of the detected changes. The output of the anatomical change tool is easy interpretable, and can be shown overlaid on a 3D rendering of the patient's anatomy. Conclusion: The detection method provides the basis for one of the key components of Adaptive Radiation Therapy. The method uses tools that are readily available in the clinic, including daily CBCT imaging, and image co-registration facilities.

60 APPLIED LIFE SCIENCES↗