Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

In-situ Transmission Electron Microscopy and Spectroscopy Studies of Interfaces in Li-ion Batteries: Challenges and Opportunities

The critical challenge facing the lithium ion battery development is the basic understanding of the structural evolution during the cyclic operation of the battery and the consequence of the structural evolution on the properties of the battery. Although transmission electron microscopy (TEM) and spectroscopy have been evolved to a stage such that it can be routinely used to probe into both the structural and chemical composition of the materials with a spatial resolution of a single atomic column, a direct in-situ TEM observation of structural evolution of the materials in lithium ion battery during the dynamic operation of the battery has never been reported. This is related to three factors: high vacuum operation of a TEM; electron transparency requirement of the region to be observed, and the difficulties dealing with the liquid electrolyte of lithium ion battery. In this paper, we report the results of exploring the in-situ TEM techniques for observation of the interface in lithium ion battery during the operation of the battery. A miniature battery was fabricated using a nanowire and an ionic liquid electrolyte. The structure and chemical composition of the interface across the anode and the electrolyte was studied using TEM imaging, electron diffraction, and electron energy loss spectroscopy. In addition, we also explored the possibilities of carrying out in-situ TEM studies of lithium ion batteries with a solid state electrolyte.

74 ATOMIC AND MOLECULAR PHYSICS↗

In situ electrochemical scanning/transmission electron microscopy of electrode–electrolyte interfaces

Insights into the dynamics of electrochemical processes are critically needed to improve our fundamental understanding of electron, charge, and mass transfer mechanisms and reaction kinetics that influence a broad range of applications, from the functionality of electrical energy-storage and conversion devices (e.g., batteries, fuel cells, and supercapacitors), to materials degradation issues (e.g., corrosion and oxidation), and materials synthesis (e.g., electrodeposition). To unravel these processes, in situ electrochemical scanning/transmission electron microscopy (ec-S/TEM) was developed to permit detailed site-specific characterization of evolving electrochemical processes that occur at electrode–electrolyte interfaces in their native electrolyte environment, in real time and at high-spatial resolution. This approach utilizes “closed-form” microfabricated electrochemical cells that couple the capability for quantitative electrochemical measurements with high spatial and temporal resolution imaging, spectroscopy, and diffraction. Here, we review the state-of-the-art instrumentation for in situ ec-S/TEM and how this approach has resulted in new observations of electrochemical processes.

25 ENERGY STORAGE↗

Resolving intragranular stress fields in plastically deformed titanium using point-focused high-energy diffraction microscopy

Abstract The response of a polycrystalline material to a mechanical load depends not only on the response of each individual grain, but also on the interaction with its neighbors. These interactions lead to local, intragranular stress concentrations that often dictate the initiation of plastic deformation and consequently the macroscopic stress–strain behavior. However, very few experimental studies have quantified intragranular stresses across bulk, three-dimensional volumes. In this work, a synchrotron X-ray diffraction technique called point-focused high-energy diffraction microscopy (pf-HEDM) is used to characterize intragranular deformation across a bulk, plastically deformed, polycrystalline titanium specimen. The results reveal the heterogenous stress distributions within individual grains and across grain boundaries, a stress concentration between a low and high Schmid factor grain pair, and a stress gradient near an extension twinning boundary. This work demonstrates the potential for the future use of pf-HEDM for understanding the local deformation associated with networks of grains and informing mesoscale models. Graphical abstract

36 MATERIALS SCIENCE↗

Scanning Electron Microscopy and X-Ray Diffraction Analysis of Tank 18 Samples

The F-Area Tank Farm (FTF) Performance Assessment (PA) utilizes waste speciation in the waste release model used in the FTF fate and transport modeling. The waste release modeling associated with the residual plutonium in Tank 18 has been identified as a primary contributor to the Tank 18 dose uncertainty. In order to reduce the uncertainty related to plutonium in Tank 18, a better understanding of the plutonium speciation in the Tank 18 waste (including the oxidation state and stoichiometry) is desired. Savannah River National Laboratory (SRNL) utilized Scanning Electron Microscopy (SEM) and X-ray Diffraction (XRD) to analyze Tank 18 samples to provide information on the speciation of plutonium in the waste material. XRD analysis of the Tank 18 samples did not identify any plutonium mineral phases in the samples. These indicates the crystalline mineral phases of plutonium are below the detection limits of the XRD method or that the plutonium phase(s) lack long range order and are present as amorphous or microcrystalline solids. SEM analysis of the Tank 18 samples did locate particles containing plutonium. The plutonium was found as small particles, usually <1 μm but ranging up to several micrometers in diameter, associated with particles of an iron matrix and at low concentration in other elemental matrices. This suggests the plutonium has an affinity for the iron matrix. Qualitatively, the particles of plutonium found in the SEM analysis do not appear to account for all of the plutonium in the sample based on concentrations determined from the chemical analysis of the Tank 18 samples. This suggests that plutonium is also distributed throughout the solids in low concentrations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of Image Quality Evaluation Techniques for Transmission X-Ray Microscopy

Beamline 6-2c at Stanford Synchrotron Radiation Lightsource (SSRL) is capable of Transmission X-ray Microscopy (TXM) at 30 nm resolution. Raw images from the microscope must undergo extensive image processing before publication. Since typical data sets normally contain thousands of images, it is necessary to automate the image processing workflow as much as possible, particularly for the aligning and averaging of similar images. Currently we align images using the 'phase correlation' algorithm, which calculates the relative offset of two images by multiplying them in the frequency domain. For images containing high frequency noise, this algorithm will align noise with noise, resulting in a blurry average. To remedy this we multiply the images by a Gaussian function in the frequency domain, so that the algorithm ignores the high frequency noise while properly aligning the features of interest (FOI). The shape of the Gaussian is manually tuned by the user until the resulting average image is sharpest. To automatically optimize this process, it is necessary for the computer to evaluate the quality of the average image by quantifying its sharpness. In our research we explored two image sharpness metrics, the variance method and the frequency threshold method. The variance method uses the variance of the image as an indicator of sharpness while the frequency threshold method sums up the power in a specific frequency band. These metrics were tested on a variety of test images, containing both real and artificial noise. To apply these sharpness metrics, we designed and built a MATLAB graphical user interface (GUI) called 'Blur Master.' We found that it is possible for blurry images to have a large variance if they contain high amounts of noise. On the other hand, we found the frequency method to be quite reliable, although it is necessary to manually choose suitable limits for the frequency band. Further research must be performed to design an algorithm which automatically selects these parameters.

99 GENERAL AND MISCELLANEOUS↗

U-10Mo Sample Preparation and Examination using Optical and Scanning Electron Microscopy

The purpose of this document is to provide guidelines to prepare specimens of uranium alloyed with 10 weight percent molybdenum (U-10Mo) for optical metallography and scanning electron microscopy. This document also provides instructions to set up an optical microscope and a scanning electron microscope to analyze U-10Mo specimens and to obtain the required information.

36 MATERIALS SCIENCE↗

U-10Mo Sample Preparation and Examination using Optical and Scanning Electron Microscopy

The purpose of this document is to provide guidelines to prepare specimens of uranium alloyed with 10 weight percent molybdenum (U-10Mo) for optical metallography and scanning electron microscopy. This document also provides instructions to set up an optical microscope and a scanning electron microscope to analyze U-10Mo specimens and to obtain the required information.

36 MATERIALS SCIENCE↗

Microscopic subsurface characterization of layered magnetic materials using magnetic resonance force microscopy

This project resulted in the following accomplishments: 1) The invention of scanned probe ferromagnetic resonance microscopy. Upon implementation and refinement this approach was used to measure static and dynamic magnetic resonance properties of ferromagnets with an unprecedented combination of spectral and spatial resolution. 2) Demonstration and study of spin pumping in a pristine ferromagnet across a boundary defined entirely by a magnetic field gradient, and so free of materials discontinuities. 3) First demonstrated highly efficient dynamic spin injection from Y 3 Fe 5 O 12 (YIG) into NiO, an antiferromagnetic (AF) insulator and robust spin propagation in AF NiO over distances up to 100-nm thickness; both spin injection and spin transport are mediated by the AF spin correlations. 4) Demonstration of exceptionally high efficiency conversion of spin current to charge current achieved in spin pumping from the dynamic magnetization of a ferromagnetic insulator into a variety of adjacent metal films. 5) Seminal study of the nature of spin-orbit coupling in d-electron metals that revealed the dominant sensitivity of the d-orbital moment to the d-electron count and revealing the important roles of both d-electron configuration and atomic number in the physics of the spin Hall effect. 6) Demonstration of observation of FMR by means of optically-detected NV diamond relaxometry that provided a highly sensitive, spatially resolved FMR detection method and revealed spin pumping across 100-nm length scales by means of dipolar coupling. 7) Using magnetic field localization, developed for FMR imaging, demonstrated a novel approach to discretizing spin wave modes to improve the characteristics of auto-oscillators driven by pure spin currents produced by the spin Hall effect. 8) We demonstrated large spin pumping signals from propagating high wavevector spinwaves in thin film YIG find that the spin pumping efficiency was insensitive to wavevector thus emphasizing the promise of thin YIG films for spinwave-based spintronics by allowing for predictable down-scaling of device dimensions and enabling a broad range of operational frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced Microscopy and Spectroscopy for Probing and Optimizing Electrode-Electrolyte Interphases in High Energy Lithium Batteries (Final Scientific/Technical Report)

The earliest developed LiCoO 2 layered oxide cathode material sparked the development of other layered cathode materials, dominating the positive electrode materials for lithium ion batteries. Within the practical operating conditions of today, the current generation layered oxide materials do not meet the future energy storage demands of 350 Wh kg -1 at cell level. Li-rich layered oxide (LRLO) materials have the potential to meet the high energy demands. Unlike the classical layered oxides, LRLO materials exhibit capacities that go beyond conventional topotactic mechanistic theoretical values. Despite its high capacities, this material has several challenges (voltage fading, structural instability, sluggish kinetics, cathode electrolyte interphase instability, etc.) that must be overcome in order to reach commercialization. In the past five years, our research group has made great progress on developing advanced characterization techniques coupled with atomic scale modeling to properly characterize the dynamic phenomena that govern the performance limitations of LRLO materials. Furthermore, our efforts have guided the material synthesis and surface modification to improve capacity retention. By carefully controlling the oxygen activities through the creation of uniform oxygen vacancies, we were able to avoid structural decomposition in LRLO. Our materials deliver a discharge capacity as high as 306 mAh g -1 with an initial coulombic efficiency of 90.6%. Furthermore, they do not exhibit obvious capacity decay with a reversible capacity over 300 mAh g -1 after 100 cycles at 0.1 C-rate. Our approach demonstrates the critical needs for advanced diagnosis and characterization. It is through the in-depth understanding of these high voltage cathode materials at atomistic and molecular level and their dynamic changes during the operation of batteries; we can successfully formulate strategies to further optimize this class of cathode materials, especially for the voltage instabilities. The diagnostic tools developed here can also be leveraged to study anode materials such as Li metal anode. The challenge of probing Li metal is the low dose tolerance (high beam sensitivity) of Li metal. We will have to apply cryogenic method (low-temperature) and low-dose electron microscopy and specialized camera to enable the characterization of the lithium metal.

25 ENERGY STORAGE↗

Data Report: High-Resolution Microscopy Images of Sediments from Green Canyon Block 955, Gulf of Mexico

We took Leica microscopy images of sediment samples acquired at Holes H002 (4 samples) and H005 (1 sample) during the UT-GOM2-1 Expedition in Green Canyon Block 955, in the northern Gulf of Mexico. A total of 37 images were acquired. The images document a prevalence of spherical conchoidal minerals, cleavage planes typical of feldspar or mica, and black fragmented minerals which stand out from the surrounding matrix. Drilling mud intrusion is thought to contribute to a grey metallic matrix observed across multiple samples.

03 NATURAL GAS↗

Seeing is Believing: Autonomous Microscopy and the Data Revolution in Materials Science

This presentation explores the transformative potential of autonomous electron microscopy and artificial intelligence (AI) in accelerating materials science discovery, particularly for energy applications and materials operating in extreme environments. We discuss pioneering self-driving laboratories at NREL designed to intelligently probe material synthesis and degradation across multiple scales, aiming to rapidly bridge the gap between atomic-level understanding and the development of high-performance, reliable materials. Utilizing advanced machine learning techniques, such as few-shot learning and multimodal analysis integrating imaging and spectroscopy, we demonstrate methods to extract actionable descriptors for material behavior, quantify complex microstructural evolution, and statistically link synthesis parameters to defect populations. This AI-driven approach promises to accelerate the creation of predictive materials tailored for specific missions, enabling faster development cycles and enhanced material assurance.

36 MATERIALS SCIENCE↗

Seeing is Believing: Autonomous Microscopy and the Data Revolution in Materials Science

This presentation explores the transformative potential of autonomous electron microscopy and artificial intelligence (AI) in accelerating materials science discovery, particularly for energy applications and materials operating in extreme environments. We discuss pioneering self-driving laboratories at NREL designed to intelligently probe material synthesis and degradation across multiple scales, aiming to rapidly bridge the gap between atomic-level understanding and the development of high-performance, reliable materials. Utilizing advanced machine learning techniques, such as few-shot learning and multimodal analysis integrating imaging and spectroscopy, we demonstrate methods to extract actionable descriptors for material behavior, quantify complex microstructural evolution, and statistically link synthesis parameters to defect populations. This AI-driven approach promises to accelerate the creation of predictive materials tailored for specific missions, enabling faster development cycles and enhanced material assurance.

97 MATHEMATICS AND COMPUTING↗

The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes

Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.

97 MATHEMATICS AND COMPUTING↗

Probing Dynamic Phase Changes in Electrochemical Systems with Cryogenic and in Situ Analytical Electron Microscopy (Final Technical Report)

In this project, we focus on the advancement of our newly developed, unique in situ and cryogenic analytical electron microscopy (AEM) techniques and the development of additional high-end capabilities to quantitatively elucidate the mechanisms of resistive state changes in solid-state electrochemical materials for non-volatile, neuromorphic memory. The objectives of the proposed research are (1) to characterize and elucidate the mechanisms by which electronic state changes occur in various solid-state devices to build guiding principles for electrochemically activated smart materials; (2) to advance our understanding of such mechanisms by coupling cryogenic and in situ techniques to control kinetics of the observed mechanisms while mitigating probe-induced damage; and (3) to utilize additional advanced techniques including electron-beam induced current and quantum mechanical simulations in order to identify the underlying fundamental science of such processes, including roles of defect formation and its effect on phase nucleation, as well as dynamics of these processes in the electrochemical systems at the nanometer scale.

25 ENERGY STORAGE↗

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION↗

IV Administered Gadodiamide Enters the Lumen of the Prostatic Glands: X-Ray Fluorescence Microscopy Examination of a Mouse Model

In our objective, we descibe how dynamic contrast-enhanced MRI (DCE-MRI) has become a standard component of multiparametric protocols for MRI examination of the prostate, and its use is incorporated into current guidelines for prostate MRI examination. Analysis of DCE-MRI data for the prostate is usually based on the distribution of gadolinium-based agents, such as gadodiamide, into two well-mixed compartments, and it assumes that gadodiamide does not enter into the glandular lumen. However, this assumption has not been directly tested. The purpose of this study was to use x-ray fluorescence microscopy (XFM) imaging in situ to measure the concentration of gadodiamide in the epithelia and lumens of the prostate of healthy mice after IV injection of the contrast agent. For our materials and methods, six C57Bl6 male mice (age, 28 weeks) were sacrificed 10 minutes after IV injection of gadodiamide (0.13 mmol/kg), and three mice were sacrificed after saline injection. Prostate tissue samples obtained from each mouse were harvested and frozen; 7-μm-thick slices were sectioned for XFM imaging, and adjacent 5-μm-thick slices were sectioned for H and E staining. Elemental concentrations were determined from XFM images. Our results show mean (± SD) baseline concentration of gadolinium of 0.01 ± 0.01 mM was determined from XFM measurements of prostatic tissue samples when no gadodiamide was administered, and it was used to determine the measurement error. When gadodiamide was added, the mean concentrations of gadolinium in the epithelia and lumens in 32 prostatic glands from six mice were 1.00 ± 0.13 and 0.36 ± 0.09 mM, respectively. In conclusion, our data suggest that IV administration of gadodiamide results in uptake of contrast agent by the glandular lumens of the mouse prostate. We were able to quantitatively determine gadodiamide distributions in mouse prostatic epithelia and lumens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗