Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Development of pulsed neutron uranium logging instrument

This article introduces a development of pulsed neutron uranium logging instrument. By analyzing the temporal distribution of epithermal neutrons generated from the thermal fission of {sup 235}U, we propose a new method with a uranium-bearing index to calculate the uranium content in the formation. An instrument employing a D-T neutron generator and two epithermal neutron detectors has been developed. The logging response is studied using Monte Carlo simulation and experiments in calibration wells. The simulation and experimental results show that the uranium-bearing index is linearly correlated with the uranium content, and the porosity and thermal neutron lifetime of the formation can be acquired simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Moderator Performance Calculations at SNS

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory reached a nominal operating power of 1 MW in September, 2009. Even at ~2/3 of its designed capacity, SNS already becomes the brightest pulsed neutron source in the world, and a premier facility for material and life science research. To provide accurate target performance estimation and to meet future development needs, we had developed an as-built model for the operating target system of SNS. Based on this asbuilt model, the moderator performance at SNS was recalculated taking advantage of the improved physics and tallying method in the Monte Carlo simulation code, MCNPX, and most recent scattering kernels. The neutron flux intensity spectra, emission time distributions of neutron pulses and moderator brightness profiles regarding the SNS moderator performance are presented and discussed. Compared to the previous results, the current calculations show ~10-20% lower in flux with improved emission time distributions of neutron pulses. The difference between the two data sets is analyzed, as well as other factors impacting the moderator performance at SNS. The current calculation results will serve as source terms for the instrument performance simulations at SNS.

Lu, Wei↗

Training courses on neutron detection systems on the ISIS research reactor: on-site and through internet training

Today, ISIS research reactor is an essential tool for Education and Training programs organized by the National Institute for Nuclear Science and Technology (INSTN) from CEA. In the field of nuclear instrumentation, the INSTN offers both, theoretical courses and training courses on the use of neutron detection systems taking advantage of the ISIS research reactor for the supply of a wide range of neutron fluxes. This paper describes the content of the training carried out on the use of neutron detectors and detection systems, on-site or remote. The ISIS reactor is a 700 kW open core pool type reactor. The facility is very flexible since neutron detectors can be inserted into the core or its vicinity, and be used at different levels of power according to the needs of the course. Neutron fluxes, typically ranging from 1 to 10{sup 12} n/cm{sup 2}.s, can be obtained for the characterisation of the neutron detectors and detection systems. For the monitoring of the neutron density at low level of power, the Instrumentation and Control (I and C) system of the reactor is equipped with two detection systems, named BN1 and BN2. Each way contains a fission chamber, type CFUL01, connected to an electronic system type SIREX.The system works in pulse mode and exhibits two outputs: the counting rate and the doubling time. For the high level of power, the I and C is equipped with two detection systems HN1 and HN2.Each way contain a boron ionization chamber (type CC52) connected to an electronics system type SIREX. The system works in current mode and has two outputs: the current and the doubling time. For each mode, the trainees can observe and measure the signal at the different stages of the electronic system, with an oscilloscope. They can understand the role of each component of the detection system: detector, cable and each electronic block. The limitation of the detection modes and their operating range can be established from the measured signal. The trainees can also modify the settings of the electronic system, such as the high voltage and the discrimination level in order to obtain all the characteristic curves of the detectors. These curves are used to define the right setting of the electronic system and to discuss the expected degradation of the detector signal resulting from the detector damage under the integrated neutron and gamma fluxes. Moreover, in addition to the study of the neutron detection systems itself, the integration of the measurements made by these detection systems in the logic of the safety system of the nuclear reactor is also addressed. Providing the trainees with an extensive overview of each part of the neutron monitoring instrumentation apply to a nuclear reactor, hands-on measurements on the ISIS reactor play a major role in ensuring a practical and comprehensive understanding of the neutron detection system and their integration in the safety system of nuclear reactors. It also gives a solid background for the follow up and the development of the neutron detection systems. In addition to on-reactor training, Internet Reactor Laboratory capability has been implemented on the ISIS reactor in 2014. For the Internet Reactor Laboratory an extensive video conference system has been implemented on ISIS reactor. The system includes 4 cameras and the transmission of the video signal given by the supervision system of the reactor which records and processes the data of the reactor. According to the pedagogic needs during the training courses, the lecturer on the ISIS reactor chooses to broadcast the relevant information at each stage of the course. For example, graph showing the histogram of the counting and current as a function of the time, or the electrical signal observed on the oscilloscope, can be broadcasted trough internet. By interacting through the video conference, the remote classroom is able to ask for changes in the reactor power or settings of the detection systems. They can also ask for the broadcast of some particular information. At the guest institution, the information is displayed in two parts or screens, as shown in the Figure 3. Concerning the interaction with - and the feedback from - the remote classroom, the camera of the video system in the remote classroom is used to ensure the contact between the trainees and the lecturer and reactor operators. Thus, the Internet Reactor Laboratory is complementary to the on reactor training courses. It allows distant learning, reducing the overall cost of the course when this is necessary. It can efficiently be used for the development of the human resources needed by the nuclear industry and the nuclear programs in countries without research reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prototype Neutron Energy Spectrometer

The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production [ship effect], [a, n] reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The calculation of light element impurity (α, n) yield curves in a PuO 2 matrix and associated specific yield coefficients: Influence of the reaction cross sections

Most of the Pu separated from irradiated commercial nuclear fuel is stored as PuO 2 . The primary quantitative nondestructive measurement technique used to verify the amount of Pu in storage containers is passive neutron correlation counting. An important physical property of the oxide material is the ratio, α, of the rate of (α, n) neutrons produced inside the item to the rate of neutrons produced by spontaneous fission. This ratio influences the precision of the correlated counting method and affects the interpretation of the data because of how it changes both the primary total neutron production rate and the rate of induced fission events taking place inside the item. In addition to the main O(α, n) contribution, additional contributions come from α-particle interactions with light element impurities that are inevitably present. In this work, we calculate specific (α, n) yield coefficients, expressed in units of neutrons per second per gram of α-emitting nuclide per part per million by mass of the specified impurity element distributed in a pure PuO 2 matrix, for some key α-emitting actinides commonly present in reprocessed Pu ( 238–242 Pu+ 241 Am). These coefficients are directly applicable to nuclear safeguards verification work in which the α ratio is often calculated from the Pu-isotopic composition and chemical information obtained by other means. Further, they also provide a convenient up-to-date reference set against which values generated by other methods can be compared. Results are presented for impurities with atomic number from 3 to 17 inclusive, plus K and Fe. In most cases, these coefficients are not expected to change by more than 5%–10% at any time in the future. However, as new data become available, changes as large as 20% may be needed for some targets (e.g., F). The present yield calculations are limited by the general shortage of quality experimental total (α, n) reaction cross section data, which, together with unexplained variation between determinations, means that an objective and coherent evaluation is not possible. The situation is even less satisfactory for the partial differential cross section needed to calculate neutron spectra.

(𝛼, n) reactions↗

Surface roughness and interface width scaling of magnetron sputter deposited Ni/Ti multilayers

Using an indigenously built r.f. magnetron sputtering system, several single layer Ti and Ni films have been deposited at varying deposition conditions. All the samples have been characterized by Grazing Incidence X-ray Reflectivity (GIXR) and Atomic Force Microscopy to estimate their thickness, density, and roughness and a power law dependence of the surface roughness on the film thickness has been established. Subsequently, at optimized deposition condition of Ti and Ni, four Ni/Ti multilayers of 11-layer, 21-layer, 31-layer, and 51-layer having different bilayer thickness have been deposited. The multilayer samples have been characterized by GIXR and neutron reflectivity measurements and the experimental data have been fitted assuming an appropriate sample structure. A power law correlation between the interface width and bilayer thickness has been observed for the multilayer samples, which was explained in the light of alternate roughening/smoothening of multilayers and assuming that at the interface the growth “restarts” every time.

36 MATERIALS SCIENCE↗

SU-F-BRE-11: Neutron Measurements Around the Varian TrueBeam Linac

Purpose: With the emergence of flattening filter free (FFF) photon beams, several authors have noted many advantages to their use. One such advantage is the decrease in neutron production by photonuclear reactions in the linac head. In the present work we investigate the reduction in neutrons from a Varian TrueBeam linac using the Nested Neutron Spectrometer (NNS, Detec). The neutron spectrum, total fluence and source strength were measured and compared for 10 MV with and without flattening filter and the effect of moderation by the room and maze was studied for the 15 MV beam. Methods: The NNS, similar to traditional Bonner sphere detectors but operated in current mode, was used to measure the neutron fluence and spectrum. The NNS was validated for use in high dose rate environments using Monte Carlo simulations and calibrated at NIST and NRC Canada. Measurements were performed at several positions within the treatment room and maze with the linac jaws closed to maximize neutron production. Results: The measurements showed a total fluence reduction between 35-40% in the room and maze when the flattening filter was removed. The neutron source strength Qn was calculated from in-room fluence measurements and was found to be 0.042 × 10{sup 2} n/Gy, 0.026 × 10{sup 2} n/Gy and 0.59 × 101{sup 2} n/Gy for the 10 MV, the 10 MV FFF and 15 MV beams, respectively. We measured ambient equivalent doses of 11 mSv/hr, 7 mSv/hr and 218 mSv/hr for the 10 MV, 10 MV FFF and 15 MV by the head. Conclusion: Our measurements revealed a decrease in total fluence, neutron source strength and equivalent dose of approximately 35-40% across the treatment room for the FFF compared to FF modes. This demonstrates, as expected, that the flattening filter is a major component of the neutron production for the TrueBeam. The authors greatly acknowledge support form the Canadian Nuclear Commission and the Natural Sciences and Engineering Research Council of Canada through the CREATE program. Co-authors Dubeau and Witharana are employees of Detec (Gatineau, Quebec), manufacturer of the Nested Neutron Spectrometer.

07 ISOTOPE AND RADIATION SOURCES↗

Measuring neutron spectra in radiotherapy using the nested neutron spectrometer

Purpose: Out-of-field neutron doses resulting from photonuclear interactions in the head of a linear accelerator pose an iatrogenic risk to patients and an occupational risk to personnel during radiotherapy. To quantify neutron production, in-room measurements have traditionally been carried out using Bonner sphere systems (BSS) with activation foils and TLDs. In this work, a recently developed active detector, the nested neutron spectrometer (NNS), was tested in radiotherapy bunkers. Methods: The NNS is designed for easy handling and is more practical than the traditional BSS. Operated in current-mode, the problem of pulse pileup due to high dose-rates is overcome by measuring current, similar to an ionization chamber. In a bunker housing a Varian Clinac 21EX, the performance of the NNS was evaluated in terms of reproducibility, linearity, and dose-rate effects. Using a custom maximum-likelihood expectation–maximization algorithm, measured neutron spectra at various locations inside the bunker were then compared to Monte Carlo simulations of an identical setup. In terms of dose, neutron ambient dose equivalents were calculated from the measured spectra and compared to bubble detector neutron dose equivalent measurements. Results: The NNS-measured spectra for neutrons at various locations in a treatment room were found to be consistent with expectations for both relative shape and absolute magnitude. Neutron fluence-rate decreased with distance from the source and the shape of the spectrum changed from a dominant fast neutron peak near the Linac head to a dominant thermal neutron peak in the moderating conditions of the maze. Monte Carlo data and NNS-measured spectra agreed within 30% at all locations except in the maze where the deviation was a maximum of 40%. Neutron ambient dose equivalents calculated from the authors’ measured spectra were consistent (one standard deviation) with bubble detector measurements in the treatment room. Conclusions: The NNS may be used to reliably measure the neutron spectrum of a radiotherapy beam in less than 1 h, including setup and data unfolding. This work thus represents a new, fast, and practical method for neutron spectral measurements in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Magnetic order in the van der Waals magnet VCl 3

Here, we investigated the structural and magnetic properties of single-crystalline VCl 3 , a newly synthesized member of the vanadium trihalide family. High-quality single crystals were grown by the chemical vapor transport method, and their behavior was characterized using neutron diffraction and thermodynamic measurements. We show that VCl 3 crystallizes in the BiI 3 -type structure at room temperature and undergoes a structural phase transition at 𝑇 𝑆 = 103.7⁢(5)⁢K that lowers the lattice symmetry, followed by a zigzag antiferromagnetic order with a propagation vector 𝑘 = (0,0.5,1) below 𝑇 𝑁 = 21.8⁢(1)⁢K. Neutron diffraction experiments indicate that the ordered moments are canted by approximately 21° away from the 𝑐 axis toward the 𝑎 axis, yielding a total moment of approximately 1.09⁢(2) ⁢𝜇 B /V 3+ . Field-dependent magnetization along the 𝑐 axis exhibits a half magnetization plateau, indicative of a field-stabilized fractional state. These results establish VCl 3 as a new platform for exploring structural transitions, anisotropic magnetism, and field-induced phases in vanadium-based honeycomb magnets.

Kao, Zeyu [Fudan Univ., Shanghai (China)]↗

Neutron Detection via the Cherenkov Effect

We have incorporated neutron-absorbing elements in transparent, nonscintillating glasses and used the Cherenkov effect to convert neutron-induced beta-gamma radiation directly into light. Use of the Cherenkov effect requires glasses with a high index of refraction (to lower the threshold and increase the number of Cherenkov photons) and neutron absorbers resulting in radioactive products emitting high-energy beta or gamma radiation. In this paper, we present a brief description of the requirements for developing efficient Cherenkov-based neutron detectors, show the results of measurements of the response of representative samples to thermal and fast neutron fluxes, and give the results of a calculation of the expected response of a detector to a moderated fission spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strategies to minimize the influence of instrumental bias in neutron scattering

The influence of instrumental bias on neutron scattering measurements that involve a change between two experimental states is studied analytically and computationally. Different sources of bias were applied to an unperturbed (perfect) data stream. The influence of bias on the measurement was quantified and means to mitigate it is demonstrated. We find frequent changes of state are better than fewer, and evenly alternating between changes of state is often unwise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the scintillation mechanism in a pressurized {sup 4}He fast neutron detector using pulse shape fitting

An empirical investigation of the scintillation mechanism in a pressurized {sup 4}He gas fast neutron detector was conducted using pulse shape fitting. Scintillation signals from neutron interactions were measured and averaged to produce a single generic neutron pulse shape from both a {sup 252}Cf spontaneous fission source and a (d,d) neutron generator. An expression for light output over time was then developed by treating the decay of helium excited states in the same manner as the decay of radioactive isotopes. This pulse shape expression was fitted to the measured neutron pulse shape using a least-squares optimization algorithm, allowing an empirical analysis of the mechanism of scintillation inside the {sup 4}He detector. A further understanding of this mechanism in the {sup 4}He detector will advance the use of this system as a neutron spectrometer. For {sup 252}Cf neutrons, the triplet and singlet time constants were found to be 970 ns and 686 ns, respectively. For neutrons from the (d,d) generator, the time constants were found to be 884 ns and 636 ns. Differences were noted in the magnitude of these parameters compared to previously published data, however the general relationships were noted to be the same and checked with expected trends from theory. Of the excited helium states produced from a {sup 252}Cf neutron interaction, 76% were found to be born as triplet states, similar to the result from the neutron generator of 71%. The two sources yielded similar pulse shapes despite having very different neutron energy spectra, validating the robustness of the fits across various neutron energies.

36 MATERIALS SCIENCE↗

Damage development in neutron-irradiated concrete in a test reactor: Hygro-thermal and mechanical simulations

This paper reports the development of a 3D mesoscale hygro-thermal-mechanical simulation approach to predict damage in concrete irradiated in a test reactor. This framework, developed in MOOSE, considers the effects of elevated temperature, moisture content, and high neutron fluence (energy threshold, E > 0.1 MeV) on the mortar and aggregates separately. The first-stage simulation implements hygro-thermal analysis to determine the temperature and RH inside the specimen as a function of imposed radiation energy. These are used as inputs to the second stage, which considers radiation-induced volumetric expansion (RIVE) of aggregates, and creep, shrinkage, and stress-strain response of mortar to predict the expansion, stresses, and damage in specimens made using different coarse aggregates and subjected to different irradiation times. The irradiation time-dependent damage in the mortar is expressed using an isotropic damage parameter. This multi-physics model serves as a predictive tool for damage quantification in concrete due to neutron irradiation.

36 MATERIALS SCIENCE↗