Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Snowmass 2021 CMB-S4 White Paper

This Snowmass 2021 White Paper describes the Cosmic Microwave Background Stage 4 project CMB-S4, which is designed to cross critical thresholds in our understanding of the origin and evolution of the Universe, from the highest energies at the dawn of time through the growth of structure to the present day. We provide an overview of the science case, the technical design, and project plan.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two-Step Procedure to Detect Cosmological Gravitational Wave Backgrounds with Next-Generation Terrestrial Gravitational-Wave Detectors

Cosmological gravitational-wave backgrounds are an exciting science target for next-generation ground-based detectors, as they encode invaluable information about the primordial Universe. However, any such background is expected to be obscured by the astrophysical foreground from compact-binary coalescences. We propose a novel framework to detect a cosmological gravitational-wave background in the presence of binary black holes and binary neutron star signals with next-generation ground-based detectors, including Cosmic Explorer and the Einstein Telescope. Our procedure involves first removing all the individually resolved binary black hole signals by notching them out in the time-frequency domain. Then, we perform joint Bayesian inference on the individually resolved binary neutron star signals, the unresolved binary neutron star foreground, and the cosmological background. For a flat cosmological background, we find that we can claim detection at 5⁢𝜎 level when Ω ref ≥ 2.7 × 10 −12 /$\sqrt{𝑇_{obs}/yr}$, where 𝑇 obs is the observation time (in years), which is within a factor of ≲ 2 from the sensitivity reached in the absence of these astrophysical foregrounds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DESC DC2 Data Release Note

In preparation for cosmological analyses of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST), the LSST Dark Energy Science Collaboration (LSST DESC) has created a 300 deg$^2$ simulated survey as part of an effort called Data Challenge 2 (DC2). The DC2 simulated sky survey, in six optical bands with observations following a reference LSST observing cadence, was processed with the LSST Science Pipelines (19.0.0). In this Note, we describe the public data release of the resulting object catalogs for the coadded images of five years of simulated observations along with associated truth catalogs. We include a brief description of the major features of the available data sets. To enable convenient access to the data products, we have developed a web portal connected to Globus data services. We describe how to access the data and provide example Jupyter Notebooks in Python to aid first interactions with the data. We welcome feedback and questions about the data release via a GitHub repository.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra high energy cosmic rays The intersection of the Cosmic and Energy Frontiers

The present white paper is submitted as part of the “Snowmass” process to help inform the long-term plans of the United States Department of Energy and the National Science Foundation for high-energy physics. It summarizes the science questions driving the Ultra-High-Energy Cosmic-Ray (UHECR) community and provides recommendations on the strategy to answer them in the next two decades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astrometric Calibration and Performance of the Dark Energy Spectroscopic Instrument Focal Plane

Abstract The Dark Energy Spectroscopic Instrument, consisting of 5020 robotic fiber positioners and associated systems on the Mayall telescope at Kitt Peak, Arizona, is carrying out a survey to measure the spectra of 40 million galaxies and quasars and produce the largest 3D map of the universe to date. The primary science goal is to use baryon acoustic oscillations to measure the expansion history of the universe and the time evolution of dark energy. A key function of the online control system is to position each fiber on a particular target in the focal plane with an accuracy of 11 μ m rms 2D. This paper describes the set of software programs used to perform this function along with the methods used to validate their performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refined Telluric Absorption Correction for Low-resolution Ground-based Spectroscopy: Resolution and Radial Velocity Effects in the O{sub 2}A-band for Exoplanets and K i Emission Lines

Telluric correction of spectroscopic observations is either performed via standard stars that are observed close in time and airmass along with the science target, or recently growing in importance, by theoretical telluric absorption modeling. Both approaches work fine when the telluric lines are resolved, i.e., at a spectral resolving power larger than about 10,000, and it is sufficient to facilitate the detection of spectral features at lower resolution. However, a meaningful quantitative analysis also requires the reliable recovery of line strengths. Here, we show for the Fraunhofer A-band of molecular O{sub 2} that the standard telluric correction approach fails in this at lower spectral resolutions, as an example for the general problem. Doppler-shift-dependent errors of the restored flux may arise, which can amount to more than 50% in extreme cases, depending on the line shapes of the target spectral features. Two applications are discussed: the recovery of the O{sub 2} band in the reflected light of an Earth analog atmosphere, as facilitated potentially in the future using an orbiting starshade and a ground-based extremely large telescope; and the recovery of the intrinsic ratio of the K i lines in the post-nova V4332 Sgr tracing the optical depth of the emitting region, to exemplify the relevance using present-day instrumentation. We show how one should derive correction functions for the compensation of the error in dependence of radial velocity shift, spectral resolution, and target line-profile function by use of high-resolution atmospheric transmission modeling, which has to be solved for the individual case.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Basic Research Needs for High Energy Physics Detector Research & Development: Report of the Office of Science Workshop on Basic Research Needs for HEP Detector Research and Development: December 11-14, 2019

Transformative discovery in science is driven by innovation in technology. Our boldest undertakings in particle physics have at their foundation precision instrumentation. To reveal the profound connections underlying everything we see from the smallest scales to the largest distances in the Universe, to understand its fundamental constituents, and to reveal what is still unknown, we must invent, develop, and deploy advanced instrumentation. Investments in High Energy Physics (HEP) enabled by instrumentation have been richly rewarded with discoveries of the tiny masses of the neutrinos, the origin of mass itself: the enigmatic Higgs boson, and the surprising accelerating expansion of the Universe. What we have learned is remarkable, unexpected, exciting and mysterious; raising many new questions waiting to be answered. The quest to answer them drives innovation that improves the nation's health, wealth, and security, inspiring the public and drawing young people to science. Excellence and innovation come most effectively from diverse teams of people. Success, therefore, depends critically on attracting, engaging, and supporting a diverse cadre of young people to the field, and ensuring an inclusive environment at all levels. The program laid out in the 2014 Particle Physics Projects Prioritization Panel (P5) report "Building for Discovery - A Strategic Plan for U.S. Particle Physics in a Global Context" guides current and near future experiments to exploit these and other discoveries, and the instrumentation innovation they require, to push the frontiers of science into new territory. To explore this territory HEP will soon embark on planning the next generation of experiments. Realizing these experiments will require giant leaps in capabilities beyond the instrumentation of today. Accordingly, now is a pivotal moment to invest in the accelerated development of cost-effective instrumentation with greatly improved sensitivity and performance that will make measurable the unmeasurable, enabling a tool-driven revolution to open the door to future discoveries. Historic scientific opportunities await us, enabled by executing the instrumentation research plan outlined here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Underground Neutrino Experiment (DUNE) Near Detector Conceptual Design Report

The Deep Underground Neutrino Experiment (DUNE) is an international, world-class experiment aimed at exploring fundamental questions about the universe that are at the forefront of astrophysics and particle physics research. DUNE will study questions pertaining to the preponderance of matter over antimatter in the early universe, the dynamics of supernovae, the subtleties of neutrino interaction physics, and a number of beyond the Standard Model topics accessible in a powerful neutrino beam. A critical component of the DUNE physics program involves the study of changes in a powerful beam of neutrinos, i.e., neutrino oscillations, as the neutrinos propagate a long distance. The experiment consists of a near detector, sited close to the source of the beam, and a far detector, sited along the beam at a large distance. This document, the DUNE Near Detector Conceptual Design Report (CDR), describes the design of the DUNE near detector and the science program that drives the design and technology choices. The goals and requirements underlying the design, along with projected performance are given. It serves as a starting point for a more detailed design that will be described in future documents.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Relativistic ultrafast electron diffraction at high repetition rates

The ability to resolve the dynamics of matter on its native temporal and spatial scales constitutes a key challenge and convergent theme across chemistry, biology, and materials science. The last couple of decades have witnessed ultrafast electron diffraction (UED) emerge as one of the forefront techniques with the sensitivity to resolve atomic motions. Increasingly sophisticated UED instruments are being developed that are aimed at increasing the beam brightness in order to observe structural signatures, but so far they have been limited to low average current beams. Here, we present the technical design and capabilities of the HiRES (High Repetition-rate Electron Scattering) instrument, which blends relativistic electrons and high repetition rates to achieve orders of magnitude improvement in average beam current compared to the existing state-of-the-art instruments. The setup utilizes a novel electron source to deliver femtosecond duration electron pulses at up to MHz repetition rates for UED experiments. Instrument response function of sub-500 fs is demonstrated with < 100 fs time resolution targeted in future. We provide example cases of diffraction measurements on solid-state and gas-phase samples, including both micro- and nanodiffraction (featuring 100 nm beam size) modes, which showcase the potential of the instrument for novel UED experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DECam Local Volume Exploration Survey Data Release 2

We present the second public data release (DR2) from the DECam Local Volume Exploration survey (DELVE). DELVE DR2 combines new DECam observations with archival DECam data from the Dark Energy Survey, the DECam Legacy Survey, and other DECam community programs. DELVE DR2 consists of ∼160,000 exposures that cover >21,000 deg$^{2}$ of the high-Galactic-latitude (∣b∣ > 10°) sky in four broadband optical/near-infrared filters (g, r, i, z). DELVE DR2 provides point-source and automatic aperture photometry for ∼2.5 billion astronomical sources with a median 5σ point-source depth of g = 24.3, r = 23.9, i = 23.5, and z = 22.8 mag. A region of ∼17,000 deg$^{2}$ has been imaged in all four filters, providing four-band photometric measurements for ∼618 million astronomical sources. DELVE DR2 covers more than 4 times the area of the previous DELVE data release and contains roughly 5 times as many astronomical objects. DELVE DR2 is publicly available via the NOIRLab Astro Data Lab science platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TDCOSMO - XVII. New time delays in 22 lensed quasars from optical monitoring with the ESO-VST 2.6m and MPG 2.2m telescopes

We present new time delays, the main ingredient of time delay cosmography, for 22 lensed quasars resulting from high-cadence r-band monitoring on the 2.6 m ESO VLT Survey Telescope and Max-Planck-Gesellschaft 2.2 m telescope. Each lensed quasar was typically monitored for one to four seasons, often shared between the two telescopes to mitigate the interruptions forced by the COVID-19 pandemic. The sample of targets consists of 19 quadruply and 3 doubly imaged quasars, which received a total of 1918 hours of on-sky time split into 21 581 wide-field frames, each 320 seconds long. In a given field, the 5-σ depth of the combined exposures typically reaches the 27th magnitude, while that of single visits is 24.5 mag – similar to the expected depth of the upcoming Vera-Rubin LSST. The fluxes of the different lensed images of the targets were reliably de-blended, providing not only light curves with photometric precision down to the photon noise limit, but also high-resolution models of the targets whose features and astrometry were systematically confirmed in Hubble Space Telescope imaging. This was made possible thanks to a new photometric pipeline, lightcurver, and the forward modelling method STARRED. Finally, the time delays between pairs of curves and their uncertainties were estimated, taking into account the degeneracy due to microlensing, and for the first time the full covariance matrices of the delay pairs are provided. Of note, this survey, with 13 square degrees, has applications beyond that of time delays, such as the study of the structure function of the multiple high-redshift quasars present in the footprint at a new high in terms of both depth and frequency. The reduced images will be available through the European Southern Observatory Science Portal.Key words: methods: data analysis / surveys / distance scale

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Quenching in Rare-Earth Inorganic Scintillators: GAGG:Ce and YSO:Ce

Scintillator detectors are an integral component of radiation detection systems for a variety of applications such as medical imaging, accelerator diagnostics, and space science. Typically, a scintillator detector’s response is characterized using gamma sources to understand the detection response to different types of radiation, including charged particle detection. However, there exists a nonlinearity of the amount of light produced from an incident gamma ray of specific energy and the light produced from an incident charged particle of the same energy. This important effect, known as quenching, must be accounted for to interpret energies from charged particles incident on detectors. In this article, we present results of quenching parameterization for two types of cerium-doped inorganic scintillators, Y2SiO5:Ce (YSO:Ce) and Gd3Al2Ga3O12:Ce (GAGG:Ce). We measured the light output from incident proton energies from 1 to 25 MeV using a 3-MV tandem accelerator and two reactions: Au(p,p)Au and 3He(d,p)⁴He. Using gamma-ray sources to calibrate the detectors, we compared the measured electron-equivalent energy versus the incident energy expected. Using an adaptation of the Birks semi-empirical formula, we extracted the Birks parameter (kB) to understand quenching. For one of the GAGG:Ce samples, the kB parameter of 0.0072 [g cm-2 MeV-1] is comparable to a similar study where the value of kB was 0.0065 [g cm-2 MeV-1]. For YSO:Ce, no other kB values were found in the literature. Three different types of GAGG:Ce were used to collect measurements of kB as a function of dopant concentration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AEDGE: Atomic Experiment for Dark Matter and Gravity Exploration in Space

We propose in this White Paper a concept for a space experiment using cold atoms to search for ultra-light dark matter, and to detect gravitational waves in the frequency range between the most sensitive ranges of LISA and the terrestrial LIGO/Virgo/KAGRA/INDIGO experiments. This interdisciplinary experiment, called Atomic Experiment for Dark Matter and Gravity Exploration (AEDGE), will also complement other planned searches for dark matter, and exploit synergies with other gravitational wave detectors. We give examples of the extended range of sensitivity to ultra-light dark matter offered by AEDGE, and how its gravitational-wave measurements could explore the assembly of super-massive black holes, first-order phase transitions in the early universe and cosmic strings. AEDGE will be based upon technologies now being developed for terrestrial experiments using cold atoms, and will benefit from the space experience obtained with, e.g., LISA and cold atom experiments in microgravity. This paper is based on a submission (v1) in response to the Call for White Papers for the Voyage 2050 long-term plan in the ESA Science Programme. ESA limited the number of White Paper authors to 30. However, in this version (v2) we have welcomed as supporting authors participants in the Workshop on Atomic Experiments for Dark Matter and Gravity Exploration held at CERN: ({\tt https://indico.cern.ch/event/830432/}), as well as other interested scientists, and have incorporated additional material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Snowmass2021 Cosmic Frontier: Cosmic Microwave Background Measurements White Paper

This is a solicited whitepaper for the Snowmass 2021 community planning exercise. The paper focuses on measurements and science with the Cosmic Microwave Background (CMB). The CMB is foundational to our understanding of modern physics and continues to be a powerful tool driving our understanding of cosmology and particle physics. In this paper, we outline the broad and unique impact of CMB science for the High Energy Cosmic Frontier in the upcoming decade. We also describe the progression of ground-based CMB experiments, which shows that the community is prepared to develop the key capabilities and facilities needed to achieve these transformative CMB measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗