Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Sustainability principles in strategic environmental assessment: A framework for analysis and examples from Italian urban planning

This paper presents a framework for analysing the degree of consideration of sustainability principles in Strategic environmental assessment (SEA), and demonstrates its application to a sample of SEA of Italian urban plans. The framework is based on Gibson's (2006) sustainability principles, which are linked to a number of guidance criteria and eventually to review questions, resulting from an extensive literature review. A total of 71 questions are included in the framework, which gives particular emphasis to key concepts, such as intragenerational and intergenerational equity. The framework was applied to review the Environmental Report of the urban plans of 15 major Italian cities. The results of this review show that, even if sustainability is commonly considered as a pivotal concept, there is still work to be done in order to effectively integrate sustainability principles into SEA. In particular, most of the attention is given to mitigation and compensation measures, rather than to actual attempts to propose more sustainable planning decisions in the first place. Concerning the proposed framework of analysis, further research is required to clarify equity concerns and particularly to identify suitable indicators for operationalizing the concepts of intra/inter-generational equity in decision-making. -- Highlights: ► A framework was developed in order to evaluate planning against sustainability criteria. ► The framework was applied to analyse how sustainable principles are addressed in 15 Italian SEA reports. ► Over 85% of the reports addressed, to some extent, at least 40% of the framework questions. ► Criteria explicitly linked to intra and inter-generational equity are rarely addressed.

54 ENVIRONMENTAL SCIENCES↗

Applying an improved rapid impact assessment matrix method to strategic environmental assessment of urban planning in China

Strategic environmental assessment (SEA) has become an increasingly important decision-support tool for providing information on the environmental implications of a policy, plan, or program. The goal is to safeguard the environment and promote sustainable development at the strategic level. Despite major progress in implementing SEA practices internationally, developing countries, such as China, often lag behind in applying SEA methodology. Lack of available data and time constraints arising from tight schedules create problems. The rapid impact assessment matrix (RIAM) is a potential resource for breaking through such difficulties. Our analysis of RIAM applications suggested that it could become a tool for evaluating strategic alternatives because of its applicability in interdisciplinary settings, its transparency, and its short implementation timeframe. To make it more suitable for the SEA context, we have developed two major improvements to the conventional RIAM process: assignment of weights to assessment indicators and the development of an integrated environmental assessment score (IES). The improved RIAM process was employed in an SEA of the development plan for the Nansha District in Guangzhou, the capital city of Guangdong Province in China. It was used to assess five alternatives for development in Wanqingsha (WQS), a subunit of Nansha, where important ecological resources are located and where industrial development could impact the air quality in the neighboring Hong Kong Special Administrative Region (HKSAR). The evaluation identified WQS-A04 as the preferred alternative. This alternative involved a minimal amount of industrial development – 10% compared with the most intense development alternative – and included important wetland preservation plans. The assessment results have been incorporated into the officially approved development plan for Nansha. The improved RIAM methodology is well adapted to the technical aims of SEA and decision-making structures in China. It offers the potential for delivering timely and quality results to decision-making processes. To achieve the desired efficiency, it is recommended that an SEA procedure take into account findings acquired from an improved RIAM application at an early stage, then, at a later stage, results from more comprehensive assessments conducted using more sophisticated methods should be added, if time and data are available. - Highlights: • RIAM is a potential SEA tool due to its multidisciplinary setting and rapid process. • Weighting index and computing IES are raised for improving RIAM when applied to SEAs. • The improved RIAM boosts SEA effectiveness by timely responding to decision-making. • The improved RIAM is more suitable to an SEA bothered by tight time or data shortage. • The improved RIAM adapts to the technical aims of SEA and decision features in China.

54 ENVIRONMENTAL SCIENCES↗

A Framework to Support the Fusion of Operation and Planning

The management of the nation’s power system has progressed to the point where the boundary lines between operations and planning are becoming blurred. The dynamic behavior of smart grid technologies brings pressures of incorporating the predictive capability from planning to enhance operations. These needs are requiring a smoother, better integrated interplay between the functional roles of planning and operations. This paper presents a framework to support the fusion of operation and planning. A case study of predicting the intra-hour deficiency in generation capability and ramping capacity and presenting the outputs to operators was conducted. The study shows the benefits of the fusion and the effectiveness of the framework. All the function blocks used in the study were built upon GridOPTICS Software System (GOSS), a software system middleware platform that facilitates deployment of new applications for the future power grid.

Framework↗

Transmission-distribution long-term volt-var planning considering reactive power support capability of distributed PV

High penetration of grid-edge, inverter-based photovoltaic (PV) can cause significant voltage fluctuations not only at the distribution but also at the sub-transmission levels due to PV output intermittency. Traditional reactive power planning approaches do not consider intermittency, nor the possibility of coordinating the control of existing and future volt-ampere reactive resources. This paper proposes a reactive power planning tool for sub-transmission systems to mitigate voltage violations and fluctuations caused by high PV penetration and intermittency with a minimum investment cost. The planning tool coordinates with an optimization-based volt-var operational tool for: a) modeling the coordination of all existing var assets in both sub-transmission and distribution systems to reduce the need of new equipment, and b)selecting a set of scenarios with voltage violations, derived from PV intermittency c) testing the final investment decision. The tool obtains an investment need for each intermittency scenario with a proposed optimal power-flow framework with efficient techniques to handle a high number of discrete variables. Two options are provided for final planning decision: i) a conservative direct combination of investment need solutions and ii) a machine learning-based selection of representative investment needs at most time steps. The final investment decision options are verified using a realistic large-scale sub-transmission system and 5-minute PV and load data. The results show a significant voltage performance improvement with a lower investment cost for additional var equipment compared to conventional approaches.

14 SOLAR ENERGY↗

Adaptive Radiotherapy Planning on Decreasing Gross Tumor Volumes as Seen on Megavoltage Computed Tomography Images

Purpose: To evaluate gross tumor volume (GTV) changes for patients with non-small-cell lung cancer by using daily megavoltage (MV) computed tomography (CT) studies acquired before each treatment fraction on helical tomotherapy and to relate the potential benefit of adaptive image-guided radiotherapy to changes in GTV. Methods and Materials: Seventeen patients were prescribed 30 fractions of radiotherapy on helical tomotherapy for non-small-cell lung cancer at London Regional Cancer Program from Dec 2005 to March 2007. The GTV was contoured on the daily MVCT studies of each patient. Adapted plans were created using merged MVCT-kilovoltage CT image sets to investigate the advantages of replanning for patients with differing GTV regression characteristics. Results: Average GTV change observed over 30 fractions was -38%, ranging from -12 to -87%. No significant correlation was observed between GTV change and patient's physical or tumor features. Patterns of GTV changes in the 17 patients could be divided broadly into three groups with distinctive potential for benefit from adaptive planning. Conclusions: Changes in GTV are difficult to predict quantitatively based on patient or tumor characteristics. If changes occur, there are points in time during the treatment course when it may be appropriate to adapt the plan to improve sparing of normal tissues. If GTV decreases by greater than 30% at any point in the first 20 fractions of treatment, adaptive planning is appropriate to further improve the therapeutic ratio.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can Positron Emission Tomography (PET) or PET/Computed Tomography (CT) Acquired in a Nontreatment Position Be Accurately Registered to a Head-and-Neck Radiotherapy Planning CT?

Purpose: To quantify the uncertainties associated with incorporating diagnostic positron emission tomography/CT (PET/CT) and PET into the radiotherapy treatment-planning process using different image registration tools, including automated and manual rigid body registration methods, as well as deformable image registration. Methods and Materials: The PET/CTs and treatment-planning CTs from 12 patients were used to evaluate image registration accuracy. The PET/CTs also were used without the contemporaneously acquired CTs to evaluate the registration accuracy of stand-alone PET. Registration accuracy for relevant normal structures was quantified using an overlap index and differences in the center of mass (COM) positions. For tumor volumes, the registration accuracy was measured using COM positions only. Results: Registration accuracy was better with PET/CT than with PET alone. The COM displacements ranged from 3.2 {+-} 0.6 mm (mean {+-} 95% confidence interval, for brain) to 8.4 {+-} 2.6 mm (spinal cord) for registration with PET/CT data, compared with 4.8 {+-} 1.7 mm (brain) and 9.9 {+-} 3.1 mm (spinal cord) with PET alone. Deformable registration improved accuracy, with minimum and maximum errors of 1.1 {+-} 0.8 mm (brain) and 5.4 {+-} 1.4 mm (mandible), respectively. Conclusions: It is possible to incorporate PET and/or PET/CT acquired in diagnostic positions into the treatment-planning process through the use of advanced image registration algorithms, but precautions must be taken, particularly when delineating tumor volumes in the neck. Acquisition of PET/CT in the treatment-planning position would be the ideal method to minimize registration errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generic Planning Target Margin for Rectal Cancer Treatment Setup Variation

Purpose: To calculate the generic planning target margin (GPTM) for patients receiving radiation therapy (RT) for rectal cancer placed in a prone position with a customized cradle for small-bowel exclusion. Methods and Materials: A total of 25 consecutive rectal cancer patients were treated for 25 or 28 fractions in a prone position using a cradle to maximize small bowel exclusion. Treatment planning computed tomography (CT) scans were used to create orthogonally digitally reconstructed radiographs (DRRs) for portal image registration, which were compared with daily portal images from an electronic portal-imaging device (EPID). Translation values needed to align the DRRs and EPIDs were recorded for the superior to inferior (SI), right to left (RL), and anterior to posterior (AP) directions, and used to calculate the GPTM using the four-parameter model. Age, weight, and body mass index were tested compared with the setup variation using a Pearson correlation and a t test for significance. Gender versus setup variation was compared with a t test. Results: A total of 1,723 EPID images were reviewed. The GPTM was 10 mm superior, 8 mm inferior, 7 mm RL and 10 mm AP. Age and gender were unrelated to setup variation. Weight was significantly associated with systematic AP variation (p < 0.05). BMI was significantly associated with systematic SI (p < 0.05) and AP (p < 0.01) variation and random RL variation (p < 0.05). Conclusions: The GPTM for rectal cancer is asymmetric with a maximum of 10 mm in the superior, anterior and posterior dimensions. Body mass index may effect setup variation. Research using advanced treatment planning should include these margins in the planning target volume definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose Rate Brachytherapy Using Inverse Planning Simulated Annealing for Locoregionally Advanced Cervical Cancer: A Clinical Report With 2-Year Follow-Up

Purpose: We present clinical outcomes of image-guided brachytherapy using inverse planning simulated annealing (IPSA) planned high-dose rate (HDR) brachytherapy boost for locoregionally advanced cervical cancer. Methods and Materials: From February 2004 through December 2006, 51 patients were treated at the University of California, San Francisco with HDR brachytherapy boost as part of definitive radiation for International Federation of Gynecology and Obstetrics Stage IB1 to Stage IVA cervical cancer. Of the patients, 46 received concurrent chemotherapy, 43 with cisplatin alone and 3 with cisplatin/5-fluorouracil. All patients had IPSA-planned HDR brachytherapy boost after whole-pelvis external radiation to a total tumor dose of 85 Gy or greater (for alpha/beta = 10). Toxicities are reported according to National Cancer Institute CTCAE v3.0 (Common Terminology Criteria for Adverse Events version 3.0) guidelines. Results: At a median follow-up of 24.3 months, there were no toxicities of Grade 4 or greater and the frequencies of Grade 3 acute and late toxicities were 4% and 2%, respectively. The proportion of patients having Grade 1 or 2 gastrointestinal and genitourinary acute toxicities was 48% and 52%, respectively. Low-grade late toxicities included Grade 1 or 2 vaginal, gastrointestinal, and hormonal toxicities in 31%, 18%, and 4% of patients, respectively. During the follow-up period, local recurrence developed in 2 patients, regional recurrence developed in 2, and new distant metastases developed in 15. The rates of locoregional control of disease and overall survival at 24 months were 91% and 86%, respectively. Conclusions: Definitive radiation by use of inverse planned HDR brachytherapy boost for locoregionally advanced cervical cancer is well tolerated and achieves excellent local control of disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of [{sup 11}C]Methionine Positron Emission Tomography for Target Definition of Glioblastoma Multiforme in Radiation Therapy Planning

Purpose: The purpose of this work was to define the optimal margins for gadolinium-enhanced T{sub 1}-weighted magnetic resonance imaging (Gd-MRI) and T{sub 2}-weighted MRI (T{sub 2}-MRI) for delineating target volumes in planning radiation therapy for postoperative patients with newly diagnosed glioblastoma multiforme (GBM) by comparison to carbon-11-labeled methionine positron emission tomography ([{sup 11}C]MET-PET) findings. Methods and Materials: Computed tomography (CT), MRI, and [{sup 11}C]MET-PET were separately performed for radiation therapy planning for 32 patients newly diagnosed with GBM within 2 weeks after undergoing surgery. The extent of Gd-MRI (Gd-enhanced clinical target volume [CTV-Gd]) uptake and that of T{sub 2}-MRI of the CTV (CTV-T{sub 2}) were compared with the extent of [{sup 11}C]MET-PET (CTV--[{sup 11}C]MET-PET) uptake by using CT--MRI or CT--[{sup 11}C]MET-PET fusion imaging. We defined CTV-Gd (x mm) and CTV-T{sub 2} (x mm) as the x-mm margins (where x = 0, 2, 5, 10, and 20 mm) outside the CTV-Gd and the CTV-T{sub 2}, respectively. We evaluated the relationship between CTV-Gd (x mm) and CTV-- [{sup 11}C]MET-PET and the relationship between CTV-T{sub 2} (x mm) and CTV-- [{sup 11}C]MET-PET. Results: The sensitivity of CTV-Gd (20 mm) (86.4%) was significantly higher than that of the other CTV-Gd. The sensitivity of CTV-T{sub 2} (20 mm) (96.4%) was significantly higher than that of the other CTV-T{sub 2} (x = 0, 2, 5, 10 mm). The highest sensitivity and lowest specificity was found with CTV-T{sub 2} (x = 20 mm). Conclusions: It is necessary to use a margin of at least 2 cm for CTV-T{sub 2} for the initial target planning of radiation therapy. However, there is a limit to this setting in defining the optimal margin for Gd-MRI and T{sub 2}-MRI for the precise delineation of target volumes in radiation therapy planning for postoperative patients with GBM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase II Comparative Study of Gross Tumor Volume Definition With or Without PET/CT Fusion in Dosimetric Planning for Non-Small-Cell Lung Cancer (NSCLC): Primary Analysis of Radiation Therapy Oncology Group (RTOG) 0515

Background: Radiation Therapy Oncology Group (RTOG) 0515 is a Phase II prospective trial designed to quantify the impact of positron emission tomography (PET)/computed tomography (CT) compared with CT alone on radiation treatment plans (RTPs) and to determine the rate of elective nodal failure for PET/CT-derived volumes. Methods: Each enrolled patient underwent definitive radiation therapy for non-small-cell lung cancer ({>=}60 Gy) and had two RTP datasets generated: gross tumor volume (GTV) derived with CT alone and with PET/CT. Patients received treatment using the PET/CT-derived plan. The primary end point, the impact of PET/CT fusion on treatment plans was measured by differences of the following variables for each patient: GTV, number of involved nodes, nodal station, mean lung dose (MLD), volume of lung exceeding 20 Gy (V20), and mean esophageal dose (MED). Regional failure rate was a secondary end point. The nonparametric Wilcoxon matched-pairs signed-ranks test was used with Bonferroni adjustment for an overall significance level of 0.05. Results: RTOG 0515 accrued 52 patients, 47 of whom are evaluable. The follow-up time for all patients is 12.9 months (2.7-22.2). Tumor staging was as follows: II = 6%; IIIA = 40%; and IIIB = 54%. The GTV was statistically significantly smaller for PET/CT-derived volumes (98.7 vs. 86.2 mL; p < 0.0001). MLDs for PET/CT plans were slightly lower (19 vs. 17.8 Gy; p = 0.06). There was no significant difference in the number of involved nodes (2.1 vs. 2.4), V20 (32% vs. 30.8%), or MED (28.7 vs. 27.1 Gy). Nodal contours were altered by PET/CT for 51% of patients. One patient (2%) has developed an elective nodal failure. Conclusions: PET/CT-derived tumor volumes were smaller than those derived by CT alone. PET/CT changed nodal GTV contours in 51% of patients. The elective nodal failure rate for GTVs derived by PET/CT is quite low, supporting the RTOG standard of limiting the target volume to the primary tumor and involved nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging in Postprostatectomy Radiotherapy Planning

Purpose: To investigate whether the use of magnetic resonance imaging (MRI) in prostate bed treatment planning could influence definition of the clinical target volume (CTV) and organs at risk. Methods and Materials: A total of 21 consecutive patients referred for prostate bed radiotherapy were included in the present retrospective study. The CTV was delineated according to the European Organization for Research and Treatment of Cancer recommendations on computed tomography (CT) and T{sub 1}-weighted (T{sub 1}w) and T{sub 2}-weighted (T{sub 2}w) MRI. The CTV magnitude, agreement, and spatial differences were evaluated on the planning CT scan after registration with the MRI scans. Results: The CTV was significantly reduced on the T{sub 1}w and T{sub 2}w MRI scans (13% and 9%, respectively) compared with the CT scans. The urinary bladder was drawn smaller on the CT scans and the rectum was smaller on the MRI scans. On T{sub 1}w MRI, the rectum and urinary bladder were delineated larger than on T{sub 2}w MRI. Minimal agreement was observed between the CT and T{sub 2}w images. The main spatial differences were measured in the superior and superolateral directions in which the CTV on the MRI scans was 1.8-2.9 mm smaller. In the posterior and inferior border, no difference was seen between the CT and T{sub 1}w MRI scans. On the T{sub 2}w MRI scans, the CTV was larger in these directions (by 1.3 and 1.7 mm, respectively). Conclusions: The use of MRI in postprostatectomy radiotherapy planning resulted in a reduction of the CTV. The main differences were found in the superior part of the prostate bed. We believe T{sub 2}w MRI enables more precise definition of prostate bed CTV than conventional planning CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of a Contrast Agent on Proton Beam Range in Radiotherapy Planning Using Computed Tomography for Patients With Locoregionally Advanced Lung Cancer

Purpose: We evaluated the effect of a contrast agent (CA) on proton beam range in a treatment planning system (TPS) for patients with locoregionally advanced lung cancer. Methods and Materials: Two sets of computed tomography (CT) images (with and without CA) were obtained from 20 patients with lung cancer. Because the increase in Hounsfield unit ( Increment HU) value of the heart and great vessels due to the effect of CA is most prominent among thoracic structures, to evaluate the effect of CA on proton beam range in the TPS, we compared the calculated distal ranges in the plan with CA-enhanced CT with those with corrected CT, in which the HU values of the heart and great vessels in the CA-enhanced CT were replaced by average HU values obtained from the unenhanced CT. Results: The mean Increment HU value and the longest length of the heart and great vessels within the proton beam path in the field that passed through these structures were 189 {+-} 29 HU (range, 110-250 HU) and 7.1 {+-} 1.1 cm (range, 2.6-11.2 cm), respectively. The mean distal range error in the TPS because of the presence of CA was 1.0 {+-} 0.7 cm (range, 0.2-2.6 cm). Conclusion: If CA-enhanced CT images are used for radiotherapy planning using a proton beam for the treatment of lung cancer, our results suggest that the HU values of the heart and great vessels should be replaced by the average HU values of soft tissue to avoid discrepancies between planned and delivered doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimized Planning Target Volume for Intact Cervical Cancer

Purpose: To model interfraction clinical target volume (CTV) variation in patients with intact cervical cancer and design a planning target volume (PTV) that minimizes normal tissue dose while maximizing CTV coverage. Methods and Materials: We analyzed 50 patients undergoing external-beam radiotherapy for intact cervical cancer using daily online cone-beam computed tomography (CBCT). The CBCTs (n = 972) for each patient were rigidly registered to the planning CT. The CTV was delineated on the planning CT (CTV{sub 0}) and the set of CBCTs ({l_brace}CTV{sub 1}-CTV{sub 25}{r_brace}). Manual (n = 98) and automated (n = 668) landmarks were placed over the surface of CTV{sub 0} with reference to defined anatomic structures. Normal vectors were extended from each landmark, and the minimum length required for a given probability of encompassing CTV{sub 1}-CTV{sub 25} was computed. The resulting expansions were used to generate an optimized PTV. Results: The mean (SD; range) normal vector length to ensure 95% coverage was 4.3 mm (2.7 mm; 1-16 mm). The uniform expansion required to ensure 95% probability of CTV coverage was 13 mm. An anisotropic margin of 20 mm anteriorly and posteriorly and 10 mm superiorly, inferiorly, and laterally also would have ensured a 95% probability of CTV coverage. The volume of the 95% optimized PTV (1470 cm{sup 3}) was significantly lower than both the anisotropic PTV (2220 cm{sup 3}) and the uniformly expanded PTV (2110 cm{sup 3}) (p < 0.001). For a 95% probability of CTV coverage, normal lengths of 1-3 mm were found along the superior and lateral regions of CTV{sub 0}, 5-10 mm along the interfaces of CTV{sub 0} with the bladder and rectum, and 10-14 mm along the anterior surface of CTV{sub 0} at the level of the uterus. Conclusion: Optimizing PTV definition according to surface landmarking resulted in a high probability of CTV coverage with reduced PTV volumes. Our results provide data justifying planning margins to use in practice and clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole Brain Irradiation With Hippocampal Sparing and Dose Escalation on Multiple Brain Metastases: A Planning Study on Treatment Concepts

Purpose: To develop a new treatment planning strategy in patients with multiple brain metastases. The goal was to perform whole brain irradiation (WBI) with hippocampal sparing and dose escalation on multiple brain metastases. Two treatment concepts were investigated: simultaneously integrated boost (SIB) and WBI followed by stereotactic fractionated radiation therapy sequential concept (SC). Methods and Materials: Treatment plans for both concepts were calculated for 10 patients with 2-8 brain metastases using volumetric modulated arc therapy. In the SIB concept, the prescribed dose was 30 Gy in 12 fractions to the whole brain and 51 Gy in 12 fractions to individual brain metastases. In the SC concept, the prescription was 30 Gy in 12 fractions to the whole brain followed by 18 Gy in 2 fractions to brain metastases. All plans were optimized for dose coverage of whole brain and lesions, simultaneously minimizing dose to the hippocampus. The treatment plans were evaluated on target coverage, homogeneity, and minimal dose to the hippocampus and organs at risk. Results: The SIB concept enabled more successful sparing of the hippocampus; the mean dose to the hippocampus was 7.55 {+-} 0.62 Gy and 6.29 {+-} 0.62 Gy, respectively, when 5-mm and 10-mm avoidance regions around the hippocampus were used, normalized to 2-Gy fractions. In the SC concept, the mean dose to hippocampus was 9.8 {+-} 1.75 Gy. The mean dose to the whole brain (excluding metastases) was 33.2 {+-} 0.7 Gy and 32.7 {+-} 0.96 Gy, respectively, in the SIB concept, for 5-mm and 10-mm hippocampus avoidance regions, and 37.23 {+-} 1.42 Gy in SC. Conclusions: Both concepts, SIB and SC, were able to achieve adequate whole brain coverage and radiosurgery-equivalent dose distributions to individual brain metastases. The SIB technique achieved better sparing of the hippocampus, especially when a10-mm hippocampal avoidance region was used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Uncertainties in Treatment Planning for Scanned Ion Beam Therapy of Moving Tumors

Purpose: To provide methods for quantification of uncertainties in 4-dimensional (4D) treatment during treatment planning. Methods and Materials: Uncertainty information was generated by multiple 4D treatment simulations with varying parameters. Sampled data were analyzed using uncertainty visualization methods that have been added to common treatment plan evaluation methods (eg, dose-volume histogram and dose distribution analysis). To illustrate the potential of the introduced methods, uncertainty analysis was completed for a single lung cancer case using 3 motion mitigation techniques: gating, slice-by-slice rescanning, and breath-controlled rescanning. Results: By repeating 4D dose calculations with varying parameters, we were able to show local uncertainties in dose distributions and to evaluate the stability of treatment setups. The new methods were found suitable for uncertainty evaluation in 4D treatment planning of moving tumors. Calculation time of the uncertainty base data was time consuming but contrivable overnight. Conclusions: Uncertainty analysis and visualization for 4D treatment planning provide an important tool in the decision process for an optimal treatment approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of MR Imaging/MR Spectroscopy-Planned Focal Partial Salvage Permanent Prostate Implant (PPI) for Localized Recurrence After Initial PPI for Prostate Cancer

Purpose: To assess the feasibility of magnetic resonance imaging (MRI)-planned partial salvage permanent prostate implant (psPPI) among patients with biopsy-proven local recurrence after initial PPI without evidence of distant disease. Methods and Materials: From 2003-2009, 15 patients underwent MRI/magnetic resonance spectroscopy (MRS) planning for salvage brachytherapy (psPPI, I-125 [n=14; 144 Gy]; Pd-103 [n=1; 125 Gy]) without hormone therapy. Full dose was prescribed to areas of recurrence and underdosage, without entire prostate implantation. Limiting urethral and rectal toxicity was prioritized. Follow-up was from salvage date to prostate-specific antigen (PSA) concentration failure (Phoenix criteria = nadir + 2.0; ASTRO = 3 consecutive rises), recurrence, distant metastases, or last follow-up PSA level. Progression-free survival (PFS) was defined as no PSA failure or biopsy-proven recurrence without all-cause mortality. Toxicity was scored using Common Terminology Criteria for Adverse Events version 4.0. Results: At salvage, median age was 68 years, and PSA concentration was 3.5 ng/mL (range, 0.9-5.6 ng/mL). Abnormal MRI/MRS findings were evident in 40% of patients. Biopsy-proven recurrences consisted of a single focus (80%) or 2 foci (20%). At recurrence, Gleason score was 6 (67%) or {>=}7 (27%). Median interval between initial and salvage implantation was 69 months (range, 28-132 months). psPPI planning characteristics limited doses to the rectum (mean V100 = 0.5% [0.07 cc]) and urethra (V100 = 12% [0.3 cc]). At median follow-up (23.3 months; range, 8-88 months), treatment failure (n=2) resulted only in localized recurrence; both patients underwent second psPPI with follow-up PSA tests at 12 and 26 months, resulting in 0.6 and 0.7 ng/mL, respectively. American Society for Radiation Oncology PFS rates at 1, 2, and 3 years were 86.7%, 78.4%, and 62.7%, respectively, with 5 patients for whom treatment failed (n=3 with negative transrectal ultrasound-guided biopsy results). Phoenix PFS rates at 1, 2, and 3 years were 100%, 100%, and 71.4%. 73%, respectively; achieved PSA nadir of <0.5 ng/mL; and 47% of patients had a nadir of <0.1 ng/mL. Treatment-related toxicity was minimal, with no operative interventions, fistulas, or other grade {>=}3 gastrointestinal (GI)/genitourinary (GU) toxicity. Thirteen percent had grade 1 GI and 33% had grade 2 GU toxicities. Postsalvage, 20% of patients had no erectile dysfunction, 67% of patients had medication-responsive erectile dysfunction, and 13% of patients had erectile dysfunction refractory to medication. Conclusions: Focal psPPI with MR-planning in highly selected patients is feasible with short-term control comparable to conventional salvage, with less toxicity. Longer follow-up is needed to confirm its impact on quality of life and treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Evaluation of Normalized Metal Artifact Reduction in kVCT Using MVCT Prior Images (MVCT-NMAR) for Radiation Therapy Treatment Planning

Purpose: To evaluate the metal artifacts in diagnostic kilovoltage computed tomography (kVCT) images of patients that are corrected by use of a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images: MVCT-NMAR. Methods and Materials: MVCT-NMAR was applied to images from 5 patients: 3 with dual hip prostheses, 1 with a single hip prosthesis, and 1 with dental fillings. The corrected images were evaluated for visualization of tissue structures and their interfaces and for radiation therapy dose calculations. They were compared against the corresponding images corrected by the commercial orthopedic metal artifact reduction algorithm in a Phillips CT scanner. Results: The use of MVCT images for correcting kVCT images in the MVCT-NMAR technique greatly reduces metal artifacts, avoids secondary artifacts, and makes patient images more useful for correct dose calculation in radiation therapy. These improvements are significant, provided the MVCT and kVCT images are correctly registered. The remaining and the secondary artifacts (soft tissue blurring, eroded bones, false bones or air pockets, CT number cupping within the metal) present in orthopedic metal artifact reduction corrected images are removed in the MVCT-NMAR corrected images. A large dose reduction was possible outside the planning target volume (eg, 59.2 Gy to 52.5 Gy in pubic bone) when these MVCT-NMAR corrected images were used in TomoTherapy treatment plans without directional blocks for a prostate cancer patient. Conclusions: The use of MVCT-NMAR corrected images in radiation therapy treatment planning could improve the treatment plan quality for patients with metallic implants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Online Adaptive Hyperthermia Treatment Planning: Correlation Between Measured and Simulated Specific Absorption Rate Changes Caused by Phase Steering in Patients

Purpose: Hyperthermia is the clinical application of heat, in which tumor temperatures are raised to 40°C to 45°C. This proven radiation and chemosensitizer significantly improves clinical outcome for several tumor sites. Earlier studies of the use of pre-treatment planning for hyperthermia showed good qualitative but disappointing quantitative reliability. The purpose of this study was to investigate whether hyperthermia treatment planning (HTP) can be used more reliably for online adaptive treatment planning during locoregional hyperthermia treatments. Methods and Materials: This study included 78 treatment sessions for 15 patients with non-muscle-invasive bladder cancer. At the start of treatments, temperature rise measurements were performed with 3 different antenna settings optimized for each patient, from which the absorbed power (specific absorption rate [SAR]) was derived. HTP was performed based on a computed tomography (CT) scan in treatment position with the bladder catheter in situ. The SAR along the thermocouple tracks was extracted from the simulated SAR distributions. Correlations between measured and simulated (average) SAR values were determined. To evaluate phase steering, correlations between the changes in simulated and measured SAR values averaged over the thermocouple probe were determined for all 3 combinations of antenna settings. Results: For 42% of the individual treatment sessions, the correlation coefficient between measured and simulated SAR profiles was higher than 0.5, whereas 58% showed a weak correlation (R of <0.5). The overall correlation coefficient between measured and simulated average SAR was weak (R=0.31; P<.001). The measured and simulated changes in average SAR after adapting antenna settings correlated much better (R=0.70; P<.001). The ratio between the measured and simulated quotients of maximum and average SARs was 1.03 ± 0.26 (mean ± SD), indicating that HTP can also correctly predict the relative amplitude of SAR peaks. Conclusions: HTP can correctly predict SAR changes after adapting antenna settings during hyperthermia treatments. This allows online adaptive treatment planning, assisting the operator in determining antenna settings resulting in increased tumor temperatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗