Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPENINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Dissipation in open holography

We exploit the holographic realization of a conformal theory coupled to an external bath realized via a double trace deformation and its gravity dual in terms of transparent boundary conditions in order to map out some basic dissipative properties of this simple open holographic system. In particular, we determine the energy transmission coefficient across the boundary, discover a novel duality relating weak and strong coupling to the external bath, and quantify the dissipation in the system by working out the quasi normal modes.

AdS-CFT correspondence↗

Transarterial Chemoembolization of Unresectable Hepatocellular Carcinoma with Drug Eluting Beads: Results of an Open-Label Study of 62 Patients

The purpose of this study was to assess the safety and efficacy of doxorubicin-loaded beads (DC Beads) delivered by transarterial embolization for the treatment of unresectable hepatocellular carcinoma (HCC). This open-label, single-center, single-arm study included 62 cirrhotic patients with documented single unresectable HCC. Mean tumor diameter was 5.6 cm (range, 3-9 cm) classified as Okuda stages 1 (n = 53) and 2 (n = 9). Patients received repeat embolizations with doxorubicin-loaded beads every 3 months (maximum of three). The maximum doxorubicin dose was 150 mg per embolization, loaded in DC Beads of 100-300 or 300-500 {mu}m. Regarding efficacy, overall, an objective response according to the European Association for the Study of the Liver criteria was observed in 59.6%, 81.8%, and 70.8% across three treatments. A complete response was observed in 4.8% after the first procedure and 3.6% and 8.3% after the second and third procedures, respectively. At 9 months a complete response was seen in 12.2%, an objective response in 80.7%, progressive disease in 6.8%, and 12.2% showed stable disease. Mean tumor necrosis ranged from 77.4% to 83.9% (range, 28.6%-100%) across three treatments. {alpha}-Fetoprotein levels showed a mean decrease of 1123 ng/ml (95% CI = 846-1399; p = 3 x 10{sup -11}) after the first session and remained stable after the second and third embolizations (42 and 70 ng/ml decrease, respectively). Regarding safety, bilirubin, {gamma}-glutamyl transferase, aspartate aminotransferase, alanine aminotransferase, and alkaline phosphatase showed only transient increases during the study period. Severe procedure-related complications were seen in 3.2% (cholecystitis, n 1; liver abscess, n = 1). Postembolization syndrome was observed in all patients. We conclude that hemoembolization using doxorubicin-loaded DC Beads is a safe and effective treatment of HCC as demonstrated by the low complication rate, increased tumor response, and sustained reduction of {alpha}-fetoprotein levels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-Guided Laser Ablation of Osteoid Osteoma in an Open High-Field System (1.0 T)

Computed tomography is the standard imaging modality to minimize the extent of surgical or ablative treatment in osteoid osteomas. In the last 15 years, since a description of thermal ablation of osteoid osteomas was first published, this technique has become a treatment of choice for this tumor. We report the case of a 20-year-old man with an osteoid osteoma treated with laser ablation in an open high-field magnetic resonance imaging scanner (1.0 T). The tumor, located in the right fibula, was safely and effectively ablated under online monitoring. We describe the steps of this interventional procedure and discuss related innovative guidance and monitoring features and potential benefits compared with computed tomographic guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Magnetic Resonance Imaging-Compatible Needles and Interactive Sequences for Musculoskeletal Interventions Using an Open High-Field Magnetic Resonance Imaging Scanner

In this article, we study in vitro evaluation of needle artefacts and image quality for musculoskeletal laser-interventions in an open high-field magnetic resonance imaging (MRI) scanner at 1.0T with vertical field orientation. Five commercially available MRI-compatible puncture needles were assessed based on artefact characteristics in a CuSO4 phantom (0.1%) and in human cadaveric lumbar spines. First, six different interventional sequences were evaluated with varying needle orientation to the main magnetic field B0 (0{sup o} to 90{sup o}) in a sequence test. Artefact width, needle-tip error, and contrast-to-noise ratio (CNR) were calculated. Second, a gradient-echo sequence used for thermometric monitoring was assessed and in varying echo times, artefact width, tip error, and signal-to-noise ratio (SNR) were measured. Artefact width and needle-tip error correlated with needle material, instrument orientation to B0, and sequence type. Fast spin-echo sequences produced the smallest needle artefacts for all needles, except for the carbon fibre needle (width <3.5 mm, tip error <2 mm) at 45{sup o} to B0. Overall, the proton density-weighted spin-echo sequences had the best CNR (CNR{sub Muscle/Needle} >16.8). Concerning the thermometric gradient echo sequence, artefacts remained <5 mm, and the SNR reached its maximum at an echo time of 15 ms. If needle materials and sequences are accordingly combined, guidance and monitoring of musculoskeletal laser interventions may be feasible in a vertical magnetic field at 1.0T.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Protein Data Bank archive as an open data resource

The Protein Data Bank archive was established in 1971, and recently celebrated its 40th anniversary (Berman et al. in Structure 20:391, 2012). Here, an analysis of interrelationships of the science, technology and community leads to further insights into how this resource evolved into one of the oldest and most widely used open-access data resources in biology.

59 BASIC BIOLOGICAL SCIENCES↗

Surface-Modified Cellulose Nanofibers-graft-poly(lactic acid)s Made by Ring-Opening Polymerization of L-Lactide

Highly crystalline cellulose nanofibers with a high density of carboxylate groups only on the surfaces were prepared from both softwood and non-wood cellulose pulp. The preparation method used 2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPO)-mediated oxidation of native cellulose fibrils in an aqueous TEMPO/NaBr/NaClO system and subsequent postoxidation with NaClO{sub 2} in acetate buffer (pH 4.8). The TEMPO-oxidized cellulose nanofibers (TOCNs) possessed a carboxylate content of 1.7 mmol g{sup −1} and a crystallinity of 67–69% with a crystallite size of ∼3 nm. The TOCNs were used to produce highly crystalline TOCN-graft-poly(lactic acid) (PLA) nanocomposites via ring-opening polymerization of L-lactide in a polar aprotic solvent. Effects of the reaction temperature and the molar ratio of L-lactide to carboxylate surface groups, on the efficiency of surface grafting were investigated to potentially improve the crystallinity and thermal properties of the nanocomposites. The crystallinity of TOCN-g-PLA products was 59–66% greater than the crystallinity of neat PLA.

36 MATERIALS SCIENCE↗

Soybean Oil Modified Bio-based Poly(vinyl alcohol)s via Ring-Opening Polymerization

In this paper, a simple method to modify the poly(vinyl alcohol) (PVA) through ring-opening reaction of epoxidized soybean oil (ESBO), catalyzed by hydrochloric acid is reported. The effect of ESBO loading ratio, in terms of mole (PVA/ESBO (n/n) = 1:0.5; 1:1 and 1:1.5) in the reaction medium, on the biodegradable, wettability and thermal properties of final PVA-SBO films is systematically investigated, comparing with PVA. The formation of PVA-SBOs is structurally confirmed by Fourier transform infrared (FT-IR) spectroscopy, whereas their wettability and thermal properties are studied by water contact angle (WCA) measurement, thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC), respectively. The obtained PVA-SBOs with higher ESBO loading exhibit both improved thermal properties and higher hydrophobic characteristic compared to others. Furthermore, biodegradability of resulting PVA-SBOs is also investigated by enzymatic degradation experiments. It is determined that around 34% of PVA is degraded by enzymatic experiments after 30 days and PVA-SBO with lower ESBO loading is more degraded than others with around 52%. Consequently, some experimental results are presented to indicate that PVA-SBOs are encouraging materials for diverse applications and their extensions can be good candidate for reducing the environmental problem and consumption of petroleum resources.

36 MATERIALS SCIENCE↗

Ex Situ Spark Plasma Sintering of Short Powder-in-Tube MgB{sub 2} Tapes with Open and Closed Ends

Short powder-in-tube tapes of MgB{sub 2} in the Fe sheath were fabricated by ex situ route from a commercial powder containing some free Mg and MgO impurity phases. The final heat treatment was performed by spark plasma sintering (SPS). Tapes were with open (OT) or closed (CT) endings. Closed endings were made by folding and pressing. The MgB{sub 2} core of the OT sample has shown a higher low-field critical current density, a higher maximum pinning force, a slightly higher disorder, smaller average MgB{sub 2} crystallite size, a weak contact between Fe and MgB{sub 2} core, and more macro-flux jumps. The upper and irreversibility fields were similar for OT and CT samples. In the center of the MgB{sub 2} cores, the detected impurity phase is MgO, while at the interface with Fe, MgB{sub 4} also occurs. Impurity phases found at interface, MgO and MgB{sub 4}, are present in the center of the bulk SPSed samples. Reactions and pinning-force-related parameters are discussed with respect to Mg behavior influenced by condition of endings. It is inferred that the presence of free Mg in the raw MgB{sub 2} powder has an important contribution to observed differences, and its removal or control is recommended.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Emulation of complex open quantum systems using superconducting qubits

With quantum computers being out of reach for now, quantum simulators are alternative devices for efficient and accurate simulation of problems that are challenging to tackle using conventional computers. Quantum simulators are classified into analog and digital, with the possibility of constructing “hybrid” simulators by combining both techniques. Here we focus on analog quantum simulators of open quantum systems and address the limit that they can beat classical computers. In particular, as an example, we discuss simulation of the chlorosome light-harvesting antenna from green sulfur bacteria with over 250 phonon modes coupled to each electronic state. Furthermore, we propose physical setups that can be used to reproduce the quantum dynamics of a standard and multiple-mode Holstein model. The proposed scheme is based on currently available technology of superconducting circuits consist of flux qubits and quantum oscillators.

97 MATHEMATICS AND COMPUTING↗

Modeling of Liquid Steel/Slag/Argon Gas Multiphase Flow During Tundish Open Eye Formation in a Two-Strand Tundish

Multiphase flows are frequently encountered in metallurgical operations. One of the most effective ways to understand these processes is by flow modeling. The process of tundish open eye (TOE) formation involves three-phase interaction between liquid steel, slag, and argon gas. The two-phase interaction involving argon gas bubbles and liquid steel can be modeled relatively easily using the discrete phase modeling technique. However, the effect of an upper slag layer cannot be captured using this approach. The presence of an upper buoyant phase can have a major effect on the behavior of TOEs. Hence, a multiphase model, including three phases, viz. liquid steel, slag, and argon gas, in a two-strand slab caster tundish, was developed to study the formation and evolution of TOEs. The volume of fluid model was used to track the interphase between liquid steel and slag phases, while the discrete phase model was used to trace the movement of the argon gas bubbles in liquid steel. The variation in the TOE areas with different amounts of aspirated argon gas was examined in the presence of an overlying slag phase. The mathematical model predictions were compared against steel plant measurements.

36 MATERIALS SCIENCE↗

Prediction of the Stress–Strain Behavior of Open-Cell Aluminum Foam under Compressive Loading and the Effects of Various RVE Boundary Conditions

The prediction of the mechanical behavior of metallic foams with realistic microstructure and the effects of various boundary conditions on the mechanical behavior is an important and challenging issue in modeling representative volume elements (RVEs). A numerical investigation is conducted to determine the effects of various boundary conditions and cell wall cross sections on the compressive mechanical properties of aluminum foam, including the stiffness, plateau stress and onset strain of densification. The open-cell AA6101-T6 aluminum foam Duocel is used in the analyses in this study. Geometrical characteristics including the cell size, foam relative density, and cross-sectional shape and thickness of the cell walls are extracted from images of the foam. Then, the obtained foam microstructure is analyzed as a 2D model. The ligaments are modeled as shear deformable beams with elastic-plastic material behavior. To prevent interpenetration of the nodes and walls inside the cells with large deformations, self-contact-type frictionless interaction is stipulated between the internal surfaces. Sensitivity analyses are performed using several boundary conditions and cells wall cross-sectional shapes. The predicted results from the finite element analyses are compared with the experimental results. Finally, the most appropriate boundary conditions, leading to more consistent results with the experimental data, are introduced.

36 MATERIALS SCIENCE↗

Micro-slotting Residual Stress Measurement Technique for Understanding Fatigue Performance of Open-Hole Ti-6Al-4V Samples

Micro-slotting, a microscale relaxation residual stress measurement technique, has been shown in recent years to be a reliable method for measuring local residual stresses in metallic materials. This study demonstrates the unique application of the micro-slotting residual stress measurement technique for measuring near-edge tangential residual stresses around cold-expanded holes in Ti-6Al-4V plates. Knowledge of the near-edge elastic strains induced by the hole processing, in combination with plastic strain information obtained using electron backscatter diffraction, allowed for interpretation of fatigue life differences and crack growth behavior between the as-drilled and cold-expanded conditions. The similar crack initiation lives of the as-drilled and cold-expanded open-hole coupons were attributed to the similar elastic and plastic strains present at the hole edges. The subsequent crack growth resistance observed for the cold-expanded holes was a result of the large compressive residual stress region induced by cold expansion.

36 MATERIALS SCIENCE↗

MSiReader v1.0: Evolving Open-Source Mass Spectrometry Imaging Software for Targeted and Untargeted Analyses

A major update to the mass spectrometry imaging (MSI) software MSiReader is presented, offering a multitude of newly added features critical to MSI analyses. MSiReader is a free, open-source, and vendor-neutral software written in the MATLAB platform and is capable of analyzing most common MSI data formats. A standalone version of the software, which does not require a MATLAB license, is also distributed. The newly incorporated data analysis features expand the utility of MSiReader beyond simple visualization of molecular distributions. The MSiQuantification tool allows researchers to calculate absolute concentrations from quantification MSI experiments exclusively through MSiReader software, significantly reducing data analysis time. An image overlay feature allows the incorporation of complementary imaging modalities to be displayed with the MSI data. A polarity filter has also been incorporated into the data loading step, allowing the facile analysis of polarity switching experiments without the need for data parsing prior to loading the data file into MSiReader. A quality assurance feature to generate a mass measurement accuracy (MMA) heatmap for an analyte of interest has also been added to allow for the investigation of MMA across the imaging experiment. Most importantly, as new features have been added performance has not degraded, in fact it has been dramatically improved. These new tools and the improvements to the performance in MSiReader v1.0 enable the MSI community to evaluate their data in greater depth and in less time. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupled tensorial forms of the second-order effective Hamiltonian for open-subshell atoms in jj-coupling

General expressions for the second-order effective atomic Hamiltonian are derived for open-subshell atoms in jj-coupling. The expansion terms are presented as N-body (N=0,1,2,3) effective operators given in the second quantization representation in coupled tensorial form. Two alternative coupled tensorial forms for each expansion term have been developed. To reduce the number of expressions of the effective Hamiltonian, the reduced matrix elements of antisymmetric two-particle wavefunctions are involved in the consideration. The general expressions presented allow the determination of the spin-angular part of expansion terms when studying correlation effects dealing with a number of problems in atomic structure calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Non-equilibrium ϕ{sup 4} theory in open systems as a toy model of quantum field theory of the brain

We investigate non-equilibrium relativistic ϕ{sup 4} theory in open systems (the relevant system and the two reservoirs) as a toy model of quantum field theory of the brain, Quantum Brain Dynamics (QBD). We give time evolution equations of quantum fields, that is the Klein–Gordon (KG) equations for background coherent scalar fields and the Kadanoff–Baym (KB) equations for quantum fluctuations. Next we introduce a relativistic kinetic entropy current with the gradient expansion technique and show the H-theorem in the presence of Next-to-Leading-Order self-energy of the coupling expansion and tunneling between systems in d+1 dimensions. Finally we demonstrate numerical simulations with KG and KB equations in 1+1 dimensions. We find that the decoherence (field–particle conversion), the entropy production and the chemical equilibration occur in time evolution of the relevant system and the two reservoirs. We also demonstrate how the background coherent fields transfer between systems. The presented formalism is proposed as a mathematical representation of QBD.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dynamic modification of pore opening of SAPO-34 by adsorbed surface methoxy species during induction of catalytic methanol-to-olefins reactions

Here, we report that the pore opening of SAPO-34 can be significantly modified by an adsorbed surface methoxy species during induction of the catalytic methanol-to-olefins process, which offers molecular sieving properties due to physical obstacle of the methoxy group and its adsorption modification to other hydrocarbons. X-ray powder diffraction and Rietveld refinement clearly reveal that the adsorbed single carbon atom as the methoxy group is dynamically created from methanol dehydration on a Brønsted acid site in close proximity to the pore windows. As a result, industrial desirable smaller olefins such as ethylene and propylene can be favourably made at the expenses of higher olefins. The structures and fundamental understanding in alteration in the olefins selectivity during induction may allow rational optimisation in catalytic performance under the complex fluidisation conditions.

Environmental Molecular Sciences Laboratory↗

Microalgae to biofuels through hydrothermal liquefaction: Open-source techno-economic analysis and life cycle assessment

Hydrothermal liquefaction is a promising conversion technology in algae biofuel research due to its ability to agnostically convert proteins, carbohydrates, and lipids to biocrude. The high-temperature conditions that define this conversion process require the material to maintain a subcritical liquid state, which complicates the assessment of accurate thermochemical properties due to the required pressure. To clarify this issue, this work compares the estimated performance of algal hydrothermal liquefaction between different thermodynamic models. A process model was developed in Aspen Plus from a robust assessment of current literature. Techno-economic assessment and life-cycle assessment metrics are derived from this model and used as key performance indicators. The baseline fuel price contribution of hydrothermal liquefaction is $0.45 per liter gasoline equivalent. Independently decreasing the temperature from 350 °C to 260 °C while maintaining yield reduces the conversion cost by 19%, illustrating the importance of understanding the high-temperature thermodynamics of the system. Different thermodynamic property models can vary fuel conversion cost results by $0.07 per liter gasoline equivalent. The baseline global warming potential is +23 g CO 2 eq MJ -1 and the net energy ratio is 0.30. Environmental metrics beyond global warming potential and net energy ratio are also discussed for the first time. Uncertainties in conversion performance are bounded through a scenario analysis that manipulates parameters such as product yield and nutrient recycle to produce a range of economic and environmental metrics. The report is supplemented with an open source model to support future hydrothermal liquefaction assessments and accelerate the development of commercial-scale systems.

09 BIOMASS FUELS↗