Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Annealing of electron damage in mid-IR transmitting fluoride glass

Damage in ZrF4-BaF2-LaF3 glass induced by high-energy electrons was studied by ESR and optical spectroscopy. An optical absorption band at 314 nm in the irradiated glass annealed rapidly above about 50 C, probably by a second-order reaction at room temperature; the ESR lines annealed very slowly at room temperature.

Bansal, Narottam P.↗

Scene simulation for passive IR systems

The development of large mosaic detector arrays will allow for the construction of staring long wave infrared (LWIR) sensors which can observe large fields of view instantaneously and continuously. In order to evaluate and exercise these new systems, it will be necessary to provide simulated scenes of many moving targets against an infrared clutter background. Researchers are currently developing a projector/screen system. This system is comprised of a mechanical scanner, a diffuse screen, and a miniature blackbody. A prototype of the mechanical scanner, which is comprised of four independently driven scanners, has been designed, fabricated, and evaluated under room and cryogenic vacuum conditions. A large diffuse screen has been constructed and tested for structural integrity under cryogenic/vacuum thermal cycling. Construction techniques have been developed for the fabrication of miniature high-temperature blackbody sources. Finally, a concept has been developed to use this miniature blackbody to produce a spectrally tailorable source.

Holt, J. D.↗

Complementary information between UV and IR for remote sensing of total ozone

When infrared and ultraviolet measurements are available simultaneously with the same field of view, it is possible to minimize some of the errors in measuring the total ozone. The addition of the infrared technique to Total Ozone Mapping Spectrometer (TOMS) operation can aid in getting measurements of ozone in the nighttime and during the polar night. A radiometer with a channel in the window region around 11 microns, a channel in the 9-6 micron O sub 3 band, and three channels in the 15 micron CO sub 2 band should be adequate to retrieve total ozone. Such a radiometer could be designed to do cross track scanning. This combination of ultraviolet and infrared instruments could be flown on a geostationary or polar orbiting satellite.

Cuddapah, Prabhakara↗

Test of IR arrays on the Kuiper Airborne Observatory

NASA's Kuiper Airborne Observatory, which is a C-141 transport aircraft equipped with a 90-cm, all-reflective altazimuth telescope, has been engaged in the Kuiper Infrared Technology Experiment. Attention is presently given to the Experiment's flight series for state-of-the-art two-dimensional, 500-element arrays that use either blocked impurity band or bulk silicon devices. The switched FET readout scheme used on the three arrays flown thus far yields exceptionally low crosstalk. System sensitivities are found to be sufficient for the detection of both pointlike and extended sources; several of each type have been used in staring and scanning experiments.

Russell, R. W.↗

Noise tube sources for the far IR and millimeter region

The radiant output of a noise tube designed for the 90-140-GHz (3.3-2.1-mm) frequency range has been compared with that from mercury lamps over the wavelength region from 0.4 to about 6 mm. Lamellar grating and Michelson Fourier transform spectrometers were used in conjunction with He cooled bolometers of NEP from 10 to the -12th to 10 to the -14th W/sq rt H2 to measure relative spectral irradiance. With this instrumental arrangement, the radiant power emitted by the noise tube was observed to be less than that from a mercury lamp, at least to a 3-mm wavelength, but it produced less source noise than an ac operated mercury lamp. When the noise tube operating current was reduced, the spectral irradiance peak shifted to longer wavelengths.

Moller, K. D.↗

Radiometric calibration of IR Fourier transform spectrometers - Solution to a problem with the High-Resolution Interferometer Sounder

A calibrated Fourier transform spectrometer, known as the High-Resolution Interferometer Sounder (HIS), has been flown on the NASA U-2 research aircraft to measure the infrared emission spectrum of the earth. The primary use - atmospheric temperature and humidity sounding - requires high radiometric precision and accuracy (of the order of 0.1 and 1 C, respectively). To meet these requirements, the HIS instruments, the HIS instrument performs inflight radiometric calibration, using observations of hot and cold blackbody reference sources as the basis for two-point calibrations at each wavenumber. Initially, laboratory tests revealed a calibration problem with brightness temperature errors as large as 15 C between 600 and 900/cm. The symptom of the problem, which occurred in one of the three spectral bands of HIS, was a source-dependent phase response. Minor changes to the calibration equations completely eliminated the anomalous errors. The new analysis properly accounts for the situation in which the phase response for radiance from the instrument itself differs from that for radiance from an external source. The mechanism responsible for the dual phase response of the HIS instrument is identified as emission from the interferometer beam splitter.

Revercomb, Henry E.↗

IR-dust observations of Comet Tempel 2 with CRAF VIMS

Measurement strategies are now being planned for using the Visual and Infrared Mapping Spectrometer (VIMS) to observe the asteroid Hestia, and the nucleus, and the gas and dust in the coma of comet P/Tempel 2 as part of the Comet Rendezvous Asteroid Flyby (CRAF) mission. The spectral range of VIMS will cover wavelengths from 0.35 to 5.2 micrometers, with a spectral resolution of 11 nm from 0.35 to 2.4 micrometers and of 22 nm from 2.4 to 5.2 micrometers. The instantaneous field of view (IFOV) provided by the foreoptics is 0.5 milliradians, and the current design of the instrument provides for a scanning secondary mirror which will scan a swath of length 72 IFOVs. The CRAF high resolution scan platform motion will permit slewing VIMS in a direction perpendicular to the swath. This enables the building of a two dimensional image in any or all wavelength channels. Important measurements of the dust coma will include the onset of early coma activity, the mapping of gas and dust jets and correlations with active nucleus areas, observations of the dust coma from various scattering phase angles, coverage of the low wavelength portion of the thermal radiation, and the 3.4 micrometer hydrocarbon emission. A description of the VIMS instrument is presented.

Combi, Michael R.↗

Detection of parent molecules in the IR spectrum of P/Halley with the IKS-Vega spectrometer

The two spectroscopic channels of the IKS experiment on board the Vega probes were designed for the detection of emission bands of parent molecules and/or cometary dust, in the 2.5 to 5 micrometer range and the 6 to 12 micron range respectively. On Vega 1, the experiment worked successfully, and cometary spectra were recorded at distances from the comet nucleus ranging from about 250,000 to 40,000 km. The field of view was 1 deg and the spectral resolving power was about 50. On Vega 2, no result could be obtained due to a failure of the cryogenic system. The emission spectra obtained are briefly analyzed.

Encrenaz, Therese↗

IR fiber temperature sensing system

Infrared fiber optic pyrometry has become a practical reality using improved strength fluoride glass fibers. The addition of a plastic coating and rugged cabling allows the fibers to be used in the field. A detailed theoretical model of the infrared fiber optic pyrometer (non-contact or radiative thermometer) has been derived and compared with data produced by a prototype fluoride glass fiber radiative thermometer. Excellent agreement was obtained between theory and experiment over a temperature range of 30 to 700 C.

Tran, D. C.↗

Algorithm for automatic atmospheric corrections to visible and near-IR satellite imagery

An algorithm for automatic atmospheric correction of satellite imagery of the earth's surface is proposed which is applicable to low-resolution and high-resolution imagery of land areas. The algorithm is based on the satellite image being corrected and on the climatology of the area, and it requires that some pixels in the image correspond to dense dark vegetation as the surface cover. The algorithm is sensitive to the assumed reflectance of the dense dark vegetation, and the accuracy of the corrected surface reflectance is expected to be + or - 0.01. Using the method, aerosol optical thicknesses were derived from clear and hazy Landsat MSS images in the Washington, D.C. and Chesapeake Bay region, and the results are found to agree well with simultaneous sunphotometer ground measurements.

Kaufman, Yoram J.↗

New advances in non-dispersive IR technology for CO2 detection

This paper discusses new technology developments in CO2 detection using Non-Dispersive Infrared (NDIR) techniques. The method described has successfully been used in various applications and environments. It has exhibited extremely reliable long-term stability without the need of routine calibration. The analysis employs a dual wavelength, differential detection approach with compensating circuitry for component aging and dirt accumulation on optical surfaces. The instrument fails 'safe' and provides the operator with a 'fault' alarm in the event of a system failure. The NDIR analyzer described has been adapted to NASA Space Station requirements.

Small, John W.↗

Estimation of regional surface resistance to evapotranspiration from NDVI and thermal-IR AVHRR data

Infrared surface temperatures from satellite sensors have been used to infer evaporation and soil moisture distribution over large areas. However, surface energy partitioning to latent versus sensible heat changes with surface vegetation cover and water availability. The hypothesis that the relationship between surface temperature and canopy density is sensitivite to seasonal changes in canopy resistance of conifer forests is presently tested. Surface temperature and canopy density were computed for a 20 x 25 km forested region in Montana, from the NOAA/AVHRR for 8 days during the summer of 1985. A forest ecosystem model, FOREST-BGC, simulated canopy resistance for the same period. For all eight days, surface temperatures had high association with canopy density, measured as Normalized Difference Vegetation Index, implying that latent heat exchange is the major cause of spatial variations in surface radiant tmeperatures.

Nemani, Ramakrishna R.↗

IR optical fiber-based noncontact pyrometer for drop tube instrumentation

The design of a two color pyrometer with infrared optical fiber bundles for collection of the infrared radiation is described. The pyrometer design is engineered to facilitate its use for measurement of the temperature of small, falling samples in a microgravity materials processing experiment using a 100 meter long drop tube. Because the samples are small and move rapidly through the field of view of the pyrometer, the optical power budget of the detection system is severly limited. Strategies for overcoming this limitation are discussed.

May, R. G.↗

NCTM workshop splinter session, IR thermal measurement instruments

The splinter session dealing with commercial industrial thermal measurement state-of-the-hardware had a total attendance of 15. Two papers were presented in the splinter session as follows: (1) Development of an Infrared Imaging System for the Surface Tension Driven Convection Experiment, Alexander D. Pline, NASA LeRC; (2) A Space-qualified PtSi Thermal Imaging System, Robert W. Astheimer, Barnes Engineering Div., EDO Corp. In addition a brief description of SPRITE detector technology was presented by Richard F. Leftwich of Magnovox. As anticipated, the discussions were concerned mainly with thermal imaging figures of merit rather than those for point measurement instruments. The need for uniform guidelines whereby infrared thermal imaging instruments could be specified and evaluated was identified as most important, particularly where temperature measurements are required. Presently there are differences in the way different manufacturers present significant performance parameters in their instrument data sheets. Furthermore, the prospective user has difficulty relating these parameters to actual measurement needs, and procedures by which performance can be verified are poorly defined. The current availability of powerful thermal imaging diagnostic software was discussed.

Kaplan, Herbert↗

IR line emission from dense photodissociation regions

The results of the study on the molecular and fine structure line emission, from dense photodissociation regions, are discussed. The work is focused on the prediction of the line emission from CO and H2 molecules. It is found that, when the gas density is sufficiently high, self-shielding of the molecules can move the C(+)/CO and H/H2 transitions close to the surfaces of the molecular cloud where they can feel the full effect of heating by the ultraviolet radiation field. Collisional de-excitation of the H2 can move the lower levels towards low temperature emission producing an apparently shocked line ratio for two low-J levels, while the high-J levels retain a fluorescent value. Appreciable emission in high-J CO molecules originates in this warm molecular gas. Comparison with observation suggests that high density clumps are a common phenomena in photodissociation regions.

Burton, M.↗

IR line emission from supernovae in molecular clouds

The absorption of the x rays from a supernova explosion in the surrounding molecular gas is discussed. A supernova explosion in a molecular cloud results in a supernova remnant which radiates a fraction of the approximately 10 to the 51st power erg kinetic energy of the supernova explosion in the form of x rays. The absorption of these x rays in the surrounding molecular gas produces ionization, dissociation, and heating. It is found that a 10(exp 51) erg supernova explosion in a uniform molecular cloud of density equal to 1000 per cubic centimeter results in the emission of photons in the H2 line. This process may contribute appreciably to the strong S(1) line emission seen from some starburst galaxies, such as NGC 6240.

Draine, B. T.↗

Requirements of IR space astronomy

An introduction to a series of infrared detector technology workshops is given. The establishment of goals and new requirements is addressed in a general way. The Shuttle Infrared telescope Facility (SIRIF) goals are listed. Given that the wavelength coverage is established at 2 to 750 microns and the unvignetted field of view is 7 arcmin, the field should be fully utilized at each wavelength, diffraction should be critically sampled, and each detector should be background limited.

Low, Frank J.↗