Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Learning statistical correlation for fast prostate registration in image-guided radiotherapy

Purpose: In adaptive radiation therapy of prostate cancer, fast and accurate registration between the planning image and treatment images of the patient is of essential importance. With the authors' recently developed deformable surface model, prostate boundaries in each treatment image can be rapidly segmented and their correspondences (or relative deformations) to the prostate boundaries in the planning image are also established automatically. However, the dense correspondences on the nonboundary regions, which are important especially for transforming the treatment plan designed in the planning image space to each treatment image space, are remained unresolved. This paper presents a novel approach to learn the statistical correlation between deformations of prostate boundary and nonboundary regions, for rapidly estimating deformations of the nonboundary regions when given the deformations of the prostate boundary at a new treatment image. Methods: The main contributions of the proposed method lie in the following aspects. First, the statistical deformation correlation will be learned from both current patient and other training patients, and further updated adaptively during the radiotherapy. Specifically, in the initial treatment stage when the number of treatment images collected from the current patient is small, the statistical deformation correlation is mainly learned from other training patients. As more treatment images are collected from the current patient, the patient-specific information will play a more important role in learning patient-specific statistical deformation correlation to effectively reflect prostate deformation of the current patient during the treatment. Eventually, only the patient-specific statistical deformation correlation is used to estimate dense correspondences when a sufficient number of treatment images have been acquired from the current patient. Second, the statistical deformation correlation will be learned by using a multiple linear regression (MLR) model, i.e., ridge regression (RR) model, which has the best prediction accuracy than other MLR models such as canonical correlation analysis (CCA) and principal component regression (PCR). Results: To demonstrate the performance of the proposed method, we first evaluate its registration accuracy by comparing the deformation field predicted by our method with the deformation field estimated by the thin plate spline (TPS) based correspondence interpolation method on 306 serial prostate CT images of 24 patients. The average predictive error on the voxels around 5 mm of prostate boundary is 0.38 mm for our method of RR-based correlation model. Also, the corresponding maximum error is 2.89 mm. We then compare the speed for deformation interpolation by different methods. When considering the larger region of interest (ROI) with the size of 512 x 512 x 61, our method takes 24.41 seconds to interpolate the dense deformation field while TPS method needs 6.7 minutes; when considering a small ROI (surrounding prostate) with size of 112 x 110 x 93, our method takes 1.80 seconds, while TPS method needs 25 seconds. Conclusions: Experimental results show that the proposed method can achieve much faster registration speed yet with comparable registration accuracy, compared to the TPS-based correspondence (or deformation) interpolation approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sci—Sat AM: Stereo — 05: The Development of Quality Assurance Methods for Trajectory based Cranial SRS Treatments

The goal of this work was to develop and validate non-planar linac beam trajectories defined by the dynamic motion of the gantry, couch, jaws, collimator and MLCs. This was conducted on the Varian TrueBeam linac by taking advantage of the linac's advanced control features in a non-clinical mode (termed developers mode). In this work, we present quality assurance methods that we have developed to test for the positional and temporal accuracy of the linac's moving components. The first QA method focuses on the coordination of couch and gantry. For this test, we developed a cylindrical phantom which has a film insert. Using this phantom we delivered a plan with dynamic motion of the couch and gantry. We found the mean absolute deviation of the entrance position from its expected value to be 0.5mm, with a standard deviation of 0.5mm. This was within the tolerances set by the machine's mechanical accuracy and the setup accuracy of the phantom. We also present an altered picket fence test which has added dynamic and simultaneous rotations of the couch and the collimator. While the test was shown to be sensitive enough to discern errors 1° and greater, we were unable to identify any errors in the coordination of the linacs collimator and couch. When operating under normal conditions, the Varian TrueBeam linac was able to pass both tests and is within tolerances acceptable for complex trajectory based treatments.

07 ISOTOPE AND RADIATION SOURCES↗

A position-aware linear solid constitutive model for peridynamics

A position-aware linear solid (PALS) peridynamic constitutive model is proposed for isotropic elastic solids. The PALS model addresses problems that arise, in ordinary peridynamic material models such as the linear peridynamic solid (LPS), due to incomplete neighborhoods near the surface of a body. We improved model behavior in the vicinity of free surfaces through the application of two influence functions that correspond, respectively, to the volumetric and deviatoric parts of the deformation. Furthermore, the model is position-aware in that the influence functions vary over the body and reflect the proximity of each material point to free surfaces. Demonstration calculations on simple benchmark problems show a sharp reduction in error relative to the LPS model.

36 MATERIALS SCIENCE↗

Numerical Analysis of Fixed Point Algorithms in the Presence of Hardware Faults

The exponential growth of computational power of the extreme scale machines over the past few decades has led to a corresponding decrease in reliability and a sharp increase of the frequency of hardware faults. Our research focuses on the mathematical challenges presented by the silent hardware faults. i.e., faults that can perturb the result of computations in an inconspicuous way. Using the approach of selective reliability we present an analytic fault mode that can be used to study the resilience properties of a numerical algorithm. We apply our approach to the classical fixed point iteration and demonstrate that in the presence of hardware faults, the classical method fails to converge in expectation. We preset a modified resilient algorithm that detects and rejects faults resulting in error with large magnitude, while small faults are negated by the natural self-correcting properties of the algorithm. We show that our method is convergent (in first and second statistical moments) even in the presence of silent hardware faults.

algorithmic resilience↗

Quantum Solver Using Singular Value Decomposition for Computational Fluid Dynamics

Numerical solutions for fluid flow problems are challenging and have been focus of Computational Fluid Dynamics (CFD) research for past several decades. The advent of quantum computing promises exponential speedup in comparison to existing classical methods and alleviate computational constraints posed by CFD problems. Although solutions for most problems of interest in fluid dynamics using quantum computing are distant, recent advances in algorithms, software and hardware provide a path towards realizing this goal. Quantum linear solver algorithms (QLSA) such as Harrow–Hassidim–Lloyd (HHL) and Variational Quantum Linear Solver (VQLS) have been successfully implemented to solve for canonical problems such as Hele-Shaw flow. However, these algorithms still suffer to scale and address problems with ill-conditioned Jacobians. In the current paper, we alleviate these restrictions with a new quantum solver based on Singular Value Decomposition (SVD) and simulate flow past a 2D cylinder. The fidelity of the SVD based quantum solver in predicting the flow past 2D cylinder is computed along with an assessment of errors. Classical and quantum solutions for the flow are compared for different resolutions. Finally, we discuss variation in the solutions based on number of shots used.

Gottiparthi, Kalyan [ORNL] (ORCID:0000000213540255↗

TH-C-12A-08: New Compact 10 MV S-Band Linear Accelerator: 3D Finite-Element Design and Monte Carlo Dose Simulations

Purpose: To design a new compact S-band linac waveguide capable of producing a 10 MV x-ray beam, while maintaining the length (27.5 cm) of current 6 MV waveguides. This will allow higher x-ray energies to be used in our linac-MRI systems with the same footprint. Methods: Finite element software COMSOL Multiphysics was used to design an accelerator cavity matching one published in an experiment breakdown study, to ensure that our modeled cavities do not exceed the threshold electric fields published. This cavity was used as the basis for designing an accelerator waveguide, where each cavity of the full waveguide was tuned to resonate at 2.997 GHz by adjusting the cavity diameter. The RF field solution within the waveguide was calculated, and together with an electron-gun phase space generated using Opera3D/SCALA, were input into electron tracking software PARMELA to compute the electron phase space striking the x-ray target. This target phase space was then used in BEAM Monte Carlo simulations to generate percent depth doses curves for this new linac, which were then used to re-optimize the waveguide geometry. Results: The shunt impedance, Q-factor, and peak-to-mean electric field ratio were matched to those published for the breakdown study to within 0.1% error. After tuning the full waveguide, the peak surface fields are calculated to be 207 MV/m, 13% below the breakdown threshold, and a d-max depth of 2.42 cm, a D10/20 value of 1.59, compared to 2.45 cm and 1.59, respectively, for the simulated Varian 10 MV linac and brehmsstrahlung production efficiency 20% lower than a simulated Varian 10 MV linac. Conclusion: This work demonstrates the design of a functional 27.5 cm waveguide producing 10 MV photons with characteristics similar to a Varian 10 MV linac.

07 ISOTOPE AND RADIATION SOURCES↗

Benchmark calculations of radiative forcing by greenhouse gases

Changes in concentrations of greenhouse gases lead to changes in radiative fluxes throughout the atmosphere. The value of this change, the instantaneous radiative forcing, varies across climate models, due partly to differences in the distribution of clouds, humidity, and temperature across models, and partly due to errors introduced by approximate treatments of radiative transfer. This paper describes an experiment within the Radiative Forcing Model Intercomparision Project that uses benchmark calculations made with line–by–line models to identify parameterization error in the representation of absorption and emission by greenhouse gases. Clear–sky instantaneous forcing by greenhouse gases is computed using a set of 100 profiles, selected from a re–analysis of present–day conditions, that represent the global annual mean forcing from pre–industrial times to the present–day with sampling errors of less than 0.01 W m –2 . Six contributing line–by–line models agree in their estimate of this forcing to within 0.025 W m –2 while even recently–developed parameterizations have typical errors four or more times larger, suggesting both that the samples reveal true differences among line–by–line models and that parameterization error will be readily identifiable. Agreement among line–by–line models is better in the longwave than in the shortwave where differing treatments of the water vapor vapor continuum affect estimates of forcing by carbon dioxide and methane. The impacts of clouds on instantaneous radiative forcing are estimated from climate model simulations. Here, the adjustment due to stratospheric temperature change by assuming fixed dynamical heating. Adjustments are large only for ozone and for carbon dioxide, for which stratospheric cooling introduces modest non–linearity.

54 ENVIRONMENTAL SCIENCES↗

A density functional theory based approach for predicting melting points of ionic liquids

Accurate prediction of melting points of ILs is important both from the fundamental point of view and from the practical perspective for screening ILs with low melting points and broadening their utilization in a wider temperature range. In this work, we present an ab initio approach to calculating melting points of ILs with known crystal structures and illustrate its application for a series of 11 ILs containing imidazolium/pyrrolidinium cations and halide/polyatomic fluoro-containing anions. The melting point is determined as a temperature at which the Gibbs free energy of fusion is zero. The Gibbs free energy of fusion can be expressed through the use of the Born-Fajans-Haber cycle via the lattice free energy of forming a solid IL from gaseous phase ions and the sum of the solvation free energies of ions comprising IL. Dispersion-corrected density functional theory (DFT) involving (semi)local (PBE-D3) and hybrid exchange-correlation (HSE06-D3) functionals is applied to estimate the lattice enthalpy, entropy, and free energy. The ions solvation free energies are calculated with the SMD-generic-IL solvation model at the M06-2X/6-31+G(d) level of theory under standard conditions. The melting points of ILs computed with the HSE06-D3 functional are in good agreement with the experimental data, with a mean absolute error of 30.5 K and a mean relative error of 8.5%. The model is capable of accurately reproducing the trends in melting points upon variation of alkyl substituents in organic cations and replacement one anion by another. The results verify that the lattice energies of ILs containing polyatomic fluoro-containing anions can be approximated reasonably well using the volume-based thermodynamic approach. However, there is no correlation of the computed lattice energies with molecular volume for ILs containing halide anions. Moreover, entropies of solid ILs follow two different linear relationships with molecular volume for halides and polyatomic fluoro-containing anions. As a result, continuous progress in predicting crystal structures of organic salts with halide anions will be a key factor for successful prediction of melting points with no prior knowledge of the crystal structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solving the Hele–Shaw flow using the Harrow–Hassidim–Lloyd algorithm on superconducting devices: A study of efficiency and challenges

The development of quantum processors for practical fluid flow problems is a promising yet distant goal. Recent advances in quantum linear solvers have highlighted their potential for classical fluid dynamics. In this study, we evaluate the Harrow–Hassidim–Lloyd (HHL) quantum linear systems algorithm (QLSA) for solving the idealized Hele–Shaw flow. Our focus is on the accuracy and computational cost of the HHL solver, which we find to be sensitive to the condition number, scaling exponentially with problem size. This emphasizes the need for preconditioning to enhance the practical use of QLSAs in fluid flow applications. Moreover, we perform shots-based simulations on quantum simulators and test the HHL solver on superconducting quantum devices, where noise, large circuit depths, and gate errors limit performance. Error suppression and mitigation techniques improve accuracy, suggesting that such fluid flow problems can benchmark noise mitigation efforts. Finally, our findings provide a foundation for future, more complex application of QLSAs in fluid flow simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Density weighted angular redshift fluctuations: a new cosmological observable

We propose the use of angular fluctuations in the galaxy redshift field as a new way to extract cosmological information in the Universe. This new probe $\delta z (\hat{\mathbf {n}})$ consists of the statistics of sky maps built by projecting redshifts under a Gaussian window of width σz centred upon a redshift zobs, and weighted by the galaxy density field. We compute the angular power spectrum of the $\delta z (\hat{\mathbf {n}})$ field in both numerical simulations and in linear perturbation theory. From these, we find that the $\delta z (\hat{\mathbf {n}})$ field (i) is sensitive to the underlying density and peculiar velocity fields; (ii) is highly correlated, at the $\gtrsim 60\, {{\ \rm per\ cent}}$ level, to the line-of-sight projected peculiar velocity field; (iii) for narrow windows (σz < 0.03), it is almost completely uncorrelated to the projected galaxy angular density field under the same redshift window; and (iv) it is largely unaffected by multiplicative and additive systematic errors on the observed number of galaxies that are redshift-independent over ~σz. We conclude that $\delta z (\hat{\mathbf {n}})$ is a simple and robust tomographic measure of the cosmic density and velocity fields, complementary to angular clustering, that will contribute to more complete exploitations of current and upcoming galaxy redshift surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Inverted initial conditions: Exploring the growth of cosmic structure and voids

We introduce and explore “paired” cosmological simulations. A pair consists of an A and B simulation with initial conditions related by the inversion δ A (x,t initial ) = –δ B (x,t initial ) (underdensities substituted for overdensities and vice versa). We argue that the technique is valuable for improving our understanding of cosmic structure formation. The A and B fields are by definition equally likely draws from ΛCDM initial conditions, and in the linear regime evolve identically up to the overall sign. As nonlinear evolution takes hold, a region that collapses to form a halo in simulation A will tend to expand to create a void in simulation B. Applications include (i) contrasting the growth of A-halos and B-voids to test excursion-set theories of structure formation, (ii) cross-correlating the density field of the A and B universes as a novel test for perturbation theory, and (iii) canceling error terms by averaging power spectra between the two boxes. Furthermore, generalizations of the method to more elaborate field transformations are suggested.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-AB-202-01: Daily Lung Tumor Motion Characterization On EPIDs Using a Markerless Tiling Model

Purpose: Tracking lung tumor motion in real time allows for target dose escalation while simultaneously reducing dose to sensitive structures, thus increasing local control without increasing toxicity. We present a novel intra-fractional markerless lung tumor tracking algorithm using MV treatment beam images acquired during treatment delivery. Strong signals superimposed on the tumor significantly reduced the soft tissue resolution; while different imaging modalities involved introduce global imaging discrepancies. This reduced the comparison accuracies. A simple yet elegant Tiling algorithm is reported to overcome the aforementioned issues. Methods: MV treatment beam images were acquired continuously in beam’s eye view (BEV) by an electronic portal imaging device (EPID) during treatment and analyzed to obtain tumor positions on every frame. Every frame of the MV image was simulated by a composite of two components with separate digitally reconstructed radiographs (DRRs): all non-moving structures and the tumor. This Titling algorithm divides the global composite DRR and the corresponding MV projection into sub-images called tiles. Rigid registration is performed independently on tile-pairs in order to improve local soft tissue resolution. This enables the composite DRR to be transformed accurately to match the MV projection and attain a high correlation value through a pixel-based linear transformation. The highest cumulative correlation for all tile-pairs achieved over a user-defined search range indicates the 2-D coordinates of the tumor location on the MV projection. Results: This algorithm was successfully applied to cine-mode BEV images acquired during two SBRT plans delivered five times with different motion patterns to each of two phantoms. Approximately 15000 beam’s eye view images were analyzed and tumor locations were successfully identified on every projection with a maximum/average error of 1.8 mm / 1.0 mm. Conclusion: Despite the presence of strong anatomical signal overlapping with tumor images, this markerless detection algorithm accurately tracks intrafractional lung tumor motions. This project is partially supported by an Elekta research grant.

60 APPLIED LIFE SCIENCES↗

Learning an Algebriac Multrigrid Interpolation Operator Using a Modified GraphNet Architecture

This work, building on previous efforts, develops a suite of new graph neural network machine learning architectures that generate data-driven prolongators for use in Algebraic Multigrid (AMG). Algebraic Multigrid is a powerful and common technique for solving large, sparse linear systems. Its effectiveness is problem dependent and heavily depends on the choice of the prolongation operator, which interpolates the coarse mesh results onto a finer mesh. Previous work has used recent developments in graph neural networks to learn a prolongation operator from a given coefficient matrix. In this paper, we expand on previous work by exploring architectural enhancements of graph neural networks. A new method for generating a training set is developed which more closely aligns to the test set. Asymptotic error reduction factors are compared on a test suite of 3-dimensional Poisson problems with varying degrees of element stretching. Results show modest improvements in asymptotic error factor over both commonly chosen baselines and learning methods from previous work.

97 MATHEMATICS AND COMPUTING↗

Three-dimensional liver motion tracking using real-time two-dimensional MRI

Purpose: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR-Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real-time spatial target localization. This study develops and evaluates a method for tracking three-dimensional (3D) respiratory liver motion in two-dimensional (2D) real-time MRI image series with high temporal and spatial resolution. Methods: The proposed method for 3D tracking in 2D real-time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (or tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real-time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through-plane and in-plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real-time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions. Results: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in-plane motion or estimated indirectly as through-plane motion. The mean peak-to-peak breathing amplitude was 1.6 mm (left-right), 11.0 mm (craniocaudal), and 2.5 mm (anterior-posterior). The position of the watermelon structure was estimated in 2D MRI images with a root-mean-square error of 0.52 mm (in-plane) and 0.87 mm (through-plane). Conclusions: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real-time 3D localization with integrated MR-Linac systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Introductory guide to backgrounds in XPS spectra and their impact on determining peak intensities

Photoelectron and Auger peaks are central to most of the important uses of x-ray photoelectron spectroscopy (XPS), and thus, they receive the most attention in many types of analysis. Quantitative chemical analysis using XPS requires the assessment of the intensities of the photoemission peaks of the elements detected. Determination of peak intensities requires separation of the photoelectron peak signals from the background on which the peaks rest. For the determination of peak area intensities, the background is subtracted from overall signal intensity. The spectral background is also critical when peak fitting is used to determine intensities of overlapping peaks, and the model of background used in this process can impact the results. In addition to the impact on quantitative analysis, information about the depth distribution of elements in the near surface region can often be obtained by visual inspection of the background and quantified using appropriate modeling. Here, this introductory guide provides some basic information about backgrounds in the XPS analysis, describes the types of background models that are commonly used, suggests some of their strengths and weaknesses, and provides examples of their use and misuse. Although the fundamental nature of some components of the background signals in XPS is not understood, indicating that none of the models in use are fully correct and the area is subject to active research, appropriate good practices have been established for most routine analysis. The guide describes good practices, identifies errors that frequently appear in the literature, and uses examples to demonstrate the impacts of background selections on determinations of peak intensities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact video content representation for video coding using low multi-linear tensor rank approximation with dynamic core tensor order

Tensor is a multi-way representation of an entity that is widely used in many applications of mathematics and physics. The wide range of tensor algebra operations attract the researchers of graphical and vision field to identify unique methods for various applications such as segmentation, compression, indexing and so on. In this paper, low multi-linear rank approximation of a tensor is used for decomposition so as to perform compression on a video that is represented as a 4D tensor. Thus, the encoder has blocks for (1) multilinear rank approximation method so as to aid decomposition, (2) sparsity removal of residual data to reduce the required memory storage to a small level, (3) quantization on the sparse less residual data and (4) LZ77 dictionary coding for the video. The decoder uses a tensor reconstruction block along with residual error correction block that reduces loss/error in the reconstructed video. The size of core tensor is an important factor in rank approximation. It is identified at run time depending on the video contents. This size is determined adaptively using Tikhonov’s regularization method. The best value of core tensor size is identified with the corner of L-curve which preserves the video contents from heavy loss/error. Experimental results of the proposed work on comparison with H.264/AVC compression method indicate that the proposed method achieves up to 10% improvement in compression ratio with the least amount of loss and a maximum signal to noise ratio of 0.14. The proposed system gives better compression ratio than H.265 for videos with more number of frames without compromising quality.

97 MATHEMATICS AND COMPUTING↗

THE JETS OF TeV BLAZARS AT HIGHER RESOLUTION: 43 GHz AND POLARIMETRIC VLBA OBSERVATIONS FROM 2005 TO 2009

We present 23 new VLBA images of the six established TeV blazars Markarian 421, Markarian 501, H 1426+428, 1ES 1959+650, PKS 2155-304, and 1ES 2344+514, obtained from 2005 to 2009. Most images were obtained at 43 GHz (7 mm), and they reveal the parsec-scale structures of three of these sources (1ES 1959+650, PKS 2155-304, and 1ES 2344+514) at factors of 2-3 higher resolution than has previously been attained. These images reveal new morphological details, including a high degree of jet bending in the inner milliarcsecond in PKS 2155-304. This establishes strong apparent jet bending on VLBI scales as a common property of TeV blazars, implying viewing angles close to the line of sight. Most of the remaining images map the linear polarization structures at a lower frequency of 22 GHz (1 cm). We discuss the transverse structures of the jets as revealed by the high-frequency and polarimetric imaging. The transverse structures include significant limb brightening in Mrk 421, and 'spine-sheath' structures in the electric vector position angle and fractional polarization distributions in Mrk 421, Mrk 501, and 1ES 1959+650. We use new measured component positions to update measured apparent jet speeds, in many cases significantly reducing the statistical error over previously published results. With the increased resolution at 43 GHz, we detect new components within 0.1-0.2 mas of the core in most of these sources. No motion is apparent in these new components over the time span of our observations, and we place upper limits on the apparent speeds of the components near the core of <2c. From those limits, we conclude that {Gamma}{sub 2} < ({Gamma}{sub 1}){sup 1/2} at {approx}10{sup 5} Schwarzschild radii, where {Gamma}{sub 1} and {Gamma}{sub 2} are the bulk Lorentz factors in the TeV emitting and 43 GHz emitting regions, respectively, assuming that their velocity vectors are aligned.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrating proteomic or transcriptomic data into metabolic models using linear bound flux balance analysis

Abstract Motivation Transcriptomics and proteomics data have been integrated into constraint-based models to influence flux predictions. However, it has been reported recently for Escherichia coli and Saccharomyces cerevisiae, that model predictions from parsimonious flux balance analysis (pFBA), which does not use expression data, are as good or better than predictions from various algorithms that integrate transcriptomics or proteomics data into constraint-based models. Results In this paper, we describe a novel constraint-based method called Linear Bound Flux Balance Analysis (LBFBA), which uses expression data (either transcriptomic or proteomic) to predict metabolic fluxes. The method uses expression data to place soft constraints on individual fluxes, which can be violated. Parameters in the soft constraints are first estimated from a training expression and flux dataset before being used to predict fluxes from expression data in other conditions. We applied LBFBA to E.coli and S.cerevisiae datasets and found that LBFBA predictions were more accurate than pFBA predictions, with average normalized errors roughly half of those from pFBA. For the first time, we demonstrate a computational method that integrates expression data into constraint-based models and improves quantitative flux predictions over pFBA. Availability and implementation Code is available in the Supplementary data available at Bioinformatics online. Supplementary information Supplementary data are available at Bioinformatics online.

Tian, Mingyuan↗