Project Overview: LA13-FY13-123-PD08

This project was a two year, LANL-led effort focused on extending the application of ion emitter sources in thermal ionization mass spectrometry based analysis of trace actinide systems. Particular emphasis was geared towards thorium isotope quantitation, both as a TIMS “worst case” scenario in terms of ionization efficiency and a desirable target for future chronometric measurements. Additional points of focus included source performance characteristics and identification of next-generation emitter strategies addressing remaining development challenges.

47 OTHER INSTRUMENTATION↗

Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for evaluation). • Explored improvements to carbonate-peroxide rapid uranium extraction chemistry. • Evaluated new sampling materials and methods (in collaboration with ORNL). • Demonstrated successful ES extractions from standard and novel swipes for a wide range uranium compounds of interest including UO 2 F 2 and UO 2 (NO 3 ) 2 , U 3 O 8 and uranium ore concentrate. • Completed initial discussions with commercial suppliers of PTFE swipe materials. • Submitted one manuscript for publication. Two additional drafts are being prepared. Principal progress and accomplishments on Task 2, Optimize Materials and Methods for Direct SIMS Environmental Sample Analysis, are listed below. • Designed a SIMS swipe sample holder that retrofits into existing equipment and provides simple, effective, and rapid mounting of ES samples for direct assay while enabling automation and laboratory integration. • Identified preferred conductive sampling materials with better performance characteristics. • Ran samples on the new PNNL NWAL equivalent Cameca 1280 SIMS system. • Obtained excellent agreement between isotopic ratios for certified materials and direct SIMS assay of very low levels of LEU and HEU UO 2 F 2 particles on carbon fiber sampling material. Sample activities range from 1 to 500 CPM (uranium mass on sample is dependent upon specific isotope ratio but is frequently in the subnanogram range). • Found that the presence of the UF molecular ions, as measured by SIMS, provides chemical information about the particle that is separate from the uranium isotopics and strongly suggests that those particles originated from an UF6 enrichment activity. • Submitted one manuscript for publication. Another manuscript is in preparation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Pre-inverted SESAME data table construction enhancements to correct unexpected inverse interpolation pathologies in EOSPAC 6

It was recently demonstrated that EOSPAC 6 continued to incorrectly create and interpolate pre-inverted SESAME data tables after the release of version 6.3.2beta.2. Significant interpolation pathologies were discovered to occur when EOSPAC 6's host software enabled pre-inversion with the EOS_INVERT_AT_SETUP option. This document describes a solution that uses data transformations found in EOSPAC 5 and its predecessors. The numerical results and performance characteristics of both the default and pre-inverted interpolation modes in both EOSPAC 6.3.2beta.2 and the fixed logic of EOSPAC 6.4.0beta.1 are presented herein, and the latter software release is shown to produce significantly-improved numerical results for the pre-inverted interpolation mode.

97 MATHEMATICS AND COMPUTING↗

2017 Guralp Affinity Digitizer Evaluation.

Sandia National Laboratories has tested and evaluated two Guralp Affinity digitizers. The Affinity digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self- noise, dynamic range, system noise, response, passband, and timing. The Affinity digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Design, Test and Demonstration of Fault Current Limiting HTS Transformer

The project developed new technology that enables the creation of a high temperature superconductor-based FCL power transformer. SuperPower’s research and development created new methods to bond HTS conductor to a supporting substrate, test, and insulate the resulting bonded conductor, reduce winding ac losses, ensure FCL functionality during a transformer fault and build firm superconducting joints in the transformer harnesses and cabling. The bonded conductor in this program was shown to meet the critical operating parameters of providing the superconducting transformer operation while being able to meet the target normal state resistance required for FCL operation. The bonded conductor was also shown to be able to handle the fabrication stresses associated with the manufacture of the FCL transformer while also being able to handle the high hoop stresses and axial forces during a fault transient. Much of the technology developed here is applicable to the broader applied superconductivity community. The ability to tailor the clad conductors performance characteristics gives the designer of devices utilizing HTS a broader capability to address the particular needs of an given application. SuperPower worked with its sub-recipients Waukesha Electric Systems, ORNL, Southern California Edison and University of Houston to develop the design, fabrication, installation and operational aspects of a fault current limiting transformer on the electrical grid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Next Generation Qualification: Guralp Systems Affinity Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Affinity, manufactured by Guralp Systems Ltd. These digitizers are used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Affinity digitizer is Guralp's latest release in their digitizer product line. The Affinity is available with either 4 or 8 channels at 24 bit resolution. In addition to the 24 bit channels, 16 multiplexed low resolution channels are provided. Other features include the means to accept multiple types of timing sources (e.g. GPS, NTP and PTP) and a web page interface for command and control of the unit.

47 OTHER INSTRUMENTATION↗

Next Generation Qualification: Quanterra Q330HR Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Q330HR, manufactured by Quanterra. These digitizers are used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Q330HR is Quanterra’s improved Q330 datalogger with a 26 bits of resolution on channels 1-3 and a 24 bits of resolution on channels 4-6 (26 bit is optional). The Quanterra Q330HR is being evaluated for potential use U.S. Air Force seismic monitoring systems as part of their Next Generation Qualification effort.

47 OTHER INSTRUMENTATION↗

Next Generation Qualification: Nanometrics Centaur Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Centaur, manufactured by Nanometrics. These digitizers are used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Centaur digitizer is Nanometrics’ replacement for their Taurus digitizer and marks Nanometrics first 6 channel, 24 bit resolution system. Other improvements include LED status indicators on the top of the unit, providing basic status of the core systems of a seismic station (e.g. timing, sensor SOH, storage, etc), an optional wifi system allowing password protected access to the unit and a web interface for monitoring and configuration of the unit. The Nanometrics Centaur is being evaluated for potential use U.S. Air Force seismic monitoring systems as part of their Next Generation Qualification effort.

47 OTHER INSTRUMENTATION↗

Next Generation Qualification: Geotech Instruments SMART24B Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a digitizer, the SMART24B, manufactured by Geotech Instruments, LLC. These digitizers are used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The SMART24B is Geotech's datalogger intended for borehole deployment in their digitizer product line. The SMART24B is available with either 3 or 6 channels at 24 bit resolution. The digitizer is to be deployed in boreholes, therefore are a minimum number of connections required on the digitizer case as datalogger utilizes a distribution panel, mounted up-hole, serving to breakout power, GPS, serial communications and ethernet connections.

47 OTHER INSTRUMENTATION↗

2018 Nanometrics Centaur Digitizer Evaluation

Sandia National Laboratories has tested and evaluated two Nanometrics Centaur digitizers. The Centaur digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self- noise, dynamic range, system noise, response, passband, and timing. The Centaur digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

High Performance Cast Aluminum Alloys for Next Generation Passenger Vehicle Engines

The purpose of this Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC, and FCA US LLC (herein referred to individually as “FCA US”) and Nemak USA, Inc., (herein referred to individually as “Nemak”) was to develop higher performance cast aluminum alloy compositions that will enable higher efficiency engines for gasoline passenger on-road vehicles. The cast aluminum engine alloys that are standard across the automotive industry, such as 319 and 356 type aluminum, have now been available for several decades. The design and implementation of higher efficiency passenger automotive engines is currently limited by the absence of economical lightweight materials with improved castability, high temperature strength and fatigue performance. Integrated computational materials engineering (ICME) based iterative design and development of a new class of cast aluminum alloys referred to as ACMZ alloys was performed in this CRADA project. ACMZ alloys have targeted high temperature performance characteristics compared to industry standard 319 and 356 alloys. Several versions of ACMZ alloys were successfully cast (>120 in number) by Nemak into a production aluminum cylinder head design. Three of these cylinder heads were machined successfully on the baseline cylinder head production line, with no machinability issue. One such cylinder head completed a durability test schedule at FCA US. Preliminary test results suggest that the new family of cast aluminum alloys may provide opportunity for the automotive industry to increase engine and vehicle efficiency based on increased thermal efficiencies. A commercialization plan has been developed that will allow the introduction of these alloys in commercial vehicles.

36 MATERIALS SCIENCE↗

Initial Assessment for a Generic Horizontal Fissile Solution Vessel with an Electron Beam-based Neutron Generator

The LANL NA-23 program office has provided an extensive design study for a medical isotope (i.e. Molybdenum-99) production facility based on a fissile solution vessel with various accelerator technologies. These concept designs and associated R&D have provided affordable pathways for system optimization for industry counter partner such as SHINE and Global Medial Isotope Supply (GMIS). A horizontal fissile solution vessel design with an electron beam (E-beam) accelerator is proposed and studied with modeling capabilities developed for previous concepts (i.e. a generic vertical fissile solution vessel with a deuterium-tritium (DT) accelerator). An initial system assessment is performed by estimating theoretical Molybdenum-99 production yield with MCNP6.2. A baseline system configuration is constructed based on early design discussions between LANL and GMIS. Since only an initial design concept is available at this stage, all associated system design parameters can be adjusted to fit the best system performance characteristics. In this work, unlike previous vertical system studies, the cooling configuration of the horizontal fissile solution vessel is not considered, and only fission reactions are used to quantify the theoretical product yield. Five parametric design studies are proposed, preliminary results are briefly reported, and extended design studies beyond what is proposed here are also discussed. It is concluded that a comprehensive system analysis via multiphysics coupled calculation developed by LANL should be further conducted for the final design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of X-Ray FEL Oscillators with Higher Out-Coupling Efficiency

This program focused on the development of high-outcoupling efficiency resonators for x-ray free-electron laser oscillators (XFELOs). The goal was to produce a viable design for an XFELO that can be implemented on the LCLS-II which is the x-ray FEL facility under construction at the Stanford Linear Accelerator Center (SLAC). The program designed at regenerative amplifier (RAFEL) design that employs a high-gain undulator with a low-Q resonator with the goal of producing a scientific design for the RAFEL as well as a software suite that can be used to design XFELOs. The Phase I program considered a resonator consisting of six diamond Bragg reflectors/mirrors with two focusing lenses. This resonator was used in conjunction with the electron beam produced by the LCLS-II and the HXR undulator to design a RAFEL producing 3.05 keV photons in the fundamental resonance and 9.15 keV photons in the 3rd harmonic. The research program included the extension of the Optics Propagation Code (OPC) to describe Bragg reflection from diamond crystal mirrors and went on to use OPC, in conjunction with the MINERVA simulation code to treat the undulator interaction, to simulate the RAFEL. Simulations were conducted in both the steady-state and time-dependent regimes to determine the basic performance characteristics of the RAFEL.

43 PARTICLE ACCELERATORS↗

Performance Efficiency and Effectivness of Supercomputers

Our first purpose here is to offer to a general technical and policy audience a perspective on whether the supercomputing community should focus on improving the efficiency of supercomputing systems and their use rather than on building larger and ostensibly more capable systems that are used at low efficiency. After first summarizing our content and defining some necessary terms, we give a concise answer to this question. We then set this in context by characterizing performance of current supercomputing systems on a variety of benchmark problems and actual problems drawn from workloads in the national security, industrial, and scientific context. Along the way we answer some related questions, identify some important technological trends, and offer a perspective on the significance of these trends. Our second purpose is to give a reasonably broad and transparent overview of the related issue space and thereby to better equip the reader to evaluate commentary and controversy concerning supercomputing performance. For example, questions repeatedly arise concerning the Linpack benchmark and its predictive power, so we consider this in moderate depth as an example. We also characterize benchmark and application performance for scientific and engineering use of supercomputers and offer some guidance on how to think about these. Examples here are drawn from traditional scientific computing. Other problem domains, for example, data analytics, have different performance characteristics that are better captured by different benchmark problems or applications, but the story in those domains is similar in character and leads to similar conclusions with regard to the motivating question.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Guralp Affinity Evaluation for SNL Infrasound Testbed

Sandia National Laboratories has tested and evaluated a new digitizer, the Affinity, manufactured by Guralp Systems. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, self-noise, dynamic range, system noise, relative transfer function, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Affinity provides eight, rather the typical six, channels of 24 bit high sample rate digitization. Moreover, it also provides 16 single-ended, 24 bit resolution, low sample rate auxiliary channels. The Affinity digitizer is undergoing these tests prior to installation in the FACT site infrasound test bed.

47 OTHER INSTRUMENTATION↗

Baseline Characterization Database Verification Report – NBG-18 Billet 635-4

This engineering calculations and analysis report is a validity evaluation of the physical and mechanical property databases collected on a billet of nuclear grade graphite (i.e., NBG-18 Billet 635-4) in support of the Advanced Reactor Technologies Baseline Graphite Characterization Program. Millions of raw data points that have been collected during testing and quantification analyses for these billets, the summary scalar property values and supplementary traceability data are collected into comprehensive spreadsheets. Data sets are comprised of single billets of graphite for any given grade, organized by mechanical test specimen type and further subdivided into individual spreadsheet tabs according to the specific test or evaluation being performed. This report is not a direct analysis of properties and will not provide information on the validity or performance characteristics of the graphite itself. Rather, it is intended as a verification of the completeness of actual data collected in accordance with PLN-3467, “Baseline Graphite Characterization Plan: Electromechanical Testing,” and its representation of the measurement and test results with sole regard to the graphite billets under evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

2019 Hyperion 5313A and 5119A Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated two variations of a new model of infrasound sensor, the Hyperion 5313A and 5119A. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The Hyperion infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the Nanometrics Centaur Digitizer

Sandia National Laboratories has tested and evaluated a new digitizer, the Centaur, manufactured by Nanometrics, Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power, sensitivity, self-noise, dynamic range, system noise, modified noise power ration, relative transfer function, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Centaur provides six channels of 24 bit digitization, three of which may be transmitted utilizing CD1.1 protocol.