Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Data vs. MC Comparison of Light Signal from Cosmic Rays in the ICARUS Detectors

Currently, the ICARUS-T600 liquid argon TPC is collecting data exposed to Booster Neutrino and Numi off-axis beams within the SBN program at Fermilab. A light detection system, based on PMTs deployed behind the TPC wire chambers, is in place to detect vacuum ultraviolet photons produced by ionizing particles in LAr. This system is fundamental for the detector operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the TPC is exposed to a huge flux of cosmic rays due to its operations at shallow depths, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the beam spill gates. This contribution will primarily focus on the comparative study (data vs. MC) of light signal of cosmic muons to validate the light emulation.

43 PARTICLE ACCELERATORS↗

Measurement of the primary cosmic electron spectrum from 10 to about 250 GeV

The intensity and energy spectrum of primary cosmic electrons from 10 to about 250 GeV have been studied by using balloon-borne detectors. The detectors were large-area ionization calorimeters which sampled showering particles frequently and demonstrated an energy resolution of about 7% in calibration tests. On one of the flights a time-of-flight system and detectors to sample the lateral properties of showers were used to examine and to test background rejection. The results of the balloon flights from Alamogordo, N. Mex., in 1970 and Cape Girardeau, Mo., in 1972 indicated that the primary cosmic ray electron differential energy spectrum exhibits no change of slope in the energy range measured and is well represented by a power law. The results indicate that the cosmic electron spectrum is steeper than the cosmic ray proton spectrum. It is shown that these data are consistent with the leakage lifetime model for the propagation of cosmic electrons in the galaxy, although other more complex models cannot be excluded on the basis of these data.

Silverberg, R. F.↗

Light Meson Spectroscopy with GlueX and Beyond

The GlueX experiment at Jefferson Lab was specifically designed for precision studies of the light-meson spectrum. For this purpose, a photon beam with energies up to 12 GeV is directed onto a liquid hydrogen target contained within a hermetic detector with near-complete neutral and charged particle coverage. Linear polarization of the photon beam with a maximum around 9 GeV provides additional information about the production process. In 2018, the experiment completed its first phase, recording data with a total integrated luminosity above 400 pb?1. We highlight a selection of results from this world-leading data set with emphasis on the search for light hybrid mesons. In the mean time, the detector underwent significant upgrades and is currently recording data with an even higher luminosity. The future plans of the GlueX experiment to explore the meson spectrum with unprecedented precision are summarized.

Austregesilo, Alexander↗

Measurements of the inclusive and differential production cross sections of a top-quark–antiquark pair in association with a Z boson at $\sqrt{s}$ = 13 TeV with the ATLAS detector

Measurements of both the inclusive and differential production cross sections of a top-quark–antiquark pair in association with a Z boson ($t\bar{t}Z$) are presented. The measurements are performed by targeting final states with three or four isolated leptons (electrons or muons) and are based on $\sqrt{s}$=13 TeV proton–proton collision data with an integrated luminosity of 139 fb -1 , recorded from 2015 to 2018 with the ATLAS detector at the CERN Large Hadron Collider. The inclusive cross section is measured to be σ $t\bar{t}Z$ =0.99 ± 0.05 (stat.) ± 0.08 (syst.) pb, in agreement with the most precise theoretical predictions. The differential measurements are presented as a function of a number of kinematic variables which probe the kinematics of the $t\bar{t}Z$ system. Both absolute and normalised differential cross-section measurements are performed at particle and parton levels for specific fiducial volumes and are compared with theoretical predictions at different levels of precision, based on a χ 2 /ndf and p value computation. Overall, good agreement is observed between the unfolded data and the predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cross-field transport of less than 1 MeV protons in energetic particle events

A systematic analysis of hourly averaged low-energy anisotropy data (0.3-0.5 MeV) has been carried out with the JHU/APL detectors onboard the IMP-7 and 8 spacecraft from 1972-1975. The energetic particle events were divided into two major groups: flare-associated or nonimpulsive. Resolving the anistropy vectors into components parallel and perpendicular to the measured magnetic field leads directly to the following model-independent conclusions: (1) the average perpendicular anisotropy component is entirely accounted for in terms of the ExB drift, and hence transverse diffusion is negligible at these energies; application of the diffusion model to the nonimpulsive data set implies a ratio of the diffusion mean free paths parallel and perpendicular to the magnetic field much less than 0.051; (2) the parallel anisotropy component averages nearly to zero in the nonimpulsive data set, indicating virtually no net streaming along the field at 1 AU, averaged over all events.

Zwickl, R. D.↗

Development of thin-gap GEM- μ RWELL hybrid detectors

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview and first measurements of the MAST Upgrade bolometer diagnostic

Here, a suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

47 OTHER INSTRUMENTATION↗

JEDI-net: a jet identification algorithm based on interaction networks

Abstract We investigate the performance of a jet identification algorithm based on interaction networks (JEDI-net) to identify all-hadronic decays of high-momentum heavy particles produced at the LHC and distinguish them from ordinary jets originating from the hadronization of quarks and gluons. The jet dynamics are described as a set of one-to-one interactions between the jet constituents. Based on a representation learned from these interactions, the jet is associated to one of the considered categories. Unlike other architectures, the JEDI-net models achieve their performance without special handling of the sparse input jet representation, extensive pre-processing, particle ordering, or specific assumptions regarding the underlying detector geometry. The presented models give better results with less model parameters, offering interesting prospects for LHC applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron-antineutron oscillation search with MicroBooNE and DUNE

The Deep Underground Neutrino Experiment (DUNE) is an international project aiming at neutrino physics and astrophysics and a search for phenomena predicted by theories beyond the standard model (BSM). The excellent imaging capability of Liquid Argon Time Projection Chamber (LArTPC) technology, particle tracking and identification utilized in the Far Detector, as well as the Far Detector size and underground placement, allow the experiment to achieve high sensitivity to various rare processes. BSM theories predict the existence of baryon number non-conservation effects, in particular when the baryon number changes by 2. Here we discuss the sensitivity of DUNE to neutron-antineutron oscillation. With full event simulation and reconstruction using the LArSoft package, we have investigated the background to potential signal events from atmospheric neutrino interactions and particle misidentification, and utilized machine learning techniques to enhance the discrimination between signal and background. The methodologies being developed for a high-sensitivity search for neutron-antineutron oscillation in DUNE can also be demonstrated with the currently running MicroBooNE LArTPC. We discuss progress on demonstrating the developed techniques with the first-ever search for neutron-antineutron oscillation in a LArTPC using MicroBooNE data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Stochastic Calculus Approach to Boltzmann Transport

Traditional Monte Carlo methods for particle transport utilize source iteration to express the solution, the flux density, of the transport equation as a Neumann series. Our contribution is to show that the particle paths simulated within source iteration are associated with the adjoint flux density and the adjoint particle paths are associated with the flux density. Here, we make our assertion rigorous through the use of stochastic calculus by representing the particle path used in source iteration as a solution to a stochastic differential equation (SDE). The solution to the adjoint Boltzmann equation is then expressed in terms of the same SDE, and the solution to the Boltzmann equation is expressed in terms of the SDE associated with the adjoint particle process. An important consequence is that the particle paths used within source iteration simultaneously provide Monte Carlo samples of the flux density and adjoint flux density in the detector and source regions, respectively. The significant practical implication is that particle trajectories can be reused to obtain both forward and adjoint quantities of interest. To the best our knowledge, the reuse of entire particles paths has not appeared in the literature. Monte Carlo simulations are presented to support the reuse of the particle paths.

Boltzmann transport↗

Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3×3×57 mm3 and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to a most probable value (MPV) of energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IONS (ANURADHA): Ionization states of low energy cosmic rays

IONS (ANURADHA), the experimental payload designed specifically to determine the ionization states, flux, composition, energy spectra and arrival directions of low energy (10 to 100 MeV/amu) anomalous cosmic ray ions of helium to iron in near-Earth space, had a highly successful flight and operation Spacelab-3 mission. The experiment combines the accuracy of a highly sensitive CR-39 nuclear track detector with active components included in the payload to achieve the experimental objectives. Post-flight analysis of detector calibration pieces placed within the payload indicated no measurable changes in detector response due to its exposure in spacelab environment. Nuclear tracks produced by alpha-particles, oxygen group and Fe ions in low energy anomalous cosmic rays were identified. It is calculated that the main detector has recorded high quality events of about 10,000 alpha-particles and similar number of oxygen group and heavier ions of low energy cosmic rays.

Biswas, S.↗

Enhancing Neutrino Event Reconstruction with Pixel-Based 3D Readout for Liquid Argon Time Projection Chambers

In this paper we explore the potential improvements in neutrino event reconstruction that a 3D pixelated readout could offer over a 2D projective wire readout for liquid argon time projection chambers. We simulate and study events in two generic, idealized detector configurations for these two designs, classifying events in each sample with deep convolutional neural networks to compare the best 2D results to the best 3D results. In almost all cases we find that the 3D readout provides better reconstruction efficiency and purity than the 2D projective wire readout, with the advantages of 3D being particularly evident in more complex topologies, such as electron neutrino charged current events. We conclude that the use of a 3D pixelated detector could significantly enhance the reach and impact of future liquid argon TPC experiments physics program, such as DUNE.

Adams, C↗

Virtual Slit Cycloidal Mass Spectrometry for Isotopic Measurements of Actinide Particles

The Virtual Slit Cycloidal Mass Spectrometer is a unique instrument for analysis of particles with mass spectrometry. It combines the unique properties of the cycloidal mass analyzer with capacitive transimpedance amplifier array detectors to make a portable instrument potentially capable of high sensitivity measurements on single particles, including high precision isotope ratios.

47 OTHER INSTRUMENTATION↗