Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Aortic Branch Artery Pseudoaneurysms Associated with Intramural Hematoma: When and How to Do Endovascular Embolization

To describe when and how to perform endovascular embolization of aortic branch artery pseudoaneurysms associated with type A and type B intramural hematoma (IMH) involving the descending thoracic and abdominal aorta (DeBakey I and III) that increased significantly in size during follow-up. Sixty-one patients (39 men; mean {+-} standard deviation age 66.1 {+-} 11.2 years) with acute IMH undergoing at least two multidetector computed tomographic examinations during follow-up for 12 months or longer were enrolled. Overall, 48 patients (31 men, age 65.9 {+-} 11.5) had type A and type B IMH involving the descending thoracic and abdominal aorta (DeBakey I and III). Among the 48 patients, 26 (54 %; 17 men, aged 64.3 {+-} 11.4 years) had 71 aortic branch artery pseudoaneurysms. Overall, during a mean follow-up of 22.1 {+-} 9.5 months (range 12-42 months), 31 (44 %) pseudoaneurysms disappeared; 22 (31 %) decreased in size; two (3 %) remained stable; and 16 (22 %) increased in size. Among the 16 pseudoaneurysms with increasing size, five of these (three intercostal arteries, one combined intercostobronchial/intercostal arteries, one renal artery), present in five symptomatic patients, had a significant increase in size (thickness >10 mm; width and length >20 mm). These five patients underwent endovascular embolization with coils and/or Amplatzer Vascular Plug. In all patients, complete thrombosis and exclusion of aortic pseudoaneurysm and relief of back pain were achieved. Aortic branch artery pseudoaneurysms associated with type A and type B IMH involving the descending thoracic and abdominal aorta (DeBakey I and III) may be considered relatively benign lesions. However, a small number may grow in size or extend longitudinally with clinical symptoms during follow-up, and in these cases, endovascular embolization can be an effective and safe procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Two Pseudoaneurysms Originating From the Left Ventricle

A 67-year-old woman resented with an acute type A aortic dissection, which was treated surgically with aortic valve replacement as a composite graft with reimplantation of the coronary arteries. At the end of surgery, a left-ventricular venting catheter was placed through the apex and closed with a buffered suture. Consecutive computed tomography (CT) examinations verified a growing apex pseudoaneurysm. Communication between the ventricle and the pseudoaneurysm was successfully closed with an Amplatz septal plug by the transfemoral route. Follow-up CT showed an additional pseudoaneurysm, which also was successfully closed using the same method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of an Aneurysmal Aberrant Systemic Artery Supplying a Pulmonary Sequestrum

An aberrant systemic artery originating from the abdominal aorta supplying a pulmonary sequestration is a rare congenital malformation. This causes a left-to-left shunt. Symptoms include recurrent pneumonias, hemoptysis, and, in the long term, heart failure. Aneurysm of the aberrant vessel is rarely seen. Traditionally, treatment of pulmonary sequestrations includes ligation of the feeding vessel and lobectomy. A new promising treatment is an endovascular approach. Only a few cases describe endovascular treatment of pulmonary sequestration. This is the first published case of a giant aneurysmal branch from the abdominal aorta to the normal basal segments of the lung, successfully occluded with an Amplatzer Vascular Plug II (AVP II, St.Jude Medical, MN, USA) alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Embolization of Anomalous Systemic Arterial Supply to Normal Basal Segments of the Lung

PurposeTo evaluate transarterial embolization (TAE) for the management of anomalous systemic arterial (ASA) supply to normal basal segments of the lung.MethodsThirteen patients with ASA supply to normal basal segments of the lung underwent TAE. All patients presented with hemoptysis and had complete-type anomalies on pre-TAE or post-TAE computed tomography (CT). The anomaly was unilateral in all patients; 11 lesions were located in the left lung and 2 in the right. All patients underwent embolization with coils (n = 10) or a vascular plug (n = 3). Procedural success, clinical efficacy, and complications were assessed. Mean post-TAE CT and clinical follow-up was 25.4 and 42.1 months, respectively.ResultsTechnical success was achieved in 100 % of cases. Several changes were noted on follow-up CT: complete obstruction of the ASA in all cases, normal (n = 11) or decreased (n = 2) density of the affected lung parenchyma, reduction of the primary enlarged inferior pulmonary vein in all cases, and pulmonary infarction and thickening of the corresponding bronchial artery (n = 4). The main complication was pulmonary infarction in four cases.ConclusionTAE is a safe, effective, and minimally invasive therapeutic option for patients with ASA supply to normal basal segments of the lung.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Injection of Blood Products Versus Gelatin Sponge as a Technique for Local Hemostasis

PurposeTo provide a method of reducing risk of minimally invasive procedures on patients with abnormal hemostasis and evaluate efficacy of direct fresh frozen plasma injection through a procedure needle tract compared to Gelfoam (gelatin sponge) administration.Materials and MethodsEighty patients with elevated international standardized ratio (INR) undergoing minimally invasive procedures using imaging guidance were selected retrospectively. Forty patients had received Gelfoam as a means of tract embolization during the procedure. The other 40 received local fresh frozen plasma (FFP) through the needle tract. The number of complications and clinically significant bleeding events were recorded. A threshold of 30 cc of blood loss after a procedure was used to identify excess bleeding.ResultsNo patients experienced clinically significant bleeding after administration of FFP. Five patients experienced postoperative drops in hemoglobin or hematomas after administration of Gelfoam.ConclusionLocal injection of blood products can reduce postprocedure bleeding in patients undergoing minimally invasive procedures and provides a safe alternative to the use of synthetic fibrin plugs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Closure Devices for Iatrogenic Thoraco-Cervical Vascular Injuries

IntroductionThe unintentional arterial placement of a central venous line can have catastrophic complications. The purpose of this systematic review is to assess and analyse the available evidence regarding the use of the various vascular closure devices (VCDs) for the management of iatrogenic thoraco-cervical arterial injuries (ITCAI).MethodsA systematic review was performed according to PRISMA guidelines.ResultsThirty-two relevant case series and case reports were identified with a total of 69 patients having being studied. In the majority of the studies, plug-based VCDs were used (81%) followed by suture-based devices (19%). The majority of studies reported successful outcomes from the use of VCDs in terms of achieving immediate haemostasis without any acute complications. Long-term follow-up data were only available in nine studies with only one case of carotid pseudoaneurysm being reported after 1-month post-procedure. All other cases had no reported long-term complications. Five studies performed direct or indirect comparisons between VCDs and other treatments (open surgery or stent grafting) suggesting no significant differences in safety or effectiveness.ConclusionAlthough there is limited evidence, VCDs appear to be safe and effective for the management of ITCAIs. Further research is warranted regarding the effectiveness of this approach in comparison to surgery and in order to identify those patients who are more likely to benefit from this minimally invasive approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Approach, Technical Success, Complications, and Stent Patency of Sharp Recanalization for the Treatment of Chronic Venous Occlusive Disease: Experience in 123 Patients

Purpose: To report the technical success and complications following sharp recanalization of chronic venous occlusions. Materials and Methods: A total of 123 patients, including 75 (61.0%) men and 48 (39.0%) women, with mean age of 50.5 ± 17.5 years (range 19–90 years), underwent sharp recanalization of chronic venous occlusions. The etiologies of occlusion were chronic deep venous thrombosis (n = 43; 35.0%), prior central venous access (n = 39; 31.7%), indwelling cardiac leads (n = 21; 17.1%), and occluded venous stents (n = 20; 16.3%). The sites of venous occlusion included 59/123 (48.0%) thoracic central veins, 37 (30.1%) non-thoracic central veins, and 27 (22.0%) peripheral veins. Median length of occlusion was 3.2 ± 1.4 cm (range 1.3–10.9 cm). Results: Sharp recanalization was most commonly attempted with transseptal needles in 108/123 (87.8%), with a mean number of 1.2 ± 0.4 crossing devices per patient (range 1–4 devices). Targeting devices included a loop snare (n = 92; 74.8%), partially deployed Wallstent (n = 21; 17.1%), partially deployed Amplatzer vascular plug (n = 8; 6.5%), and an angioplasty balloon (n = 3; 2.4%). Technical success was achieved in 111 (90.2%) patients. There were 3 (2.4%) severe, 1 (0.8%) moderate, and 7 (5.7%) minor adverse events. Severe adverse events included 1 case each of pericardial tamponade, hemothorax, and inferior vena cava filter occlusion. 88 (71.5%) patients had venous stents placed; at the last follow-up examination, 68/86 (79.0%) stents were patent. Conclusion: Sharp recanalization has a high technical success and low rate of adverse events in the recanalization of chronic venous occlusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Bifurcated Covered Self-Expanding Metallic Stents for Complex Tracheobronchial Fistulas or Stenosis

Objective: We aimed to determine the safety and feasibility of bifurcated covered self-expanding stents for the treatment of complex tracheobronchial fistulas or stenosis. Methods: Twenty-eight patients were treated by multiple bifurcated covered airway stents (Micro-Tech Co. Ltd., Nanjing, China), including 18 cases of gastrobronchial or gastrotracheal fistula, 6 cases of bronchopleural fistula and 4 cases of severe tracheobronchial stenosis. The large bifurcated covered stent was placed at the main carina, and the small stents were inserted into primary right carina or secondary left carina. Clinical and imaging data were retrospectively analyzed. Results: Stents were successfully inserted in 27 patients at the first attempt. In total, 29 large bifurcated covered stents, 27 small bifurcated covered stents and 5 small bifurcated covered single-plugged stents were inserted. All patients with fistula could resume eating without coughing after the procedure. No perioperative death or severe complications occurred. Two patients underwent stent removal due to intolerance of stenting; the clinical success rate was 93% (26/28). Nineteen complications were found in 12 patients; 8 patients needed stent removal or replacement, for a major complication rate of 29% (8/28). Eight patients underwent successful stent removal due to complications. Fifteen patients died of tumors and one patient died of pulmonary infection. The median survival was 33 months. Fistula recurrence was found in one patient 5 months after stenting, and second small bifurcated covered stent was inserted. Conclusions: Multiple bifurcated covered metallic stenting is effective and safe for complex tracheobronchial fistulas or stenosis, with good symptom palliation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Bronchial Embolization to Treat Intractable Bronchobiliary Fistula

Sixty-four-year-old female who underwent hemi-hepatectomy for intrahepatic cholangiocarcinoma a year ago presented with biliary sputum, cough and fever. Cross-sectional imaging showed a recurred tumor involving right diaphragmatic area and an abscess formation in liver dome with adjacent right lower lobe of lung. Percutaneous transhepatic biliary drainage and percutaneous drainage of lung abscess were performed. Tubogram showed connections between the lung abscess cavity and multiple distal bronchi, suggesting bronchobiliary fistulas. Two weeks of drainage treatment did not relieve symptoms. We successfully treated intractable bronchobiliary fistula via image-guided percutaneous access to closest distal bronchi near abscess with subsequent tandem placement of vascular plugs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Post-Biopsy Manoeuvres to Reduce Pneumothorax Incidence in CT-Guided Transthoracic Lung Biopsies: A Systematic Review and Meta-analysis

This systematic review and meta-analysis investigated post-biopsy manoeuvres to reduce pneumothorax following computed tomography-guided percutaneous transthoracic lung biopsy. Twenty-one articles were included with 7080 patients. Chest drain insertion rates were significantly reduced by ninefold with the normal saline tract sealant compared to controls (OR 0.11, 95% CI 0.02–0.48), threefold with the rapid rollover manoeuvre to puncture site down (OR 0.34, 95% CI 0.18–0.63), threefold with the tract plug (OR 0.33, 95% CI 0.22–0.48) and threefold with the blood patch (OR 0.39, 95% CI 0.26–0.58). The absolute chest drain insertion rates were the lowest in the normal saline tract sealant (0.8% vs 7.3% for controls), rapid rollover (1.9% vs 5.2%), deep expiration and breath-hold on needle extraction (0.9% vs 1.8%) and standard rollover versus no rollover (2.6% vs 5.2%). These findings highlight post-biopsy manoeuvres which could help reduce pneumothorax and chest drain insertions following lung biopsies. Level of Evidence: Level 1/no level of evidence, systematic review.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a fluvial aquifer at a range of depths and scales: the Triassic St Bees Sandstone Formation, Cumbria, UK

Fluvial sedimentary successions represent porous media that host groundwater and geothermal resources. Additionally, they overlie crystalline rocks hosting nuclear waste repositories in rift settings. The permeability characteristics of an arenaceous fluvial succession, the Triassic St Bees Sandstone Formation in England (UK), are described, from core-plug to well-test scale up to ~1 km depth. Within such lithified successions, dissolution associated with the circulation of meteoric water results in increased permeability (K~10{sup −1}–10{sup 0} m/day) to depths of at least 150 m below ground level (BGL) in aquifer systems that are subject to rapid groundwater circulation. Thus, contaminant transport is likely to occur at relatively high rates. In a deeper investigation (> 150 m depth), where the aquifer has not been subjected to rapid groundwater circulation, well-test-scale hydraulic conductivity is lower, decreasing from K~10{sup −2} m/day at 150–400 m BGL to 10{sup −3} m/day down-dip at ~1 km BGL, where the pore fluid is hypersaline. Here, pore-scale permeability becomes progressively dominant with increasing lithostatic load. Notably, this work investigates a sandstone aquifer of fluvial origin at investigation depths consistent with highly enthalpy geothermal reservoirs (~0.7–1.1 km). At such depths, intergranular flow dominates in unfaulted areas with only minor contribution by bedding plane fractures. However, extensional faults represent preferential flow pathways, due to presence of high connective open fractures. Therefore, such faults may (1) drive nuclear waste contaminants towards the highly permeable shallow (< 150 m BGL) zone of the aquifer, and (2) influence fluid recovery in geothermal fields.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3D Histopathology—a Lung Tissue Segmentation Workflow for Microfocus X-ray-Computed Tomography Scans

Lung histopathology is currently based on the analysis of 2D sections of tissue samples. The use of microfocus X-ray-computed tomography imaging of unstained soft tissue can provide high-resolution 3D image datasets in the range of 2–10 μm without affecting the current diagnostic workflow. Important details of structural features such as the tubular networks of airways and blood vessels are contained in these datasets but are difficult and time-consuming to identify by manual image segmentation. Providing 3D structures permits a better understanding of tissue functions and structural interrelationships. It also provides a more complete picture of heterogeneous samples. In addition, 3D analysis of tissue structure provides the potential for an entirely new level of quantitative measurements of this structure that have previously been based only on extrapolation from 2D sections. In this paper, a workflow for segmenting such 3D images semi-automatically has been created using and extending the ImageJ open-source software and key steps of the workflow have been integrated into a new ImageJ plug-in called LungJ. Results indicate an improved workflow with a modular organization of steps facilitating the optimization for different sample and scan properties with expert input as required. This allows for incremental and independent optimization of algorithms leading to faster segmentation. Representation of the tubular networks in samples of human lung, building on those segmentations, has been demonstrated using this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monitoring the Presence and Location of Metallic Components Inside a Fuel Element

A non-destructive method of monitoring the presence and location of metallic components in a fuel element is proposed. It is shown that a nickel plug can be identified by modernizing the measurement procedure. A method of performing measurements is described and the results of experimental studies are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

In-Process Measurements of Flow Characteristics of Wood Plastic Composites

The flow characteristics of polypropylene filled with high percentages of wood flour (50 and 70 wt%) are investigated at a feasible processing temperature (195 °C). Rotational rheometry in oscillatory mode in conjunction with the Cox–Merz rule is ineffective at this temperature due to insufficient linear viscoelastic region (LVR) size and ease of fibres degradation. An in-line rheometer, directly attached to a single screw extruder, is used to avoid these problems: this method allows measurements in real processing conditions with no LVR issues and with reduced degradation risks. The 70 wt% displays plug flow, thus it has been impossible to obtain the flow curve but only the slip velocity as a function of shear stress. The 50 wt% could be corrected for slip using the Mooney procedure. Comparing the flow curve of this material with the ones of the 30 wt% and the unfilled polypropylene matrix, a single master-curve can be obtained and modelled with a Carreau–Yasuda equation.

36 MATERIALS SCIENCE↗

Fabrication and Radio Frequency Properties of 3-GHz SRF Cavities Coated with MgB 2

Magnesium diboride (MgB 2 ) is considered a potential material for superconducting radio frequency cavities. MgB 2 coated Cu cavity will allow for a higher operational temperature than a bulk Nb cavity because of the higher transition temperature of MgB 2 and the high thermal conductivity of Cu. Using the hybrid physical chemical vapor deposition technique, MgB 2 coatings were successfully achieved on the inner wall of 3-GHz Cu cavities. The surface and superconducting properties of the coatings were characterized using small samples on Cu plugs mounted at different locations of mock cavities. RF measurement of a MgB 2 coated single-cell 3-GHz test cavity was carried out and it showed superconducting transition at 36 K. Here, the quality factor of this test cavity was lower than expected due to poor connectivity and inclusion of Mg-Cu alloy in the MgB 2 coating.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Intensity and daily pattern of passenger vehicle use by region and class in China: estimation and implications for energy use and electrification

Given the explosive growth of the passenger vehicle market and energy demands in China, research on vehicle-use intensity and driver-travel patterns is critical for better assessing travel demand and its implications for alternative fuel vehicles, energy security, and environmental policies. This study attempts to estimate annual vehicle kilometers traveled (AVKT) per privately-owned passenger vehicle and their daily distance patterns by vehicle class and geographic region. The data sample from a survey consists of 169,292 privately owned passenger vehicles, made by 177 car manufacturers during 2003–2018, running in 82 cities from 27 provincial regions. The log-transformed average AVKT is estimated to be 12,377 km with 95% probability ranging from 5490 to 28,579 km. The investigation reveals that vehicles from South China have the highest AVKT at 13,320 km. Generally, vehicles in small cities have higher AVKT than in big cities, except AVKT of tier 1 cities being higher. Another trend is that more expensive or larger vehicles tend to be driven more. A model is fitted for estimating AVKT based on region, city type, automaker, price range, and certain vehicle features including class and age. Data of daily commuting distances in recent years are also analyzed. The average daily commuting distances typically range from 21 to 28 km. Using the validated Gamma distribution method, daily distance distributions are specified for different regions. It is found that 99% of the daily driving distance is no more than 88.0–112.0 km, depending on region. Utility factors of plug-in electric vehicles are also estimated to be much higher than those based on driving data in the USA. Finally, these findings suggest global mitigations strategies on vehicle fuel use, electrification, and greenhouse gases should consider vehicle-use intensity at the regional level.

33 ADVANCED PROPULSION SYSTEMS↗

Reaction Pathways and Energy Consumption in NH 3 Decomposition for H 2 Production by Low Temperature, Atmospheric Pressure Plasma

Pathways for NH 3 decomposition to N 2 and N 2 H 4 by atmospheric pressure nonthermal plasma are analyzed using a combination of molecular beam mass spectrometry measurements and zero-dimensional kinetic modeling. Experimental measurements show that NH 3 conversion and selectivity towards N 2 formation scale monotonically with the specific energy input into the plasma with ~ 100% selectivity to N 2 formation achieved at specific energy inputs above 0.12 J cm −3 (3.1 eV (molecule NH 3 ) −1 ). The kinetic model recovers these trends, although it underpredicts N 2 selectivity at low specific energy input. These discrepancies can be explained by the underestimation of reaction rate coefficients for reactions that consume N 2 H x species in collisions with H radicals and/or radial nonuniformities in power deposition, gas temperature, and species concentrations that are not represented by the plug flow approximation used in the model. The kinetic model shows that N 2 formation proceeds through N 2 H x decomposition pathways rather than NH x decomposition pathways in low temperature, atmospheric pressure plasma. Higher selectivity toward N 2 production can be achieved by operating at higher NH 3 conversion and with a higher gas temperature. Furthermore, the high energy cost of NH 3 decomposition by atmospheric pressure nonthermal plasma found in this work (25–50 eV (molecule NH 3 converted) −1 ; 17–33 eV (molecule H 2 formed) −1 ) is a result of the energy requirement for electron-impact dissociation of NH 3 and the significant re-formation of NH 3 by three-body recombination reactions between NH 2 and H.

Nonthermal plasma↗

The effective number of parameters in kernel density estimation

We devise a new formula for measuring the effective degrees of freedom (EDoF) in kernel density estimation (KDE). Starting from the orthogonal polynomial sequence (OPS) expansion for the ratio of the empirical to the oracle density, we show how convolution with the kernel leads to a new OPS with respect to which one may express the resulting KDE. The expansion coefficients of the two OPS systems can then be related via a kernel sensitivity matrix, which leads to a natural oracle definition of EDoF through the trace operator. Asymptotic properties of the (empirical) plug-in EDoF are worked out through influence functions, and connections with other empirical EDoFs are established. Minimization of Kullback-Leibler divergence is investigated as an alternative to integrated squared error based bandwidth selection rules, yielding a new normal scale rule. The methodology, which arises from a proper oracle formulation and is not restricted to convolution kernels, suggests the possibility of a new bandwidth selection rule based on an information criterion such as AIC.

bandwidth selection↗