Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Quasi-static displacement calibration system for a “Violin-Mode” shadow-sensor intended for Gravitational Wave detector suspensions

This paper describes the design of, and results from, a calibration system for optical linear displacement (shadow) sensors. The shadow sensors were designed to detect “Violin-Mode” (VM) resonances in the 0.4 mm diameter silica fibre suspensions of the test masses/mirrors of Advanced Laser Interferometer Gravitational Wave Observatory gravitational wave interferometers. Each sensor illuminated the fibre under test, so as to cast its narrow shadow onto a “synthesized split photodiode” detector, the shadow falling over adjacent edges of the paired photodiodes. The apparatus described here translated a vertically orientated silica test fibre horizontally through a collimated Near InfraRed illuminating beam, whilst simultaneously capturing the separate DC “shadow notch” outputs from each of the paired split photodiode detectors. As the ratio of AC to DC photocurrent sensitivities to displacement was known, a calibration of the DC response to quasi-static shadow displacement allowed the required AC sensitivity to vibrational displacement to be found. Special techniques are described for generating the required constant scan rate for the test fibre using a DC motor-driven stage, for removing “jitter” at such low translation rates from a linear magnetic encoder, and so for capturing the two shadow-notch signals at each micrometre of the test fibre's travel. Calibration, across the four detectors of this work, gave a vibrational responsivity in voltage terms of (9.45 ± 1.20) MV (rms)/m, yielding a VM displacement sensitivity of (69 ± 13) pm (rms)/√Hz, at 500 Hz, over the required measuring span of ±0.1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature and non-linear response of cantilever-type mechanical oscillators used in atomic force microscopes with interferometric detection

The sensitivity of atomic force microscopes is fundamentally limited by the cantilever temperature, which can be, in principle, determined by measuring its thermal spectrum and applying the equipartition theorem. However, the mechanical response can be affected by the light field inside the cavity of a Fabry-Perot interferometer due to light absorption, radiation pressure, photothermal forces, and laser noise. By evaluating the optomechanical Hamiltonian, we are able to explain the peculiar distance dependence of the mechanical quality factor as well as the appearance of thermal spectra with symmetrical Lorentzian as well as asymmetrical Fano line shapes. Our results can be applied to any type of mechanical oscillator in an interferometer-based detection system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Space-time resolved measurements of spontaneous magnetic fields in laser-produced plasma

The first space-time resolved spontaneous magnetic field (SMF) measurements realized on Prague Asterix Laser System are presented. The SMF was generated as a result of single laser beam (1.315 μm) interaction with massive planar targets made of materials with various atomic numbers (plastic and Cu). Measured SMF confirmed azimuthal geometry and their maximum amplitude reached the value of 10 MG at the laser energy of 250 J for both target materials. It was demonstrated that spatial distributions of these fields are associated with the character of the ablative plasma expansion which clearly depends on the target material. To measure the SMF, the Faraday effect was employed causing rotation of the vector of polarization of the linearly polarized diagnostic beam. The rotation angle was determined together with the phase shift using a novel design of a two-channel polaro-interferometer. To obtain sufficiently high temporal resolution, the polaro-interferometer was irradiated by Ti:Sa laser pulse with the wavelength of 808 nm and the pulse duration of 40 fs. The results of measurements were compared with theoretical analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear reflection of a spherically divergent N-wave from a plane surface: Optical interferometry measurements in air

Mach stem is a well-known structure typically observed in the process of strong (acoustic Mach numbers greater than 0.4) step-shock waves reflection from a rigid boundary. However, this phenomenon has been much less studied for weak shocks in nonlinear acoustic fields where Mach numbers are in the range from 0.001 to 0.01 and pressure waveforms have more complicated waveforms than step shocks. The goal of this work was to demonstrate experimentally how nonlinear reflection occurs in air for very weak spherically divergent acoustic spark-generated pulses resembling an N-wave. Measurements of reflection patterns were performed using a Mach-Zehnder interferometer. A thin laser beam with sub-millimeter cross-section was used to obtain the time resolution of 0.4 µs, which is 6 times higher than the time resolution of the condenser microphones. Pressure waveforms were reconstructed using the inverse Abel transform applied to the phase of the signal measured by the interferometer. The Mach stem formation was observed experimentally as a result of collision of the incident and reflected shock pulses. It was shown that irregular reflection of the pulse occurred in a dynamic way and the length of the Mach stem increased linearly while the pulse propagated along the surface. Since the front shock of the spark-generated pulse was steeper than the rear shock, irregular type of reflection was observed only for the front shock of the pulse while the rear shock reflection occurred in a regular regime.

42 ENGINEERING↗

Binary pseudo-random patterned structures for modulation transfer function calibration and resolution characterization of a full-field transmission soft x-ray microscope

We present a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) one-dimensional sequences and two-dimensional arrays as an effective method for spectral characterization in the spatial frequency domain of a broad variety of metrology instrumentation, including interferometric microscopes, scatterometers, phase shifting Fizeau interferometers, scanning and transmission electron microscopes, and at this time, x-ray microscopes. The inherent power spectral density of BPR gratings and arrays, which has a deterministic white-noise-like character, allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field of view of an instrument. We demonstrate the MTF calibration and resolution characterization over the full field of a transmission soft x-ray microscope using a BPR multilayer (ML) test sample with 2.8 nm fundamental layer thickness. We show that beyond providing a direct measurement of the microscope’s MTF, tests with the BPRML sample can be used to fine tune the instrument’s focal distance. Our results confirm the universality of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The advanced LIGO input optics

The advanced LIGO gravitational wave detectors are nearing their design sensitivity and should begin taking meaningful astrophysical data in the fall of 2015. These resonant optical interferometers will have unprecedented sensitivity to the strains caused by passing gravitational waves. The input optics play a significant part in allowing these devices to reach such sensitivities. Residing between the pre-stabilized laser and the main interferometer, the input optics subsystem is tasked with preparing the laser beam for interferometry at the sub-attometer level while operating at continuous wave input power levels ranging from 100 mW to 150 W. These extreme operating conditions required every major component to be custom designed. These designs draw heavily on the experience and understanding gained during the operation of Initial LIGO and Enhanced LIGO. In this article, we report on how the components of the input optics were designed to meet their stringent requirements and present measurements showing how well they have lived up to their design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying and discriminating phase transitions along decaying shocks with line imaging Doppler interferometric velocimetry and streaked optical pyrometry [Identify phase transition along decaying shocks with line imaging VISAR and streaked optical pyrometry]

Ultrafast line-imaging velocity interferometer system for any reflector and streaked optical pyrometry are now commonly used to obtain high precision equation of state and electronic transport data under dynamic compression at major high energy density science facilities. In this work, we describe a simple way to improve distinguishing phase transformation signatures from other signals when monitoring decaying shock waves. The line-imaging capability of these optical diagnostics offers additional supporting evidence to the assignment of particular anomalies—such as plateaus or reversals—to the occurrence of a phase transition along the Hugoniot. Finally, we illustrate the discussion with two example datasets collected during laser driven shock compression of quartz and stishovite.

47 OTHER INSTRUMENTATION↗

Traceable atomic force microscopy of high-quality solvent-free crystals of [6,6]-phenyl-C{sub 61}-butyric acid methyl ester

We report high-resolution, traceable atomic force microscopy measurements of high-quality, solvent-free single crystals of [6,6]-phenyl-C61-butyric acid methyl ester (PCBM). These were grown by drop-casting PCBM solutions onto the spectrosil substrates and by removing the residual solvent in a vacuum. A home-built atomic force microscope featuring a plane mirror differential optical interferometer, fiber-fed from a frequency-stabilized laser (emitting at 632.8 nm), was used to measure the crystals' height. The optical interferometer together with the stabilized laser provides traceability (via the laser wavelength) of the vertical measurements made with the atomic force microscope. We find that the crystals can conform to the surface topography, thanks to their height being significantly smaller compared to their lateral dimensions (namely, heights between about 50 nm and 140 nm, for the crystals analysed, vs. several tens of microns lateral dimensions). The vast majority of the crystals are flat, but an isolated, non-flat crystal provides insights into the growth mechanism and allows identification of “molecular terraces” whose height corresponds to one of the lattice constants of the single PCBM crystal (1.4 nm) as measured with X-ray diffraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental study on magnetically insulated transmission line electrode surface evolution process under MA/cm current density

The design of high-current density magnetically insulated transmission line (MITL) is a difficult problem of current large-scale Z-pinch device. In particular, a thorough understanding of the MITL electrode surface evolution process under high current density is lacking. On the “QiangGuang-I” accelerator, the load area possesses a low inductance short-circuit structure with a diameter of 2.85 mm at the cathode, and three reflux columns with a diameter of 3 mm and uniformly distributed circumference at the anode. The length of the high density MITL area is 20 mm. A laser interferometer is used to assess and analyze the state of the MITL cathode and anode gap, and their evolution process under high current density. Experimental results indicate that evident current loss is not observed in the current density area at pulse leading edge, and peak when the surface current density reaches MA/cm. Analysis on electrode surface working conditions indicates that when the current leading edge is at 71.5% of the peak, the total evaporation of MITL cathode structure can be realized by energy deposition caused by ohmic heating. The electrode state changes, and diffusion conditions are reflected in the laser interferometer image. The MITL cathode area mainly exists in metal vapor form. The metal vapor density in the cathode central region is higher than the upper limit of laser penetration density (∼4 × 10{sup 21}/cm{sup 3}), with an expansion velocity of ∼0.96 km/s. The metal vapor density in the electrode outer area may lead to evident distortion of fringes, and its expansion velocity is faster than that in the center area (1.53 km/s).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and construction of a point-contact spectroscopy rig with lateral scanning capability

The design and realization of a cryogenic rig for point-contact spectroscopy measurements in the needle-anvil configuration is presented. Thanks to the use of two piezoelectric nano-positioners, the tip can move along the vertical (z) and horizontal (x) direction and thus the rig is suitable to probe different regions of a sample in situ. Moreover, it can also form double point-contacts on different facets of a single crystal for achieving, e.g., an interferometer configuration for phase-sensitive measurements. For the later purpose, the sample holder can also host a Helmholtz coil for applying a small transverse magnetic field to the junction. A semi-rigid coaxial cable can be easily added for studying the behavior of Josephson junctions under microwave irradiation. The rig can be detached from the probe and thus used with different cryostats. The performance of this new probe has been tested in a Quantum Design PPMS system by conducting point-contact Andreev reflection measurements on Nb thin films over large areas as a function of temperature and magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Far-infrared tangential interferometer/polarimeter design and installation for NSTX-U

The Far-infrared Tangential Interferometer/Polarimeter (FIReTIP) system has been refurbished and is being reinstalled on the National Spherical Torus Experiment—Upgrade (NSTX-U) to supply real-time line-integrated core electron density measurements for use in the NSTX-U plasma control system (PCS) to facilitate real-time density feedback control of the NSTX-U plasma. Inclusion of a visible light heterodyne interferometer in the FIReTIP system allows for real-time vibration compensation due to movement of an internally mounted retroreflector and the FIReTIP front-end optics. Real-time signal correction is achieved through use of a National Instruments CompactRIO field-programmable gate array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a Wollaston interferometry diagnostic on OMEGA EP

Here, a Wollaston interferometer is presented for use in measuring the electron density of plasma plumes created in experiments on the OMEGA EP laser system. The diagnostic is installed as an additional arm on the 4ω probe system, a suite of diagnostics that share a 10 ps pulse of 263 nm laser light captured by an imaging system at f /4. The interferometer utilizes a Wollaston prism to create two angularly separated beams from a single input probe beam, split at any angle between 0° and 90°. This configuration is implemented uniquely such that fringe spacing may be altered independently of field of view, magnification, and imaging resolution, from a range of 17 to 76 μm/fringe. The region of overlap between the two beams forms a total field of view of approximately 1.2 × 1.6 mm at the target chamber center with an imaging resolution of 5 μm. Using this configuration, here it is shown that plasma density may be accurately characterized over a range of 3 × 10 18 –1 × 10 20 cm -3 .

47 OTHER INSTRUMENTATION↗

Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators

The method of optical coherence tomography with the scheme of parallel reception of the interference signal (P-OCT) is developed on the basis of spatial paralleling of the reference wave by means of a phase diffraction grating producing the appropriate time delay in the Mach–Zehnder interferometer. The absence of mechanical variation of the optical path difference in the interferometer essentially reduces the time required for 2D imaging of the object internal structure, as compared to the classical OCT that uses the time-domain method of the image construction, the sensitivity and the dynamic range being comparable in both approaches. For the resulting field of the interfering object and reference waves an analytical expression is derived that allows the calculation of the autocorrelation function in the plane of photodetectors. For the first time a method of linear phase modulation by 2π is proposed for P-OCT systems, which allows the use of compact high-frequency (a few hundred kHz) piezoelectric cell-based modulators. For the demonstration of the P-OCT method an experimental setup was created, using which the images of the inner structure of biological objects at the depth up to 1 mm with the axial spatial resolution of 12 μm were obtained. (optical coherence tomography)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical properties of intensity of partially polarised semiconductor laser light backscattered by a single-mode optical fibre

We report the results of studying statistical properties of the intensity of partially polarised coherent light backscattered by a single mode optical fibre. An expression is derived for the deviation of the backscattered light intensity depending on the scattering region length, the degree of the light source coherence and the degree of scattered light polarisation. It is shown that the backscattered light in a fibre scattered-light interferometer is partially polarised with the polarisation degree P = 1/3 in the case of external perturbations of the interferometer fibre. (scattering of light)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency control of tunable lasers using a frequency-calibrated λ-meter in an experiment on preparation of Rydberg atoms in a magneto-optical trap

A new technique is proposed and applied to study the frequency drift of an external-cavity semiconductor laser, locked to the transmission resonances of a thermally stabilised Fabry–Perot interferometer. The interferometer frequency drift is measured to be less than 2 MHz h{sup -1}. The laser frequency is measured using an Angstrom wavemeter, calibrated using an additional stabilised laser. It is shown that this system of laser frequency control can be used to identify Rydberg transitions in ultracold {sup 7}Li atoms. (control of laser radiation parameters)

74 ATOMIC AND MOLECULAR PHYSICS↗

Phasing of independent laser channels under impact SBS excitation

It is shown experimentally that phasing of independent laser channels under impact SBS excitation calls for a stable difference in arm lengths, as in a classical Michelson interferometer. A scheme with automatic compensation for fluctuations of interferometer arm lengths has been proposed and experimentally implemented. This scheme makes it possible to perform stable phasing of two laser channels under standard laboratory conditions. (control of radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical modelling of a fibre reflection filter based on a metal–dielectric diffraction structure with an increased optical damage threshold

Numerical modelling demonstrates the possibility of fabricating an all-fibre multibeam two-mirror reflection interferometer based on a metal–dielectric diffraction structure in its front mirror. The calculations were performed using eigenmodes of a double-clad single-mode fibre. The calculation results indicate that, using a metallic layer in the structure of the front mirror of such an interferometer and a diffraction effect, one can reduce the Ohmic loss by a factor of several tens in comparison with a continuous thin metallic film. (laser crystals and braggg ratings)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗